Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Civil And Construction
Building Construction
Eprocure
Opening Date14 Nov 2024
Closing Date6 Dec 2024
Tender Amount₹ 35,26,000
Costs
EMD
₹ 70,550Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_683886_1Tender No
8935-25/GE/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Taking down cement plaster from brick wall or concrete surfaces or ceiling including raking out joints, hacking for key & scrubbing down with water etc complete all as specified and directed.
1600
-
-
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:6 on wall, finished fair even and smooth all as specified and directed.
950
-
-
M&L for rendering 15mm thick on brickwork or concrete surfaces in cement mortar 1:4 on wall with WPC finished fair even and smooth all as specified and directed.
300
-
-
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-charge.
85
-
-
M & L rendering 10 mm thick in cement mortar (1:4) on fair faces of concrete surfaces of ceiling finished fair and even without using extra cement complete all as specified & directed by Engr-in-charge.
350
-
-
M&L for two coats of acrylic distemper on newly plastered surfaces of walls over and including one coat of primer and 3mm thick wall care putty including preparation of surfaces complete all as specified and directed.
950
-
-
M&L for complete removal of existing treatment and two coats of acrylic distemper over and including one coat of primer and 3 mm thick wall care putty on plastered surfaces of walls including preparation of surfaces complete all as specified and directed by Engineer-in-Charge.
850
-
-
M&L for 3 coats of white wash on newly plastered surfaces on ceiling incl preparation etc. complete all as specified and directed.
350
-
-
M&L for two coats of white wash on old plastered surfaces on ceiling incl preparation etc. complete all as specified and directed.
175
-
-
Material and labour for preparing newly plastered or pointed surface of wall by sand papering or by any other mean and after preparing the surfaces applying three coats of white wash complete all as specified & directed by Engineer-in- charge
50
-
-
M&L for preparation of new plastered and applying two coats of weather proof exterior emulsion paint (Apex ultima or equivalent) over a coat of primer over 3 mm thick wall care putty complete all as specified and directed by Engineer-in-charge.
300
-
-
M&L for complete removal of existing finishes and treating with two coats of weather proof exterior emulsion paint (Apex ultima or equivalent) over a coat of primer over 3mm thick wall care putty complete all as specified and directed by Engineer-in-charge.
75
-
-
Providing and Applying rising damp proof coating system with single component ready to use damp proof coating Roff Hydamp
1. Preparation :- Throughly brush and clean all laitance, loose particles such as dirt, grease, mortar droppings, release agents, efflorescence, bird droppings, etc all large voids and hallow portions must be removed and re-plastered non moving cracks having width upto 5mm must be filled with polymer based crack filler.
2. Application :- Apply the first coat of Dr. fixit dampguard classic with a paint brush directly on the prepared surfaces by mixing (1 part base : 1 part hardner : 1 part of water), allow to dry for a minimum 2-3 hrs. apply one part of Dampguard mixed chemical and 2 parts of OPC white cement / Birla putty and make the putty, apply putty on the entire surface area, allow to dry for at least 3-4 hrs, apply the final coat of air cure 48 hrs proceeds for paints.
20
-
-
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc. complete all as specified and directed by Engineer-in-Charge.
220
-
-
Dismantling floor,hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified & directed.
467
-
-
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.36 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
235
-
-
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.18 Sqm but not exc 0.38 Sqm as in dado/skirting over and including 10 mm thick rendering on vertical surface in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and directed.
40
-
-
M&L for joint free non skid ceramic coloured tiles 7 to 8 mm thick (square/ rectengular) area of each tile exc 0.11 Sqm but not exc 0.18 Sqm in floor over and including 15 mm thick screed bedding in cement mortar 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match the floor all as specified and directed.
52
-
-
M&L for glazed ceramic coloured tiles of size 450 x 350 x 7 mm thick on vertical surfaces such as skirting / dados over and including 10 mm thick backing coat in cement mortar 1:4, set and jointed in neat cement slurry and pointed in coloured cement to match the floor complete all as specified and directed by Engneer -in-Charge
140
-
-
Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc and laided, bedded and pointed in any mortar complete all as specified and directed.
7.45
-
-
M&L for 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 20 mm thick screed bed in CM 1:6 complete all as specified and directed.
