Military Engineer Services Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 6,71,500Document Cost
₹ 3,000Tender Fee
Refer Documents
Description

Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_691005_1Tender No
CE RndD/DLI-28/JODH/2024-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/

GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents

BOQ Items
... More
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section- III
1
-
-
... More
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Section- IV
1
-
-
... More
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Section- V
1
-
-
... More
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Section- VI
1
-
-
... More
Lump sum price worked out by the Contractor for “SECURITY WALL/BOUNDARY WALL, GATE & FENCING” as listed in Schedule ‘A’ Section- VII
1
-
-
... More
Lump sum price worked out by the Contractor for “ROAD/PCC PATH/HARDSTANDING” as listed in Schedule ‘A’ Section- VIII
1
-
-
... More
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Section- IX
1
-
-
... More
Lump sum price worked out by the Contractor for “AIR CONDITIONING & REFRIGERATION” as listed in Schedule ‘A’ Section- X
1
-
-
... More
Lump sum price worked out by the Contractor for “FIRE ALARM SYSTEM” as listed in Schedule ‘A’ Section- XI
1
-
-
... More
Lump sum price worked out by the Contractor for “TRANSFORMER FENCING &STAGING” as listed in Schedule ‘A’ Section- XII
1
-
-
... More
SCHEDULE `A' SECTION - XIII MISC ITEMS (To be quoted by the tenderer)
-
-
-
... More
SITE CLEARANCE
Clearing jungle including uprooting of rank vegetation, grass, brush wood,trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish outside the periphery of the area cleared. by JCB making good the surface and disposal of rubbish out of DLJ area complete all as directed
2360
-
-
... More
INTERNAL WATER SUPPLY
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.
Internal work - Exposed on wall 25 mm nominal dia Pipes
150
-
-
... More
M&L for providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia Pipes
150
-
-
... More
M&L for providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15mm nominal bore
24
-
-
... More
EXTERNAL WATER SUPPLY
M&L for cutting existing DI pipe line of 150mm and inserting Tee of size 150 x 150 x 50mm for tapping including fitting of joints complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
M&L for cutting existing GI pipe line of 50mm and inserting Tee of size 50 x 50 x 50 mm for tapping including fitting of joints complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
M & L for Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design complete all as specified and directed by Engr-in-charge.
2
-
-
... More
Supply and Fixing Openwell submersible pump set of 1.0 HP single Phase, 230 volt, outlet 25 mm, head range minimum 20 mtr, discharge 180 LPM minimum, star rated pump, top suction and including suitable size of copper cable as required complete all as specified and directed.
1
-
-
... More
Supply and fixing testing and commissioning of CI sluice 50mm, PN 1.6, with brass spindle with hand wheel as per IS - 14846 , ISI marked with fittings of approved make complete all as specified and as directed.
2
-
-
... More
Supply,errection, testing and commissioning of slim sheet type butterfly valve 50mm dia (ISI marked) with shperoidal graphite iron disc (SG iron ),with nitrile rubber seal and tested to 1.6 P N including a set of suitable GI flanges,as per BS-10 Table-1,bolts,nuts,GI washer,neoprene rubber gaskets etc.,complete all as directed at site.
1
-
-
... More
Supply and Fixing DOL Starter, single Phase suitable for 1.0 HP openwell submersible pump complete all as specified and directed. Make : Crompton cat part No CSPS110200 or equivalent
1
-
-
... More
INTERNAL ELECTRIFICATION
S & F modular blanking plate
50
-
-
... More
Supply and fixing inbuilt smart sensor based LED 36 watt, auto dimmable ceiling mounted 2x2 ft, having CRCA Sheet Metal Body housing in white powder coated Finish with high translucent diffuser for uniformed Glare Free Light, Elegant Design, IP 20 Protection. Minimum Lumens output of the fitting shall be 5000 Lumens With Efficacy of 100 lm/W, CCT 5700 – 6500K, Surge Protector 4 KV, PF= 0.95 , Necessary mounting arrangements with all accessories complete all as specified and directed by Engr-in-charge.
