Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Civil And Construction
Building Construction
Eprocure
Opening Date16 Nov 2024
Closing Date18 Dec 2024
Tender Amount₹ 48,08,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only liquid water proofing compound ISI Mark complete. Make: Dr. Fixit or Equivalent.

18

-

-

... More
M&L for cleaning of all loose dirt and dust from roof and priming the surface with one coat of cold applied bituminous primer @ 0.40 litre/sqm and provide a layer of APP based polymeric membrane minimum weighing 3 Kg/sqm and minimum 3mm thick, reinforced with polyester non woven fabric (weighing not less than 150 gms/sqm) laid on primed surface complete all as described in Para 11.44.5 of SSR Part-I, complete all as specified and as directed. Note : The net area of water proofing treatment shall be measured without any extra allowance for laps.

675

-

-

... More
M&L Lime concrete terracing as in roof complete all as specified and as directed by Engineer-in-Charge.NOTE:- For lime concrete, mudia kankar (source : NAL) and Kolayat coarse sand in lieu of brick aggregates and Surkhi respectively as specified in MES schedule Part-I shall be used.

67

-

-

... More
M & L for 40 mm thick burnt clay brick tiles bedded on cement mortar and joints grouted flush in cement and sand mortar (1:3) mixed with integral water proofing compound IS 2645 : 2003 @ 3% by wt of cement as Complete all as specified and as directed..

575

-

-

... More
Ditto complete all as per Item No 7 above but except tiles complete all as specified.

100

-

-

... More
Demolition of cement concrete (reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified.

1

-

-

... More
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified.

2

-

-

... More
M&L RCC type B1 1:2:4 ( 20mm graded stone aggregate) in Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like in Chajja repairs all as specified and directed.

2

-

-

... More
M & L for Mild steel TMT bars 10mm dia and over,cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality conforming to complete as specified.

300

-

-

... More
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressum-mers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams complete all as specified and as directed by engineer-in-charge.

20

-

-

... More
Dismantling floor, hearth or wall tiling any type including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the primises complete all as specified and as directed by engineer-in-charge.

850

-

-

... More
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed by engineer-in-charge.

8

-

-

... More
M&L for non skid coloured ceramic tiles of 7 mm to 8 mm thick (square/rectangular) polished, area of each tile exc 0.18 not exc 0.38 sqm in floors, over and including 15mm thick screed in CM (1:4) set and jointed in neat cement slurry and pointed with white or coloured cement to match complete all as specified and as directed by engineer-in-charge.

600

-

-

... More
Ditto all as above item no 16 but as in skirting/dado over and incl 10 mm thick rendering in CM 1:4 all as specified and as directed.

50

-

-

... More
M & L for coloured Non skid ceramic tiles 7 to 8 mm thick (squar/ rectangular) area of each tiles exc 0.11 Sqm but n.exc 0.18 Sqm in floor etc. set and jointed in neat cement slurry and pointed in coloured cement to match the floor laid over 15mm thick screed bed in cement mortar 1:6 complete all as specified.

100

-

-

... More
M & L for coloured Glazed ceramic tiles 450mm x 350mm x 7mm OR 300mm x 450mm x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match the floor as on vertical surfaces laid over 10 mm thick cement plaster in 1:4 complete all as specified.

100

-

-

... More
M & L for 25 mm thick Cement concrete 1:2:4 type B0 using 12.5mm graded stone aggregate in floors to receive finished even and smooth using extra cement complete all as specified.

200

-

-

... More
M&L for 18 to 20 mm thick Granite (of any type) machine cut slab of approved shade (table rubbed and mirror polished) with true & uniform joints as in steps, jambs, pillars, window cills, cooking platforms, wash basin top & like and pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed (bedding layer) in CM 1:4 with cement slurry @ 3 Kg/Sqm complete all as specified & as directed.

2

-

-

... More
M&L 18-20 mm thick single piece machine cut kota stone slab as in flooring/steps laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15 mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.

20

-

-

... More
M&L 18-20 mm thick single piece machine cut kota stone slab on vertical surface and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15 mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.

5

-

-

... More
Taking down shutter of any description exc.1 Sqm but not exc.2 Sqm each and refixing in the same opening after necessary easing, repairs, adjustment etc. complete all as specified.

3

-

-

... More
Taking down chowkhats or frames not exc.1.50 Sqm each but with shutter (with out taking of shutter from the frame ) and making good the surface of walls as per existing with cement mortar complete.

