Military Engineer Services Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date25 Feb 2025
Closing Date18 Mar 2025
Tender Amount₹ 46,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No. 1 here in before but for 200 KVA DG.

1

-

-

... More
M&L Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering, etc. to be prepared for structural works including necessary fastening, fabrication and fixing complete all as specified and as directed by Engr-in-Charge.

950

-

-

... More
M&L Mild steel, plain, black sheet in wall cladding, steel gates, and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required of sheet thickness spprox 3.50 mm complete all as specified and as directed by Engineer-in-Charge.

45

-

-

... More
Taking out old under ground LT /HT XLPE cable of any size for finding out fault from trenches/wall/roof/road/pipe/pole/ including taking out of PCC cable cover complete all as specified and as directed by Engineer-in-Charge. (Excavation, earth work shall be measured and paid for separately under appropriate item).

310

-

-

... More
Supply and laying XLPE HT Cable of size 95 Sqmm, 3 core, 11 KV ‘E’ heavy duty with XLPE insulated stranded aluminium conductor served with an inner sheathening of PVC tape armoured with Galvanized steel strip or wire and over all PVC Sheathed conforming to IS- 7098 (Part-II) with latest amendments laid in trenches/fixed to wall/pole/laid in floor including necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge. (Excavation, earth work, brick & sand cushioning shall be measured and paid for separately under appropriate item).

60

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified.

50

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified.

50

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified.

50

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified.

50

-

-

... More
Supply and lay cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified.

50

-

-

... More
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation & getting out in for laying of cable complete as specified.

80

-

-

... More
Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete.

40

-

-

... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified

11

-

-

... More
Material and labour for dry tibba sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose.

29

-

-

... More
Supply and lay un reinforced precast concrete cable covers class HV, type 1, flat of size 300 x 180 x 40 mm. complete all as specified and directed.

280

-

-

... More
Supply and lay un reinforced precast concrete cable covers class LV, type 1, flat of size 250 x 150 x 40 mm. complete all as specified and directed.

1350

-

-

... More
S&F in replacement signage boards size appx made of acrylic sheet transparent 5 mm thick suitable for engraving letters/numerics/symbols well frames including suitable size MS angles, fitting work, electric connections etc comple all as directed.

300

-

-

... More
S&F Led lit english letters (in capitals)/numerics/symbols of size appx 20-30 cm height of font type Halvetica/Arial or else duly specified by Engr-in-Charge suitable for signage boards for E&M installations complete with fitting/electric connection complete all as specified.

250

-

-

... More
S&F Led lit acrylic english letters (in capitals)/numerics/symbols of size appx 12-18 cm high of font type Halvetica/Arial or else duly specified by Engr-in-Charge suitable for signage boards for E&M installations complete with fitting/electric connection complete all as specified.

246

-

-

... More
S&F in replacement LED post top lantern 20 W made in cast aluminium spigot housing with decorative opal polycarbonate diffuser and IP65 protection complete with necessary electrical fiitings and accessories as directed.

2

-

-

... More
Material and Labour in replacement of heat shrinkable straight through joint suitable for HT XLPE cable of size 95 Sqmm 3 core armoured 11000 volt grade heavy duty complete all as speicified and directed by Engineer-in-Charge

5

-

-

... More
Material and Labour in replacement of heat shrinkable end termination joint outdoor type suitable for HT XLPE cable of size 95 Sqmm 3 core armoured 11000 volt grade heavy duty complete all as speicified and directed by Engineer-in-Charge

5

-

-

... More
M&L repair/servicing of LT panel of min size approx 1000X700X450 mm including dismantling the panel from existing foundation, taking out all mountings including MCCBs, MCBs, CTs, minor items etc disconnecting incomming and outgoing cables, dismantling of voltmeters and ammeters, replacement of all copper/aluminium thimbles of any size, replacement of defective/damaged bus bar of existing size, replacement of all door locks, replacement of all indicator lamps, complete painting with quick-drying enamel paint standard ASA61 Medium Grey, replacement of burnt electrical connections, fitting back all mountings and electrical connections etc & fitting back the panel on existing MS angle frame including necessary fabrication and complete painting of panel with two coats of synthetic enamel paint complete all as specified and as directed by Engineer-in-Charge. Note:- 1. Payment of minor items including copper and aluminium thimbles, defective bus bars, door locks, indicator lamps etc are deemed to be included in the quoted rates. 2. Painting work is deemed to included in the quoted rates.

