Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 88,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_672241_2Tender No
8856E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
REPAIR OF LT PANEL, BUS BAR AND OTHER ALLIED WORKS IN SOUTHERN SECTOR AT MIL STN KOTA
REPAIR OF LT PANEL, BUS BAR AND OTHER ALLIED WORKS IN SOUTHERN SECTOR AT MIL STN KOTA
REPAIR OF LT PANEL, BUS BAR AND OTHER ALLIED WORKS IN SOUTHERN SECTOR AT MIL STN KOTA
BOQ Items
M&L dry river clean Sand filling in trenches around underground cables for earth cushion, complete all as specified and directed. (Depth of sand shall be measured after punning).
107
-
-
M&L for trenchless boring under road/hard standing & including making good as per the existing complete all as directed. Note :- GI pipe shall be measured and paid separately under respective item of this BOQ.
30
-
-
M&L for pulverized fuel Ash-lime bricks (Fly ash bricks - non modular size), class 10, laid dry and flat adjoining each other over sand cushion in trenches as protection to UG cable, complete all as specified and directed.
10.65
-
-
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint & including dismantling of old unserviceable cross arms of MS channel or angle sections etc complete all as specified and directed.
0.5
-
-
M&L for pin type, porcelain, vitreous, white , borwn or green insulator, including one galvanised mild steel spindle, two galvanised mild steel spindle, two galnvanised iron wahers and one galvanised iron nut, 100 mm height, 65 mm dia & including dismantling of old unserviceable insulator, complete all as specified and directed.
20
-
-
M&L for insulator disc type porcelain, vitreous, 100 mm high and 115 mm dia ball and socket type, white, brown or green, two in series assembly for tension with tension clamps for conductor, working pressure 1100 volts & including dismantling of old unserviceable insulator, complete all as specified and directed.
20
-
-
S&F in renewal of stay assembly complete comprising & including of galvlanised steel stay wire stranded 7/4 mm galvanised steel stay bow 400x20mm stay rod, 1800 mm long, 20 mm dia with nuts, bolts and washers, steel plate 300x300x6.0 mm two Nos thimble, including loop type insulator size 90 x 140 mm clearance hole of 20 mm dia including necessary excavation, earth work in any type of soil, PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation, disposal of surplus soil upto a distance of 50 m and fixed to stay clamp, complete all as specified in electrical plate No 1 of MES SSR part I and directed. (Stay clamps shall be measured separately in MS Work).
4
-
-
Supply, straining, streching and fixing ACSR conductor on HT/LT poles or on existing poles including binding and jointing to conductor/ insulator with and including suitable size of copper binding wire or aluminium tape and testing & including dismantling of ACSR conductors from the poles, complete all as specified and directed.
0.5
-
-
M&L for earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized iron earth wire of 4mm dia by means of bolts, nuts, check nuts and washers of galvanized iron including 15 mm bore light grade GI tubing for protection of earth wire, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old u/s earthing complete all as specified and directed.
Notes: - (a) Irrespective of whatever is shown in plate No 3 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth wire upto 7.5m.
5
-
-
M&L for Earthing with galvanized steel earth plate electrode of size 600 mm x 600mm x 6.0 mm, buried directly in ground (earth plate not less than 2.25 Mtr below normal ground level) connected to galvanized earth strip of 25x4 mm dia by means of bolts, buts, check nuts and washers of galvanized iron on steel including 50 mm bore light grade GI tubing for protection of earth strip, MS sheet metal funnel with wire mesh, watering pipe medium grade 20 mm bore, charcoal or coke and common salt in alternative layer of 15 Cm compacted thickness all around the electrode with concrete earth pit of PCC 1:3:6 type 75 mm thick precast RCC (1:2:4) type B1 pit cover reinfored with 8 mm dia deformed bar and suitable handle made of 10 mm dia round bar including GI earth strip of 32x6 mm size for extension of earth lead and necessary excavation, earth work, in soft/loose soil and disposal of spolis to a distance not exc 50 Mtr and necessary connection and testing complete all as shown in electrical plate No. 3 and including dismantling of old u/s earthing complete all as specified and directed.complete all as specified and directed. Notes: - (a) Irrespective of whatever is shown in plate No 3 of SSR, earth pit shall be casted in PCC (1:3:6) type C-1 and precast cover of RCC (1:2:4) type B-1 with suitable handle. (b) Item includes the cost of GI pipe for protection of earth wire and earth lead strip upto 7.5 m.