80

-

-

... More
Taking down chowkhats or frames exc. 1.50 Sqm each but n.exc 4 Sqm with shutter (with out taking of shutter from the frame ) and making good the surface of walls as per existing with cement mortar complete all as specified.

10

-

-

... More
Taking down shutter of any description exc. 1sqm but not exc.2 sqm each complete all as specified.

2

-

-

... More
S & F for pressed steel frames of size 125 x 60 mm with one or more rebates including necessary fixing lugs hinges, locks trike plate etc (thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6 complete all as specified.

10

-

-

... More
S & F for pressed steel frames of size 105 x 60 mm with one or more rebates including necessary fixing lugs hinges, locks strike plate etc (thickness of sheet shall be 1.25mm) and making good the plaster of wall in CM 1:6 complete all specified.

60

-

-

... More
Cutting holes in brick walls in cement mortar exc half brick but not exc one brick for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required all as specified.

120

-

-

... More
S & F for bands, straps, supports or stays for rain water, ventilating pipes, including bolts, if required, hooks and pintal hinges, large hasp and stapals, chains hand made sliding bolts, clamps, hold fast,wall ties, hooks for hanging fans, plain angle cleats for securing purlins to woods trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articals conforming to Fe 290 Gde-E-165 complete all as specified.

25

-

-

... More
M & L for PCC 1:3:6 type C-1 (using 20mm Graded Stone Aggregate) as in fixing Holdfast, Plinth courses, bed plates, string courses, coping, filling of chowkhats etc., complete all as specified and as directed by Engr-in-Charge.

0.5

-

-

... More
S&F Second class hard wood plain, framed, panelled shutters 30mm thick, (any number of panels) with panels of timber flat on both sides (feather edged) or of veneered partcile board medium density wood particle board with commercial faces venners supplied and fixed to chowkats.

28

-

-

... More
S&F Second class hard wood, glazed and skelleton shutters 30mm thick, open rebated and prepared to receive glass, gauze, etc without sash bar, edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing gauze etc, size of members as directed supplied and fitted to chowkats

28

-

-

... More
S&F Solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M.S. square tube suppling & fixing in opening all as specified and as directed.

70

-

-

... More
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails, MS frame shall be covered with head moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rain & bottom rail paneling of plain gap insert for top rail & bottom rail paneling of plain color PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement all as specified.

24

-

-

... More
M & L stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified.

80

-

-

... More
M & L stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples fixed in repairs complete all as specified.

10

-

-

... More
S & F for 100 mm long powder coated Aluminium Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified.

42

-

-

... More
S & F for 150 mm long, aluminium, powder coated, barrel tower bolts of extruded section complete all as specified.

28

-

-

... More
S & F for 100 mm size aluminium powder coated handles, cast type, anodised complete all as specified.

28

-

-

... More
S & F for 100mm size butt hinges, medium weight cold rolled mild steel complete all as specified.

39

-

-

... More
S&F in repairs stainless steel wall drope hanger 12 mm dia and 10 ball pin hook wall drope hanger hook rail bar for cloths fixed to wall with three rawl plugs and chromium plated brass screws complete all as specified & as directed.

50

-

-

... More
S&F in repairs stainless steel Peg Set of Six of standard size (not less than 300mm long) fixed to wall with two rawl plugs and chromium plated brass screws complete all as specified & as directed. Make :- Cat Part No. BEA-30 of Prayag or equivalent in makes mentioned in PS (Appdix)

10

-

-

... More
S&F in repair mild steel 300mm ordinnary rat tail rod pattern springs including roller and roller plate complete all as specified and as directed by engineer-in-charge.

13

-

-

... More
S & F for 300mm long aluminum alloy anodized sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy complete all as specified.

13

-

-

... More
Preparation of Old wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed by engineer-in-charge.

20

-

-

... More
Preparation of New or previously untreated wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of Pink primer complete all as specified and as directed by engineer-in-charge.

100

-

-

... More
M & L preparation of old steel surfaces of any description, over 10 cm in width or girth, and applying one coat of synthetic enamel paint incl preparation all as specified.

20

-

-

... More
M & L preparation of new steel surfaces of any description, over 10 cm in width or girth, and applying one coat of synthetic enamel paint incl preparation all as specified.

