Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 98,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_661870_1Bid Award Id
ViewTender No
GE (N) BKN-TOKEN/16/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Ditto All as per Srl item No 01 here in above but size of cable 25 Sqmm 4 core
800
-
-
... More
Ditto All as per Srl item No 01 here in above but size of cable 35 Sqmm 3.5 core
1000
-
-
... More
Ditto All as per Srl item No 01 here in above but size of cable 50 Sqmm 3.5 core
500
-
-
... More
Ditto All as per Srl item No 01 here in above but size of cable 95 Sqmm 3.5 core
300
-
-
... More
Ditto All as per Srl item No 01 here in above but size of cable 120 Sqmm 3.5 core
300
-
-
... More
Ditto All as per Srl item No 01 here in above but size of cable 150 Sqmm 3.5 core
300
-
-
... More
Ditto All as per Srl item No 01 here in above but size of cable 185 Sqmm 3.5 core
400
-
-
... More
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc., complete all as specified and as directed.
5
-
-
... More
Dismantling Insulators like Pin type, Shackle type from existing Electric Poles of any description and any size, seggregating Seviceable Insulators and keep in safe custody for re-use, complete all as specified and as directed.
170
-
-
... More
Dismantling ACSR or AAC Conductors from the Disturbed Span including Line Spacer, etc., complete all as specified and as directed.
8
-
-
... More
Dismantling Earth Wire, Cradle Guarding, etc., complete all as specified and as directed.
4
-
-
... More
S&F Cable jointing kit for LV/LT 1100 V cable for straight through , heat shrinkable type joint kit complete with jointing material and accessories suitable for 25 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
10
-
-
... More
Ditto All as per Srl item No 15 here in above but 70 Sqmm to 150 sqmm 3.5 Core
8
-
-
... More
Ditto All as per Srl item No 15 here in above but 185 Sqmm to 300 sqmm 3.5 Core
6
-
-
... More
Cable indoor / outdoor end terminals jointing kit for LV/LT 1100 V cable heat shrinkable type joint kit complete with jointing material and accessories, thimbles etc suitable for 25 Sqmm to 50 Sqmm 3.5 core XLPE armoured aluminium conductor cable including testing after jointing, fixing in replacement complete all as specified as directed by Engineer-in-Charge.
90
-
-
... More
Ditto All as per Srl item No 18 here in above but 70 Sqmm to 150 sqmm 3.5 Core
20
-
-
... More
Ditto All as per Srl item No 18 here in above but 185 Sqmm to 300 sqmm 3.5 Core
30
-
-
... More
Taking out old LT underground cable and laying after removing of defects any type/size laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc including commissioning and testing complete all as specified and as directed by Engineer-in-Charge.
500
-
-
... More
Supply and laying un-reinforce precast concrete cable cover, class LV type-1, size 250 mm X150 mmx 40mm for protection of cable complete all as specified and as directed by Engineer-in-Charge.
35200
-
-
... More
Dismantling unserviceable LT Poles of any description and any size including demolition of Cement Concrete (as/if required) and made good disturbed Ground complete all as specified and as directed.
Note : Unsv Poles will be dismantled at Ground Level and disturbed ground will made good as directed for which Earthwork, demolition of Cement Concrete, etc. will not be measured and paid separately.
25
-
-
... More
Supply & Erecting Steel Tubular Swaged Pole Type 410-SP-31 (9.0 Metre long) including Cast Iron Base Plate, Finial Taper Plug, Cap, Mild Steel Bolts, Nuts, Screws including applying two coats of Black Bituminous Paint Internally and Externally from bottom End of Pole upto PCC Coping and applying with two coats of Aluminium Painting over a coat of red oxide Primer (Externally from Top of Coping)and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (4 No. Each Strip 300 mm wide) and also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint complete all as specified and as directed.
Note : Earthwork, Cement Concrete, etc. will be measured and paid under approprite Items.