10
-
-
S&F in renewal of earth continuity conductor or main earthing lead 4mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.
20
-
-
S&F in renewal of galvanised iron earth strip of size 25x4 mm, fixed to wall or pole, complete all as specified and directed.
30
-
-
S&F in renewal of 50 mm bore steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
25
-
-
S&F in renewal of 80 mm bore steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
30
-
-
S&F in renewal of 100 mm bore steel water tubing, light grade, galvanised, with all fitting, laid in trenches/fixed to walls/poles etc as protection to cables, with and including necessary MS clamps, nuts botls, washers etc required for fixing, complete all as specified and directed.
20
-
-
Supplying, laying, jointing, testing and commisioning XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 1100 Volt grade (ISI marked), laid in trenches / ducts / encased in GI pipe / fixed to pole/wall with necessary angle iron support, clamp, nut , bolts etc and including taking down of old unserviceable existing UG cables complete all as specified and directed for following cross sectional areas of cables :- Notes for Srl item Nos. 18.10 to 18.70 :- (i) Excavation, earth work, sand cushioning, cable protection cover & GI pipes shall be measured and paid for separately under respective items of BOQ. (ii) Quoated rate shall be deemed to be inclusive of connecting up with control gear including cable glands and cable lugs.
Cross Sectional area of cable 16 Sq mm 4 core
250
-
-
Cross Sectional area of cable 25 Sq mm 4 core
300
-
-
Cross Sectional area of cable 70 Sq mm 3.5 core
200
-
-
Cross Sectional area of cable 95 Sq mm 3.5 core
150
-
-
Cross Sectional area of cable 150 Sq mm 3.5 core
150
-
-
Cross Sectional area of cable 185 Sq mm 3.5 core
200
-
-
Cross Sectional area of cable 240 Sq mm 3.5 core
200
-
-
Supply, transporting, erection and fixing steel tubular swaged pole, 9.00 metres long, type 410 SP-31, complete with cast iron base plate, pole cap, finial taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:3:6 type C2, using 40 mm graded stone aggregate and PCC 1:2:4 type B1, using 20 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting the pole with two coats of aluminium paint over one coat of red oxide primer including 3 nos band/straps with red post office box colour (300mm wide each) synthetic enamelled paint at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete & including taking down existing old unserviceable poles and complete all as specified and directed.
5
-
-
M&L for painting the external exposed surfaces of steel tubular swaged/rail poles of 9.0 metres long alongwith cross arms, bracket and connected accessories with one coat of aluminium paint including preparation of old painted surfaces and writing the details of the pole in white letters on black back ground and pasting 100 mm wide reflective red strickers in 3 lines around the pole, complete all as specified and directed.
150
-
-
S&F in renewal of PVC line spacers to LT over head line poly propylene compositor phase sepraters moulded bolted type suitable for 4 line, complete all as specified and directed.
10
-
-
S&F in renewal of PVC line spacers to LT over head line poly propylene compositor phase sepraters moulded bolted type suitable for 3 line, complete all as specified and directed.
10
-
-
M & L for cutting of bushes and cleaning the area around the sub station & surface dressing n exc 10 cm deep & including two pole/four pole structures premises at southern sector and cutting the bushes, complete all as specified and directed.
2000
-
-
M & L for trimming /cutting of tree branches to provide proper clearance around existing HT over head line with clearance of 3 mtr on both the sides from the centre of OH line all as per technical requirement & including removing of cut tree branches from site and depositing at places complete all as specified and directed.
290
-
-
Restretching of existing aluminium conductor steel reinforced (ACSR) straining properly on insulators and binding with aluminium tape/binding wire connectors, PG clamps, jumpers etc, complete all as specified and directed for any size of ACSR conductor. Note:- Each ACSR conductor in a circuit will be measured & paid sepretely.
