Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date13 Jan 2025
Closing Date17 Feb 2025
Tender Amount₹ 37,49,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Tender Documents including pre price Sch and credit Sch
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lump sum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-III(Ref pre-priced schedule attached separately)

1

587587

-

... More
Lump sum price worked out by the tenderer for ROAD, PATH, CULVERT AND HARD STANDING as listed in Schedule ‘A’ Part-IV(Ref pre-priced schedule attached separately)

1

50304475

-

... More
Lump sum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-V(Ref pre-priced schedule attached separately)

1

4816868

-

... More
Lump sum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-VI(Ref pre-priced schedule attached separately)

1

1187589

-

... More
Lump sum price worked out by the tenderer for SECURITY WALL, FENCING AND GATE as listed in Schedule ‘A’ Part-VII(Ref pre-priced schedule attached separately)

1

10797044

-

... More
Lump sum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VIII(Ref pre-priced schedule attached separately)

1

207689

-

... More
Lump sum price worked out by the tenderer for EXTERNAL ELECTRIFICATION AND LIGHTENING PROTECTION as listed in Schedule ‘A’ Part-IX(Ref pre-priced schedule attached separately)

1

6705497

-

... More
Lump sum price worked out by the tenderer for HOT WATER SUPPLY, SUMMER APPLIANCES AND AIR CONDITIONING as listed in Schedule ‘A’ Part-X(Ref pre-priced schedule attached separately)

1

4315837

-

... More
Lump sum price worked out by the tenderer for DEMOLITION AND DISMANTLING OF E/M WORKS as listed in Schedule ‘A’ Part-XI(Ref pre-priced schedule attached separately)

1

216627

-

... More
Lump sum price worked out by the tenderer for EXCAVATION AND EARTH WORKS as listed in Schedule ‘A’ Part-XII(Ref pre-priced schedule attached separately)

1

21110345

-

... More
Schedule 'A' Part-XIII(DEMOLITION AND DISMANTLING OF BUILDING WORKS)

-

-

-

... More
Demolition of Buildings as mentioned in Schedule "A" Notes including excavations, earthworks, plumbing works, electrical works etc. and removing all materials including materials under Schedule of Credit, debris, rubbish etc. outside Ministry of Defence Land complete all as specified and as directed.

1

-

-

... More
Schedule 'A' Part-XIV(MISCELLANEOUS PARTS)

-

-

-

... More
Supply and fix rubber speed bump of size 50 mm (height) X 380 mm (width) X 500 mm (length), ABS block black and yellow & reflectors on both sides including necessary fixing arrangements with epoxy/thermoplastic adhesive all as per manufacturers instructions and complying to guidelines issued by Min of Road Transport. etc. complete.

50

-

-

... More
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 150, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.

1456

-

-

... More
S & F class SN 8 structured wall polyethylene piping system (pipe with online coupler and elastomeric rubber ring) with hollow annular profiled outer surface and a smooth inner surface (double wall corrugated) for non-pressure underground drainage and Sewerage application, Type B, Nominal Size (DN/ID) 200, made of polyethylene (PE) material conforming to per IS 16098 (Part 2):2013 and to be transported, handled, installed and jointed as per Annex A of IS 16098 (Part 2):2013 complete all as specified and as directed.

435

-

-

... More
Cutting into existing manholes for connecting new drains of pipe of nominal size 200 mm to 300 mm, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate, smooth finished, and reforming benching as required complete all as specified and as directed.

3

-

-

... More
Supply and fix punched tape concertina coil made out of cold drawn unalloyed steel wires of dia 2.6 mm having minimum tensile strength of 1670 N per sqmm as per IS 4454 (Part- 1): 2001 with hot dip galvanized as per practice recommended in IS: 2629 and the coatings shall conform to heavily coated hard variety as per table I of IS: 4826 (weight of Zinc coating 230 gram per sqm minimum) and steel strip of size 19 mm X 0.5 mm with hardness of 137 to 187 VPN and zinc coating of 18 to 20 microns, minimum 610 mm dia of coil when closed, (9 kg ± 5 %) weight of coil with 50 turns & 129 Nos clips (without handles and spikes) and minimum 580 mm dia when opened upto 6 metres, stretched to 6 metres for 50 turns during installations complete all as specified and as directed.