40
-
-
... More
Supply and fix Telephone/LAN/WAN socket outlet modular type complete all as specified.
98
-
-
... More
Supply and fix Industrial Socket 3 Phase, enclosure with a three pin earth, plug and socket 15 amps complete with one Triple pole MCB 15 amps complete all as directed by Enge-in-Charge
8
-
-
... More
Supply, fixing and connecting up complete DB VTPN 4 way suitable for upto 125 Amp MCCB as incomer, double door 415 V AC, 50 Hz, with a provn to mount MCB TP as outgoing 40 Amp to 100 Amp with highly reliable and tested as per IEC 61439-2, degree of protection IP-54, concealed in wall , islolated neutral bus bar and easy to install complete all as specified and directed by Engr-in-Charge.(MDB for GF LHS & test range)
2
-
-
... More
Supply, fixing and connecting up complete DB VTPN 6 way suitable for upto 250 Amp MCCB as incomer, double door 415 V AC, 50 Hz, with a provn to mount MCB TP as outgoing 40 Amp to 100 Amp with highly reliable and tested as per IEC 61439-2, degree of protection IP-54, concealed in wall , islolated neutral bus bar and easy to install complete all as specified and directed by Engr-in-Charge.(MDB for GF RHS, FF LHS& RHS)
3
-
-
... More
M&L MCCB 4 Pole, 415 volts, fixed type 100 Amps with breaking capacity 25 KA ,confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings, adjustable thermal setting, suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.(I/c for test range MDB)
1
-
-
... More
M&L MCCB 4 Pole, 415 volts, fixed type 125 Amps with breaking capacity 25 KA ,confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings, adjustable thermal setting, suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.(I/c for GF LHS MDB)
1
-
-
... More
M&L MCCB 4 Pole, 415 volts, fixed type 160 Amps with breaking capacity 25 KA ,confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings, adjustable thermal setting, suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.(I/c for FF LHS MDB)
1
-
-
... More
M&L MCCB 4 Pole, 415 volts, fixed type 200 Amps with breaking capacity 25 KA ,confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings, adjustable thermal setting, suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.(I/c for FF RHS MDB)
1
-
-
... More
M&L MCCB 4 Pole, 415 volts, fixed type 250 Amps with breaking capacity 25 KA ,confirming to IEC-60947-II with adjustable overload settings, adjustable short circuit settings, adjustable thermal setting, suitable for VTPN DB including connecting up complete all as specified and directed by Engr-in-Charge.(I/c for GF RHS MDB)
1
-
-
... More
M&L for Rigid non-metalic PVC conduit 25mm dia consealed in walls for Telephone/LAN/WAN exclusive of boxes (junction/terminal) but inclusive of all fees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as directed.
385
-
-
... More
M&L for Rigid non-metalic PVC conduit 32mm dia consealed in walls for Telephone/LAN/WAN exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as directed.
300
-
-
... More
External Electrification
M&L for Drop out fuse set switches mounted on insulator for 11000 volts complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
Supplying, installation and testing with proper foundation of 11 KV, 630A, 26 KA for 3 Sec SF6 insulated, outdoor type 6 way Ring main unit, extensible motorised and manual operated, in combination of 2 No. VCB modules (As a incomer) & 4 No VCB modules (As a outgoing) consisting of copper busbar in SF6 insulated Grade) stainless steel enclosure of thickness 3.15 mm with manometer. Fixed on the tank. Both the incomer should be interlocked with each other. The Breaker shall have mechanical ON/OFF indicator with hand trip device and spring chagrining, spring release coil, auxiliary switch of 2 NO +2NC. The HV switchgear and control gear should be confirming to IEC-62271-100, IEC-62272-200-2003 & IEC-60694-1996. The RUM gas tank should be internal arc tested for 26 KA for 1 second with IAC-AFL classification for gas tank. The complete RMU and cable chamber should be covered by minimum two doors to have ingress protection of minimum IP54. The RMU design should support site replaceable HT cable bushing and vacuum interrupter of VCB should be RMU manufacture’s.