300

-

-

... More
S & F for 3 mm thick sheet glass, ordinary quality and glazing with oil putty in squares n. exc 0.5 Sqm in each pane complete all as specified.

60

-

-

... More
S & F for 4 mm thick pin headed sheet glass, ordinary quality and glazing with oil putty in squares n. exc 0.5 Sqm in each pane complete all as specified.

10

-

-

... More
Demolition of Brickwork , built in cement mortar including all quoins, arches, pillars complete all as specified and as directed by engineer-in-charge.

3

-

-

... More
M&L for brick work with old size Fly Ash bricks, straight or curved on plan exc 6.00 metre mean radius, built in cement mortar 1:6 complete all as specified and as directed.

2

-

-

... More
M&L for brick work with old size fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in cement mortar 1:4 complete all as specified and as directed.

10

-

-

... More
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to complete.

200

-

-

... More
S & F GI tubing 15mm dia medium grade with all fittings and fixed to wall, floor and ceiling etc complete all as specified.

180

-

-

... More
Fixing only of old steel GI tubing, 15mm bore and connections in new or old position (walls, ceiling, floors etc) complete

20

-

-

... More
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to complete.

50

-

-

... More
S & F for GI tubing 20mm dia medium grade with all fittings and fixed to wall, floor and ceiling etc complete all as specified.

30

-

-

... More
Fixing only of old steel GI tubing, 20mm bore and connections in new or old position (walls, ceiling, floors etc) complete all as specified.

20

-

-

... More
S&F in replacement Bib tap, cast copper alloy Fancy type, CP, long neck with crutch or butterfly handle, screwed down, suitable for 15mm nominal bore iron pipe screwed for iron or brass ferrule and fixed.

16

-

-

... More
S&F in repairs 15mm bore Angle stop valve, brass, chromium plated, fancy type, screwed down, high pressure with capstan head, screwed both ends for iron pipe or for union, including CP brass wall flange, complete all as specified & as directed.

24

-

-

... More
S&F in repairs 15mm bore two way Angle stop valve, brass, chromium plated, fancy type, screwed down, high pressure with capstan head, screwed both ends for iron pipe or for union, including CP brass wall flange, complete all as specified & as directed.

6

-

-

... More
S&F in repairs Shower rose, round type, brass, chromium plated,all as specfified and directed

5

-

-

... More
S&F in repairs Soap dish, vitreous China white/CP, approximate size 160x 160x90mm all as directed by Engineer in Charge.

5

-

-

... More
S&F in repairs tubular towel rail brass chromium plated , 20mm dia, 60cm long between flanges in repairs.

10

-

-

... More
S & F as in repair, gun-metal, of 20 mm globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified.

4

-

-

... More
S & F 20 mm ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic bal screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/40mm- 690 gms/50mm-1240 gms) all as specified.

5

-

-

... More
S & F as in repair, PVC flexible connections 450mm long 15mm dia with brass flange nuts & washers complete. Make: Prayag/Polytuf or equivalent as approved by Engr-in-Charge.

24

-

-

... More
S & F as in repair, 100 mm dia CI floor trap with CP grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified.

10

-

-

... More
M & L for 75mm thick PCC 1:3:6 C2 using 40 mm graded stone aggregate as in plinth protection laid in panels and finished even and smooth without using extra cement complete all as specied and directed.

100

-

-

... More
Dismantling of cast iron drain pipe of 100/75mm bore, jointed in CM and taking out of trenches or floors, if required, complete all as specified & as directed. Note :- Excavation & earthwork shall be measured and paid separately.

80

-

-

... More
Supply and fixing 100 mm bore cast iron, soil, waste & vent pipes in any length with or without ears, spun pipes, ISI marked, fixed with cement joints, laid in trenches or floors, complete all as specified and as directed.

50

-

-

... More
Ditto all as per above item no 74 but except pipes

10

-

-

... More
Supply and fixing 75 mm bore cast iron, soil, waste & vent pipes in any length with or without ears, spun pipes, ISI marked, fixed with cement joints, laid in trenches or floors, complete all as specified and as directed.

20

-

-

... More
Supply and fixing 75 mm bore cast iron, soil, waste & vent pipes in any length with or without ears, spun pipes, ISI marked, fixed with cement joints, fixed to walls, complete all as specified and as directed.

15

-

-

... More
Ditto all as per above item no 77 but except pipes

5

-

-

... More
Extra over cast iron pipe and fittings if lead joint is provided in lieu of cement joint for 75 mm pipe complete all as specified and as directed.

10

-

-

... More
Extra over cast iron pipe and fittings if lead joint is provided in lieu of cement joint for 100 mm pipe complete all as specified and as directed.

10

-

-

... More
S & F in repairs 100 mm dia branch piece single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door all as specified.

10

-

-

... More
S & F in repairs 75 dia branch piece single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access door all as specified.

10

-

-

... More
S&F in repairs 75 mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified.

10

-

-

... More
S&F in repairs 75 mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) without oval access door complete all as specified.

5

-

-

... More
S & F in repairs 100 mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified.

5

-

-

... More
S & F in repairs 100 mm bore CI bends (any radius), diminishing pieces or tapers (larger bore measured) without oval access door complete all as specified.

5

-

-

... More
S & F in repairs 100 mm bore CI tee (any radius), diminishing pieces or tapers (larger bore measured) with oval access door complete all as specified.

5

-

-

... More
S & F in repairs, 100 mm CI bends (any radius) with duck's foot or heel rest complete all as specified.

5

-

-

... More
S & F as in repair, 100 mm cast iron sanitary connection socket in fit WC out-let complete all as specified.

5

-

-

... More
S & F for cast iron vent cowls 100 mm dia complete all as specified.

10

-

-

... More
S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof for 50 mm bore all as specified.

12

-

-

... More
S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof 75 mm bore all as specified.

12

-

-

... More
S & F stack clamps out of 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof 100 mm bore all as specified.

12

-

-

... More
S&F in repair curtain rod 20 mm dia, mild steel, chromium plated, fancy type with fixing brackets and knobs at both ends as per site requirement complete all as directed by Engineer-in-Charge. Note:- The cost of brackets and knobs is deemed to be included in the quoted rate. Nothing extra shall be paid on this account.

150

-

-

... More
S&F in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of cast iron brackets embedded in PCC 1:3:6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed, (excluding tap, waste chain & plug), complete all as specified & as directed.

2

-

-

... More
S &F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mmthick AC building board or commercial plywood and fixed to wooden plugs withchromium plated brass screws and cup washers complete all as specified and as directed.

6

-

-

... More
S&F in repairs Vitreous China wash down water closet pan (Pedestal pattern) white complete incl seat and cover, flush pipe incl all joints complete all as specified and as directed.

2

-

-

... More
S&F in repairs vitreous china squatting pan, ‘Orissa’ pattern, white, size 580x440mm with integral foot rests, ‘P’ or ‘S’ trap, including connection to trap and flushing pipe, antisyphonage pipe etc, making good to floor in CM 1:3, complete all as specified and as directed.

7

-

-

... More
S & F PVC valve less, syphonic action type, fluhsing cistern, 10 ltrs capacity, low level, white, with inlet, ball valve, float and handle including 32mm bore PVC flushing pipe, brackets and fixed in repairs including taking down existing flushing cistern of any description complete all as specified.

9

-

-

... More
Taking down cement plaster/terrazo finish on brick or stone walll etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.

900

-

-

... More
M & L for 10mm thick Rendering in cement mortar 1: 6 on fair faces of brick work or concrete surfaces, finished even & smooth without using extra cement complete all as specied and directed.

300

-

-

... More
M & L for 15mm thick Rendering in cement mortar 1: 4 on fair faces of brick work or concrete surfaces,incl water proofing liquid finished even & smooth without using extra cement complete all as specied and directed.

500

-

-

... More
M & L for 5 mm thick Rendering in cement mortar 1:3 on concrete surfaces in ceiling, finished even & smooth without using extra cement complete all as specied and directed.

100

-

-

... More
M & L for rendering 10 mm thick in cm 1:4 as setting coat and 5 mm thick in cm (1:4) as finishing coat as in chajja with WPC. Note: - WPC should be measured and paid separately.

50

-

-

... More
M & L for preparing new plastered or surfaces of walls and applying two coats of distemper oil emulsion, white or tinted over & incl a coat of primer over & incl 3 mm thick Birla white putty complete all as specified.

300

-

-

... More
Preparation of newly plastered surfaces of wall including cornices, pillasters etc and applying two coats of cement based paint, white or tinted over a coat of alkali resistant priming paint complete all as specified.

500

-

-

... More
M & L for preparing new plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified.

100

-

-

... More
M & L for preparation of old surfaces by complete removal of existing treatment of walls incl paillars etc. by mechanical equipment like electric wall sander and applying two coats of oil bound distemper using rollers over a coat of primer incl two coats/layer of wall care putty complete all as specified and as directed by Engr-in-Charge.

800

-

-

... More
M&L for complete removal of existing treatment of wall including cornices, pilasters etc by scraping down and applying two coats of cement based paint, white or tinted complete all as specified and as directed by Engineer-in-Charge

300

-

-

... More
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of Acrylic emulsion paint (Exterior grade) of approved shade/tint over a coat of suitable priming paint on walls complete all as specified and as directed.

80

-

-

... More
M & L for framed work such as grills, gratings etc. with ends of bars shouldered and or rebated or forged into spikes, framed guard bars etc confirming to Fe-290-Gde-E-165 incl dismantling the same complete all as specified.

180

-

-

... More
Removing building materals etc., (other than spoil payable under items 99 to 102 in Section 3-Earthwork) to a distance 5 km or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination all as specified.

75

-

-

... More
M&L for anti termite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified & as directed.

200

-

-

... More
M&L for anti termite treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors complete all as specified & as directed.

115

-

-

... More
Cutting chases, pining in, making good to facings where required and pointing in cement mortar 1:3, for concealed water tubing etc and maing good, cutting exc 10cm and not exc 20 cm girth complete all as specified.

148

-

-

... More
S&F salt glazed stone ware drain pipes of 150mm bore, Class ‘SP 2’, ISI marked, laid to slope in trenches, jointed in CM (1:1) and tested complete all as specified & as directed.

20

-

-

... More
M&L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate in bedding to SGSW drain pipes, including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe complete all as specified and as directed.

16

-

-

... More
Forming jambs, etc. in CM 1:4, to openings (to foregoing item), with stone supplied by MES including cutting, toothings and properly bonding into old work, including facing and pointing (if necessary) to match existing work, complete.

60

-

-

... More
S&F factory fabricated pressed steel frame/box windows, ventilators with glazed and fly proof shutters provided to size and dimension as specified & shown on drawing No BTD-888R Sheet No 1/5 to 5/5 & BTD-889 Sheet No 1/4 to 4/4 or as directed by GE with & including MS grills, MS fillets, pintol hinges, tower bolts, MS handles, peg stays, MS lugs, locking arrangement, dash through bolt where required, etc complete all as specified and as directed. Notes: -(i) PCC for filling in frames, glass, wire gauge and painting shall be measured & paid in separately under respective items. Provision of all other items as shown & specified on drawings shall deemed to be include in provision of cutting holes of suitable depth in walls for inserting lugs etc and making good dismantled portion in PCC 1:2:4 type B-0 using 12.5 mm graded stone crushed stone aggregate and CM (1:3).

58

-

-

... More
Disconnecting & taking down the existing unserviceable water tank and Supply and fixing 1000 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top), ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.

4

-

-

... More
Disconnecting & taking down the existing unserviceable water tank and Supply and fixing 500 Litre capacity Rotational moulded polyethylene water storage tanks double layered (cylindrical vertical with closed top), ISI marked, hoisted & fixed in position & making necessary arrangements for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.

1

-

-

... More
S&F in repairs 15 mm bore concealed type angle valve,chromium plated, high pressure with capstan head, fixed to iron pipe or for union, including CP brass wall flange, complete all as specified & as directed.

6

-

-

... More
M&L for 75mm thick cement concrete 1:4:8 type D2 using 40mm graded stone aggregate in sub base in floors and paving ,laid in panels and finished even & fair complete all as specified and as directed by Engineer-in-Charge.

30

-

-

... More
M&L Chequerred cement concrete tiles 30 cm x 30 cm x 25mm/20cmX20cmX25mm thick rubber finish glazed top thick with grey cement & pigmet machine pressed, set, jointed and pointed in neat cement slurry in floors over and including 20 mm thick screed bed in cement and sand mortar 1:6 complete all as specified and as directed by Engineer-in-Charge.

30

-

-

... More
M&L for 25 mm thick sand filling under floors, cushning under interlocking tiles or in foundations incl watering and consolidations complete all as specified and as directed by Engineer-in-Charge.