15
-
-
... More
Pre-stressed concrete poles 9 meter long, 102mm x 172mm at top and 102 mm x 279 mm at bottom, class 10, complying with requirements of IS-1678, including painting with two coats of synthetic enamel paint (in alternate black & white/yellow strips of 30 cm height) upto 1.5 meter height from top of PCC coping and also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint complete all as specified and as directed by the Engineer-in-Charge.
10
-
-
... More
M&L for Plain cement concrete (1:3:6) type C-2 using 20mm graded stone aggregates as in foundation for stay and copping of pole above ground level including finishing to exposed concrete surfaces even and fair and provision of form work for rough finished surfaces complete all as specified and as directed by Engineer-in-Charge.
8
-
-
... More
M&L FOR Plain cement concrete (1:4:8) type D-2 using 40mm graded stone aggregates as in foundation for pole complete all as specified and as directed by Engineer-in-Charge.
9
-
-
... More
Demolition of old PCC foundation block/copping of LT/HT pole complete all as specified and as directed by Engineer-in-Charge.
17
-
-
... More
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil.
831.6
-
-
... More
Excavating in trenches, n exc 1.5 m wide and exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. nexc 10 sq m on plan and exc 1.5 m in depth but not exc 3 m in depth and getting out in soft/loose soil.
2.5
-
-
... More
Returning, filling in soft/loose soil including spreading, leveling, watering and well ramming, in layers not exc 25 cm complete all as specified and as directed by the Engineer-in-Charge.
567.68
-
-
... More
Removing of surplus soil to a distance not exc. 50 meter and depositing where directed at a level not exc.1.5 metre above the starting point complete all as specified and as directed by the Engineer-in-Charge.
263.92
-
-
... More
Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge.
150.54
-
-
... More
Supply and fixing in replacement GI pipe light grade 40 mm bore (ISI marked) laid in trenches/ road crossings/ fixed to poles/ceiling / along walls/ path /drain/floors with and including all necessary clamps, nuts, bolts, washers etc and all fittings as required, complete all as specified and as directed by the Engineer-in-Charge.
(Note :- Necessary excavation, earth work and same work shall be measured and paid for separately.)
50
-
-
... More
Ditto All as per Srl item No 34 here in above but dia of pipe 50 mm
80
-
-
... More
Ditto All as per Srl item No 34 here in above but dia of pipe 80 mm
30
-
-
... More
Boring of holes under road 110 mm dia, pavement, hard standing by trench less technology(manually) with out disturbing the top surface of roads for laying of cables/GI pipes complete all as specified and as directed by the Engineer-in-Charge.
120
-
-
... More
Supply and fixing in replacement MCCB,63 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA Ics=100%Icu, fixed Thermal Megnetic Release including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified. Make: ABB/Scheinder/C&S
10
-
-
... More
Supply and fixing in replacement MCCB, 100 Amps, 4 pole, 415 Volts, rupturing capacity not less than 25 KA Ics=100%Icu, fixed Thermal Megnetic Release including thimbles, nuts, bolts, washers etc. making including incoming and outgoing connection complete all as specified. Make: ABB/Scheinder/C&S
8
-
-
... More
Ditto All as per Srl item No 39 here in above but 160 Amps
5
-
-
... More
Ditto All as per Srl item No 39 here in above but 36 KA 200 Amps
8
-
-
... More
Ditto All as per Srl item No 39 here in above but 36 KA 400 Amps
8
-
-
... More
Supplying and laying heavy duty PVC cable insulated standard Aluminium conductor 1100 volt grade served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended by insulating hangers more than 1 mtr apart including 4mm suspension wire, one twin core cable flat or circular, size 06 sq mm in replacement complete all as specified and as directed by Engineer-in-Charge.
450
-
-
... More
Ditto All as per Srl item No 43 here in above but 10 Sqmm
450
-
-
... More
Ditto All as per Srl item No 43 here in above but 16 Sqmm
450
-
-
... More
Supplying and stringing in replacement Aluminium conductor, steel reinforced (ACSR) any type of ACSR conductor as per site requirement of size /make as ordered including stringing for overhead line on LT poles including aluminum binding wire 14 SWG, jumpers, line tapes, conducting jelly etc complete all as specified and as directed by Engineer-in-Charge.
