Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Building Construction
Eprocure
Opening Date22 Nov 2024
Closing Date15 Jan 2025
Tender Amount₹ 64,00,00,000 
Notes
Download

Costs

Summary

Engineering Procurement And Construction For Provn Of Accn For Eme Ph One Oftwo Phases

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
OTM ACCN FOR EME BN (PH ONE OF TWO PHS) (i) Double storeyed Office & Administrative Accn - 01 Block (ii) Parking shed for Office & Administrative Accn (iii) Single Storeyed Storage Accn (11 Offrs, 38 JCOs, 93 Hav & 297 ORs) (iii) Double Storeyed single Living Accn For 90 ORs (For BHQ & 188 FWC) (iv) Double Storeyed single Living Accn For 84 ORs (185 & 187 FWC) (v) Dinning Hall for 96 ORs , 76 to 100 Pers (For BHQ & 188 FWC) (vi) Dinning Hall for 84 ORs , 76 to 100 Pers (185 & 187 FWC) (vii) Cook House for Kitchen for 90 ORs, 76 to 100 Pers (BHQ & 188 FWC) (viii) Balance portion of Cook House for 90 ORs, 76 to 100 Pers (BHQ & 188 FWC) (ix) Cook House for Kitchen for 84 ORs, 76 to 100 Pers (185 & 187 FWC) (x) Balance portion of Cook House for 84 ORs, 76 to 100 Pers (185 & 187 FWC) (xi) Guard House , For 361 to 600 Pers (For BHQ & 3 x FWC) (xii) Storage Accn for Quarter Guard ( For BHQ & 188 FWC) (xiii) PCC Hard standing ( For 361 to 600 Pers) (xiv) Santry Box - 03 Nos (xv) Pump House - 01 No (xvi) Double Storeyed Office & Administrative Accn (For 185 Fd Wksp Coy) (xvii) Parking shed for Office & Administrative Accn (For 185 Fd Wksp Coy) (xviii) EME Field Repairs Workshop - 01 Block (For 185 Fd Wksp Coy) (xix) Parking shed for EME Field Repairs Workshop (For 185 Fd Wksp Coy)

-

-

-

... More
OTM ACCN FOR EME BN (PH ONE OF TWO PHS) (Contd....) (xx) Battery charging shop (For 185 Fd Wksp Coy) (xxi) R & I Office (For 185 Fd Wksp Coy) (xxii) Hard standing for EME Field Repairs Workshop (185 Fd Wksp Coy) (xxiii) B Vehicle Garrage (For 185 Fd Wksp Coy) (xxiv) B Vehicle Garrage (For 185 Fd Wksp Coy) (xxv) Apron (For B Vehicle Garrage) (xxvi) C Vehicle Garrage (For C Vehicle Garrage) (xxvii) Santry Box - 02 Nos (185 Fd Wksp Coy) (xxviii) Storage for Lubricant & Grease for 11 Vechicles (185 Fd Wksp Coy) (xxix) MT Store for 11 Vechicles (For 185 Fd Wksp Coy) (xxx) Petrol Store - 01 No (185 Fd Wksp Coy) * (xxxi) SARF - 01 No (Small Arm Repair Facility) (xxxii) Alarm Post - 04 Nos (xxxiii) Flag Staff - 02 Nos (for BHQ) (xxxiv) Incinerator - 02 Nos (01 for BHQ & 01 for185 FWC) (xxxv) Fire Point - 12 Nos (06 for BHQ & 06 for185 FWC) (xxxvi) Garbage Bin - 05 Nos (03 for BHQ & 02 for185 FWC) (xxxvii) Static Water Tank, 50000 Ltr capacity Each - 02 Nos (01 for BHQ & 01 for185 FWC) (xxxviii) UG Sump Capacity 5000 Gaallon capacity - 01 No (xxxix) Inspection Pit in main work shop - 01 No (xxxx) Ramp - 01 No (xxxxi) Washing platform

-

-

-

... More
NOTE: Schedule ‘A’ Part II to XVI items which are Prepriced by MES, Bidders shall insert their lump sum amount in the Green coloured field under Col-6 only.

-

-

-

... More
Lump Sum price worked out by the contractor for "SITE CLEARANCE, EXCAVATION & EARTH WORK " as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 112

1

8327121

-

... More
Lump Sum price worked out by the contractor for "ROAD , PATH & CULVERT" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 117

1

31530747

-

... More
Lump Sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 119

1

6418765

-

... More
Lump Sum price worked out by the contractor for "AREA DRAINAGE" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No.120

1

9894570

-

... More
Lump Sum price worked out by the contractor for "EXTERNAL WAER SUPPLY" as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES B/F from Sl page No. 122

1

1372572

-

... More
Lump Sum price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY" as listed in Schedule ‘A’ Part-VII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 132

1

10131256

-

... More
Lump Sum price worked out by the contractor for "COMPOUND WALL, FENCING & GATES" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 136

1

19526666

-

... More
Lump Sum price worked out by the contractor for "GREEN BUILDING NORMS" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 137

1

9188616

-

... More
Lump Sum price worked out by the contractor for "AIR VENTILATION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 138

1

329336

-

... More
Lump Sum price worked out by the contractor for "HOT WATER SUPPY" as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 139