3

-

-

... More
M&L 60 mm thick factory made coloured mixed with pigment precast concrete interlocking paver block of grade M-35 confirming to IS 15658-2006 manufactured by vibratory process laid over sand cushioning complete all as specified & directed.

30

-

-

... More
Repairing visible cracks and voids or any porous substrate are to be filled with Epoxy injection by one component pump name MASTERINJECT 1315(BASF) data sheet.

25

-

-

... More
Providing and applying jacketing around columns with providing and laying micro concrete band name MASTEREMACO S466(BASF) including shuttering drilling holes and fixing shear anchor as per specification complete Note- reinforcement shall be measurement and paid separately. ( Rate to be deemed included jacketing formwork and micro concrete.

2

-

-

... More
Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips all as specified and directed.

145

-

-

... More
Ditto as above item ser no 129 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders all as specified and directed.

34

-

-

... More
Taking down/out loose & damaged concrete/cement plaster from soffits of ceilings, floor/roof slabs, vertical surfaces of columns, beams etc., including exposing and removing rust fron the reinforcement by rubbing with wire brush and removal of debris to a distance n. exc. 100 mtr and depositing where directed.

40

-

-

... More
M&L for cleaning existing reinforcement bars with wire brush/rotary wire brush making the surface free from cement skin, loose particle, dirt etc and applying rust remover (Rustoff 100 of Sika/ '8832GM' pidilite or equivelent of Fosroc/ Dr Fixit) on the rebars and removing the loose rust particles after minimum 24 hours by wire brush, all as per manufacture's instructions, complete all as specified and as directed.

30

-

-

... More
M&L for cement based polymer modified anti corrosive rebar coating system ('Sika Top Armatec-108 " of Sika or equivalent of Dr. Fixit/ Fosroc) to existing reinforcement all as per manufacture 's instructions, complete all as specified and as directed. Note: Mode of measurment shall be affected surface area of column, beam, slab complete all as specified and as directed.

42

-

-

... More
M&L for one layer of 20 mm thick concrete (comprises composition 1:2:1 plain cement concrete i.e. One part of cement (43 Gde OPC), two part of fine aggregate and one part of 10 mm and down size trap stone aggregate) mixed with 'Sprayset SL' of Fosroc( Equivalent to Sika / Dr Fixit) 2 to 2.5% by weight of cement and 12.5 to 16.5 liter of water mixed as per manufacture's instuctions and guniting by pressure nozzle with a delivery capacity of 2.5 Kg per sqm over column , beam, roof , slab, etc complete all as specified and as directed.

42

-

-

... More
S&F hard drawn steel wire fabric, weight not exc 4 Kg per sqm , cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9 mm in dia, supplied and fixed in reinforcement, complete all as specified and as directed.

42

-

-

... More
Structural design for columns,chajjas,roof slab,beams,and other connected RCC members required to be jacketing,guniting under this schedule with & including vetting of structural design from approved Govt Engineering College/NITTTR/CBRI,complete all as specified and as directed. (i) Tenderer shall carry out the site visit to ascertain the design of column,and other RCC members, (ii) Four sets of structural drawing shall be provided to GE by contractor duly vetted as above.

1

-

-

... More
Demolition of stone slabs and kota laid bedded and pointed in any mortar of any description or thickness in floors,apron complete all as specified and as directed.

0.5

-

-

... More
Taking down carefully (aluminium) point wiring complete of any type (batten/ surface conduit or concealed) for light point, fan point, bell point socket point or power point complete with all fitting such as switches, sockets pendants, ceiling rose, round block etc complete and making good disturbed surfaces of wall, floor or ceiling with plaster of tiles or roof treatment etc and finishing the surfaces with distemper/white washing/colour washing to match with the existing surface complete all as spcified and directed.

254

-

-

... More
Taking down old U/S existing DB TPN 4 way and DB SPN 8 way including MCB/MCCB of any capacity and any size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed.

6

-

-

... More
M & L for point wiring for one light/fan/bell/buzzer point controlled by one way switch with 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) including 1.5 sqmm single core PVC insulated and sheathed multi stranded copper conductor FRLSH cable 1100 volts grade (ISI Marked) as continues earth wire in green colour to coomon earth dolly laid/drawn into and including non metalic PVC concealed conduit (medium duty, ISI marked not less than 20 mm dia) with all fittings such as tee, bends etc all as per IS terminated in & including new modular metal flush boxes of requisite module concealed in wall for mounting fittings like modular Switches, sockets, regulators etc with and including modular cover plates with frame of requisite modules all as specified and as directed: Notes:- (i) Cost of cutting/leaving forming chases for conduit, sinking for metal flush boxes and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) The quoted rates of this item shall deemed for include for modular metal flush boxes of requisite module and modular cover plate with frame of requisite module of colour as approved by GE

153

-

-

... More
(a) One pin 5 amps socket point on the same board with other switches complete

6

-

-

... More
(b) One 3 pin 5 amps socket on independent board.