(Notes : (i) The ACSR conductors shall be conforming to IS-398 and as specified in SSR Part-I.(ii) The unit rate quoted shall also be deemed to include for supply & fixing of aluminium binding wire, aluminium tapes etc which shall not be included in the weight of conductors.(iii) Weight of conductors shall be determined by measuring true horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers etc.
(iv) Weight of the conductors shall be calculated from the nominal weights given in tables in the relevant IS.)
8
-
-
... More
M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Steel Tubular Poles (above the Planting Depth and PCC Copings) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying one Coat of Red Oxide Zinc Chrome Primer, alternate Yellow & Black Strips Painting (5 No. Each Strip 300 mm wide) and remaining portion of Pole also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint and Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint complete all as specified and as directed.
200
-
-
... More
M & L preparing old painted surfaces by scraping and removing old paints, rust, etc. from Pre-stressed Concrete Pole (above the Planting Depth and PCC Copings) and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. and applying Two Coats of Synthetic Enamel Painting in alternate Yellow & Black Strips Painting (5 No. Each Strip 300 mm wide) and remaining portion of Pole treated with Two Coats of Exterior Weather Proof Paint also including numbering to poles with synthetic enamel paint on black base of size 15 cm x 10 cm and numbering in 8 cm height of number with white paint and Mild Steel Cross Arms, Cable Protection Pipe, Brackets, etc. treated with Two Coats of Aluminium Paint complete all as specified and as directed.
400
-
-
... More
Supply and fixing in replacement of Galvanised steel wire, 4mm dia (No 8 SWG) for continuous earth wire and Cradies, hexagonal/rectangular, fabricated with galvanised steel wire 3.15 or 4 mm dia complete all as specified by Engineer-in-Charge.
4
-
-
... More
supply and fixing Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-0 or Fe-310-0 grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces after preparation of surfaces, supplied and fixed in repair complete all as specified and as directed by Engineer-in-Charge.
(Note: - (i) Sizes & types of members and shape of the cross arms etc shall be as required at site all as directed by the Engineer-in-Charge.(ii) Un-exposed steel surfaces shall be given one coat of red-oxide zinc chromate primer only. Cost of the same is included in unit rate of the item and nothing extra shall be paid on this account.)
5
-
-
... More
Supplied and fixed in repair Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100 mm height, 65 mm dia. for working pressure 1100 volts grade, complete all as specified and as directed by Engineer-in-Charge.
120
-
-
... More
S&F in replacement for shackle type, vitreous, white, brown, or green insulators, including galvanised mild steel strips, washers, insulators bolts, washers and nut for working pressure 1100 Volt, 100mm height 115mm dia, glavanised steel fitting strips of size 21 x 5mm, 14mm dia bolts complete all as specified and as directed by Engineer-in-Charge.
50
-
-
... More
Danger notice plate of size 20cm x 15 cm x 1.60 mm thick of mild steel sheet, vitreous, enameled white, with letters, figures and conventional skull & bones in signal red colour and fixed with MS clamps made out of 25 mm x 3mm MS flat iron including bolts and nuts of approved size for LT 1100 volts, complete all as specified and as directed by Engineer-in-Charge.
150
-
-
... More
Supplied and fixed in replacement of GI strip of size 32mm x 6.0 mm complete all as specified and as directed by the Engineer-in-Charge.