1

2413823

-

... More
Lump Sum price worked out by the contractor for "LIGHTNING PROTECTION" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 140

1

508096

-

... More
Lump Sum price worked out by the contractor for "REFRIGERATOR, AC & AIR COOLING SYSTEM" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 141

1

1425273

-

... More
Lump Sum price worked out by the contractor for "STAND BY DG SET" as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 142

1

53507

-

... More
Lump Sum price worked out by the contractor for "ELECTRICALLY OPERATED CRANE" as listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 143

1

24377

-

... More
Lump Sum price worked out by the contractor for "DEMOLITION & DISMANTLING" as listed in Schedule ‘A’ Part-XVI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES B/F from Sl page No. 146

1

14278181

-

... More
Sch 'A' PART-XVII (MISCELLANEOUS B&R AND E&M WORKS) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under respective schedule.

-

-

-

... More
EXTERNAL WATER SUPPLY / EXTERNAL ELECTRIFICATIONS M & L for Cutting of road/hardstanding not more than 30cm deep 45cm wide for crossing of water pipe line in trenches and making the surface good with PCC(1:2:4) type B-1 using 20 mm graded aggregate complete in all respect as specified and directed

154

-

-

... More
Supply & laying ductile iron, Pressure pipe, Class K-9, 150mm bore dia centrifugally cast (spun) with spigot & socket end ISI marked with IS-8329-2000 with cement mortar lining inside the pipes with outside zinc coating + bitumen coating suitable for push-on-joint (Rubber gasket D joining) in any lenghth complete including all jointing material and rubber gasket laid in trenches / road / pathways /pedal supports etc including making good for disturbed surfaces of road / path ways etc all as specified and directed.

200

-

-

... More
Supply & laying ductile iron, Pressure pipe, Class K-9, 100mm bore dia centrifugally cast (spun) with spigot & socket end ISI marked with IS-8329-2000 with cement mortar lining inside the pipes with outside zinc coating + bitumen coating suitable for push-on-joint (Rubber gasket D joining) in any lenghth complete including all jointing material and rubber gasket laid in trenches / road / pathways /pedal supports etc including making good for disturbed surfaces of road / path ways etc all as specified and directed.

340

-

-

... More
Cutting the existing water supply DI/GI pipe line 200mm bore dia and taking branch connection of 150mm bore dia pipe by inserting Tee complete all as specified and directed. Note:- Rate quoted by the contractor shall be deemed to be including of TEE & other acessories of required size.

1

-

-

... More
M & L heavy duty Ductile iron specials of any size & any type for spigot socketed pipes such as bends (any type, radius and angle), tapers, any type (straight bend, increasing, decreasing or double socket etc) Tee pieces, single branch, “Y” junction, double branch, cross (all sockets or socket and spigot), collars, caps and plugs adopters etc of any size radius and lengh confirming IS specifications, for pipe upto 150mm bore dia complete all as specified and directed.

150

-

-

... More
Supply, install, testing and commissioning for self priming monoblock pumping set of 12.5 HP having minimum discharge not less than 1000/LPM, head range not less than 36 Mtrs with brass impeller, 3 phase, 50 cycle, 415 volts star delta connected, copper wound induction motor, including base frame, PCC foundation, nut, bolts, 3 core copper flat cable of suitable size length from pump set to starter complete all as specified and directed.

2

-

-

... More
Supply and fix 150mm (6'') bore dia Foot Valve conforming to IS-4038 complete all as specified and as directed.

2

-

-

... More
Supply, install and commissioning of factory made Main LT panel outdoor type , self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 3.15mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6mm on PCC 1:2:4 type B-1, platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19mm dia fancy lock, louvers and air vent, gasket consisting of following :- (Near 250KVA TFR)

1

-

-

... More
(a) Copper bus bar 650 Amps Cap 4 wire fixed on insulator not less than 1.0 Mtr long bus bar - 01 Set INCOMING (a) MCCB 4 POLE, 415 Volts, AC, 630 Amps, 50 KA repturing capacity - 01 No. (For incomming main panel) OUTGOING (a) MCCB 4 POLE, 415 Volts, \AC, 400 Amps, 36 KA repturing capacity - 01 No. (For BHQ panel) (b) MCCB 4 POLE, 415 Volts, AC, 125 Amps, 16 KA repturing capacity - 01 No (For JCO Mess panel ,Phase-II) (c) MCCB 4 POLE, 415 Volts, AC, 100 Amps, 16 KA Repturing capacity with thermal magnetic release - 02 Nos (OR LINE Panel & Spare) (d) MCCB 4 pole, 63 Amps, 415 Volt, AC, 16 KA repturing capacity with thermal magnetic release - 01 No. (For Pump House) (e) MCCB 4 pole, 32 Amps, 415 Volt, AC, 16 KA repturing capacity with thermal magnetic release - 02 Nos. (For Spare & Street light) (f) Digital Voltmater 0 - 500 Volt of size 96 x 96mm square with selector switch - 01 No. (g) Indicator lampe (RYB) with holder (Set to three) - 01 Set (h) Ammeter 0 to 630 Amp with selector switch & suitable range of CTs - 01 No

-

-

-

... More
Supply, install and commissioning of factory made Main LT panel outdoor type , self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 3.15mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6mm on PCC 1:2:4 type B-1, platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19mm dia fancy lock, louvers and air vent, gasket consisting of following :- (For BHQ)

1

-

-

... More
(a) Copper bus bar 600 Amps Cap 4 wire fixed on insulator not less than 1.0 Mtr long bus bar - 01 Set INCOMING (a) MCCB 4 POLE, 415 Volts, AC, 400 Amps, 36 KA repturing capacity - 01 No. OUTGOING (a) MCCB 4 POLE, 415 Volts, AC, 160 Amps, 25 KA repturing capacity with thermal magnetic release - 02 Nos. (For Adm Block & Spare) (b) MCCB 4 POLE, 415 Volts, AC, 100 Amps, 16 KA repturing capacity with thermal magnetic release - 02 Nos (For Cook house & Dining Hall) (c) MCCB 4 POLE, 415 Volts, AC, 63 Amps, 16 KA Repturing capacity with thermal magnetic release - 01 No (For Quarter Guard) (d) MCCB 4 pole, 32 Amps, 415 Volt, AC, 16 KA repturing capacity with thermal magnetic release - 05 Nos. (For Guard House, Parking Adm,Street light, Storage & Boom barrier) (f) Digital Voltmater 0 - 500 Volt of size 96 x 96mm square with selector switch - 01 No. (g) Indicator lampe (RYB) with holder (Set to three) - 01 Set (h) Ammeter 0 to 400 Amp with selector switch & suitable range of CTs - 01 No (j) Change over switch for DG 160 Amps - 01 No

-

-

-

... More
Supply, install and commissioning of factory made Main LT panel outdoor type , self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 3.15mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6mm on PCC 1:2:4 type B-1, platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19mm dia fancy lock, louvers and air vent, gasket consisting of following :- (For OR Line)

1

-

-

... More
(a) Aluminium bus bar 150 Amps Cap 4 wire fixed on insulator not less than 1.0 Mtr long bus bar - 01 Set INCOMING (a) MCCB 4 POLE, 415 Volts, AC, 100 Amps, 16 KA repturing capacity - 01 No. OUTGOING (a) MCCB 4 POLE, 415 Volts, AC, 32 Amps, 16 KA repturing capacity with thermal magnetic release - 06 Nos. (For OR Line & Spare) (b) Digital Voltmater 0 - 500 Volt of size 96 x 96mm square with selector switch - 01 No. (c) Indicator lampe (RYB) with holder (Set to three) - 01 Set (d) Ammeter 0 to 100 Amp with selector switch & suitable range of CTs - 01 No

-

-

-

... More
Supply, install and commissioning of factory made Main LT panel outdoor type , self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 3.15mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6mm on PCC 1:2:4 type B-1, platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19mm dia fancy lock, louvers and air vent, gasket consisting of following :- (For Pump House)

1

-

-

... More
(a) Aluminium bus bar 150 Amps Cap 4 wire fixed on insulator not less than 1.0 Mtr long bus bar - 01 Set INCOMING (a) MCCB 4 POLE, 415 Volts, AC, 100 Amps, 16 KA repturing capacity - 01 No. OUTGOING (a) MCCB 4 POLE, 415 Volts, AC, 63 Amps, 16 KA repturing capacity with thermal magnetic release - 03 Nos. (For Pump-02 & Spare-01) (b) Star delta Starter fully automatic suitable for 415 Volt, AC, for 12.5 HP Motor-02 Nos (c) Digital Voltmater 0 - 500 Volt of size 96 x 96mm square with selector switch - 01 No. (d) Indicator lampe (RYB) with holder (Set to three) - 01 Set (e) Ammeter 0 to 150 Amp with selector switch & suitable range of CTs - 01 No

-

-

-

... More
Supply, install and commissioning of factory made Main LT panel outdoor type , self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 3.15mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6mm on PCC 1:2:4 type B-1, platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19mm dia fancy lock, louvers and air vent, gasket consisting of following :- (For 185 Wk)

1

-

-

... More
(a) Copper bus bar 630 Amps Cap 4 wire fixed on insulator not less than 1.0 Mtr long bus bar - 01 Set INCOMING (a) ACB 4 POLE, 415 Volts, 800 Amps with Thermal Magnetic Release (Manual Fixed type) - 01 No OUTGOING (a) MCCB 4 POLE, 415 Volts, AC, 630 Amps, 50 KA repturing capacity - 02 Nos. (For Sub panel) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC, 16 KA rupturing capacity - 02 Nos (For EME Workshop & Spare) (c) MCCB 4 pole, 63 Amps, 415 Volt, AC, 16 KA rupturing capacity with thermal magnetic release - 01 No (For 185 Office) (d) Digital Voltmater 0 - 500 Volt of size 96 x 96mm square with selector switch - 01 No. (d) Indicator lampe (RYB) with holder (Set to three) - 01 Set (e) Ammeter 0 to 630 Amp with selector switch & suitable range of CTs - 01 No