440

-

-

... More
Supply and fix metal oxide surge arrester without gap for AC system as per IEC 60099-4: 2014, outdoor type, porcelain housing, single column and single phase construction, station class, heavy duty, nominal discharge current 20 kA, switching impulse discharge current 2 kA, repetitive charge transfer rating (Qrs) more than 2.4 C, thermal energy rating (Wth) more than 10 kJ/kV, nominal system voltage 11 kV, highest system voltage 12 kV, rated voltage of arrester 9 kV, continuous operating voltage 7.2 kV, temporary overvoltage (10.15 kV for 1 s, 9.50 kV for 10 s, 8.75 kV for 100 s), rated short circuit current 20 kA, low short circuit current 600 A, insulation withstand level (lightning impulse voltage 1.2/ 50 µs) 75 kV, lightning impulse residual voltage (8/20 µs) at nominal discharge current maximum 26 kV, switching impulse residual voltage (30/60 µs) at switching impulse discharge current maximum 21 kV, high current impulse withstand capability (4/10 µs) 100 kA, minimum creepage distance 300 mm complete all as specified and as directed.

2

-

-

... More
Cutting 250 mm nominal dia ductile iron in position for insertion of new tee piece of ductile iron including complete all as specified and as directed.

1

-

-

... More
Supplying, laying, connecting, jointing and testing in trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.

1110

-

-

... More
Supplying, laying, connecting, jointing and testing in trenches ductile iron fittings (special castings) (class K12 as per IS 9523: 2000) for ductile iron pressure pipe for water mains upto 250 mm nominal dia (spigot and socket and flange ends (for push on joints and flanged joints) with external coatings of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 9523: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 for push on joints and rubber gasket as per IS 638: 1979 for flanged joints complete all as specified and as directed.

250

-

-

... More
M & L for construction of new valve pit/chamber of size 1050 mm (Length) X 1050 mm (Breadth) X 1050 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. BTD-811 Sheet Nos 1/2 and 2/2 of HQ CE Bathinda Zone complete all as specified and as directed.

1

-

-

... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 4.0 mm dia galvanised mild steel wire by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 20 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.

50

-

-

... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 32 mm X 6 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.

18

-

-

... More
S & F LED street light fitting of 45 W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street/Roadway luminaire, with driver complete fitting with all accessories and following specifications, complete all as specified and as directed. (a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range: 140 to 270 volts © Temp operating range: Minus 10°C to Plus 45°C (d) Power factor: Minimum 0.95 € THD: Max10%. (f) IP rating: Minimum IP66. (g) IK rating: Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz. open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT: 5000 K. (m) CRI: More than 80 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time: 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

100

-

-

... More
M & L for bracket made out of GI pipe 40 mm dia medium grade, 1.5 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts complete all as specified and as directed.

100

-

-

... More
S & F three core flexible conductor FR-LSH cables for outdoor use, PVC insulation of type C and having PVC sheath of type ST2, 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor for fittings complete all as specified and as directed.

900

-

-

... More
Supply and laying double wall corrugated pipe (DWC), non-metallic, Resistance to Compression : Type 450, Resistance to Impact: Normal, Resistance to Bending : Pliable, Resistance to External Influence: Ingress Protection : IP 67, Resistance against Corrosion : Without Protection, Resistance to Flame Propagation : Non Flame Propagating, Nominal outside diameter 25 mm, minimum inside dia 18 mm conforming to IS 16205 (Part 24) : 2017 complete all as specified and as directed.

900

-

-

... More
S & F cable junction box of minimum Size 260 mm X 210 mm X 116 mm or any other higher size complete with fixing accessories. Junction box should be insulated and made out of polycarbonate with glass fiber reinforced material. The polycarbonate junction box shall be environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anticorrosive. The junction box knock out on four side wall and following specifications and complete all as specified and as directed. (a) The junction box shall be rated for degree of IP 66 (ingress protection) in accordance with IEC 60529. (b) The gasket material shall be polyurethane or silicon and gasket shall be internally embedded and 63 A four pole terminal stud. (c) Junction Box must meet the provision laid down in IEC 60998-1, IEC-60670-22, IEC-60670-22, IEC 60670-2 to 5 and grey colour according to RAL 7035. (d) The manufacturer of junction box shall submit a copy of IEC certificate and glow wire test for 960 degree. (e) Junction box shall be fire retardant and self-extinguishing in accordance with IEC60695-2 to 11, DIN VDE 0304 Part-3, UL94 V-2 flammability standard. (f) The impact strength of polycarbonate enclosures /boards i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK08. (g) Junction box with stud type terminal, 63A flame retardant one number 6 Amp MCB SP 10KA (h) Manufacturer should submit routine test certificate for junction box. (i) Suitable size of mild steel Clamps duly painted and screws/nut bolt shall be used for fixing of Junction box.