5

-

-

... More
Supply and fixing Street light bracket made out of 40 mm dia GI tubing medium grade made to shape 1.5 Mtr long with fixing arrangements for LED fitting duly painted with two coats of synthetic aluminium paint over a coat of primer including MS clamp and back plates fabricated from steel section including nuts , bolts , washer etc complete all as specified.

5

-

-

... More
Supply and replacement of battery maintenance free 12 volts 80 AH including initial charge and connected DC cable thimble nut, bolts etc including testing complete all as directed by engineer-in-charge.

4

-

-

... More
Supply and fix in replacement of power contactor 100 Amp, 4 Pole, 415 Volts with in built auxiliary contact blocks with fitting suitable for AMF panel 100 KVA including all necessary fittings as per existing model complete all as specified and directed by Engineer in charge

1

-

-

... More
Supply and fix in replacement of power contactor 200 Amp, 4 Pole, 415 Volts with auxiliary contact blocks with fittings including all necessary fittings as per existing model complete all as specified and directed by Engineer in charge

1

-

-

... More
Supply and fix in replacement of power contactor 250 Amp, 4 Pole, 415 Volts with auxiliary contact blocks with fitting suitable for AMF panel 250 KVA including all necessary fittings as per existing model complete all as specified and directed by Engineer in charge

1

-

-

... More
Supply and fix in replacement of power contactor 400 Amp, 4 Pole, 415 Volts with auxiliary contact blocks with fitting suitable for AMF panel 400 KVA including all necessary fittings as per existing model complete all as specified and directed by Engineer in charge

1

-

-

... More
Supply and fix in replacement of power contactor 1000 Amp, 4 Pole, 415 Volts with auxiliary contact blocks with fitting suitable for AMF panel 1000 KVA including all necessary fittings as per existing model complete all as specified and directed by Engineer in charge.

1

-

-

... More
S & F in replacement MCCB, 4 pole, 415 Volts, ultimate breaking capacity 50 KA, 100% lcs, 50 Hz, with thermal magnetic release complete all as specified and directed of capacity 400 Amp.

1

-

-

... More
S & F in replacement MCCB, 4 pole, 415 Volts, ultimate breaking capacity 25 KA, 100% lcs, 50 Hz, with thermal magnetic release complete all as specified and directed of capacity 250 Amp.

1

-

-

... More
S & F in replacement MCCB, 4 pole, 415 Volts, ultimate breaking capacity 25 KA, 100% lcs, 50 Hz, with thermal magnetic release complete all as specified and directed of capacity 200 Amp.

1

-

-

... More
S & F in replacement MCCB, 4 pole, 415 Volts, ultimate breaking capacity 16 KA, 100% lcs, 50 Hz, with thermal magnetic release complete all as specified and directed of capacity 100 Amp.

1

-

-

... More
S & F in replacement MCCB, 4 pole, 415 Volts, ultimate breaking capacity 16 KA, 100% lcs, 50 Hz, with thermal magnetic release complete all as specified and directed of capacity 63 Amp.

1

-

-

... More
Supply, install, test and commissioning LT feeder Piller/ Panel board of suitable size, cubical, outdoor type, CPRI approved, duly painted with seven tank powder coat painting process, free floor standing fabricated made out of 3.15 mm thick CRCA sheet to accommodate all accessories/fittings, compartmentalized in construction to accomodate all accessories incomming and outgoing MCCBs, MCBs & TPN bus bars of rating not less than 1.5 times the rated cap of incommer MCCB/ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50X50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incomming more as well as outgoing MCCBs shall have copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for terminaton of incomming and outgoing cables. All extension links/interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channel of size 50X50X6 mm and min height of 70 cm from ground level. A detatchable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands. The above panel shall be front and back openable lockable by key from both sides and shall have louvers air vent gasket for natural flow of air 3mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, complete as specified and consisting the following switch gears and accessories:- (i) Incommer :- MCCB 630 Amp 50 KA , 4 pole -01 No (ii) Outgoing:- a) MCCB 250 Amp 25 KA , 4 pole -01 No b) MCCB 160 Amp 25 KA , 4 pole -01 No c) MCCB 125 Amp 25 KA , 4 pole -01 No d) MCCB 100 Amp 16 KA , 4 pole -01 No e) Onload changeover 630 Amp -01 No (iii) Digital Multi function Meter-01 Nos (iv) LED type RYB Phase indicator-01 Set (v) Heat resistance sleeve (vi) Bus bar with colour code ampere rating min 1.5 timesrated cap of incommer MCCB. (vii) Bus bar support epoxy 50mm (viii) Suitable size Brass nut bolt washer (ix) Sheet metal work including fabrication, PCC foundation etc (x) Complete wiring with copper cable, thimble etc. Note:- Drawing shall be duly approved by Engr-in-Charge before manufaturing of panel.

1

-

-

... More
Supply, install, test and commissioning LT feeder Piller/ Panel board of suitable size, cubical, outdoor type CPRI approved , duly painted with seven tank powder coat painting process, free floor standing fabricated made out of 3.15 mm thick CRCA sheet to accommodate all accessories/fittings, compartmentalized in construction to accomodate all accessories incomming and outgoing MCCBs, MCBs & TPN bus bars of rating not less than 1.5 times the rated cap of incommer MCCB/ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50X50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incomming more as well as outgoing MCCBs shall have copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for terminaton of incomming and outgoing cables. All extension links/interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channel of size 50X50X06 mm and min height of 70 cm from ground level. A detatchable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands. The above panel shall be front and back openable lockable by key from both sides and shall have louvers air vent gasket for natural flow of air 3mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, complete as specified and consisting the following switch gears and accessories:- (i) Incommer :- MCCB 630 Amp 50 KA , 4 pole -01 No (ii) Outgoing:- a) MCCB 400 Amp 50 KA , 4 pole -02 No b) MCCB 100 Amp 16 KA , 4 pole -01 No (iii) Digital Multi function Meter-01 Nos (iv) LED type RYB Phase indicator-01 Set (v) Heat resistance sleeve (vi) Bus bar with colour code ampere rating min 1.5 timesrated cap of incommer MCCB. (vii) Bus bar support epoxy 50mm (viii) Suitable size Brass nut bolt washer (ix) Sheet metal work including fabrication, PCC foundation etc (x) Complete wiring with copper cable, thimble etc. Note:- Drawing shall be duly approved by Engr-in-Charge before manufaturing of panel.

1

-

-

... More
Supply, install, test and commissioning LT feeder Piller/ Panel board of suitable size, cubical, outdoor type CPRI approved, duly painted with seven tank powder coat painting process, free floor standing fabricated made out of 3.15 mm thick CRCA sheet to accommodate all accessories/fittings, compartmentalized in construction to accomodate all accessories incomming and outgoing MCCBs, MCBs & TPN bus bars of rating not less than 1.5 times the rated cap of incommer MCCB/ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50X50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incomming more as well as outgoing MCCBs shall have copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for terminaton of incomming and outgoing cables. All extension links/interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channel of size 75X40 mm50X50X6 mm bottom for entry of armoured cable of adequate size with glands and min height of 70 cm from ground level. The above panel shall be front and back openable lockable by key from both sides and shall have louvers air vent gasket for natural flow of air 3mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, complete as specified and consisting the following switch gears and accessories:- (i) Incommer :- MCCB 630 Amp 50 KA , 4 pole -01 No (ii) Outgoing:- a) MCCB 400 Amp 50 KA , 4 pole -01 No b) MCCB 315 Amp 36 KA , 4 pole, -01 No c) MCCB 200 Amp, 25 KA, 4 Pole - 02 No e) Onload changeover 630 Amp- 01 No (iii) Digital Multi function Meter-01 Nos (iv) LED type RYB Phase indicator-01 Set (v) Heat resistance sleeve (vi) Bus bar with colour code ampere rating min 1.5 timesrated cap of incommer MCCB. (vii) Bus bar support epoxy 50mm (viii) Suitable size Brass nut bolt washer (ix) Sheet metal work including fabrication, PCC foundation etc (x) Complete wiring with copper cable, thimble etc. Note:- Drawing shall be duly approved by Engr-in-Charge before manufaturing of panel.

1

-

-

... More
Supply, install, test and commissioning LT feeder Piller/ Panel board of suitable size, cubical, outdoor type CPRI approved, duly painted with seven tank powder coat painting process, free floor standing fabricated made out of 3.15 mm thick CRCA sheet to accommodate all accessories/fittings, compartmentalized in construction to accomodate all accessories incomming and outgoing MCCBs, MCBs & TPN bus bars of rating not less than 1.5 times the rated cap of incommer MCCB/ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50X50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incomming more as well as outgoing MCCBs shall have copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for terminaton of incomming and outgoing cables. All extension links/interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channel of size 50X50X6 mm. A detatchable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands and min height of 70 cm from ground level. The above panel shall be front and back openable lockable by key from both sides and shall have louvers air vent gasket for natural flow of air 3mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, complete as specified and consisting the following switch gears and accessories:- (i) Incommer :- MCCB 315 Amp 35 KA , 4 pole -01 No (ii) Outgoing:- a) MCCB 200 Amp 25 KA , 4 pole -01 No b) MCCB 125 Amp 25 KA , 4 pole -02 No c) MCCB 100 Amp 16 KA , 4 pole -01 No d) Onload changeover 320 Amp -01 No (iii) Digital Multi function Meter-01 Nos (iv) LED type RYB Phase indicator-01 Set (v) Heat resistance sleeve (vi) Bus bar with colour code ampere rating min 1.5 timesrated cap of incommer MCCB. (vii) Bus bar support epoxy 50mm (viii) Suitable size Brass nut bolt washer (ix) Sheet metal work including fabrication, PCC foundation etc (x) Complete wiring with copper cable, thimble etc. Note:- Drawing shall be duly approved by Engr-in-Charge before manufaturing of panel.

1

-

-

... More
Supply, install, test and commissioning LT feeder Piller/ Panel board of suitable size cubical, outdoor type CPRI approved, duly painted with seven tank powder coat painting process, free floor standing fabricated made out of 3.15 mm thick CRCA sheet to accommodate all accessories/fittings, compartmentalized in construction to accomodate all accessories incomming and outgoing MCCBs, MCBs & TPN bus bars of rating not less than 1.5 times the rated cap of incommer MCCB/ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50X50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incomming more as well as outgoing MCCBs shall have copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for terminaton of incomming and outgoing cables. All extension links/interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channel of size 50X50X6 mm. A detatchable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands and min height of 70 cm from ground level. The above panel shall be front and back openable lockable by key from both sides and shall have louvers air vent gasket for natural flow of air 3mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, complete as specified and consisting the following switch gears and accessories:- (i) Incommer :- MCCB 250 Amp 25 KA , 4 pole, -01 No (ii) Outgoing:- a) MCCB 63 Amp 16 KA , 4 pole -03 No b) MCCB 100 Amp 16 KA , 4 pole -03 No (iii) Digital Multi function Meter-01 Nos (iv) LED type RYB Phase indicator-01 Set (v) Heat resistance sleeve (vi) Bus bar with colour code ampere rating min 1.5 timesrated cap of incommer MCCB. (vii) Bus bar support epoxy 50mm (viii) Suitable size Brass nut bolt washer (ix) Sheet metal work including fabrication, PCC foundation etc (x) Complete wiring with copper cable, thimble etc. Note:- Drawing shall be duly approved by Engr-in-Charge before manufaturing of panel.

1

-

-

... More
Supply, install, test and commissioning LT feeder Piller/ Panel board of suitable size, cubical ,outdoor type, duly painted with seven tank powder coat painting process, free floor standing fabricated made out of 3.15 mm thick CRCA sheet to accommodate all accessories/fittings, compartmentalized in construction to accomodate all accessories incomming and outgoing MCCBs, MCBs & TPN bus bars of rating not less than 1.5 times the rated cap of incommer MCCB/ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50X50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incomming more as well as outgoing MCCBs shall have copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for terminaton of incomming and outgoing cables. All extension links/interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channel of size 50X50X6 mm. A detatchable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands and min height of 70 cm from ground level. The above panel shall be front and back openable lockable by key from both sides and shall have louvers air vent gasket for natural flow of air 3mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, complete as specified and consisting the following switch gears and accessories:- Note:- Drawing shall be duly approved by Engr-in-Charge before manufaturing of panel. (i) Incommer :- MCCB 250 Amp 25 KA , 4 pole, -01 No (ii) Outgoing:- a) MCCB 200 Amp 25 KA , 4 pole, -02 No b) MCCB 100 Amp 16 KA , 4 pole -01 No (iii) Digital Multi function Meter-01 Nos (iv) LED type RYB Phase indicator-01 Set (v) Heat resistance sleeve (vi) Bus bar with colour code ampere rating min 1.5 timesrated cap of incommer MCCB. (vii) Bus bar support epoxy 50mm (viii) Suitable size Brass nut bolt washer (ix) Sheet metal work including fabrication, PCC foundation etc (x) Complete wiring with copper cable, thimble etc. Note:- Drawing shall be duly approved by Engr-in-Charge before manufaturing of panel.