-

-

-

... More
Supply, install and commissioning of factory made Main LT panel outdoor type , self supported, CPRI Approved make, front and rear openable, double door hinged type with locking arrangement and slopping top canopy, suitable protection with dust and vermin proof etc, fabricated out of 3.15mm thick CRCA sheet duly powder coated with 7 tank chemical process, mounted fixed on and included MS angle section 50 x 50 x 6mm on PCC 1:2:4 type B-1, platform 60cm above the ground level and 45cm below the ground level, factory fabricated with front and back openable double door system with and lock openable by keys, having chromium plated 19mm dia fancy lock, louvers and air vent, gasket consisting of following :- (For 185 Wk)

1

-

-

... More
(a) Copper bus bar 630 Amps Cap 4 wire fixed on insulator not less than 1.0 Mtr long bus bar - 01 Set INCOMING (a) MCCB 4 pole, 630 Amps, 415 Volt, AC, 50 KA rupturing capacity - 01 No (For Sub Panel) OUTGOING (a) MCCB 4 POLE, 415 Volts, AC, 160 Amps, 25 KA repturing capacity - 02 Nos. ( For Equipment user (SARF Phosphanting) & Battery Charging) (b) MCCB 4 pole, 63 Amps, 415 Volt, AC, 16 KA rupturing capacity with thermal magnetic release - 01 Nos (For Spare) (c) MCCB 4 pole, 32 Amps, 415 Volt, AC, 16 KA rupturing capacity with thermal magnetic release - 08 No (For Spare , Street light, Veh garage & Parking, SARF paniting, SARF Drying Oven, SARF Compressor, SARF Degreasing of WPN) (d) Digital Voltmater 0 - 500 Volt of size 96 x 96mm square with selector switch - 01 No. (d) Indicator lampe (RYB) with holder (Set to three) - 01 Set (e) Ammeter 0 to 630 Amp with selector switch & suitable range of CTs - 01 No

-

-

-

... More
M & L for Construction of PCC Block Masonary valve chamber of size 900 x 900 x 900mm (Internal dimenssions) with PCC foundation 1:4:8 type D-2 using 40mm graded stone aggregate 150mm thick, 15 mm wide off sets alround over 100mm thick hard core , one brick thick walls built in CM 1:4, 50 mm thick PCC 1:3:6 Type C-1 in benching & coping, finished even and smooth, rendering 10mm thick in CM (1:4) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in Soft / Loose soil 3mm thick MS sheet cover fixed on 40mm x 40mm x 6mm thick angle iron frame with hold fasts 40 x 6 mm embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.

7

-

-

... More
All as per Item No 31 above but size 600 x 600 x 600mm (Internal dimenssions) complete all as specified and directed.

6

-

-

... More
Supply and fixing Distribution panel flush in wall suitable for 415 Volts with Aluminium Bus bar 300 Amps, 4 Nos comprising of following :- (a) MCCB 4 pole 415 Volt, adjustable type , 125 Amps 25 KA-01 No as incomer. Outgoing :- (a) MCCB 4 pole 415 Volt 63 Amps 16 KA- 05 Nos. (b) MCB SPN 230 Volt ,32 Amp - 01 No. (c) Space for Three phase KWH Meter - 5 Nos complete all as specified and directed .

3

-

-

... More
Supply and fixing Distribution panel indoor type flush in wall suitable for 415 Volt with Aluminium Bus bar 200 Amps 4 Nos comprising of following :- (a) MCCB 4 pole 415 Volts, adjustable type , 100 Amps 25 KA-01 No as incomer. Outgoing : - (a) MCCB 4 pole 415 Volt, 63 Amps, 16 KA- 03 Nos (b) MCB SPN 230 Volt, 32 Amps -01 No. (c) Space for Three phase KWH Meter - 03 Nos complete all as specified and directed .

1

-

-

... More
Supply and fixing Distribution panel flush in wall suitable for 415 Volts with Aluminium Bus bar 200 Amps, 4 Nos comprising of following :- (a) MCCB 4 pole 415 Volt, adjustable type , 100 Amps 25 KA-01 No as incomer. Outgoing :- (a) MCCB 4 pole 415 Volt 63 Amps 16 KA- 02 Nos. (b) MCB SPN 230 Volt ,32 Amp - 01 No. (c) Space for Three phase KWH Meter - 2 Nos complete all as specified and directed .

1

-

-

... More
Supply and fixing Distribution panel indoor type flush in wall suitable for 415 Volt with Aluminium Bus bar 200 Amp 4 Nos comprising of following :- (a) MCCB 4 pole 415 Volts, adjustable type , 63 Amps 25 KA-01 No as incomer. Outgoing : - (a) MCCB 4 pole 415 Volt, 63 Amps, 16 KA- 05 Nos. (b) Space for Three phase KWH Meter - 03 Nos complete all as specified and directed .