200
-
-
... More
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge of the plate at a depth not less than 1.5 m below ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides, connected to galvanized earth wire 4 mm dia with and including nuts, bolts, check nuts & washers of galvanized iron or steel and riveted to earth plate at one end and connecting to main switch board or metallic bodies of HT/LT equipments etc at the other end, GI wire encased in and including 20 mm bore GI light grade pipe with all fittings, from top of electrode to body of equipment fixed with and including 25 x 6mm flat iron clamps, bolts, nuts and washer and also including providing watering pipe 20mm bore GI pipe light grade and including funnel, wire mesh, copper lugs etc from bottom of earth pit to top of electrode complete with earth pit in PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate and CI cover complete all specified and shown in electrical plate No 05 of SSR Pt-I connecting earth electrode to test point with and including earthing lead including necessary excavation and earthwork in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50m, material and labour complete all as specified and as directed by Engineer-in-Charge.
(Notes 1. The rate quoted shall be deemed to include for all the above provisions. 2. PCC chamber shall be constructed at least 1.5 m away from the earth electrode and pipe for watering shall be provided in slanting manner).
10
-
-
... More
Ditto all as per Seiral item No 55 here in before but using galvanised iron strip 32 x 6 mm as earthing lead complete all as specified and as diredted by Engineer-In-Charge.
20
-
-
... More
Surface dressing/ cleaning of surrounding area of LT panel / two pole/four pole structure/ substation/transformer area/sub station and surface including removing of tree branches complete all as specified and as directed by Engineer in charge
5000
-
-
... More
Disconnect the electric supply from Main GO/DO and taking down old existing Loose ACSR conductor mounted on Steel/PCC pole 4 to 6 Conductor and Re-stringing of existing over head line ACSR conductor/GI wire of any size/type including repair of conductor broken due to wind storm/expansion, contraction etc, on existing LT steel and/or PCC pole including replacement of aluminium binding wire of suitable size and refixing of all old accessories carefully without damaging of insulator etc complete all as specified and directed by Engineer-in-Charge.(Note: A Team of workers for emergency are avlaible 24 Hours)
300
-
-
... More
Ditto all as per Seiral item No 58 here in before but using 7 to 9 Conductor complete all as specified and as diredted by Engineer-In-Charge.
100
-
-
... More
Trimming/pruning of the tree branches comming cross electric power head line HT/LT feeder cleaning the span and making it free from touching the tree branches complete all as specified and as diredted by Engineer-In-Charge. (Note :-(i) All item of LT overhead lines taken together shall be measured as one unit for the payment purpose under this item.(ii) Only such length shall be measured where trees are required to be cut/trimmed as directed by Engineer-In-Charge.(ii) Removing branches from road and diposition at a distance of more than 500 meter)
500
-
-
... More
Supply & fixing in replacement of LED decorative post top lantern light fittings for 360 degree indirect light with IP 65 protection, resistant to impact and corrosion, glare free and better uniformity. Make CG Model LPTO-40-CDL or equivalent Make Philips /Bajaj
20
-
-
... More
S & F Junction Box fof size(H X W X D) 300x200x105 mm made out of Polycarbonate material totally enclosed, dust and vermin proof, rain protected slanted roof top, door pasted with rubber gasket, water tight IP 66 with integrated membranes/metric knockouts for cable entry with cable glands, protection and suitable size of "connectwell" stud teriminal (provision for socket bolting)- 04 Nos suitable for 415 volts, 50 Hz, 3 phase 4 wire internal wiring system including MCB SP 06 amps- 01 No and mounted on tubular/PCC pole with suitableclamps, nuts, bolts including removal of exiting unsv all as specified and directed.
Note :- CA No. shall be embossed on each box by digital printing mechanism.
81
-
-
... More
Supplying and fixing of automatic street light switch using infrared sensor based Nture Switch-, 25 kw equally distributed, 63 Amps,3-pole, Model - Swadeep-02 EC 25 Kw3P for automatic switching of street lights based on LUX level of natural light . The sensor(Nature switch ) along with suitable power contactor rating 63 Amps 3- pole & 40 Amps 2-pole, MCB SP 63 Amps -03 nos and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP54.The contactor suitable to 3- phase load of 25 kw , rating 63 amps 3pole, MCB rating 63 amps SP 03 NOS. Make of Nature switch-Kakatiya Energy systems Pvt Ltd.Hyderbad/ Bajaj/Healer.Contactor-BCH/L&T/Schneider (asper IEC-60947-4-1/IS-13947-4-1), MCB- Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex.