15
-
-
Rounding off edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations all as specified and directed
30
-
-
M&L for machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed with grey cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as directed.
48
-
-
M&L for machine cut kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over and including 10 mm thick backing coat in cement mortar 1:4 set and jointed in neat cement slurry mixed with pigment to match shade of the slab including rubbing and plishing complete all as directed.
11.5
-
-
Formwork to chajjas, troughs and similar items including edges , for rough surface of concrete, complete all as specified and directed by Engineer-in-charge
15
-
-
M&L for reinforced cement concrete 1:1.5:3 type A-1 using 20mm graded stone aggregrate in Chajjas; complete all as specified and directed by Engr-in-charge.
Note : Reinforcement shall be measured and paid seperately.
1
-
-
S & F TMT Bars (Fe-500D) 10 mm dia and over, cut to length, bent to shape required, including cranking spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
90
-
-
S&F for TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified and directed.
30
-
-
M&L for 75 mm thick PCC 1:3:6 type C-2 using 40 mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10 mm wide, 30 mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as directed.
65
-
-
M&L for continous brick edging; with burnt bricks old size bricks, with width equal to the width of the brick; liad dry on end vertically complete all as specified and directed by Engr-in-Charge.
85
-
-
Material and labour for creating fillet caving 50 x 50 mm with ploymer modified mortar on the junction of slab and wall as per manufacture insructions, M & L providing for applying two coats of two components (1 Part Liquid : 2 Part powder) ready to use cemetitious waterproof cating on properly perepared surface by brush having elongation of 50% for the applying water proofing treatment as per following and complete all as directed by the Engineer-in-charge. (i) Applying 1st coat of two components modified polymer coating on horizontal and vertical surfaces.
(ii) Applying of glasses fiber mesh of 2x2 mm immediately on alone coating. (iii) Applying 2nd coat of two components modified polymer coating after 72 hrs on horizontal and vertical surfaces. Note : Complete treatment to be carried out by authorized applicator of water proofing manufactures
30
-
-
M&L for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as filling of sunken floors/bottom and side of drain complete all as specified & directed by Engr-in-charge.
1.6
-
-
Dismantling of Brick tiles in floor or roof laid dry and pointed in cement morter complete all as specified and as directed by engineer-in-Charge.
20
-
-
Demolition mud in roofs, any thickness, including plastering and leeping and including rubbish off the premises complete all as specified and directed.
20
-
-
M & L for 40 mm thick cement concrete 1:2:4 type B-0, using 12.5mm graded stone aggregate as in roof Padding etc and slope 1:40 complete all as specified and directed by Engineer-in-Charge.
200
-
-
M&L for Roof treatment to RCC roof as follows:-
(a) Cleaning the roof surfaces thoroughly using wire brusehes to remove sharp projections, cleaning joints, washing, drying and removing all dirt/dust to receive concrete padding/plaster etc. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. (c) Providing one coat of approved bituminous primer @100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP membrane,(mineral finish) reinforced with non woven polyster fabric, by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by E-in-Charge.
Notes : (i) All joints and change in directions should be covered wih cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/as per site reqmt and cured well before laying membrane by torching.(ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only. The name of firm shall be got approved from GE before carrying out the wk. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarnatee of treatment shall be for min 10 yrs reckoned from date of completion of whole wk.
200
-
-
M&L PCC 1:2:4 type B-1, using 20mm graded stone aggregate as in roof kerbs or mud stops, and like rounded or chamfered on edges including necessary form work etc complete all as specified and directed by Engr-in-Charge.
1
-
-
Material and labour for repair to damage RCC coloumns/Beam/Slab/Chajja by using micro mortar and concrete in Following Stages :-
(a) Removing the mortar and loose concrete from RCC elements.
(b) Cleaning the rusted reinforcements and applying rust removal.
(c) Inserting the addl reinforcements in case the coves sectional area reduction is more than 20 percent by welding the reinforcement with existing bars and supporting adequate on walls if reqiurd with grout.
(d) Providing micro mortar and concrete over bond coat to cover the reinforcements and slet surface.
(e) Providing adequate formwork and scaffolding if required.
(f) Curing the surface. Note :- (i) Rust removal, bonding agent, grout, micro mortar and concrete and related chemicals shall be of make as per mentioned in Appx 'A'
(ii) Work is to be got executed from authorised applicator of the company.
(iii) Steel reinforment shall be measured and paid separately
42
-
-
Taking down chowkhats or frames n.exc 1.5 sq. m each with shutters (without taking off shutters from the frame) and removing from site complete all specified and directed directed.
60
-
-
Taking down chowkhats or frames exc 1.5 sq. m but n.exc 4.0 sq. m each with shutters (without taking off shutters from the frame) complete all specified and directed directed.
40
-
-
Taking down existing shutter and refixing in same opening shutters of any description exc 1.0 Sqm but not exc 2.0 Sqm each all as specified and directed.
(Note:- 'Refixing' includes taking down, easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc.)
8
-
-
Supply and fixing of Fibre glass Reinforced plastic (FRP) door frame of required colour of cross-section 90mm x 45mm having single ribate of 32mm x 15mm to recieve shutter of 30mm thick including laminated door frame moulded with fire retardant grade unsaturated polyster resin and chopped strand mat(CSM) also door frame laminated shall be 2mm thick and shall be filled with suitable wooden block of 2nd class hard wood, frame shall be covered with fibre glass from all sides. MS stay flat iron 25mm x 3mm shall be provided at the bottom to steady the frame complete all as specified and as directed by Engineer-in- charge.
68
-
-
Supply and fixing of 30 mm thick glass fibre reinforced plastic (FRP) paneled door shutter conferming to IS:14856-2000 of required colour and made with fire retardant grade unsaturated polyster resin,moulded to 3mm thick FRP laminated for forming hollow rails and style with suitable second class hardwood timber block inside at required places for fixing of fittings,cast molithically with 5mm thick FRP laminated for panels including fixing to frames,complete all as specified and as directed by Engineer-in- charge.
16
-
-
S & F for Pressed steel frames 125 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed by Engineer-in- charge.
25
-
-
Supply & fixing 30 mm thick flush shutters, solid core construction, with block board core and ply wood face panells, commercial type on both sides complete all as specified & directed by Engineer-in- charge.
30
-
-
S & F for Pressed steel frames 105 x 60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified and as directed by Engineer-in- charge.
20
-
-
S&F for 35 mm thick 2nd class hard wood factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed by Engineer-in-Charge.
15
-
-
S&F for 35 mm thick 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge.
22
-
-
S&F 100 mm long butt hinge, extruded stainless steel with stain less steel hing pin, complete all as specified and directed by Engneer -in-Charge .
45
-
-
S&F aluminium anodised barrel tower bolt of extruded section 200mm long all as specified & directed by Engr-in-charge.
109
-
-
S&F 150 mm long extruded aluminium alloy handle, fabricated type anodised complete all as specified and directed by Engneer -in-Charge .
110
-
-
S&F 100 mm mild steel pressed handles, oval type, stove enamelled black complete all as specified and directed by Engneer -in-Charge .
56
-
-
S & F 150 mm mild steel barrel bolts, stove enammelled black eith bright bolt and fixed complee all as specified and directed
52
-
-
S&F 100 mm long butt hinge, medium weight, cold rolled mild steel complete all as specified and directed by Engneer -in-Charge .
195
-
-
S&F for 300 mm long mild steel sliding door bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
28
-
-
S&F 300mm ordinary rat tail rod pattern springs including roller and roller plate complete mild steel fixed complete all as specified and directed.
14
-
-
S & F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engr-in-Charge.
25
-
-
S & F 4.00 mm thick sheet glass, ordinary quality and glazing with aluminium snap beading of any size of glass in each pane all as specified and directed.
21
-
-
S&F for 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring all as directed.
36
-
-
M&L for preparation of new or previously untreated wooden surface of any description not otherwise described over 10 cm width or girth and apply two coats of synthetic enamel paint over one coat of pink primer all as specified.
190
-
-
M&L for preparation of old wooden surface of any description not otherwise described over 10 cm width or girth and apply one coats of synthetic enamel paint all as specified.