20

-

-

... More
Supply, install, testing and commissioning of factory made LT panel board (LT Kiosk) outdoor type pedestal mounting, totally enclosed dust and vermin proof, double shutter, front opening including PCC (1:3:6) type C-1 for pedestal of suitable size, made out of CRCA sheet 2.00mm thick and suitable angle iron frame work made of 50 x 6mm MS angle, dust proof busbar chamber, hinged sectional door with locking arrangement copper conductor with PVC insulated cable lugs etc and painted with two coats of synthetic enamel paint over a coat of red oxide primer including IP-54 protection & copper busbar 400 Amps and consisting of following :-

2

-

-

... More
INCOMING: (a) MCCB TPN, 415 Volts, 250 Amps, 25 KA - 01 No. OUTGOING (a) MCCB TPN, 415 Volts, 160 Amps, 25 KA - 02 No (b) MCCB TPN, 415 Volts, 125 Amps, 25 KA - 01 No (c) MCB TPN, 32 Amps, 10 KA - 02 Nos (d) LED indicator lamps (R,Y,B) - 01 Set (e) Digital Ampere and voltmeter digital type with inbuilt selector switch - 01 set.

-

-

-

... More
Supply & Fixing Automatic astronomical functional timer switch single phase 40 Amp rating with inbuilt contactor in enclosure, max load of 08 KW including iron clamps , nuts bolts etc complete all as specified and as directed.

3

-

-

... More
Supply & Fixing Automatic astronomical functional timer switch single phase 20 Amp rating with inbuilt contactor in enclosure, max load of 08 KW including iron clamps , nuts bolts etc complete all as specified and as directed.

1

-

-

... More
M & L for 2.5 Sqmm twin core copper conductor PVC insulated PVC sheathed cable 1100 Volt grade for drawing through poles for making connection to street light fitting provided on poles and upto junction box including thimble etc complete all as specified and as directed.

192

-

-

... More
Supply and fix press moulded SMC junction box of inner demensions 250 x 200 x 105mm, suitable for 3 phase, 4 core cable including 8 way connector, MCB SP 230 Volt, AC 50 Hz 10 KA-01 No weather proof cable connecction 2 x 2.5 Smm conductor from MCB to street light fitting and suitable fittings and fixture complete all as specified and directed.

40

-

-

... More
Supply and fix of path way fitting Bollard light suitable for retrofit LED bulb 8 Watt including fixing accessories i.e Nuts, bolt, washer etc duly fixed at site on PCC 1:2:4, type B-1) foundation type 40cm x 40cm x 40cm complete all as specified and directed.

14

-

-

... More
Supply and fix Gate light in aluminum die cast with modern artistic design and white PC diffuser suitable with LED lamp complete all as specified and directed.

10

-

-

... More
COMPOUND WALL, FENCING & GATES S & F 75mm dia CI wheel as rollers for gates all as specified and as directed.

12

-

-

... More
AIR VENTILATION Supply and fixing commissioning and testing wall / ceiling mounted touch control and motion sensor modular kitchen chimney with auto clean feature cutting edge technology, oil collector, suction 1400+/-100 Cubic Meter per Hours, 230 Volt , size 90cm / 3 Feet, noise less than 58 db suitable for properly removing the smoke, odor, steam and heat from inside of kitchen complete all as specified and directed.

15

-

-

... More
Supply & fixing 300mm sweep, Wall mounted fan, 230 Volt, single phase oscillating complete all as specified and directed.

15

-

-

... More
HOT WATER SUPPLY Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 Litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed.

2

-

-

... More
REFRIGERATOR, AC & AIR COOLING SYSTEM Supply and fix refrigerator, electric driven (single phase) of capacity 195 Litres, BEE 5 Star rated complete all as specified and directed.

2

-

-

... More
Supply and fix refrigerator, electric driven (single phase) of capacity 310 Litres, BEE 5 Star rated complete all as specified and directed.

2

-

-

... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volt with output voltage stabilized at 230 Volt with accuracy of ± 2.5% and of capacity 0.5 KVA complete all as specified and directed.

2

-

-

... More
All as per item No 50 above but 1 KVA.

4

-

-

... More
All as per item No 50 above but 2 KVA.

4

-

-

... More
All as per item No 50 above but 4 KVA.

24

-

-

... More
S & F Desert cooler electric driven single phase having nominal Air flow capacity 5000 Cum per Hrs including front panel with show grill Iron made out of GI sheet 22 SWG complete including front show plate with ON/OFF switch for pump & four speed regulator ISI marked, fan 18" ISI marked , 4 Mfd capacitor, submersible pump ISI marked , wood wool pad (Set of three) heavy duty including interconnecting water and electric witing complete all as specified and directed.

29

-

-

... More
Supply, installation, testing and commissioning of Central Air Cooling Unit Double Skin 10000 CFM Floor Mounted Double Skin (Inner Panel Shall be made out of 0.6mm GI Plain and Outer Panel shall be 0.6mm Precoated GI with 25mm thick Puff Insulation having density of 40 Cum giving 90% efficiency at 500 FPM air velocity across the pads with Tank Made out of 18 Guage Stainless Steel, Cellulose Pad of 200mm thick, pad area 40 Sqft, having Pre filters of aluminium wire mesh and filter frame made of GI sheet. The filter shall have 90% down to 10 Microns filtration efficiency. Cabinet Make – Evapoler Water Recirculation Pump 0.5 HP Circulation, BLOWER DIDW Forward Curved, 800mm Dia Fan (AMCA Certified) Heavy Duty Centrifugal Blower having Forward Curved Impeller, DIDW (Double Inlet double width) Made out of 16 Guage GI enclosed in suitable housing and mounted on EN 8 Shaft duly dynamically and statically balanced. 11 KW/4 Pole, Class F Motor, IE 1 Motor shall be suitable for 415 Volts, 50 Cycles,3 Phase AC Power Supply with IP-55 protection for enclosure complete all as specified and directed..