1000
-
-
S&F in renewal of aluminium lugs, properly crimping and taping different colours, complete all as specified and dircted for the following size of cables: -
185 Sqmm
100
-
-
150 Sqmm
100
-
-
120 Sqmm
100
-
-
95 Sqmm
100
-
-
70 Sqmm
100
-
-
50 Sqmm
100
-
-
35 Sqmm
125
-
-
25 Sqmm
150
-
-
16 Sqmm
150
-
-
S & F in renewal for MCCB, four pole, 415 Volts, 400 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
1
-
-
S & F in renewal for MCCB, four pole, 415 Volts, 250 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
3
-
-
S & F in renewal for MCCB, four pole, 415 Volts, 200 Amp, ultimate breaking capacity 36 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
4
-
-
S & F in renewal for MCCB, four pole, 415 Volts, 160 Amp, ultimate breaking capacity 25 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
4
-
-
S & F in renewal for MCCB, four pole, 415 Volts, 100 Amp, ultimate breaking capacity 25 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
5
-
-
S & F in renewal for MCCB, four pole, 415 Volts, 63 Amp, ultimate breaking capacity 10 KA, 50 Hz, AC and confirming to IEC: 60947- II /IS - 13947-II with adjustable thermal and adjustable magnetic setting, complete all as specified and directed.
5
-
-
Supply only electrical insulating tape roll of length 25 metre and width 20 mm having high performance strength and good adhesive characteristics, complete all as directed.
300
-
-
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 3.15 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 250 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x300 mm, including with provision of fixing incoming MCCB for addition & connection with LT cable with appropriate lugs and including angle iron stand of appropriate size complete all as specified and directed. Note :- Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.
4
-
-
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 3.15 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 300 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x300 mm, including with provision of fixing incoming MCCB for addition & connection with LT cable with appropriate lugs and including angle iron stand of appropriate size complete all as specified and directed. Note :- Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.
4
-
-
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 3.15 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 400 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x300 mm, including with provision of fixing incoming MCCB for addition & connection with LT cable with appropriate lugs and including angle iron stand of appropriate size complete all as specified and directed. Note :- Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.
4
-
-
S&F in renewal of bus bar chamber, 4 pole, factory made using CRCA sheet of 3.15 mm thickness and epoxy powder coated with locking arrangements, comprising of 4 Nos aluminium strip bus bars of adequate length, air insulated and PVC sheathed capacity 500 Amps rating with colour coding and mounted on porcelain insulators housed in a box of size 800x600x300 mm, including with provision of fixing incoming MCCB for addition & connection with LT cable with appropriate lugs and including angle iron stand of appropriate size complete all as specified and directed. Note :- Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.
4
-
-
S & F in renewal of service wire of size 6 Sqmm 2 core of aluminium conductor PVC sheathed, confirming to latest IS/IEC complete all as specified and directed.
360
-
-
S & F in renewal of service wire of size 4 Sqmm 2 core of aluminium conductor PVC sheathed,confirming to latest IS/IEC complete all as specified and directed.
360
-
-
Disconnection of power supply from existing LT Panel of any type, disconnection of earth strips, cutting of the foundation angles/channels, removing of the panel from the site, including MS iron form work for raising the height of the panel upto the height as directed by the Engineer-in-Charge, including painting of LT panel complete with inner & outer with two coats of synthetic enamelled paint using spray painting machine, re-installation of panel, including repair to foundation of panel, restoration of power supply, including necessary excavation & earth work required for taking out & re-fixing the incoming and out going cables etc, complete all specified and directed. Note :- The MS form work deemed to be included in the quoted rate.
15
-
-
M & L for repair to existing LT Panel of any type/ size, with cutting necessary worn out portion of MS sheet, angle iron and providing MS sheet of 2mm thick for renewal of rusted/broken LT panel door, MS angle iron of existing size and hinges to broken door, fixed with electric arc welding, providing external locking arrangement after taking proper electric shutdown, including rewiring by copper conductor control cables of suitable size, renewal of burnt out aluminium lugs and fixing with new lugs, nuts bolts etc, including painting of LT panel complete with inner & outer with two coats of synthetic enamelled paint using spray painting machine complete all specified and directed. Note :- Material such as MS sheet, angle iron, hinges deemed to be included in the quoted rate.
10
-
-
M & L for repair to existing LT feeder pillar of any type/ size, with cutting necessary worn out portion of MS sheet, angle iron and providing MS sheet of 2mm thick for renewal of rusted/broken LT panel door, MS angle iron of existing size and hinges to broken door, fixed with electric arc welding, providing external locking arrangement after taking proper electric shutdown, including rewiring by copper conductor control cables of suitable size, renewal of burnt out aluminium lugs and fixing with new lugs, nuts bolts etc, including painting of LT panel complete with inner & outer with two coats of synthetic enamelled paint using spray painting machine complete all specified and directed. Note :- Material such as MS sheet, angle iron, hinges deemed to be included in the quoted rate.