81

-

-

... More
Ditto all as per item No 140 here -in- before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 2.5 sqmm single core PVC insulated and and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 2.5 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed .

12

-

-

... More
Ditto all as per item No 140 here -in- before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4.0 sqmm single core PVC insulated and and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) including 4.0 Sqmm single core PVC insulated and sheathed multistranded copper conductor FRLSH cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour complete all as specified and directed .

2

-

-

... More
S&F switch Modular type, 6 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge.

240

-

-

... More
S&F switch Modular type, 16 Amp, 1 module single pole one way, 230 Volts, Modular type complete all as specified and as directed by Engr- in -charge.

12

-

-

... More
M&L socket outlet 3 Pin 6 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge.

87

-

-

... More
M&L socket outlet 3 Pin 6/16 Amps modular type, 2/3 pin combined 2 module 230 Volts complete all as specified and directed by Engr-in-Charge.

12

-

-

... More
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and as directed by engineer-in-charge.

2

-

-

... More
S&F ceiling rose, surface backelite , three terminal AC, 230 volt complete all as specified.

109

-

-

... More
Taking down and re-fixing tube light fitting, 1x 20 watts, 230 volt, basic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic driver, pre-wired and fixed on walls with all fixing accessories such as screws, clips etc and connecting up with two core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge.

89

-

-

... More
Supply and fixing LED mirror light fitting , type with high out put diffuser 2 feet, 5watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.

4

-

-

... More
Supply & fix LED bulk head ,09W / 10 W, IP65 diacast aluminium housing powder coating finished 0.9 complete all as specified and directed by Engineer-in-charge.

8

-

-

... More
M & L Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-charge.

22

-

-

... More
Taking down fan,sealing cable end, dismantling blades of any make, any sweep, and refixing after necessary repairing such as winding of motor, replacement of capacitor & ball bearing of ceiling fan, cleaning all dust & painting with existing colour synthetic enamel paint by spraying including filling cavities with filler,one coat including writing MES No. all as specified and directed by Engr-in-charge

22

-

-

... More
supply and fixing fan step regulator modular type,120W -2 module electronic socket type five step controlled 230V AC 50 Hz for complete all as specified and directed by Engr-In-Charge.

22

-

-

... More
Taking down Exhaust fan,sealing cable end,dismantling blades of Exhaust fan of any make, any sweep, deposited to store

4

-

-

... More
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep with, blades, and frame and louvers complete all as specified and as directed

4

-

-

... More
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete.

4

-

-

... More
S&F GI bracket made out of 40 mm bore GI pipe light grade /medume grade, ISI marked, medium grade 1.2m long bent to shape suitable for fixing of street light fitting including with 2 Nos MS clamps made with 40x5mm flat iron, bolts, nuts, washers etc including two coats of synthetic enamel paint over one coat of zinc chrome primer and fixing on electric pole complete all as specified and as directed by Engr-in-charge.

4

-

-

... More
Dismantling & disconnecting the existing Solar water heater of capacity 300 Ltrs from the existing location and transport to workshop and return back after repair work,re-installation and testing complete after fixing in original location comprising of Minor fitting(Rubber washers,union,socket etc) including replacement of existing flat plate collector defective glass tubes including copper capillary tubes,existing sun rays absorber film coating,solar water heating element 3000 watt,temperature dial gauge,descaling of complete unit comprisng absorber panel,pipes complete all as specified and directed by Engr-In-Charge.

2

-

-

... More
S&F sheet metal enclosure MCCB/MCB DB, double door, vertical TPN 4 way with 200 Amps rated busbar all as specified and as directed.

1

-

-

... More
S & F double door, sheet metal enclosure, powder coated for MCB DB SPN 12 way fitted with neutral link, earth bar , din rail and 200 amps rated bus bar 230 volt conforming to IS 13032-1991 complete all as specified and as directed by Engr-in-charge.