1

-

-

... More
Supply, installation, testing and commissioning of Central Air Cooling Unit Double Skin 5000 CFM shall be Floor Mounted Double Skin(Inner Panel Shall be made out of 0.6mm GI Plain and Outer Panel shall be 0.6mm Precoated GI with 25mm Thick Puff Insulation having density of 40 Cum giving 90% efficiency at 500 FPM air velocity across the pads with Tank Made out of 18 Guage Stainless Steel, Cellulose Pad of 200mm Thick, pad area 40 Sqft, having Prefilters of aluminium wire mesh and filter frame made of GI sheet. The filter shall have 90% down to 10 Microns filtration efficiency. Cabinet Make – Evapoler Water Recirculation Pump 0.5 HP Circulation, BLOWER DIDW Forward Curved, 800 mm Dia Fan (AMCA Certified) Heavy Duty Centrifugal Blower having Forward Curved Impeller, DIDW (Double Inlet double width) Made out of 16 Guage GI enclosed in suitable housing and mounted on EN 8 Shaft duly dynamically and statically balanced. 11 KW/4 Pole, Class F Motor, IE 1 Motor shall be suitable for 415 Volts, 50 Cycles, 3 Phase AC Power Supply with IP-55 protection for enclosure complete all as specified and directed..

1

-

-

... More
Supply, Installation & testing of Galvanised Sheet of 22 Gauge fabrication of duct with damper and complete nitrile rubber insulation as directed at site with Connectors, GI Flanges, turning vanes, with proper duct sealing etc with RTV duct Sealant, Complete with supports omplete all as specified and directed..

200

-

-

... More
All as per item No 57 but for 20 Gauge FABRICATED Duct

60

-

-

... More
All as per item No 57 but for 18 Gauge FABRICATED Duct

50

-

-

... More
STAND BY DG SET Supply, installation, testing and commissioning of silent DG Set, conforming to IS: 10002-1981 complete with Diesel Engine of suitable BHP & AC Brushless SPDP alternator, conforming to IS : 13364-1992, mounted on a common base frame & coupled through a flexible coupling or close coupled complete with suitable PCC foundation platform, control panel having meters, Remote monitoring unit, sound-proof canopy etc. of not less than 100 KVA (80KW) capacity conforming to the following specifications complete all as specified and directed. Make : Kirloskar , Crompton Greves, Cummins

2

-

-

... More
[a] Engine : 4 cylinder, in-line, 4 stroke, radiator cooled engine, well designed air handling system with dry type, heavy duty, replaceable paper element air cleaner with restriction indicator, air to air aftercooling, optimised turbocharger for increased altitude,Inline fuel pump with class H electronic governing, spin on fuel filter, standard integral set-mounted radiator system, designed and tested for 50°C ambient temperature, full flow spin on lube oil filter, electrical starter motor with soft start engagement feature, ƒƒbattery charging alternator with 1 x 24 or 2 X 12 V DC dry type battery.

-

-

-

... More
[b] Alternator: ƒƒBrushless type, screen protected, revolving field, self-excited alternator, conforming to IS/IEC 60034-1 3-phase reconnectable winding with 12 terminals brought out for connection, dedicated winding specially designed for single operation, impregnation on all wound components for better mechanical strength

-

-

-

... More
[c] Control Panel: Manufactured with 14/16 gauge CRCA sheet and powder coated for weather-proof and long lasting finish.

-

-

-

... More
The control panel consists of the following parts : [i] Controller: Aluminum bus bars with suitable capacity with incoming/outgoing terminals. [ii] Indicating lamps for ‘Load ON’ and ‘Set Running’. [iii] Instrument fuses duly wired and ferruled. [iv] MCCB of suitable rating with overload and short circuit protections

-

-

-

... More
[d] Microprocessor based generator set monitoring and control system including an intuitive operator interface that allows for complete generator set control as well as system metering, fault annunciation, configuration and diagnostics, LED backlit LCD display with tactile feel soft-switches & generator set status LED lamps, remote START-STOP.

-

-

-

... More
ƒ[e] Engine Metering: Oil pressure, engine temperature, starting battery voltage, engine running hours. ƒ [f] AC Alternator Metering: L-L voltage and L-N voltage, current (phase and total), KVA (phase and total) and frequency . [g] ƒEngine Protection: Low lube oil pressure, high/low coolant temperature, battery over/under/weak volts, fail to crank/start, sensor failure, cranking lockout, low fuel level.

-

-

-

... More
[h] AC Alternator Protection: Over/under voltage, over/under frequency, loss of AC sensing. [j] Data Logging : Engine hours, control hours and upto 5 recent fault codes. ƒƒ[k] Configurable glow plug control. [l] ƒƒ24 V DC operation. [n] Mounting Arrangement : ƒƒEngine and alternator are mounted on a common MS fabricated base frame with AVM pads. [o] ƒƒBase frame with integral fuel tank is provided with drain plug, air vent, inlet and outlet connection, level indicator and provision for cleaning.