100

-

-

... More
Disconnecting all existing connection including earth wire with transformer of capacity 500 kVA installed on plinth or 2 poles or 4 poles structures and taking down and shifting transformer from any substation under the GE to new location with help of Hydra (Recovery)/JCB/ Crane etc. and including installation installed on plinth or 2 poles or 4 poles structures at new location including connecting all connections, earthing, conductors, cables, nuts, bolts, washers etc. complete all as specified and as directed.

1

-

-

... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 1500 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 1500 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) Air Circuit Breaker (ACB) of rated current 1000 A, Rated operational voltage 415 V, Rated insulation voltage 1000 V, 4 Pole, 50 Hz AC supply, Rated ultimate short circuit breaking capacity 50 kA, Rated service short circuit breaking capacity 50 kA, Rated short time withstand capacity 50 kA for 1 second, Rated making capacity 105 kA, Rated impulse withstand voltage of main circuit 8 kV, typical opening time 40 ms, typical closing time 60 ms, thermal magnetic release, manual draw out, overload protection, short circuit protection, earth fault protection – 1 No (D) Outgoing: (a) MCCB rated current (In): 320 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (b) MCCB rated current (In): 200 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (c) MCB, double pole, 10 kA, C-type, rated current 20 A: -2 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 4 Nos (d) Digital Time Switch: 1 No (e) Contactor 40 A: 1 No (f) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)

1

-

-

... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 200 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 200 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 200 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 100 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (D) Outgoing: (a) MCCB rated current (In): 63 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (b) MCB, double pole, 10 kA, C-type, rated current 10 A: -14 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 4 Nos (d) Digital Time Switch: 1 No (e) Contactor 40 A: 1 No (f) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)

1

-

-

... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 350 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 350 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 320 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No ((D) Outgoing: (a) MCCB rated current (In): 63 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -8 Nos (b) MCB, triple pole neutral, 10 kA, 415 V, C-type, rated current 20 A: -8 Nos (c) MCB, double pole, 10 kA, C-type, rated current 10 A: -9 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 4 Nos (d) Digital Time Switch: 1 No (e) Contactor 40 A: 1 No (f) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)

1

-

-

... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 250 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 250 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 320 A, Icu: 25 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No ((D) Outgoing: (a) MCCB rated current (In): 160 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (b) MCCB rated current (In): 100 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (c) MCCB rated current (In): 63 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (d) MCCB rated current (In): 32 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (e) MCB, double pole, 10 kA, C-type, rated current 10 A: -5 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 4 Nos (d) Digital Time Switch: 1 No (e) Contactor 40 A: 1 No (f) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)

1

-

-

... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 60947 : PART 1 : 2007, locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 350 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 350 Amps rated aluminium bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Incoming: (a) MCCB rated current (In): 200 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No ((D) Outgoing: (a) MCCB rated current (In): 63 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (b) MCCB rated current (In): 40 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -1 No (c) MCCB rated current (In): 32 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -3 Nos (d) MCCB rated current (In): 20 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic (5-10 times) setting, four pole, for 415 V, 50 Hz AC supply: -2 Nos (e) MCB, double pole, 10 kA, C-type, rated current 10 A: -12 Nos (E) Accessories: (a) Digital voltmeter 0-500 V with selector switch – 1 No (b) Digital ammeter 0-200 Amps with CT and selector switch – 1 No (c) LED indicating lamps – 4 Nos (d) Digital Time Switch: 1 No (e) Contactor 40 A: 1 No (f) Danger Notice Plate for LT (F) The rate quoted by tenderer also includes to fix the legs of the panel box in cement concrete M15(Nominal mix) using 20 mm nominal size graded crushed stone aggregate 30 cm below GL and the box will be kept nearly 45 cm above GL including earthwork and allied services complete. The legs of the box will be of 50 mm X 50 mm X 6 mm of length 750 mm.)