15
-
-
Disconnection of electric connection from existing LT Panel/LT feeder pillars panel of any size, dressing of cable ends including repair of body of LT panel, repair/welding work of gates, hinges of the door including rewiring by copper conductor control cables of suitable size, renewal of burnt out aluminium lugs and fixing with new lugs, nuts bolts etc, including painting of LT panel complete with inner & outer with two coats of synthetic enamelled paint using spray painting machine & necessary welding work if required & including necessary excavation & earth work required for taking out & re-fixing the incoming and out going cables etc, complete all specified and directed.
20
-
-
Labour for disconnecting LT cable of any size from structure/pole for finding fault and defect rectification LT cable laid in trenches or any location by locating fault with the help of electronic fault machine comprising of surge generator pulse, ECHO fault locator with high frequency distance calculator etc., (the entire repair work to be completed within 12 hrs of instruction) complete complete all as specified and directed. Note: The complaints will be notified to contractor on mobile phone at any time between 0800 to 2200 Hrs and has to be rectified within 12 Hrs after notification, failing to which Rs. 500/- per day complaint will be recovered, fault locating with electronic fault locator, excavation and earth work, disconnecting and reconnecting both end of cable, relaying of sand and protective cable covers are deemed to be included in the quoted rate.
25
-
-
M&L for straight through jointing kits heat shrikable type LT UG XLPE cable heavy duty armoured sheathed & including excavation in any type of soil/strata, taking out cable & making disturbed surface after relaying the cable making joints suitable for aluminium conductor of following size complete all as specified and directed :-
-
-
-
10 Sqmm to 16 Sqmm 4 core
10
-
-
25 Sqmm to 50 Sqmm 3.5 core
10
-
-
70 Sqmm to 120 Sqmm 3.5 core
10
-
-
150 Sqmm to 185 Sqmm 3.5 core
11
-
-
Supplying, installation, commissioning and testing (including CPRI type test certified) of outdoor type, weather proof, factory made LT feeder pillar box (Kiosk) of appropriate size (OR as per Indian Electricity Rules), protection class IP-65 made of 3.15 mm thick CRCA sheet duly powder coated, having double door opening (front & rear) with locking arrangement, provision of entry & exit CP brass glands for cables, having bus bar chamber with 4 No heat shrink insulated aluminium bus bar of 600 Ampere capacity and including all connection with aluminium busbar strip, provided with danger notice plate with skull & bone sign, including making all electrical incoming and outgoing electrical cable connection with new lugs, gland to be provided at cable entries and including 40x40x6mm thick angle iron frame work at the base of panel only for grouting purpose & necessary cement concrete 1:2:4 type B1 for grouting of panel stand and connecting the panel with existing earthing and including dismantling of old u/s existing panel comprising of the following: -
(A) INCOMING: - (a) Aluminium bus bar of rating 600 Amps for four pole - 01 Set
(b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 400 Amp rating with rupturing capacity 36 KA microprocessor control type– 01 No.
(c) Electronic digital type Ampere meter, 0-500 Amp with selector switch upto 500 Amp & 3 Nos CT's ration 250/5 copper wound, square 96x96 mm - 01 No.
(d) Electronic digital type Volt meter, 0-500 volts, square 96x96 mm with selector switch - 01 No.
(e) Phase indicator LED type indicating lamp (RYB) with copper control wiring - 01 set of three.
(B) OUTGOING :- (a) MCCB, 4 pole, 415 volts, 50 Hz, AC, 160 Amp rating with rupturing capacity 25 KA adjustable thermal & adjustable magnetic settings mounted on din rail – 02 Nos.
(b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 100 Amp rating with rupturing capacity 25 KA adjustable thermal & adjustable magnetic settings – 01 No.
(c) MCCB, 4 pole, 415 volts, 50 Hz, AC, 63 Amp rating with rupturing capacity 16 KA adjustable thermal & adjustable magnetic settings – 03 Nos.
Note :- (i) Necessary approval of drawings of LT feeder Pillars shall be approved by GE before placing order by the Contractor.
(ii) Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.
(iii) Cost of above aspects is deemed to be included in quoted rates.