-

-

-

... More
ELECTRICALLY OPERATED CRANE Design ,Manufacturing, Supply, Erection & Commissioning of indoor type, medium duty class M5, Electrically operated travelling (EOT) overhead crane as per IS : 3177 & 807 (latest version), IS : 2148 of 2004, capable of handling 05 Metric Tonnes (MT) main hoist with centre to centre clear span approximate 15 Metres, double box girder type including floor operated moveable pendant control by means of push buttons independent of crab trolley position, protective panel with down shop lead (DSL), trailing cable complete with all accessories / equipments duly painted with two coat of synthetic enameled paint all as per OEM specifications and as approved by GE. The make of crane shall be as per approved list of make given in P.S or otherwise the manufacturer who installed the crane in MES department with following specification :

1

-

-

... More
EOT cran shall be provided with the following electrically controlled movements type:- (a) Capacity of crane - 05 Ton double box Girder. (b) Clear span - 11 Metres approx each. (c) Bay length - 55 Metres approx. (d) Hook height - 5.5 Metres from the floor level. (e) Longitudinal Travel speed - 10 mpm and micro LT speed 1.0 mpm (f) Cross travel speed - 7 mpm and micro CT speed 0.7mpm (g) Hoisting speed - 3 mpm (h) Micro hoisting speed - 0.3 mpm (j) Control - Pendant control (k) LT wheel track size - As per OEM recommendations (l) CT wheel track size - As per OEM recommendations

-

-

-

... More
NOTE :- (a) Unit rate quoted shall be deemed to include provision of copper wiring of suitable size in rigid metallic conduits with accessories fixed on surfaces from main switch upto electrical control panels and provision of ISMC channel welded alongwith ISMB (gantry girder) and longitudinal travelling rail welded alongwith ISMC. (b) Clear span and bay length specified and shown on building are only indicative. The tenderer shall visit the site and ascertain exact span and bay length before designing/execution. (c) Long travel gantry girder is in the scope of building work & LT wheel and CT wheel track Sqbar has to be provided by the tenderer and cost for the same is to be included in unit rate . (d) Cap channel and rail of both sides included quoted rate it deemed to be included such provision and accessories before execution of work. (e) Dimensions, capacities/sizes of equipments/accessories mentioned on drawing are minimum to be provided. Prior approval of accepting officer shall be obtained for the detailed construction drg and electrical wiring diagram of EOT crane and contractor shall incorporate components wherever required and the rates quoted above shall be deemed to be inclusive of such provisions and all accessories. (f) Longitudinal travel shall be limited to 1.5m away from the wall on both ends. (g) The cranes should be manufactured as per latest IS standards and safety factors.

-

-

-

... More
EOT Crane shall comprise of the following :- (1) Major Technical Specification: Type, Capability and general requirements (a) Type : Double box type girder EOT Crane as per IS : 807 & IS : 3177.(latest version) (b) Crane Operation : Pendant control of reputed make with push button for ON, OFF, UP, DOWN, Forward, Reverse, Left, Right, Siren, Bridge Light & Emergency Stop with option for control selection. Operating voltage 110 Volts. (c) Duty Class : M5 for Indoor Operations. (d) Lifting Capacity : 05 Metric TON (e) Span : 11 metre (f) Height of Lift : 5.5 metre (g) LT Wheel Rail Track Size :Minimum 50x50 Sqmm bar. (h) CT Wheel Rail track size : 50 x 50 Sqmm bar. (j) Bay Length : 55 Metre approx. (k) Clearance between Rail Top to soffit Roof : As per drawing

-

-

-

... More
(2) Maximum Speed (Metre/Min) :- (a) Hoisting : 3 mpm and 0.3 microspeed. (b) 10 mpm and 1 mpm microspeed LT Speed (c) 7 mpm and 0.7 mpm microspeed CT Speed (3) Hook Approach (Maximum possible): (a) Side Clearance: Side clearance to be fixed to suit the Blanking section clearances minimum 250/300mm. (4) Long Travel Motion : LT Motion shall be twin drive type. (5) STRUCTURAL FABRICATION Constructional Details) : (a) Bridge Girder: Shall be of double Girder Box Type construction having Minimum vibrations. (b) End Carriage Fabricated from rolled steel sections/plates as per IS : 2062 (c) Raw Material : Only tested quality steel Fe 410 WB as per IS-2062, IS : 1964 & IS : 808 and certified for quality by reputed inspection authorities, shall be used.

-

-

-

... More
(d) BRIDGE STRUCTURE / CRANE GRIDER: Shall be made out of double box girder type construction having minimum flange width 500 mm and thickness 6.00mm , minimum Web height 1250mm, thickness 8.00mm. Beam should not have deflection more than 1/900 of span on full load as per BS : 466/1960, all as per OEM specifications. (e) Welded Joints (To be followed for Girder fabrication) (i) NO Number of Joints allowed: Max 2 Nos (ii) Welding Electrodes for all Horizontal Welding E-7018 Electrode only should be used. (iii) Welding Electrodes for all Vertical Welding E 7048 Electrode only should be used (f) Welded Joint Testing : All Butt Welded Joint (both compression/tension and flanges/web joints) shall be subjected to 100% X-Ray Testing and X-Ray Film to be produced for MES evaluation and form part of the documentation. (g) Mechnical Joints: Hexagonal Fit Bolts (as per IS 3640-1982) for all joints coming in Main members (h) Heat Treatment & NDT Examination : The Trolleys shall be stress relived, if necessary, by thermal heat-treatment process after welding & NDT. All welding shall be tested by NDT means [MPI, LPI & RT] after stress relieving operation (Govt. approved Test House & certificated). Contractor to furnish the details of facilities for Heart Treatment furnace & NDT Lab at their works. All the welded joints should be NDT tested by Govt. approved Test House & certificate/X-Ray films to be submitted at time of inspection. .