55
-
-
S&F for powder coated aluminium frame for doors, windows, ventilators and aluminium partition with one or more rebates including jointing cleats glazing clips, rubber packing, anodised aluminium snap beading, screws etc complete with locking arrangements for fixing with powder coating on aluminium sections, minimum thickness of powder coating shall be 50 micron as per the specification. The top and bottom horizontal members and vertical members adjacent to wall shall be fixed with floor, ceiling, walls and cills where required and fixed with the help of rawl plugs and screws or with fixing clips or with expansion hold plate fastners. Aluminium section shall be smooth, rust free, straight, mitred and jointed mechanically whereever required complete in all respect all as specified & directed by Engr-in-Charge.
70
-
-
S&F for powder coated anodised aluminium door shutters,, aluminium sections weighing exc 0.55 Kg/m including necessary necessary joining cleats, glazing clips, rubber neoprene packing, handles 1 Nos in each door, hinges (03 Nos), anodised aluminium snap beading, screws, complete all as specified
7
-
-
S & F for Aluminium anodised (Powder coated) Three track sliding window frame with shutters (two glazed and one gauged shutter) including all necessary joining cleats, hold fast, rubber gasket, snap beading and locking arrangements fixed with screws to wall etc. complete and glazing with 5 mm thick tinted glass to aluminium frame work using rubber gasket and including stainless steel wire cloth of 0.36mm dia & average width of aperture 1.40mm with staple or suitable fillets wire mesh fitted with screws and washers etc with the following section of frame and shutter (A) Sections for frame (i) Top and verticals 92 x 29.50 x 1.30 mm thick (ii) Bottom 92 x 29.50 x 1.20 mm thick. (B) Sections for shutter (i) 'A' section 39 x 20 x 1.50 mm thick (ii) 'Interlock' section 39 x 20 x 1.50 mm thick(iii) 'H' section 41 x 20 x 1.10 mm thick Make: Jindal or equivalent sections of Hindalco.
25
-
-
S & F 4 mm thick figured glass, pin head secured with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
15
-
-
Material & Labour for mild steel work conforming to Fe-290 (Gde E-165) as in grills, gratings etc. with ends of bars shouldered and/ or rivetted or forged into spikes; framed guard bars, walkways, railing, framed work of water tanks and similar works complete all as directed by Engineer-in- charge
500
-
-
M & L for painting steel and iron surfaces of any discription,over 10 cm width or girth, with preparation of new or previously untreated surfaces priming with one coat of read oxide & finish with two coats of synthetic enamel paint ordinary tint all as spefified and directed by Engr-in-Charge.
50
-
-
S&F in repair drapery stainless steel rods, standrad quality, not less than 25mm dia with brackets and heads at both ends, etc. complete all as specified and directed by Engr-in-charge.
92
-
-
S & F in repair sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 mm with chromium plated bracket guard and railing 60 cm long all as specified and directed
7
-
-
S & F in repair aluminium hat peg, solid body 125 mm to 175 mm (4 Legs) complete all as specified and as directed by Engineer-in-charge.
21
-
-
S&F in repair towel rails 20mm dia 600mm long brass chromium plated complete all as specified and directed by Engineer-in-Charge.
7
-
-
S&F in repair chromium plated fancy type soap dish 10cm/15cm complete all as specified and directed by Engineer-in-Charge
7
-
-
S&F in repair vitreous china squatting pan Orissa pattern size 580 x 440 mm white with integral foot rests but including CI 'P' trap set in and including concrete fixed complete all as specified and directed by Engineer-in-Charge.
7
-
-
S&F in repairs PVC valve less, syphonic action type flushing cistern,10 ltrs capacity low level, white, with inlet ball valve, float, handle and telescopic pipe flush pipe of polyethylene of low or high density or PVC, 32mm dia, for low level cistern and connection to pipes all as directed.
7
-
-
S&F in repair vitreous china wash hand basin coloured Flat back of size 550x400mm, including 32mm dia chromium plated waste coupling long screwed shank and fly nut, flanged end bedded in red led cement and other end fixed and PVC waste pipe including cutting for and pinning in ends of brackets in CM 1:3 all as specified .
7
-
-
S&F in repair pillar tap, swan neck, fancy type, cast copper alloy chromium plated with capston head, screwed down high pressure with or without lettered with long screwed shank and fly nuts, screwed for iron pipe of 15 mm bore complete all as specified and directed. Note: Wt not less than 450 gms
7
-
-
S&F bib tap 15mm bore cast copper alloy chromium plated long body fancy type with capston head and cup screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer-in-Charge.
35
-
-
S&F in repair CP brass stop/angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup fixed complete all as specified and directed by Engineer-in-Charge.
28
-
-
S&F CP brass stop valve/ angle valve fancy type 15 mm bore cast copper alloy screwed down high pressure fancy type with long shank and cup (Concealed type) fixed complete all as specified and directed by Engr-in-charge.
7
-
-
Supply & fixing in repairs CP swivel shower roses 125mm with or without swivel joints, including fixing to steel pipe or union fixed complete all as specified and directed by Engr-in-Charge.
7
-
-
Supply & fixing 450 mm long PVC connection 15mm size with PTMT nuts complete all as specified & directed by Engineer-in-charge.
28
-
-
S&F in repair looking mirror of selected quality of size 600 mm X 450 mm with bevelled edge mounted 6 mm thick commercial plywood and aluminium channel of required size fixed to wooden plugs with chromium plated brass screws and cup washers all as directed.
7
-
-
Dismantling of water tanks of capacity exc 250 and n.exc 500 ltrs and removing from site all as specified and directed.
7
-
-
S&F for Rotational moulded polythene water storage tank 500 ltr capacity vertical with closed top, ISI marked hoisted and fixed in position all as specified in SSR part-I. including 20 mm bore PTMT float valve, connection nipple 2 Nos complete all as specified and directed..
7
-
-
S&F in repair gun metal globe or gate valve with iron wheel head, screwed both ends for iron pipe and fixed of 20mm bore complete all as specified and directed
7
-
-
S&F in repair ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in 20mm dia bore pipe complete all as specified and directed by Engr-in-charge.
7
-
-
Taking down 15 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed.
85
-
-
Taking down 20 mm dia steel GI tubing including all connectious fittings in any position including cleaning for re fixing the serviceable pipe all as directed.
120
-
-
S&F 15 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
85
-
-
S&F 20 mm dia galvanised steel tubing medium grade including necessary fittings like sockets, tees, elbows, reducers, unions etc fixed to walls / ceiling complete all as specified and directed by Engineer-in-Charge.
120
-
-
Dismantling of cast iron pipes, jointed in cement mortar and taking out of trenches/wall if required 100mm dia complete all as specified and directed by engineer-in-Charge.
60
-
-
Taking down eaves gutters and rainwater pipes/PVC SWR (any size or pattern) including all fittings, heads, shoes, bends, swan-necks etc.,complete all as specified and directed by Engineer-in-Charge. (measured overalll as fixed along the centre line over fittings and accessories)
30
-
-
S&F in repair 110 mm dia PVC SWR pipe, single socketed in any length with rubber ring joints fixed with clamps to walls complete all as specified and directed by Engineer-in-Charge.
30
-
-
S&F in repairs 32 mm dia low density polyethylene pipes (LDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors complete all as specified and directed by Engineer-in-Charge.
6
-
-
S & F in repair stainless steel kitchen plate rack made out with 1 mm thick sheet of size 24"x24"x 10" complete all as specified and directed by Engineer-in-Charge
7
-
-
S&F in repair kitchen sinks with drainage board made of stainless steel 1mm thick with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to waste pipe, overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engineer-in-Charge.
7
-
-
S & F in repair 100 bore of spun cast iron soil, waste and vent pipes in any length with or without ears, with cement joint and laid in trenches or in floors cast iron complete all as specified and directed by Engineer-in-Charge.
32
-
-
S & F cast iron 100 mm bore branch pieces, single (equal or unequal),ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
7
-
-
S & F cast iron 100 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
4
-
-
S & F in repair 75 bore of spun cast iron soil, waste and vent pipes in any length with or without ears, with cement joint and laid in trenches or in floors cast iron complete all as specified and directed by Engineer-in-Charge.
28
-
-
M & L in repairs 75 mm cast iron floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1, (1:2:4) complete all as specified and directed by Engineer-in-Charge.
14
-
-
S & F cast iron 75 mm bore branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed by Engineer-in-Charge.
7
-
-
S & F cast iron 75 mm bore Bends (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed by Engineer-in-Charge.
4
-
-
M&L for 100mm thick PCC (1:4:8) type D2 using 40mm graded stone aggregate as in sub base below floors all specified and directed.
119
-
-
M&L Machine pressed precast concrete interlocking paver block glossy with grey cement and pigment, any shape and size confirming to IS 15658-2006 of 60mm thickness M-35 grade over Fazilka sand cushion and incl dismantling all as specified and directed.
119
-
-
Supply only fine aggregate (sand) for cushioning (Fazilka Sand) all as specified and directed
3
-
-
M & L PCC type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in benching /haunching manhole including forming channels Complete all as specified.
0.97
-
-
M & L for plain cement concrete 1:2:4 type B-1, using 20 mm graded crushed stone aggregate as in coping & bed block etc including weathering, slightly, rounded or chamfered angles and throating as directed necessary form work complete all as specified and directed.
1.55
-
-
M & L precast cement concrete type B-1, 1:2:4 (20mm graded crushed stone aggregate) as in manhole cover set in CM 1:4 including necessary form work Complete all as specified. Reinforcement shall be measured and paid seperately
0.4
-
-
M & L for cement concrete tiles 25cm x 25cm x 22mm thick, m a c h i n e pressed with grey cement and pigment over cement screed base laid over and including 15 mm thick screed bed in cement mortar 1:4, set and jointed with grey cement slurry mixed with pigment and no pigment in floors/roof, and cut and polished complete all as specified and directed.
120
-
-
M & L for preparation of newly primed surface of steel over 2 coats of synthetic enamel paint over 10 cm width or girth not specified otherwise complete all as specified and directed.
25
-
-
M&L for old size brick work with fly ash bricks straight or curved any radius half brick thick walls, built in cement mortar (1:4) all as specified & directed.
2
-
-
M & L for 19 mm thick plywood, grade BWR, type BB, fixed with screws to timber frame work complete all as specified and directed
25
-
-
S & F in repair 30 mm wide flap when open mild steel, bright finish or electro galvanised Continuous (piano) hinges complete all as specified and directed.
35
-
-
E/M Portion
Taking down carefully existing copper/aluminium point wiring for light, socket or power bell complete with fittings such as switches, sockets, ceiling roses, holders, call bells & making good the disturbed surfaces of wall, matching the colour with existing surface complete all as specified and directed
157
-
-
Taking down MCB with sheet metal enclosure, main switch, DB, etc and making good disturbed surfaces to match with existing surfaces.
12
-
-
Taking down carefully submain wiring/ service connection of any type complete with casing caping / conduit etc complete all as specified and directed.
48
-
-
Material and labour for concealed Point wiring for one light point controlled by one way one switch (using red, black and green colour wires as colour coding) complete with 1.5 Sqmm (nominal cross section area) single core FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through and including PVC conduit 20mm dia (medium duty, ISI marked) with all fittings and all accessories i.e. pipe bend, pipe hook, elbow, junction boxes etc., including Pressed steel powder coated sunken terminal box suitable for modular switch socket (Min 50mm deep and 1.6mm thick sheet, suitable size ) concealed in wall, including inner and outer plates (cover plate) suitable for fixing the modular switch, including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3), including fixing of switches complete all as specified and as directed. (switches shall be measured and paid separately under appropriate item of BOQ as supply only but cost of labour for fixing the same shall deemed to be included in the unit rate. ).
72
-
-
All as per srl item No 121 above, but for ceilling/exhaust fan paint controlled by one switch and regulator complete all as specified and as directed.
24
-
-
All as per srl item No 121 above, but for 3 pin 5 Amp socket outlet on the same board with other switch, sockets complete all as specified and as directed.