2
-
-
... More
Supplying and fixing of automatic street light switch using infrared sensor based Nture Switch, 08 kw equally distributed, 63 Amps,1-pole, Model - Swadeep-02 EC 8 Kw1P for automatic switching of street lights based on LUX level of natural light . The sensor(Nature switch ) along with suitable power contactor rating 63 Amps 2- pole & 40 Amps 2-pole, MCB SP 63 Amps -02 nos and support terminals should be enclosed in pole/wall mountable enclosure made of rust proof ,electric shock proof, termite proof and FR grade SMC Junction box (Sintex make) confirming to IP54.The contactor suitable to 1- phase load of 08 kw , rating 63 amps 2 pole, MCB rating 63 amps SP 01 NOS. Make of Nature switch-Kakatiya Energy systems Pvt Ltd.Hyderbad/ Bajaj/Healer.Contactor-BCH/L&T/Schneider (asper IEC-60947-4-1/IS-13947-4-1), MCB- Hager/ Schneider/ Legrand/L&T, Circuit Wiring-Polycab/RR Cable /Finolex.
3
-
-
... More
Supply and fixing in replacement for Multistranded three core PVC insulated FRLSH copper conductor cable of size 4sqmm (nominal area), & drawing into hollow street light pole from fitting to distribution box or fitting to over head line all as specified including taking out old existing unserviceable cable.
493
-
-
... More
Disconnecting the LT panel of any size and Cap and repair of complete panel by taking out the cable ,Bus -bar , Voltmtr , Amp mtr ,including wiring and other minor parts, cleaning the complete accessories carefully. Minor repairs shall be rectified Parts/accessories shall be cleaned properly and refixing the parts at its original locations, checking and repair of the internal panel wiring with suitable size of wire and remove the carbon deposited inside the contact, cleaning all other spare parts all as directed by the Engineer-in-charge and reassembled after repair/replacement of following parts.
40
-
-
... More
Supply and fixing in replacement shutters made out of 3.15.00 mm thick mild steel sheet, bent to shape, including taking out old damaged unservicable shutter complete with hinges, handle etc. complete all as directed by Engineer-in-Charge.
11
-
-
... More
Supply and fixing in replacement mild steel medium weight Butt Hinges 100 mm long and fixed with steel screws complete all as specified.
19
-
-
... More
Supply and fixing in replacement mild steel medium weight Butt Hinges 75 mm long and fixed with steel screws complete all as specified.
25
-
-
... More
Supply and fixing in replacement mild steel pressed handles, size 75mm,complete all as specified and as directed by Engineer-in-Charge.
30
-
-
... More
Supply and fixing in replacement mild steel pressed handles, size 100 mm,complete all as specified and as directed by Engineer-in-Charge.
30
-
-
... More
Taking out old underground LT Cable of size 10 sqmm to 120 Sqmm of 3.5 core from LT Panelstrenches/floors /road/wall/ pipe/pole/including taking out loop from trenches upto 1.5 mtrs depth, cutting the faulty end of cable and refixing the cable in original position by using flat aluminium sockets/ thimble/ and insulating the all nacked wires of any size including making connection with MCCB's/ Switches complete all as directed by Engineer-in-Charge. Note : Exacavation for taking out LT cable from will measured and paid separatly.
80
-
-
... More
All as per item No. 72 here-in-before but 150 Sqmm to 630 Sqmm 3.5 core
44
-
-
... More
Material and labour for dismantling of complete panel from foundation and diconnection of all connection from panel and carry out servicing and repairing of LT panel and increase the height of the foundation frame and installation of same after repair complete as direcetd by engr- in charge.
Note :- cost of foundation, MCCB,Cable end joint, Angle Iron reqired for increase the height for LT panel wll be measured and paid seperately.
18
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements