Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date3 Oct 2020
Closing Date29 Oct 2020
Tender Amount₹ 30,80,631 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Removing excavated material to a distance n' exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified.

362

-

-

... More
Material and labour for clean dry tibba sand in trenches/ducts for cushoning to cable complete all as specified. (Punned thickness shall be measured & paid)

230

-

-

... More
Supply and laying stone patti 40-50 mm thick, 25-30 cm wide abutting each other for cable protection complete all as specified.

460

-

-

... More
Laying only stone patti received serviceable from item No. 10 here-in-after complete all as specified.

306

-

-

... More
M & L PCC 1:3:6 type C2 using 40 mm graded stone aggregate for foundation of pole. Complete all as directed by Engineer-in-Charge.

2.2

-

-

... More
M & L PCC 1:3:6 type C1 using 20 mm graded stone aggregate for pedestal of poles/coping including form work. Complete all as directed by Engineer-in-Charge.

28

-

-

... More
Labour for removing and Taking out existing underground LT XLPE Cable including cable cover, route indicators from trenches or pole or underground in pipe duct carefully cleaning of the same for relaying incase of serviceable cable complete all as specified and directed.

-

-

-

... More
185 Sqmm 3.5 core

300

-

-

... More
150 Sqmm 3.5 core

300

-

-

... More
120 Sqmm 3.5 core

300

-

-

... More
95 Sqmm 3.5 core

250

-

-

... More
70 Sqmm 3.5 core

300

-

-

... More
50 Sqmm 3.5 core

400

-

-

... More
25 Sqmm 3.5 core / 4 core

500

-

-

... More
10/16 Sqmm 2 core

800

-

-

... More
Relaying, Jointing and testing only under groud armoured cable LT XLPE insulated cable 1100 Volts PVC bedded aluminium conductor cable received from Item No. 10 here-in- before complete all as directed by Engr-in-Charge.

-

-

-

... More
185 Sqmm 3.5 core

200

-

-

... More
150 Sqmm 3.5 core

200

-

-

... More
120 Sqmm 3.5 core

200

-

-

... More
95 Sqmm 3.5 core

100

-

-

... More
70 Sqmm 3.5 core

100

-

-

... More
50 Sqmm 3.5 core

100

-

-

... More
25 Sqmm 3.5 core / 4 core

100

-

-

... More
10/16 Sqmm 2 core

100

-

-

... More
Supply & Laying, Jointing and testing underground armoured cable LT XLPE insulated cable 1100 Volts PVC bedded galvanised steel strip or wire armoured electric LT UG cable heavy duty with multi stranded aluminium conductor laid in trenches / walls/ ducts passing through pipe cable of following size complete all as specified:-

-

-

-

... More
185 Sqmm 3.5 core

100

-

-

... More
150 Sqmm 3.5 core

100

-

-

... More
120 Sqmm 3.5 core

100

-

-

... More
95 Sqmm 3.5 core

150

-

-

... More
70 Sqmm 3.5 core

200

-

-

... More
50 Sqmm 3.5 core

300

-

-

... More
25 Sqmm 3.5 core / 4 core

400

-

-

... More
16 Sqmm 2 core

300

-

-

... More
10 Sqmm 2 core

400

-

-

... More
M & L in replacement pre-stressed concrete pole 9 Mtrs long 102 mm X 172 mm at top and 102 X 279 mm at bottom class 10, including painting of pole in alternate colour yellow and black upto a height specified as per IE rules and marking of pole number by using stencil complete all as directed by Engineer-in-Charge. Note : (a) Excavation and PCC will be measured and paid separately. (b) Font and letter size for marking of pole number will be as per direction of Engr-in-Charge. (c) Rate for dismanteling & removal of old pole from AF stn deemed to be included in quoted rate.

20

-

-

... More
S&F in repairs galvanised steel tube "light grade" with fittings for protection of cable for the following sizes complete all as directed by Engineer-in-Charge.

-

-

-

... More
100 mm bore

30

-

-

... More
80 mm bore

30

-

-

... More
50 mm bore

30

-

-

... More
40 mm bore

50

-

-

... More
Taking Down old unserviceable LT cable route indicator and refixing the serviceable route indicator in position as directed including tracing out route of LT underground cable network from distribution transformer to main distribution box of building by using all necessary measuring equipment. Mapping the same on hardcopy A1 size (33.1 inch x 23.4 inch) paper (set of three) and 02 x soft copy in CD duly marking exact detail of all roads/buildings/drains (with alloted numbers/names) exist along the circuit or nearby. Note : (a) Details of electrical equipment i.e. transformer/LT panel/feeder piller/main DB etc. and LT cables their capacity, size has to be checked and marked on diagram. (b) cost for T&P i.e. vehicle, ladder, electrical tools /kits etc, safety equipments, measuring/tracing equipment deemed to be included in quoted rates. (c) The LT cable route indicator required to be replace shall be paid seperately as supply only in item No 33 of this schedule.

100

-

-

... More
Labour only for attending the complaints/job for interruption/defect in continuity of electric supply in electrical switchgears, LT panels, feeder pillers, busbars, main switches etc for the following items complete all as specified and directed :-

-

-

-

... More
ACB of any capacity

30

-

-

... More
MCCB of any capacity

500

-

-

... More
MCB of any capacity

400

-

-

... More
Panel Meter of any type & capacity

100

-

-

... More
Rewiring of LT panel, dressing/insulating exposed busbars & wiring, tightning of all nut bolts of bus bars connecting point etc except incoming and outgoing LT cable

100

-

-

... More
Internal cleaning for dust/spider web

300

-

-

... More
Dressing and insulating of exposed parts of incoming/outgoing LT cable end termination joint 3.5/4 core of any capacity/type including reconnecting the same to circuit and marking of incoming/outgoing feeder detail on cable by using appropriate stencil and colour.

200

-

-

... More
Welding/brazing for door/hinges/lock etc

50

-

-

... More
Note:- (a) The contractor has to arrange minimum one well experienced electrician & one helper on all working hours attend the repair mentioned against item No. 16.00 to 16.08 throughout the contract period. The rates of services required as mentioned above is deemed to be included in quoted rates against the item mentioned. The assigned job should be attended within two hours after receipt. If the contractor failed to attend the job within given time frame penalty at Rs 1000/- per hour will be imposed for each additional hour. Work at site will be completed as per direction of Engr-in-charge.(b) Minor item such as lugs/spreader (copper/aluminium), electrician insulation tape, nut bolts, indicator lamp for R Y B phase, electrical wire of single core from size 0.5 sqmm to 10 sqmm upto a length of 01 metre for each job), mounting arrangement of MCCCBs/MCBs/Panel meters and other minor misc items or iron/hardware work in case of un even fittings deemed to be included in quoted rates. in case of any dispute for the same garrison Engineer will decide the characteristics of minor item and his/her decision will be binding. (c) Contractor will arrange necessary tools and plants i.e. ladder, vehicle, electrician tool kit, measuring instruments etc., safety equipment, first aid box with all essential medicins, hygenic equipment of COVID-19.(d) The items required for replacement for attending the work listed under srl item No. 16.01 to 16.08 shall be measured and paid separetly against item srl No. 17.01 to 21.00 as supplied only.(e) Contractor will update complete details of repair / Job completed or under progress on daily basis. Details of repair / Job to be done will be provide by JE (E/M) throughout the contract period. Contractor will provide all necessary stationary i.e. job slip and job register necessary writting material and other required items pertains to his job. Contractor is responsible to update all the repairs/jobs completed or under progress and produce the same daily on demand to JE E/M. Rates for the same deemed to be included in quoted rates.

-

-

-

... More
Supply only moulded case circuit breaker, 415 Volts, 4 pole, lcs=100%lcu, adjustable overload setting 0.8-1.0 x In and short circuit setting 6-10 x In with thermal magnetic settings including spreader terminal and connecting items confirming to IS/IEC 60947-2 having following capacities :-

-

-

-

... More
MCCB 630 Amps 36 KA make- cat part CM94106OOT1OG in L&T or equivalent in Legrand, Siemens, C&S, Havells

2

-

-

... More
MCCB 400 Amps 36 KA make- cat part CM94106OOS1OG in L&T or equivalent in Legrand, Siemens, C&S, Havells

8

-

-

... More
MCCB 250 Amps 36 KA make- cat part CM98403OOQOOG in L&T or equivalent in Legrand, Siemens, C&S, Havells

6

-

-

... More
MCCB 200 Amps 36 KA make- cat part CM92109OOP1OG in L&T or equivalent in Legrand, Siemens, C&S, Havells

12

-

-

... More
MCCB 160 Amps 36 KA make- cat part CM92109OON1OG in L&T or equivalent in Legrand, Siemens, C&S, Havells

10

-

-

... More
MCCB 100 Amps 36 KA make- cat part CM92108OOL1OG in L&T or equivalent in Legrand, Siemens, C&S, Havells

15

-

-

... More
Supply only Air Circuit breaker, 415 Volts, 3 pole, manual draw out type lcu=lcs=lcw for 1 sec including spreader terminal/terminal adapter and connecting items Confirming to IS/IES 60947-2 of 800 Amp current rating. Make : L&T/Legrand/ABB/Siemens/C&S/Crompton. Note:- Size and fitting shall be as per existing size and fitting.

2

-

-

... More
Supply only Miniature circuit breaker, 240 Volts, C curve type with breaking capacity 10 KA including Confirming to IS/IEC 60898-1 having following capacities:-

-

-

-

... More
MCB 6 A SP

20

-

-

... More
MCB 16 A SP

18

-

-

... More
MCB 25 A SP

20

-

-

... More
MCB 6 A DP

20

-

-

... More
MCB 16 A DP

14

-

-

... More
MCB 25 A DP

15

-

-

... More
MCB 40 A TP

8

-

-

... More
MCB 63 A TP

10

-

-

... More
MCB 40 A FP

8

-

-

... More
MCB 63 A FP

10

-

-

... More
Supply only three phase LED ampere meter accuracy class 0.5, input voltage 50-500 V AC (P-P), aux supply 80-300 V AC CT secondary site selectable 1A/5 A, Flush mounting 96x96 mm, inbuilt selector switch for 3 phase meters, with CTs for three phases of rated capacity suitable as per site requirement (CT site progrmmable) complete all as specified and directed by Engr-in-Charge. Make:- L&T, Schneider, siemens

10

-

-

... More
Supply only three phase LED volt meter accuracy class 0.5, input voltage 50-500 V AC (P-P), aux supply 80-300 V AC , Flush mounting 96x96 mm, inbuilt selector switch for 3 phase meters, with PTs for three phases of rated capacity suitable as per site requirement (PT site progrmmable) complete all as specified and directed by Engr-in-Charge. Make:- L&T, Schneider, siemens

10

-

-

... More
S & F in repairs end termination cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing of following sizes:-

-

-

-

... More
25 to 50 sqmm 3.5 core

10

-

-

... More
70 to 120 sqmm 3.5 core

10

-

-

... More
150 to 185 sqmm 3.5 core

5

-

-

... More
240 to 300 sqmm 3.5 core

3

-

-

... More
S & F in repairs Straight through cable jointing kit, heat shrinkable for 1.1 KV grade XLPE cable complete with jointing material and accessories and testing after jointing of following sizes:-

-

-

-

... More
25 to 50 sqmm 3.5 core

10

-

-

... More
70 to 120 sqmm 3.5 core

10

-

-

... More
150 to 185 sqmm 3.5 core

5

-

-

... More
240 to 300 sqmm 3.5 core

3

-

-

... More
M&L for drilling hole under road for laying of U/G cable through pipe of suitable size complete all as specified and directed at site.

50

-

-

... More
Supply install and testing out door wheather proof bus bar chamber of size 120 cm x 40 cm x 40 cm made out of 18 SWG MS sheet having one side openable hinged door shutter with looking arangement mounted on 40x40x6mm anlge iron frame with legs welded and 04 nos copper bus bar of 300 Amp rating including of one MCCB TPN 200 Amp 16 KA for controlling Electric supply complete erected on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer red oxide including making cable connection with necessary gland , lugs/thimbles all as specified. NOTE: Cost of dismantling/ taking down old unserviceable bus bar chamber shall be included in the quotedd rate of this item.

2

-

-

... More
Supply install and testing out door wheather proof bus bar chamber of size 120 cm x 40 cm x 40 cm made out of 18 SWG MS sheet having one side openable hinged door shutter with looking arangement mounted on 40x40x6mm anlge iron frame with legs welded and 04 Nos copper bus bar of 200 Amp rating including of one MCCB TPN 100 Amp 16 KA for controlling Electric supply complete erected on ground with necessary PCC 1:3:6 type C2 foundation complete bus bar chamber painted with two coats of approved enamel paints over one coat of primer red oxide including making cable connection with necessary gland , lugs/thimbles all as specified. NOTE: Cost of dismantling/ taking down old unserviceable bus bar chamber shall be included in the quotedd rate of this item.

2

-

-

... More
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 50mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. Note:- (a) Following items deemed to be included in quoted rates:- (i) Earth Electrode (ii) Main earth lead from earth electrode to test point and further to equipment to be earthed upto 7.5Mtr (iii) M&L for connecting earth electrode and earth lead as specified (iv) Adequate qty of charcol, dust and common salt as per direction (v) All labour involved incl testing of earth network (vi) Excavation and earth work or drilling hole for electrode (G) PCC pit and CI cover (vii) Funnel with watering pipe, wiremesh and copper lugs etc as specified (viii) GI protection pipe of size as specified for protection of earth lead from mechanical injury or tempring (b) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost (c) Cost of dismantling of old earthing and making the site in serviceable condition shall be included in the quoted rate.