1

-

-

... More
Supply, install, test and commissioning LT feeder Piller/ Panel board of suitable size, cubical, outdoor type, duly painted with seven tank powder coat painting process, free floor standing fabricated made out of 3.15 mm thick CRCA sheet to accommodate all accessories/fittings, compartmentalized in construction to accomodate all accessories incomming and outgoing MCCBs, MCBs & TPN bus bars of rating not less than 1.5 times the rated cap of incommer MCCB/ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50X50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incomming more as well as outgoing MCCBs shall have copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for terminaton of incomming and outgoing cables. All extension links/interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channel of size 50X50X6 mm. A detatchable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands and min height of 70 cm from ground level. The above panel shall be front and back openable lockable by key from both sides and shall have louvers air vent gasket for natural flow of air 3mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, complete as specified and consisting the following switch gears and accessories:- (i) Incommer :- MCCB 400 Amp 50 KA , 4 pole -01 No (ii) Outgoing:- a) MCCB 250 Amp 25 KA , 4 pole -02 No b) MCCB 200 Amp 25 KA , 4 pole -01 No c) MCCB 100 Amp 16 KA , 4 pole -01 No d) Onload changeover 400 Amp - 01 No (iii) Digital Multi function Meter-01 Nos (iv) LED type RYB Phase indicator-01 Set (v) Heat resistance sleeve (vi) Bus bar with colour code ampere rating min 1.5 timesrated cap of incommer MCCB. (vii) Bus bar support epoxy 50mm (viii) Suitable size Brass nut bolt washer (ix) Sheet metal work including fabrication, PCC foundation etc (x) Complete wiring with copper cable, thimble etc. Note:- Drawing shall be duly approved by Engr-in-Charge before manufaturing of panel.

1

-

-

... More
Supply, install, test and commissioning LT feeder Piller/ Panel board of suitable size,cubical, outdoor type, duly painted with seven tank powder coat painting process, free floor standing fabricated made out of 3.15 mm thick CRCA sheet to accommodate all accessories/fittings, compartmentalized in construction to accomodate all accessories incomming and outgoing MCCBs, MCBs & TPN bus bars of rating not less than 1.5 times the rated cap of incommer MCCB/ACB and outgoing feeder. The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator of size not less than 50X50 mm conical type at an interval of not more than 500 mm through out the length of the TPN bus bar. The incomming more as well as outgoing MCCBs shall have copper extension links of current carrying capacity not less than 1.5 times the rated capacity of individual feeders. The extension links shall be supported on DMC/ Epoxy insulators having provision for terminaton of incomming and outgoing cables. All extension links/interconnection shall be insulated with heat shrinkable colour coded sleeves. The cubicle shall have a bottom channel of size 50X50X6 mm. A detatchable predrilled gland plate of thickness not less than 3 mm thick should be used at the bottom for entry of armoured cable of adequate size with glands and min height of 70 cm from ground level. The above panel shall be front and back openable lockable by key from both sides and shall have louvers air vent gasket for natural flow of air 3mm XLPE adhesive type gasket shall be used to make panel weather, dust and vermin proof with IP 65 degree of protection, complete as specified and consisting the following switch gears and accessories:- (i) Incommer :- MCCB 630 Amp 50 KA , 4 pole - 01 No (ii) Outgoing:- a) MCCB 250 Amp 25 KA , 4 pole -02 No b) MCCB 315 Amp 35 KA , 4 pole -01 No c) MCCB 100 Amp 16 KA , 4 pole -02 No d) Onload changeover 630 Amp - 01 No (iii) Digital Multi function Meter-01 Nos (iv) LED type RYB Phase indicator-01 Set (v) Heat resistance sleeve (vi) Bus bar with colour code ampere rating min 1.5 timesrated cap of incommer MCCB. (vii) Bus bar support epoxy 50mm (viii) Suitable size Brass nut bolt washer (ix) Sheet metal work including fabrication, PCC foundation etc (x) Complete wiring with copper cable, thimble etc. Note:- Drawing shall be duly approved by Engr-in-Charge before manufaturing of panel.