2
-
-
Supplying, installation, commissioning and testing (including CPRI type test certified) of outdoor type, weather proof, factory made LT feeder pillar box (Kiosk) of appropriate size (OR as per Indian Electricity Rules), protection class IP-65 made of 3.15 mm thick CRCA sheet duly powder coated, having double door opening (front & rear) with locking arrangement, provision of entry & exit CP brass glands for cables, having bus bar chamber with 4 No heat shrink insulated aluminium bus bar of 800 Ampere capacity and including all connection with aluminium busbar strip, provided with danger notice plate with skull & bone sign, including making all electrical incoming and outgoing electrical cable connection with new lugs, gland to be provided at cable entries and including 40x40x6mm thick angle iron frame work at the base of panel only for grouting purpose & necessary cement concrete 1:2:4 type B1 for grouting of panel stand and connecting the panel with existing earthing and including dismantling of old u/s existing panel comprising of the following: -
(A) INCOMING: - (a) Aluminium bus bar of rating 800 Amps for four pole - 01 Set
(b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 630 Amp rating with rupturing capacity 50 KA microprocessor control type– 01 No.
(c) Electronic digital type Ampere meter, 0-500 Amp with selector switch upto 500 Amp & 3 Nos CT's ration 250/5 copper wound, square 96x96 mm - 01 No.
(d) Electronic digital type Volt meter, 0-500 volts, square 96x96 mm with selector switch - 01 No.
(e) Phase indicator LED type indicating lamp (RYB) with copper control wiring - 01 set of three.
(B) OUTGOING :- (a) MCCB, 4 pole, 415 volts, 50 Hz, AC, 250 Amp rating with rupturing capacity 36 KA adjustable thermal & adjustable magnetic settings mounted on din rail – 02 Nos.
(b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 100 Amp rating with rupturing capacity 25 KA adjustable thermal & adjustable magnetic settings – 02 Nos.
(c) MCCB, 4 pole, 415 volts, 50 Hz, AC, 63 Amp rating with rupturing capacity 16 KA adjustable thermal & adjustable magnetic settings – 02 Nos.
(b) MCB, 415 volts, AC, three pole & neutral, 32 Amp, breaking capacity 10 KA – 02 Nos.
Note :- (i) Necessary approval of drawings of LT feeder Pillars shall be approved by GE before placing order by the Contractor.
(ii) Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.
(iii) Cost of above aspects is deemed to be included in quoted rates.
2
-
-
Supplying, installation, commissioning and testing (including CPRI type test certified) of outdoor type, weather proof, factory made LT feeder pillar box (Kiosk) of appropriate size (OR as per Indian Electricity Rules), protection class IP-65 made of 3.15 mm thick CRCA sheet duly powder coated, having double door opening (front & rear) with locking arrangement, provision of entry & exit CP brass glands for cables, having bus bar chamber with 4 No heat shrink insulated aluminium bus bar of 400 Ampere capacity and including all connection with aluminium busbar strip, provided with danger notice plate with skull & bone sign, including making all electrical incoming and outgoing electrical cable connection with new lugs, gland to be provided at cable entries and including 40x40x6mm thick angle iron frame work at the base of panel only for grouting purpose & necessary cement concrete 1:2:4 type B1 for grouting of panel stand and connecting the panel with existing earthing and including dismantling of old u/s existing panel comprising of the following: -
(A) INCOMING: - (a) Aluminium bus bar of rating 400 Amps for four pole - 01 Set
(b) MCCB, 4 pole, 415 volts, 50 Hz, AC, 160 Amp rating with rupturing capacity 25 KA microprocessor control type– 01 No.
(c) Electronic digital type Ampere meter, 0-500 Amp with selector switch upto 500 Amp & 3 Nos CT's ration 250/5 copper wound, square 96x96 mm - 01 No.
(d) Electronic digital type Volt meter, 0-500 volts, square 96x96 mm with selector switch - 01 No.
(e) Phase indicator LED type indicating lamp (RYB) with copper control wiring - 01 set of three.
(B) OUTGOING :- (a) MCCB, 4 pole, 415 volts, 50 Hz, AC, 63 Amp rating with rupturing capacity 16 KA adjustable thermal & adjustable magnetic settings mounted on din rail – 04 Nos.
(b) MCB, 415 volts, AC, three pole & neutral, 32 Amp, breaking capacity 10 KA – 02 Nos.
Note :- (i) Necessary approval of drawings of LT feeder Pillars shall be approved by GE before placing order by the Contractor.
(ii) Height of the angle iron stand must be 1.25m above the ground level to avoid water logging being low laying area.
(iii) Cost of above aspects is deemed to be included in quoted rates.
2
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%