12

-

-

... More
M&L earthing complete as per electrical plate No. 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less then 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 25mm x 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole / test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested complete. Note:- (a) Following items deemed to be included in quoted rates:- (i) Earth Electrode (ii) Main earth lead from earth electrode to test point and further to equipment to be earthed upto 7.5Mtr (iii) M&L for connecting earth electrode annd earth lead as specified (iv) Adequate qty of charcol, dust and common salt as per direction (v) All labour involved incl testing of earth network (vi) Excavation and earth work or drilling hole for electrode (G) PCC pit and CI cover (vii) Funnel with watering pipe, wiremesh and copper lugs etc as specified (viii) GI protection pipe of size as specified fior protection of earth lead from mechanical injury or tempring (b) On testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost (c) Cost of dismantling of old earthing and making the site in serviceable condition shall be included in the quoted rate.

13

-

-

... More
S & F in repairs for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in counduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required to 32x6mm galvanised iron strip galvanised iron or steel wire

30

-

-

... More
S & F in repairs for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in counduit /pipe or fixed to poles or any other indicated situation for loop earthing etc. as required to 25x4mm galvanised iron strip galvanised iron or steel wire

30

-

-

... More
Labour and machine required for locating fault in U/G LT cable 1100 volts by using fault detector machine including transportation and by carrying out high pressure test complete all as specified and directed by Engr-in-Charge. Note: Required excavation and returning filling work deemed to be included in quoted rates.

10

-

-

... More
Labour for pruning/trimming the tree branches 3Mtr adjacent to the LT OH lines/street light feeder on both sides of conductor taking out the same to dump yard/place as decide by Engr-in-Charge. Note: (a) The work shall be carriedout as per availability of site as reqd by Engr-in-Charge. The intimation to execute the work shall be given to contractor by Engr-in-Charge on one day prior notice. Proper shut down shall be provided in the area of work, the contractor shall take proper precaution while carrying out work considering the HT< lines falling in the area of work. (b) An electrician will always be present on site with working labour and all necessary tools plants i.e. lader, vehicle etc, safety equipment, first aid box with all essential medicines, hygenic equipment of Covid-19 (Permission to work will be provide after written confirmation of the same) Rates for the same deemed to be included in quoted rates.

160

-

-

... More
Supply and fixing in repairs LT cable route indicator cast iron of suitable size mounted on 40 x 40 x 3 mm angle iron with height of 1.5 metre along with LT cable trench including planting in ground with PCC complete all as specified and directed by Engr-in-Charge.

100

-

-

... More
Supply and fixing in replacement of PVC insulated and over all PVC sheathed, stranded copper conductor wire 1.5 sqmm x 3 core ISI marked complete all as specified and directed .

100

-

-

... More
M&L for disconnecting jumpers of from OH LT line and remove carbon and replace the damaged jumpers refixing, connecting and testing the same complete all as required at site.

30

-

-

... More
S&F of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections twin core cable flat stranded consuctor of following sizes including taking down old Unserviceable cable:-

-

-

-

... More
2.5 sqmm 2 core

100

-

-

... More
4 sqmm 2 core

200

-

-

... More
10 sqmm 2 core

300

-

-

... More
M&L for test point terminal block made of gun metal or phosphorus bronze size 75mmx75mmx25mm drilled and srewed including 3 Nos 8mm dia 25mm long hex. Head srew complete all as specified and directed.

50

-

-

... More
Surface dressing /cleaning of surrounding area of two pole/four pole/Sub Stn structure including removing of tree branches, small trees plants bushes etc complete all as specified and directed.

2750

-

-

... More
M&L for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed.

100

-

-

... More
Painting of LT panel with one coat of synthetic enamel paint of approved colour, writing letters on LT panel (by using appropriate colour, size /font stencil) for all incoming and outgoing feeder complete all as specified and directed by Engr-in-Charge

100

-

-

... More
Writing letter on LT panel (by using appropriate colour,size/font stencil0 for all incoming and outgoing feeder complete all as specified and directed by Engr-in-charge

200

-

-

... More
S&F of LED glow sign board with 3 dimension letters mounted on aluminium composite panel of size 10 feet x 3 feet complete all as specified and directed by Engr-in-Charge. Note : (i) Font, Size, colour and number of letters will be as approved by Garrison Engineer. (ii) Rates for mounting arrangement with complete accessories i.e. M.S. clamps, bolts, nuts and other required material deemed to be included in quoted rates.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.