Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694611_1Tender No
8286/GE/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
M&L for Dry tibba sand cushioning to underground cable provided with a layer of 8cm deep before laying cable and 15cm after laying of cable and punned to 18cm after laying of cable and cover for protection of underground cable complete all as specified and directed. Notes :- (i) Approved dry tibba sand free from vegetation, grass and other deleterious substances shall be used. (ii) For the purpose of payment only punned thickness shall be measured for payment.
97
-
-
... More
M&L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cableall as specified and directed.
1500
-
-
... More
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil.
(b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter.
(c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed
(d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed.
(e) Requisite quantity of common salt and charcoal.
(f) Testing of earthing.
4
-
-
... More
M&L for earth continuity conductor 25X4 mm GI strip fixed to wall or recess or chasses or burried in ground or drawn in conduit pipe /pipe 40 mm dia light grade all as specified and directed.
20
-
-
... More
Supply, laying or fixing or passing through GI pipe, commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor,1100 volts cross sectional area 16 Sqmm 4 core complete, including suitable size lugs including taking out /dismantling of existing cable. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
500
-
-
... More
-ditto- all as per item No 8.00 above but 25 Sqmm 4 core
500
-
-
... More
-ditto- all as per item No 8.00 above but 35 Sqmm 3.5 core
200
-
-
... More
-ditto- all as per item No 8.00 above but 50 Sqmm 3.5 core
200
-
-
... More
-ditto- all as per item No 8.00 above but 240 Sqmm 3.5 core
140
-
-
... More
M&L for GI Tubes, of following size, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed.
(a) 40 mm bore
18
-
-
... More
-ditto- all as per item No 9.00 above but 50 mm bore
12
-
-
... More
-ditto- all as per item No 9.00 above but 80 mm bore
6
-
-
... More
Supply and fix in replacement of ACB 4 pole 800 Amp, four pole manual draw out type with mircoprocessor release with all protection bypass facility shunt & UVT with breaker ON, OFF, Trip indication, Ampere meter with selector switch all as specified and directed by Engr-in-Charge.
1
-
-
... More
M&L for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine for inserting GI pipe of size 100/80 mm not less than one metre below ground level complete all as specified & directed by Engineer-in-charge.
12
-
-
... More
Routine and periodical cleaning the inside area of Installations/Sub Stations including cutting and removal/uprouting of unwanted grass/bushes, small trees near all around sub station and pump houses complex complete including surface dressing and leveling by surface excavation wherever as required or as directed.
390
-
-
... More
Supply, installation, commissioning and teststing of 200 Amps, 3 phase 4 wire, 415 Volts, 50 Hz, IGBT fired modular type Active Power with touch screen HMI unit with 400 Amps incommer MCCB, 50 KA, electronic release, 415 Volts, 4 pole, enclosure shall be made out of 2mm thick CRCA sheet mounted on base chanel of size MC-75 all around and 04 Nos of equal angle iron legs of 75x75x6mm of length 0.60 mtr, pre wired, with suitable bas bar as per requirement, ready to use panel, siemens Gray 7032 color coated, IP-20 Protection with future provisions complete in and including taking out existing arrangement of any type and size complete all as specified and directed. Make : Universal Switchgear control/Tricolite/Siemens/ABB
Note :(i) Modular IGBT based Active Power filter units with embedded cooling fans should be used in separate non compartmentalized compartments in APF with proper ventilation to reach the target rating of total Active Harmoni filtration, Temperature sensors shall be provided to monitor APF module"s internal temperature and cooling fans, rotating speed shall be adjusted according to the detected internal temperature, each filter module is working independently even if one module got faulty rest system will work independently.
(ii) Modular APF unit/units shall have basic function of harmonic current elimination to reduce THD-I and load imbalance correction.