4

-

-

... More
S & F MCB SP, 5-32 Amps , 240 volts, breaking capacity 10KA complete all as specified and as dircted by Engr-in-charge.

52

-

-

... More
S&F MCB SPN, 5-32 Amps, 240 volts, breaking capacity 16KA complete all as specified and as dircted by Engr-in-charge.

4

-

-

... More
S&F MCCB 4 Pole, 415 volts, 16 KA, 100 Amps complete all as specified and as directed by Engr-in-charge.

1

-

-

... More
M&L for submain wiring with 2 runs of 6.0 Sqmm (nominal area) size main cable & 1 runs of 6.0 Sqmm size earth continuity conductor single core PVC insulated unsheathed FRLSH multistranded copper conductor 1100 volt grade ISI marked cable drawn through & including suitable size of heavy duty non metalic rigid PVC concealed conduit ISI marked & conduit fittings/accessories, fixede concealed in wall/ceiling including dismantling & taking down old unserviceable sub main wiring complete all as specified & directed. Note :-(i) 02 runs of 6.0 Sqmm size main cable, 01 run of 6.0 Sqmm size earth continuity conductor cable & Conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall be included in quoted rate of this item.

125

-

-

... More
M&L for Earthing complete with galvanized steel earth plate electrode 60cm x60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level connecting to the galvanised earth lead wire 4.0 mm dia by means of bolts, nuts check nuts and washers of galvanized iron and steel earth wire protected by provision of GI mediumgrade pipe 15mm bore including provision of concrete pit made with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4Kg/Sqm) and frame of angle iron 40x 40x6 mm and handle of 6mm dia MS bar made to shape, GI light grade 20mm bore pipe for watering perforated at bottom, 1.75meter long placed on top edge of earth plate, common salt & charcoal filling with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returing filling in and removal of surplus soil to a distance not exceeding 50 meters all as per electrical plate No -5 of SSR 2009 Part-I and connecting to Lighting protection earth test points all as specifed and directed including testing on completion.

2

-

-

... More
Supply & Laying & commissining of LT UG cable XLPE sheathed PVC insulated, screened PVC bedded, galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade, laid in tranches, in GI pipe, including brass cable glands, clamps etc of size 3.5 core x 50 Sqmm complete all as specifed and as directed. Make : Polycab/KEI/Havells Note: Earthwork, sand cushioning, bricks, GI pipe, etc will be measured and pad under appropriate items.

70

-

-

... More
Excavation in trenches n. exc 1.5 m in depth and not exc 1.5 m wide for laying of UG cable / pole etc and getting out including forming bottom surface to required level and gradient in soft/dense soil complete all as specified and as directed.

40.5

-

-

... More
Returning filling in, excavated soil including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified.

29.37

-

-

... More
Removing excavated materials/soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point complete all as specified and as directed by Engr-in-charge.

11.13

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, class HVP,type 1 with peak, size 250mm x 150mm x 40mm complete all as specified and directed by Engineer-in-charge.

350

-

-

... More
M&L for Sand Cushioning (dry) in trenches/ducts for protection of UG Cables (below, above and around the UG Cable laid in Trenches) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed. Note : For the purpose of payment, punned thickness of sand cushioning only shall be measured and paid for.

4.05

-

-

... More
Supply and fixing GI Pipe light grade og Size 40 mm bore with all fittings for passing of cables fixed to pole/wall/laid under floor or roads including all fixing accessories complete for protection of cable all as specified and directed. Make: Jindal/ Bansl/Tata

10

-

-

... More
Supply, laying and jointing GI tubes, medium grade 25mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in trenches/wall complete all as specified and directed by Engr-in-charge for the following sizes:-

70

-

-

... More
Supply, laying and jointing GI tubes, medium grade 20mm dia in lengths with screwed and socket joints together with all galvanised steel fittings such as bends, elbows, tees, union, short pieces, connectors, check nuts, caps, plugs etc fixed complete laid in trenches/wall complete all as specified and directed by Engr-in-charge for the following sizes:-

50

-

-

... More
Cutting existing steel tubing for alterations or additions done in position without taking down for 10mm to 50 dia pipe (Each cut measured)

3

-

-

... More
S&F Gun metal gate valve 25 mm bore with iron wheel head screwed both ends for iron pipes complete all as specified and directed for the following sizes-

3

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.