1

-

-

... More
S&F 630 amps, 4-pole Motorized electrically operated draw out with cradle type 3 position Air Circuit Breaker of fault breaking capacity 50 KA (Ics= Icu upto 433V) manually/automatic operated, fitted with interlocked door, automatic safety shutters, mechancal ON/OFF and service /test/ isolated position indicators and frame earthing contact, confirming to IS complete all as specified and as directed by Engr-in-Charge.

1

-

-

... More
Material and labour for Cement Concrete 1:2:4 type B1 using 20mm graded stone aggregate for pole base foundation and coping complete all as specified.

1

-

-

... More
M&L in repair cement concrete PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in pole foundation all as specified

2

-

-

... More
S & F in replacement Engine Start Relay, 24 Volt DC, For Gensets 3 Cranks on & Off 0-30 Sec Each Setable complete all as specified and directed. Make : - Teknika/C&S/EL measure/Procom/L&T/Schneider/AE/GE

3

-

-

... More
M&L in replacement for Earthing complete with galvanised steel earth plate electrode 60 X 60 cm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to and inclduing GI Strip 25x4 mm as earthing lead, by means of bolts, nuts, check nuts and washers of galvanised iron all as shown in electrical plate No 5 of MES SSR Part I and testing on completion inclduing excavation and earth work in any type of soil, PCC (1:3:6) type C1 chamber, and cover 6 mm thick in cement concrete (1:2:4) type B1, funnel with wire mesh, GI watering pipe 20mm dia medium grade and terminal lugs complete all as specified and directed with earth resistance not more than 5.0 OHMS. Note- In case earth resistance more than 5.0 ohms, the contractor will do re earthing at no extra cost

6

-

-

... More
M&L in replacement for Earth continuity conductor or main earthing lead fixed to walls on batten or recess or chases or burried in ground or drawn in conduit/pipes or fixed to poles or any other indicated situation for loop earthing etc as required 25x4mm galvanised iron strip all as specified.

10

-

-

... More
M&L in replacement for Earth continuity conductor or main earthing lead fixed to walls on batten or recess or chases or burried in ground or drawn in conduit/pipes or fixed to poles or any other indicated situation for loop earthing etc as required 25x4mm copper strip all as specified.

10

-

-

... More
Supply and installation in replacement 10 Mtr hot dip galvanised octagonal poles with 155mm bottom & 70 mm top A/F made up of 3 mm thick HT sheet alongwith base plate of size 250x250x16 mm (Door with Hinge) with 4 nos of M24 x 750 mm high 'J' type EN 8 grade Including foundation of PCC 1:3:6 ,& bolts along with template with inbuilt junction box having 6 A single pole "B" class mcb including 1.5 m long Hot dip galvanised single arm bracket made up of 40 NB dia GI pipe suitable to mount on pole having top 70 mm A/F complete all as specified and as directed by Engineer-in-Charge.

6

-

-

... More
S&F in repairs 11 KV HT feeder pillar box factor made cubical type dust proof, CPRI approved, out door type, IP-65 protected, duly painted with seven tank powder coat painting process, both side opening of size 110 x 100 x 60 cm of MS sheet 3 mm thick powder coated machine pressed front opening in two halves with rubber gasket / bedding , locking arrangement with sliding bolt including aluminium bus bar of size 50 x 10 mm and 80 cm long 3 strips mounted on HT insulators each strip should be munted minimum two insulator and nut bolt panel shall be mounted on angle iron frame and legs made from angle iron of size 50x 50 x 6 mm and legs 70 cm long duly spray painted internally and externally with two coat of synthetic enamel paint over a coat of red oxide primer grouted in PCC 1:2:4 type ‘B’ ( using 20 mm graded stone aggregate) complete incoming / outgoing cable provision alogwith danger notice sign board in red colour complete all as specified and as directed by Engineer-in-Charge.