(a) RMU should have microprocessor with self powered numerical relay with over current, earth fault, short circuit protection, voltmeter and amp meter with each VCB.
(b) Protection CT shall be of Burden 2.5VA, ration 100-1A class of accuracy class 5P10 for O/C and E/F protection for each VCB-03 Nos. (c) CT ration is indicative and may vary during detailed engineering, (d) Manometer for each tank -01 No
(e) Voltage passage indicator for each feeder -01 No
(f) Fault passage indicator for each feeder -01 No
(g) Right angle boots for all the feeder modules.
(h) Basic insulation level for complete system shall be 28 KV (RMS)/75 KV (Peak) Note: (i) RMU shall be placed on PCC platform, size recomended by OEM /Engr-in-Charge. (ii) Cost for Excavation, earth work, PCC,brick work and plastring etc of PCC plateform shall be included in the quoted rate by the contractor.
1
-
-
... More
M&L for 63/100 KVA transformer for safely lifted and shifted by the crane for a distance not exceeding 2 Km within the premises etc complete all as specified and as directed.
Note :- (i) Any damages happened in transformer during lifting/ shifting/ installation work, the same will be rectified by the contractor without any extra cost to the Govt
(ii) Transformer shall be placed on PCC platform, size recomended by Engr-in-Charge. (iii) Cost for Excavation, earth work, PCC,brick work and plastring etc of PCC plateform shall be included in the quoted rate by the contractor
1
-
-
... More
Supply, installed, commissioning and testing of outdoor type LT panel board of suitable size for below mentioned incoming ACB and outgoing MCCB electronic/micro processor release with one Blank compartment for suitable outgoing, KIOSK factory made (CPRI approved) double door type on front & back side openable with locking arrangement, main panel board fabricated out of CRCA MS sheet 3.15 mm thick, 45 x 45 x 6 mm angle iron and Tee section frame, dust and vermin proof, complete with 4 Nos Aiuminium bus bar 800 amp Vertical position mounted on porcelain insulators, having capacity suitable for main incoming ACB, totally enclosed, chamber for protection 3 phase 440 volt with suitable size of PVC insulated copper cable control wiring and duly mounted on PCC (1:2:4) foundation/platform of height 450mm with suitable size of bolts, nuts & washers. The panel board shall be powder coated with synthetic enamel paint over a coat of red oxide zinc chrome primer complete including the followings : -
(i) Incoming LT ACB 415 volts, 4 pole, 630 Amps, Manual Drawout type with Microprocessor Release with load setting 90/75% - 01 Nos.
(ii) Outgoing MCCB 415 volts, 4 pole 25 KA 315 Amps - 01 Nos.
(iii) Outgoing MCCB 415 volts, 4 pole 25 KA 250 Amps - 01 Nos.
(iv) Outgoing MCCB 415 volts, 4 pole 25 KA 200 Amps - 01 Nos.
(v) Outgoing MCCB 415 volts, 4 pole 25 KA 160 Amps - 02 Nos.
(vi) Outgoing MCCB 415 volts, 4 pole 16 KA 125 Amps - 01 Nos.