1

-

-

... More
Supply, installing, commissioning and testing frost free refrigerator electric driven single phase 220 volts, AC 50 Hz, 195 litres or next higher capacity with BEE approved, minimum 5 star rating single door, stabilizer free operation, Inverter Technology, R600a Refrigerant, tempered glass self, deodorizer and with fruit & vegetables drawer complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.

4

-

-

... More
Supply, installing, commissioning and testing of glass top deep freezer single phase 220 V, 50 Hz, 320 litres or next available higher capacity having single door, direct cool evaporator type, refrigerant R600a, caster lock, Temp range - 18⁰C, Analogue temp setting, magnetic door gasket, caster wheel, inside aluminium cladding, including all inbuilt accessories complete all as specified and as directed. Note (a) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer.

5

-

-

... More
Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, automatic voltage stabilizer of capacity 5 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed.

16

-

-

... More
Supplying, installing, testing and commissioning automatic, servo controlled, indoor type, automatic voltage stabilizer of capacity 1 kVA, single phase, IP55 protection, copper wound, naturally air cooled type, insulation class H, designed for input voltage of 160 V to 270 V and output voltage of 230 V ± 1%, voltage correction rate of 15 V per second, metallic body with lifting hook duly power coated, LCD display for Input and Output Voltage, frequency, current, Time Delay and Mains ON with under and over voltage protection, short circuit protection, surge protection all as per IS 8448: 1989 complete all as specified and as directed.

25

-

-

... More
Supply and Installation of Desert cooler of size 26 inch X 26 inch X 33 inch or next available higher size, electric driven single phase 230 volts GI sheet body having nominal air flow capacity of 4000 Cu M per hours, factory made GI sheet body 18 SWG and side panels of 22 SWG, water sump capacity not less than 120 litres, including water pump submersible type of suitable capacity ISI marked, complete including electric connection complete all as specified and as directed. Note (a) : Sufficient length of 3 core PVC sheathed round copper cable size 23/.0076 to enable fixing in to plug point shall be provided by contractor. (b) GI Pipes, float valve, stop valve, PVC connection shall be measured and paid separately under respective item. (c) Contractor shall submit original purchase voucher and warranty card as recommended by manufacturer. (d) Serial Number as issued by Engineer-in-Charge of cooler and GE Office name shall also be written on cooler with red colour permanent marker or paint, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account

155

-

-

... More
Supplying, installing, testing and commissioning air cooled split unit air conditioner with indoor unit (IDU), outdoor unit (ODU) of capacity 1.50 TR, single phase, input voltage 170 to 270 V AC, 50 Hz, surface / concealed coper Refrigerant piping with insulation (EP Foam pipe section) up to 5 metre (IDU to ODU), copper power cable up to 4 metre, PVC Insulation, FR-LSH copper wire, complete with inverter, twin rotary compressor, cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with BEE 5 star rating complete all as specified and as directed.

8

-

-

... More
Supplying, installing, testing and commissioning air cooled split unit air conditioner with indoor unit (IDU), outdoor unit (ODU) of capacity 2.0 TR, single phase, input voltage 170 to 270 V AC, 50 Hz, surface / concealed coper Refrigerant piping with insulation (EP Foam pipe section) up to 5 metre (IDU to ODU), copper power cable up to 4 metre, PVC Insulation, FR-LSH copper wire, complete with inverter, twin rotary compressor, cordless remote control unit and with inbuilt air ioniser and Plasma filter for better indoor air quality with BEE 5 star rating complete all as specified and as directed.

8

-

-

... More
Taking up 80 mm nominal size/ bore cast iron or galvanised iron or ductile iron water mains (including all fittings), with rubber gasket joints (push on joints) for spigot/socket end or flanged joints with flanged end joints including disconnecting pipes and fittings including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

150

-

-

... More
Taking up 150 mm nominal size/ bore cast iron or galvanised iron or ductile iron water mains (including all fittings), with rubber gasket joints (push on joints) for spigot/socket end or flanged joints with flanged end joints including disconnecting pipes and fittings including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

350

-

-

... More
Taking down existing sluice valve or nonreturn valve of nominal size of 150 mm and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.

3

-

-

... More
Taking down existing sluice valve or nonreturn valve of nominal size of 80 mm and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.