16
-
-
All as per srl item No 121 above, but for one 3 pin 5 Amp socket outlet on independent board complete all as specified & directed
20
-
-
All as per srl item No 121 above, but for One bell/buzzer point controlled by one bell push
4
-
-
All as per srl item No 121 above, but for Two way point controlled by two way switch
1
-
-
All as per srl item No 121 above, but wiring with 4 Sqmm multistranded cable and earth wire with copper conductor of size 4 Sq mm for 15 amps power point all as specified
20
-
-
Supply and fix piano type, 230/250 Volts grade on top covers, Modular switch 1 way 6 A, 1 module complete all as specified and as directed.
132
-
-
All as per srl item No 128 above, but for Modular switch 2 way 6 A, 1 module complete all as specified and as directed.
2
-
-
All as per srl item No 128 above, but for Modular switch, one way 16 Amp, 1 Module complete all as specified and as directed.
20
-
-
All as per srl item No 128 above, but for Modular bell push 6 Amp, 1 Module complete all as specified and as directed.
4
-
-
Supply and fix modular Socket outlet 2 in 1, 3 pin multipurpose type 5 Amp, flush type (2 module) complete all as specified and as directed by Engineer-in-charge.
28
-
-
Supply and fix modular Socket outlet 2 in 1, 3 pin multipurpose type 15 Amp, flush type complete all as specified and as directed by Engineer-in-charge.
14
-
-
Supply and fixing LED tube light fitting polycarbonate housing 1 x 20 Watt, appx 4 feet long, with decorative box linear, housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts. (c) Temp operating range : Minus 5°C to Plus 45°C (d) Power factor : Minimum 0.95 (e) THD : Current THD Max10% and voltage THD max 5% (f) IP rating : IP-20. (g) LED Driver of the same make as of the luminaire. (h) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (j) Surge protection minimum 2.5 kV. (k) CCT : Minimum 6000K (l) CRI : Minimum 80 (m) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
42
-
-
Supply and fix in repair Lamp holder, PVC/Polycarbonate type complete with lamp LED 9 Watt for Batten fitting with back plate and all fittings complete all as specified and directed by Engr-In-Charge
12
-
-
Supply and fixing in repair LED Bulkhead fitting 1 x 10 Watt, complete with Standard LED lighting fixture with extruded polycarbonate housing environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to light fitting, complete fitting with all accessories and following specifications complete all as specified and directed by Engineer-in-Charge :-
(a) Lumen system efficacy of luminaire should be minimum 100 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 5°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : 15%. (f) IP rating : IP-65. (g) CCT : Minimum 5400K (h) Polycarbonate housing white coloured (j) LED Driver of the same make as of the luminaire. (k) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (l) Surge protection minimum 2.5 kV. (m) CRI : Minimum 80 (n) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)
7
-
-
S & F mirror light fitting, 01 x 10 watt durable & weather proof industrial lighting solution luminaire with IP-65 protection acomplete all as specified and directed
7
-
-
Supply and fix ceiling rose surface bakelite two to three terminals/plate 5 amps complete all as specified and directed by Engr-in-Charge.
84
-
-
Supply and fix sheet metal enclosure DB single pole and neutral for 240 volts 8 way with 200 Amps rated busbar flush/surface mounting double door complete all as specified and directed
7
-
-
Supply and fix Vertical MCB distribution box 3 phase TPN 4 way double door including MCCB 125 Amp 16 KA as incommer with bus bar rating 200 Amps vertical type dust and vermin proof complete all as specified and as directed by Engineer-in-charge.
1
-
-
Supply and fix MCB single pole 240 Volt 6-32 Amps 10 KA complete all as specified and directed
24
-
-
Supply and fix MCB SPN 240 Volt 63 Amps 10 KA complete all as specified and directed
7
-
-
Supply and fix TP & N 63 Amps, 10 KA complete all as specified and directed
1
-
-
Material and labour for concealed sub main wiring (using colour coding such as red, black, white, green colour or as directed) with 6 Sqmm single core (03 run i.e 2 runs for main phase and neutral, 01 run for continues as earth wire) FRLSH PVC insulated unsheathed multistrand copper conductor cable drawn through and including PVC conduit 25mm dia (medium quality ISI marked), for independent circuit including all fitting arrangement i.e. PVC clamp, rawl plug, screw, PVC junction box, tee, bend etc. and including cutting of chases in wall and making good disturbed surfaces of walls as per original complete all as specified and as directed.