4

-

-

... More
S&F in replacement LT heavy duty 4 pole on load changeover, 415V, 630 Amps complete with suitable outdoor panel IP 65 protection made out of CRCA mild steel sheet, thickness 2.25 mm single door with lock arrangement and grouting on ground including all necessary electrical connections with accessories complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement LT heavy duty 4 pole on load changeover 415V, 320 Amps complete with suitable outdoor panel IP 65 protection made out of CRCA mild steel sheet, thickness 2.25 mm single door with lock arrangement and grouting on ground including all necessary electrical connections with accessories complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
S&F in replacement LT heavy duty 4 pole on load changeover 415V, 250 Amps complete with suitable outdoor panel IP 65 protection made out of CRCA mild steel sheet, thickness 2.25 mm single door with lock arrangement and grouting on ground including all necessary electrical connections with accessories complete all as specified and as directed by Engineer-in-Charge.

1

-

-

... More
Taking down carefully aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed by Engineer - in - Charge.

90

-

-

... More
M & L for concealed conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLS PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes suitable length and thickness for mounting, switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced by the Engineer in charge.

60

-

-

... More
All as per Srl item No -60 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified and directed by Engineer - in - Charge.

10

-

-

... More
All as per Srl item No -60 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed by Engineer - in - Charge.

10

-

-

... More
All as per Srl item No. 60 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed by Engineer - in - Charge. (Make of cable - Havells/Anchor/L&T)

10

-

-

... More
S & F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed by Engineer - in - Charge.

50

-

-

... More
S & F switch socket combination 3 pin, type 5/6 Amps flush type complete all as specified and directed by Engineer - in - Charge.

5

-

-

... More
S & F Socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer - in - Charge.

10

-

-

... More
S & F ceiling rose surface bakelite three terminals complete all as specified and directed by Engineer - in - Charge.

22

-

-

... More
S & F in replacement of existing light fitting with LED batten with aluminium housing and integrated electronic driver, 20 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor twin core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge. (Make:Havells cat part No: LUMILINEPLUSBS20WLED865SPCSS , Bajaj cat part no.: BCLSBAL 20W CW ,Crompton cat part no. : CCS-100-20-65-HL2-DP-NWH)

20

-

-

... More
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.

5

-

-

... More
S&F LED lamp 9W for angle holder complete all as specified and directed by Engineer - in - Charge.

5

-

-

... More
S & F in replacement Water tight bulk head fitting,comprision of connector galvanised cast iron back plate,weather proof enamelled gallery ,glass well,and including 10 watt LED lamp all as specified and directed by Engineer - in - Charge.

3

-

-

... More
S & F in replacement sheet metal enclosure for double door BD made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked, 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.

4

-

-

... More
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.

24

-

-

... More
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.

4

-

-

... More
M&L in repair exhaust fan of size 400/450 mm including rewinding of burnt motor, replacement of worn out bush and bearings complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
M&L in repair exhaust fan of size 180/225 mm including rewinding of burnt motor, replacement of worn out bush and bearings complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 25 to 50 sqmm as specified and directed.

6

-

-

... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm as specified and directed.

6

-

-

... More
Supply and fix cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ core XLPE, armoured, Al conductor cable of size 120 sqmm as specified and directed.

3

-

-

... More
Supply and fix in replacement aluminium terminal lugs suitable for aluminium XLPE cable of size 35 sqmm X 3.5 core including necessary jointing with MS nuts and bolts of suitable size complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
Supply and fix in replacement aluminium terminal lugs suitable for aluminium XLPE cable of size 50 sqmm X 3.5 core including necessary jointing with MS nuts and bolts of suitable size complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
Supply and fix in replacement aluminium terminal lugs suitable for aluminium XLPE cable of size 70 sqmm X 3.5 core including necessary jointing with MS nuts and bolts of suitable size complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
Supply and fix in replacement aluminium terminal lugs suitable for aluminium XLPE cable of size 95 sqmm X 3.5 core including necessary jointing with MS nuts and bolts of suitable size complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
Supply and fix in replacement aluminium terminal lugs suitable for aluminium XLPE cable of size 120 sqmm X 3.5 core including necessary jointing with MS nuts and bolts of suitable size complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
Disconnecting the electric supply from the existing RMU/VCB/Transformer/HT poles and meggering the HT under ground cable for its IR value and ensuring the servicebility by HT megger,locating the faults by HT fault finder instrument for any distance and reconnect the HT cable. NOTE:- Joint kit and HT UG Cable shall be measured and paid separetly.

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.