2

-

-

... More
Taking down existing gate valve any type and any size and removing to MES store yard or taken on schedule of credit complete all as specified and as directed.

15

-

-

... More
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 4 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 4 sqmm cable, one run of 4 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)

2700

-

-

... More
M & L for felling of tree having girth exceeding 300 cm but not exceeding 350 cm including cutting of trunk, and branches and stacking of serviceable material and disposal of unserviceable material to a distance not exceeding 50 m and clearing the site complete all as specified and as directed.

3

-

-

... More
M & L for grubbing up tree trunk for tree having girth exceeding 300 cm but not exceeding 350 cm including cutting of trunk portion protruding over ground, digging out roots, filling holes and levelling off ground, stacking of serviceable material and removing of unserviceable material to a distance not exceeding 50 m and clearing site complete all as specified and as directed.

3

-

-

... More
M & L for concealed point wiring for one light or one fan or one exhaust fan controlled by one switch complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

1597

-

-

... More
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

193

-

-

... More
M & L for concealed point wiring for one 3 pin/ 5 pin 5 Amps socket outlet on the same board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

66

-

-

... More
M & L for concealed point wiring for one bell/ buzzer point controlled by one push button on the same board with other switches or on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 1.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 1.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

10

-

-

... More
M & L for point wiring for one 3 pin/ 5 pin/ 6 pin 5/15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 2.5 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 2.5 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

100

-

-

... More
M & L for concealed point wiring for one 3 pin/ 5 pin 15 Amps socket outlet on independent board complete with and including single core PVC insulated, unsheathed flexible conductor FR-LSH cables 4 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through & including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including modular/ non modular type, all accessories/ fittings/ junction boxes/ inspection cover etc. ISI marked and sunk terminal boxes flush galvanised metal boxes suitable for fixing with 4 sqmm copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable as continuous earth wire connected to metallic body at one end and common earth dolly to other end including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note: Cost of cutting chase and making good shall be included in the quoted rate.)

114

-

-

... More
S & F double door MCB Distribution board of sheet metal enclosure, single pole and neutral, 6 way with 200 Amps rated bus bar, 240 volt, IP42 protection grade and fixed with PVC plug and screws and grouted in wall with M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate complete all as specified and as directed.

4

-

-

... More
S & F TPN distribution board 4 way vertical type double door made out of CRCA mild steel sheet surface with insulated material like polyester or with powder coating flush/surface mounting with copper busbar of suitable rating, with neutral bar and earth bar and cable tie for cable management, IP54 Protection and provision and including MCCB 4 pole 160 Amp,16KA as incomer and provision for MCBs as outgoing, dust and vermin proof complete as per IEC61439-3 complete all as specified and as directed. Note: MCBs for outgoing shall be measured and paid separately.

14

-

-

... More
S & F modular blanking plate 1 module complete all as specified and as directed.

30

-

-

... More
Supply and fix concealed sub main wiring complete with and including two Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm one No single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Two runs of 6 sqmm cable, one run of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)

800

-

-

... More
Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 6 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 6 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 6 sqmm cable, two runs of 6 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)

300

-

-

... More
Supply and fix concealed sub main wiring complete with and including four Nos single core PVC insulated, unsheathed flexible conductor FR-LSH cables 10 sqmm as per IS 694: 2010, ISI marked, annealed, multistranded copper conductor drawn through and including medium mechanical stresses class PVC conduit as per IS 9537 (Part-III): 1983 of suitable nominal size as required at site dia but not less than 20 mm nominal size including all accessories and fixed on walls and 10 sqmm two Nos single core copper conductor PVC insulated, unsheathed flexible multistranded copper conductor FR-LSH cable for earthing and connected to common earth dolly including cost of cutting chase and making good to disturbed surfaces of wall with cement mortar 1:3 including necessary plaster and pointing in cement mortar 1:3 with white wash/distemper/other paintings complete all as specified and as directed. (Note 1- Four runs of 10 sqmm cable, two runs of 10 sqmm cable and one run of conduit shall be measured and paid as one unit length. Note 2- Cost of cutting chase and making good shall be included in the quoted rate.)

200

-

-

... More
S & F LED bulb, System Wattage: 9 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.