(vii) Digital Volt meter 0 - 500 volt - 01 Nos. Amp meter 0 - 500 Amps with in-built CT's and selector switch - 01 set also with three phase indicating lamp
1
-
-
... More
Supply, installed, commissioning and testing of outdoor type LT panel board of suitable size for below mentioned incoming and outgoing MCCB adjustable thermal setting with one Blank compartment for suitable outgoing, KIOSK factory made (CPRI approved) double door type on front & back side openable with locking arrangement, main panel board fabricated out of CRCA MS sheet 3.15 mm thick, 45 x 45 x 6 mm angle iron and Tee section frame, dust and vermin proof, complete with 4 Nos Aiuminium bus bar Vertical position mounted on porcelain insulators, having capacity suitable for main incoming MCCB, totally enclosed, chamber for protection 3 phase 440 volt with suitable size of PVC insulated copper cable control wiring and duly mounted on PCC (1:2:4) foundation/platform of height 450mm with suitable size of bolts, nuts & washers. The panel board shall be powder coated with synthetic enamel paint over a coat of red oxide zinc chrome primer complete including the followings :-
(i) Incoming MCCB 415 volts, 4 pole 16 KA 125 Amps - 01 Nos.
(ii) Outgoing MCCB 415 volts, 4 pole 16 KA 63 Amps - 01 Nos.
(iii) MCB SPN 10 Amp -01 No
(iv) Digital Volt meter 0 - 500 volt - 01 Nos. Amp meter 0 - 500 Amps with in-built CT's and selector switch - 01 set also with three phase indicating lamp (v) Single Phase Road light timer + Contactor 10 Amp + MCB SPN 10 Amp -01 Nos.
1
-
-
... More
Supply and fix pole mounting type junction box factory made of size 333x233x155 mm of RP sheet, shockproof and rustproof, fire retardant as per IS:11731 with front openable hinged door, locking arrangement with 4 Nos aluminium bus bas 40 Amp rating mounted on porecelian insulator, cable gland, lugs consisting DIN type rails for fixing MCB SP including one No MCB SP 20 AMP, mild steel plat iron clamp made out of 40x4 mm FI and nut, bolts & wahsers duly painted clamps, nuts and bolts with two coat of synthetic enamel paint over a coat of red oxide primer comopletye all as specified and directed.
8
-
-
... More
M&L for wiring 3 core 2.5 sqmm FRLS PVC insulated copper conductor cable in surface/ recessed including PVC/Steel conduit of 20 mm dia as required complete all as specified and directed by Engineer-in-charge.
60
-
-
... More
M&L sand cushioning to PVC cable with river/tibba sand and punning to provide required cover complete all as directed by Engineer-in-Charge.
(Note :- For the purpose of payment only punned thickness will be measured).
94.17
-
-
... More
M & L for boring in any type of soil under road 1.5 mtr below the top surface of road by conventional method complete for passing through 40 mm to 150 mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed.
Note :- Pipe will be paid and measured seperately. Any damage to existing cale/ pipe line of ant type will made good by the contractor without any extra cost.
20
-
-
... More
M&L for cable path indicator 15cm dia circular type, made out of cast Iron duly embedded with size , voltage and type of HT cable with arrow mark indicting direction of the cable in brown colour fixed on ISA 40x40x6mm angle iron support embedded including in PCC 1:2:4 type B1 (300x300x400mm) and steel surface painted with two coats of anti corrosive paint over a coat of red oxide primer including necessary earth work all as specified and directed.
5
-
-
... More
M&L for cable path indicator 15cm dia circular type, made out of cast Iron duly embedded with size , voltage and type of LT cable with arrow mark indicting direction of the cable in blue colour fixed on ISA 40x40x6mm angle iron support embedded including in PCC 1:2:4 type B1 (300x300x400mm) and steel surface painted with two coats of anti corrosive paint over a coat of red oxide primer including necessary earth work all as specified and directed.
10
-
-
... More
BOUNDARY WALL
M&L for providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the concrete of M-25 grade with minimum cement content of 330 Kg/Cum.
1
-
-
... More
All as per item No 20 above but above plinth level upto floor V level , Concrete of M25 grade with minimum cement content of 330 kg /cum
32
-
-
... More
M&L for applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer complete all as specified & directed by Engineer-In-Charge Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm)
2850
-
-
... More
PCC PATH
M&L for preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
2450
-
-
... More
M&L for laying, spreading and compacting stone aggregate as in hardcore of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/ vibratory roller 8-10 tonne capacity in stages to proper grade and camber,applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density complete all as specified and directed by Engineer-in-Charge.