(iii) The APF system shall be modular as described above with each APF module shall be capable to mitigate harmonic, Power factor correction (lead and Lag) and unbalancing. It should work normally even when anyone of the module gets failure in case of multiple modules. The APF system should be able to eliminate harmonic current of 2nd to 50th order selectable) and correct load imbalance (compensate Negative and zero sequence). Its operational voltage Range should be AC 415V +15%, -20%, L-L, Frequency Range 50/60Hz (+-5Hz), It should have power scalability. One HMI display module should be able to display running data and set parameters for multiple APF modules in Hybrid System
(iv) APF shall have inrush current 120% of its rated current, Instant Response Time : 100us. Full ResponseTime : 20ms. Operating Ambient Temperature : -10 to 50 without derating. Programmable current Transformer Ratio. It shall have built in protection against surges, sags, over voltage and voltage surges from AC source, and load switchging and circuit breaker operation in the distribution system. The APF shall be CE marked in accordance with EEC directives 73/23 " Low voltage" and 93/68 electromagnetic compatibility.
1
-
-
... More
Supply, fixing, connecting, installation, commissioning and testing factory made and type tested AMF panel suitable for 500 KVA DG set with by pass arrangements for main and DG set both outdoor type, plateform mounted, suitable for 415 volts 3 phase and neutral, 4 wire, 50 Hz, AC supply system, Suitable size tinned copper busbar shall be provided for all connection/interconnections, The panel shall be dust and vermin proof, protection class (IP-54) and made out of 3.15mm thick CRCA mild steel sheet and mild steel mounting channel work made out of MC-75, front opening type with proper ferrule & cable gland, internal wiring with PVC insluated multistranded copper conductor FRLS cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyster powder coating siemens grey shade 7035 in and including taking down of old unserviceable AMF panel. The scope of work also comprising of the following :-(a) Under voltage relay 415 Volts AC for main - 01 Nos (b) Under voltage telay 415 volts AC for DG set - 01 Nos (c ) AC timer 230 volts, 2 No, + 2NC-01 Nos (d) DC timer 12/24 volts-01 Nos (d-1) Engine Starting Relay 24 V DC-01 Nos (e) Control MCB SP 6 Amps, 230 Volts-06 Nos (f) Control MCB SP 16 Amps, 230 Volts-02 Nos (g) Battery charger 12/24 volts DC with SMPS-01 Nos (h) LED Indicating light for main & DG set - 06 Nos (h-1) LED indicating light for Main & DG set ON-02 Nos (j) LED indicating light for battery charger-01 No (k) Digital volt meter (0-500 Volts) 96mm x 96mm - 01 Nos (l) Digital Amp meter (0-100 Amps) 96mm x96mm - 01 Nos (m) Volt meter selector switch - 01 Nos (n) Ampere meter selector switch - 01 Nos (o) CT Coil 800/5 A Tape wound - 03 Nos (p) DC voltmeter 15/30V-01 Nos (q) DC Amp meter 0-15 Amps-01 Nos (r ) Trickle/boost switch Cat No 61100 of L&T- 01 Nos and selector switch ON/OFF Cat No 61001 of L&T (s) Auto /manual switch cat No 61026 of L&T - 01 Nos (t) Start/Stop push button - 21 Nos(t-1) Hooter 24 V DC-01 Nos (u) ACB 1000 A 50 KA, 4 pole EDO, thermal release for main supply - 1 Nos (v) ACB 1000 A 50 KA, 4 pole EDO, thermal release for DG supply - 1 Nos
(w) On load change over switch 800 A, 4 pole for bye pass main supply-01 Nos (x) On load change over switch 800 A, 4 pole for bye pass DG supply-01 Nos (y) Control Relay - 02 Nos, (z) Overload Relay 3-5 A - 01, (aa) Tinned copper bus bar for of suitable size, 4 Nos and for all interconnections (ab) Enclosure made out of 3.15mm thick CRCA sheet, double door, outdoor type (ac) All control cable required the AMF panel functional from DG set to AMF panel shall be deemed to be included in unit quoted rates alongwith necessary protection material as per site requirement complete, all above accessories shall be fixed in the panel neatly, The AMF panel will be made outdoor type in and including dismantling of existing arrangements. Note : 1. The AMF Panel will be manufactured by CPRI approved firm mainly - Universal switchgear, Tricolite, Siemens, ABB. The contractor shall submit drawing of the AMF panels to Engr-in-charge before procurement of AMF panel for approval alongwith CPRI approval. Foundation will prepared as per recommendations of the manufacturer after dismantling of existing foundation and the cost of the same is deemed to be included in unit quoted rates. 2. Anything missed out above, the contractor shall provide the same and will made the AMF pannel functional without any extra cost to the department
1
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%