177

-

-

... More
S & F LED bulb, System Wattage: 0.5 Watt, Rated Voltage: 230 Volt, Frequency: 50 Hertz, Operating Voltage Range: 170 to 270 Volt, System Current (mA): 46, Power Factor: ≥ 0.98, System Lumen Efficacy (lumens/watt or lumens): 100, Total Harmonic Distortion (THD): ≤ 30 %, Color Rendering Index (CRI): ≥ 80, Driver Efficiency: ≥ 85 %, Ingress Protection: IP20, Correlated Color Temperature (CCT) (As per ANSI): 6500⁰ Kelvin, Mounting/Holder Type/Base cap: B22d, System Protections: Open & Short circuit protection, reverse polarity protection, surge protection of 2.5KV internal, Certification Standards: LM80, Conformity to Indian Standard: IS:16102 part I and Part II latest complete all as specified and as directed.

6

-

-

... More
M & L for bracket made out of GI pipe 32 mm dia medium grade, 1.2 metre long bent to shape with MS flat iron clamps made out of 40 mm X 6 mm thick mild steel nuts, bolts including taking down old unserviceable complete all as specified and as directed.

129

-

-

... More
S & F telephone socket outlet complete all as specified and as directed.

25

-

-

... More
S & F 1 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed.

125

-

-

... More
S & F television antenna socket outlet complete all as specified and as directed.

5

-

-

... More
S & F co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit complete all as specified and as directed.

125

-

-

... More
S & F 15 mm nominal size, nonrising spindle type fancy angle stop valves, two ways in double control with wall flange, made of cast brass including knob, knob components, divertor & components, nickel-chromium plated finish complete all as specified and as directed.

52

-

-

... More
S & F single lever concealed divertor including bath spout and shower complete all as specified and as directed.

2

-

-

... More
S & F central hole basin mixer without popup waste system with 450 mm long braided hoses as per Product Code: CON-CHR-167KNB of Jaquar or equivalent of kohler/marc complete all as specified and as directed.

50

-

-

... More
Schedule 'A' Part-XV(FURNITURE)

-

-

-

... More
Almirah small steel as per drawing No. FD-1032 sheet No. 1/1

38

-

-

... More
Almirah large steel as per drawing No. FD-1031 sheet No. 1/1

37

-

-

... More
Locker (steel) as per drawing No. FD-1029 sheet Nos 1/2 & 2/2

258

-

-

... More
Work bench workshop (1800 mm X 900 mm X 760 mm) (steel) as per drawing No. FD-1024 sheet No. 1/1

1

-

-

... More
Black board with easel and pointer (steel) as per drawing No. FD-1041 sheet No. 1/1

1

-

-

... More
Kit box (steel) as per drawing No. FD-98(M) sheet No. 1/1

1

-

-

... More
Book case (steel) as per drawing No. FD-1028 sheet No. 1/1

1

-

-

... More
Bath Mat (PVC) as per drawing No. FD/E6/MAP/07 sheet No. 1/1

5

-

-

... More
Bed Hard as per drawing No. FD/E6/MAP/08(R) sheet No. 1/1 

1

-

-

... More
Board notice (900 mm X 600 mm) as per drawing No. FD-1042 sheet No. 1/1

1

-

-

... More
Chair easy per drawing No. FD-229 sheet No. 1/1

87

-

-

... More
Chair CB'A' special with hand rest as per drawing No. FD-120(M) sheet No. 1/1

51

-

-

... More
Chair easy as per drawing No. FD-358 sheet No. 1/1

4

-

-

... More
Chair writing as per drawing No. FD-280 sheet No. 1/1

183

-

-

... More
Chair CB (Office) without arms (steel) as per drawing No. FD-75(M) sheet No. 1/1

35

-

-

... More
Chair CB (Office) with arms (steel) as per drawing No. FD-75(M) sheet No. 1/1

151

-

-

... More
Chair CB steel with arms cushion of Make:- Methodex, Model No:- TCC-2/Godrej/Geeken as approved by the GE

22

-

-

... More
Chair Verandah as per drawing No. FD-359 sheet No. 1/1

10

-

-

... More
Chair wooden bottom without arms as per drawing No. FD-285 sheet No. 1/1

9

-

-

... More
Chair dining as per drawing No. FD-279 sheet No. 1/1

95

-

-

... More
Executive chair revolving of Make:- Methodex, Model No:- MHB /Godrej/Geeken as approved by the GE

1

-

-

... More
Charpoy with hard top as per drawing No. FD/MAP-II/01 sheet No. 1/1

333

-

-

... More
Filing cabinet 4 Drawers as per Make:- Methodex, Model No:- FC4DR/Godrej/Geeken as approved by the GE

2

-

-

... More
Form without back(1525 mm long) (steel) as per FD-1027 sheet No. 1/1

5

-

-

... More
Form with back (1800 mm long) as per drawing No. FD-78(M) sheet No. 1/1

6

-

-

... More
Chair Draughtsman as per drawing No. FD-204 sheet Nos 1/1

2

-

-

... More
Desk with Dias Wooden as per drawing No. FD-399 sheet Nos 1/2 and 2/2

2

-

-

... More
Display Board (1200 mm X 900 mm) as per drawing No. GE/ABH/FD

5

-

-

... More
Drugget of variety No. Wollen, 60 tex X 12 warp, size 3000 mm X 2000 mm as per IS 697: 2005

2

-

-

... More
Hat stand with mirror (large) as per drawing No. FD-362 sheet No. 1/1

1

-

-

... More
Hot case small as per drawing No. FD-363 sheet No. 1/1

6

-

-

... More
Ladder aluminium as per drawing No. FD-1025 sheet No. 1/1

2

-

-

... More
Pointer short 900 mm as per drawing No. FD-71(M) sheet No. 1/1

3

-

-

... More
Pointer medium 1220 mm as per drawing No. FD-71(M) sheet No. 1/1

2

-

-

... More
Pointer long 1525 mm as per drawing No. FD-71(M) sheet No. 1/1

2

-

-

... More
Peg table (450 mm X 300 mm X 380 mm) as per drawing No. FD-277 sheet No. 1/1

6

-

-

... More
Rack pigeon hole (steel) as per drawing No. FD-1037 sheet No. 1/1

1

-

-

... More
Receptacle (large) with bucket as per drawing NO. FD-1044 sheet No. 1/1

17

-

-

... More
Rack for 10 rifles as per drawing No. STD 145.1.2 of E-in-C's Branch Army Headquarter

1

-

-

... More
Side rack with tray four spaces (steel) as per FD-1023 Sheet No. 1/1

52

-

-

... More
Sofa set 5 seaters (3 + 1 + 1) as per drawing No. FD/MAP-II/02 sheet Nos 1/2 & 2/2

2

-

-

... More
Stool steel (760 mm high) as per drawing No. FD-409 sheet No. 1/1

55

-

-

... More
Table clerks (steel) as per drawing No. FD-1004 sheet No. 1/1

91

-

-

... More
Table officers (steel) as per drawing No. FD-1003 sheet Nos 1/2 & 2/2

24

-

-

... More
Table bed Side as per drawing No. FD/E6/MAP/15(R) sheet No. 1/1

1

-

-

... More
Table marble top (1530 mm X 900 mm X 760 mm) as per drawing No. FD-298 sheet No. 1/1

5

-

-

... More
Table pantry (steel) as per drawing No. FD-1020 sheet No. 1/1

1

-

-

... More
Table dining 6 persons as per drawing No. FD/MAP-II/03 sheet No. 1/1

17

-

-

... More
Table with stainless steel top (2100 mm X 900 mm X 760 mm) (steel) as per drawing No. FD-1013 sheet No. 1/1

1

-

-

... More
Table with drawer (900 mm X 600 mm X 760 mm) (steel) as per drawing No. FD-1008 sheet Nos 1/2 & 2/2

37

-

-

... More
Table for Havs & Ors (steel) as drawing No. FD-1007 sheet No. 1/1

17

-

-

... More
Table (600 mm X 600 mm X 760 mm) as per drawing No. FD-293 sheet No. 1/1

15

-

-

... More
Table centre as per drawing No. FD-375 sheet No. 1/1

4

-

-

... More
Teapoy as per drawing No. FD-278 sheet No. 1/1

10

-

-

... More
Table draughtsman as per drawing No. FD-303 sheet No. 1/1

2

-

-

... More
Table card (900 mm X 900 mm X 760 mm) as per drawing No. FD-352 sheet No. 1/1

1

-

-

... More
Chair for table card as per drawing No. FD-353 sheet No. 1/1

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.