321
-
-
... More
M&L for providing and laying Cement concrete prepared with batch mixing machine design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie barswherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).
321
-
-
... More
M&L for providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners,all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillersshall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.)
75
-
-
... More
M&L for providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction ofthe Engineer-in-Charge.Using grade 'A' sealing compound conforming to IS: 1834
75
-
-
... More
M&L for Moorum filling in Sub Base duly compacted/consolidated complete all as specified and directed
321
-
-
... More
SEWAGE DISPOSAL
M&L for DWCPE (SN8) 180 (OD)/163(ID) mm diameter Pipes laid in trenches complete all specified and directed.
122
-
-
... More
M&L for on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 30 users.
1
-
-
... More
M&L for on site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc., complete for 10 users.
1
-
-
... More
M&L for construction of sokage wells excavation, in any type of soil, foundaton in PCC 1:3:6, walls of honey combled masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 3 M dia X 3.0 M effective depth complete all as specified and directed by Engineer-in-Charge.
1
-
-
... More
M&L for construction of sokage wells excavation, in any type of soil, foundaton in PCC 1:3:6, walls of honey combled masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 2.4 M dia X 3.0 M effective depth complete all as specified and directed.
1
-
-
... More
FIRE ALARM SYSTEM
Supply installation testing and commissioning Micro processor based. Intelligent Addressable Main Fire alarm panel, Central Processing Unit ,with the following loop module and with each loop capacity of 120 detector per loop with total of 240 detectors and devices with loop length up to 2 KM, network communication card, minimum 320 character graphics, LCD display with touch screen or other keypad and 1000 event history logs in the non volatile memory (EEPROM) power supply unit at 230+ 5 % V, 48 Hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout logs and facility to have integration with analog voice evacuation system( which is part of the schedule of work under SH: PA System) and shall be complete with all accessories .The panel should be compatible for integration with IBMS system with open protocol Bacnet/IP, complete as per specs and as required for two loops panel.
2
-
-
... More
Supply installation testing and commissioning of response indicator on surface/ recessed MS box having two LED, metallic cover complete with all connections etc as required
64
-
-
... More
Supply installation testing and commissioning of intelligent addressable thermal detector with rate of rise cum fix temprature thermistor complete with base as required
128
-
-
... More
Supplying and laying of 2x1.5 sqmm fire survival armoured cable 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of cross linkable ethylene propylene rubber (EPR) insulation and LSZH inner bedding steel wire armouring & LSZH outer sheath complete as required.
1023
-
-
... More
Transformer Fencing & Staging
M&L for providing and fixing hard drawn steel wire fabric 75x25 mm mesh of weight not less than 7.75 Kg per sqm welded to angle iron frame includigng priming coat with approved steel primer all complete.
126
-
-
... More
M&L for supplying, stacking, spreading and levelling at site 63 mm to 45 mm size stone aggregate as directed by Engineer-in-charge.
10
-
-
... More
Fume Hood
M&L for Design, Build, Detailed Engineering, Supply, Installation, Testing, Commissioning and validation of fume hood system.
The bidder shall be responsible to fume hood system facility in line with design layout enclosed, its fabrication and technical support at site, supervision of other construction, testing, commissioning and validation.
The Fume hood system with above specification shall be installed in the following rooms.
High-capacity walk-in-Fume hoods with exhaust duct of appropriate diameter and apporx. 20-meter length-01 No. (for Chemistry Lab) Size: 2500mm x depth 1500mm x height 2250 mm.
1
-
-
... More
Desert Sand
M&L for Supplying ,Stacking and levelling Desert Sand locally available complete all as directed by Engineer-in-charge
10000
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%