Note :- Three runs of copper conductor cable 6 Sqmm and one run of PVC conduit 25 mm including accessories shall be measured and paid as one unit (one RM length) for payment and extra length of cables required for connection to MCBs/DB shall not be measured and the cost for the same shall deemed to be included in the unit rate.
48
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 15mm dia and water pipe 20mm dia GI Medium grade with funnel and wire mesh, PCC chamber in cement concrete (1:2:4) type B-1 and CI cover with frame all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009. Notes :- (i) 20 mm dia GI pipe Medium grade for watering to be provided with a socket and plug and should be 10 cms above ground level. (ii) Outer edge of earth pit will be 1 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slanting position
2
-
-
Supply and fixing single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB of capacity 20 Amps, 240 volts, AC supply complete all as specified and directed by Engineer-in-Charge.
7
-
-
Supply and fixing in repair LED light fitting as building security lights of 45 Watt Cap 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover, incl street light bracket made out of 25 mm dia GI light grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by Engr-In-Charge
2
-
-
Supply and fix single phase electronic meter tamper proof LCD Display with poly carbonate cover 230 V,10-60 Amp accuracyclass -I 50 Hz, conforming to IS 13779, IP-54 with parameters to show data, time, current reading , load, PF, Voltage and KWH complete all as specified and as directed by Engr-In-Charge.
7
-
-
Supply and fixing ventilating Air fresher Fan of size 250mm sweep, AC single phase 230V 50Hz, 1200RPM, copper winding, made of sturdy Engineering plastic complete with louvers shutter, including provision of cutting of wall for suitable opening as per fan and making good the disturbed surface as per existing, including electric connection with PVC Sheathed copper conductor flexible cable of suitable size drawn in flexible PVC conduit from ceiling rose to fan complete all as specified and as directed by Engineer-in-charge.
Note:- (i) Serial Number as issued by Engr-In-Charge of fan and GE Office name shall also be written on fan with red colour permanent marker, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account.
7
-
-
Supply, installing, commissioning and testing of electric water heater (Geyser, vertical type) storage type ABS body with 3 level safety, capacity 25 litre, BEE approved 5 Star rating, 230 V , single Phase, AC supply, inner tank made out of heavy duty stainless steel sheet with feroglas coated (Designed with single weld line, factory tested with hydraulic pressure as per latest IS code) complete with all accessories such as safety valve, thermostate, NRV, connection piece PVC connection for hot and cold water of suitable length, three core PVC insulated PVC Sheathed copper conductor flexible cable, including 04 no Nut bolt grouting in wall in PCC (1:2:4) using 12.5mm graded stone aggregate for hanging the geyser and making good the disturbed surface complete all as specified and directed by Engr-in-Charge.
7
-
-
Supply and hanging /fixing ceiling fan 1200 mm sweep AC Supply (Input Voltage Range ; 120 to 280V), BLDC type, 5 star rated, BEE and ISI Marked super enamelled, copper winding of 'B' class insulation, single phase, maximum 30W (± 10%), Temperature rise 40 degree maximum without remote with and including capacitive regulator, 03 No blades, down rod including accessories, white colour, total harmonic less than 10%, 5 speed, hanging in position including making connection with flexible cord three core twisted copper conductor of suitable size from ceiling rose to fan complete all as specified.
Note :- (i) Serial Number as issued by Engr-In-Charge of celing fan and GE Office name shall also be written on fan with red colour permanent marker and fixing of regulator on switch board, cost for the same shall deemed to be included in the quoted unit rate nothing extra shall be paid on this account
21
-
-
Supply and fix in repair heavy duty exhaust fan, steel body AC single Phase. 230V of size 300 mm sweep with, blades and fan motor of Cap at least 190 Watt or above , and frame and louvers Complete all as specified and directed by Engr-In-Charge. Old U/S exhaust Fan will be deposited to MES Store yard by the contractor and no schedule of credit will be given tothe contractor on account of this item all as specified and directed by Engr-in-Charge..
7
-
-
Supply and fixing electric calling Bell Ding Dong type, AC 230 Volts single pole including making elctric connection complete all as specified and as directed by Engr-in-charge.
7
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%