-

-

-

... More
(6) MECHANICAL ELEMENTS : (a) Wheels : Wheels shall be as per IS of forged and made of C-55 Mn 75 Carbon steel, Hardened to BHN 300-350 as per IS /OEM specifications. (b) Wheels Sizes : Outer diameter shall be as under :- (i) Cross Travel (CT) – Contractor to submit the size as per OEM specificaton. (ii) Long Travel (LT) – Contractor to submit the size as per OEM specificaton (c) Number of Wheels : For LT - 04 Nos & CT - 04 Nos. (d) Wheel Assembly : The wheel Assembly of Long Travel (LT) shall be of Live Axle System with L-Type Bearing only. (e) Brake Drum Sizes and minimum braking torques : (i) Main Hoist : As per OEM specifications & design calculation (ii) Cross Travel : As per OEM specifications & design calculation. (iii) Long Travel : AS per OEM specifications & design calculation.

-

-

-

... More
(f) Gear & Gear Boxes Details : Gear Box should be of fabricated type duly stress relived. Pinions made of En-24 and gears of En-18. Gears in all the Stages shall be helical in design and to be of machined, lapped and hardened. Straight and helical spur gearing shall normally be used for all motions. Worm and bevel gears shall not be used. First and high speed reductions shall be through helical gears. All first reduction pinions and also the other pinions if feasible shall be integral with the shafts. All gears shall be of hardened and tempered alloy or carbon steel with machine cut teeth. Gear tooth shall be cut in metric module system. Surface hardering of teeth is not allowed. The Gear /pinion should be hardened to HRC 50-55 and ground. Reduction Gear box ratios in all motions shall be maintained as under : - (i) Main Hoist : As per OEM specifications. (ii) Cross Travel (CT) : As per OEM SPECIFICATIONS . (iii) Long Travel (LT) : As per OEM specifications.

-

-

-

... More
(g) Lubrication : Suitable totally enclosed continuous oil/grease lubrication system shall be provided for gear box for its all rotating parts wherever applicable. (h) Rope Drum : Shall be fabricated type stress relived or seamless pipe. The circumferential weld joints shall be tested by 100% A-Ray quality size i.e. diameter and length shall be as under. :- (j) Main Hoist Rope Drum : As per OEM specificationsNS . (k) Type of Coupling : Coupling should beflexible geared Barrel type. No pin /bush / rubber type coupling to be used. (l) Machining Operation : All mechanical mating surfaces and wheel seating areas are to be machine to the required finish and protected. (m) Hoist Wire Rope Details : Fiber core confirming to IS : 2266. Maintion wire rope dia 16mm, 4 No. of fall & construction. Minimum factors of safety & tensile strength (1960N/Sqmm for wire rope) as per ISO : 4309 :1990 or as per OEM Specification & design. (n) Main Hoist : As per OEM specifications. (o) Buffers (End Stoppers) : Buffers of adequate size be provided. (p) Maintenance Platform : Maintenance / service platform made of 6.0mm thick chequered plate of 750mm width shall be provided & fixed through bolted joints only. A hand railing 1000mm height are to gaurd (Minimum 50mm) shall also be provided. Platform shall have anti-skid grating. (q) Guards : All the moving parts should be duly covered with guards as per safety norm. Proper guard cover / tray to prevent falling of bolts from coupling etc should also be provided, wherever required.

-

-

-

... More
(7) Electricals : (a) Input Power Supply : Shall be 415 ± 10% Volts, 50 ± 3% Hz, 3 Phase, AC. (b) Control Voltage : Shall be 110 Volt AC. (c) Protection : All Panels, Limit-Switches and Motor shall be IP-54 protection. (d) Motor Details : Squirrel Cage Induction Crane duty motors, Totally enclosed, fan cooled, Insulation Class-F & confirming to relevant latest IS:325, and IS-123, S4 duty, 150 starts per hour and 40% CDF. All electric motors shall be provided VVVF drives in all motions, Noted No. of motors, capacity of motor as under. (i) Main Hoist : Min of 10 HP speed less than 1000 rpm or as per OEM specifications. (ii) Cross Travel (CT) : Min of 0.5 HP speed less than 1000 rpm or As per OEM specifications. (iii) Long Travel (LT) : 2 Nos of Min of 0.5 HP speed less than 1000 rpm or as per OEM specifications. (e) Type & Details of Brakes for all Motions : EHT type shall be provided to hold the mechanism in position instantaneously as soon as the power supply is ‘OFF’ either accidentally for all motions. (f) Electric Contactors : All Contactors shall have SIEMENS / L&T/ BCH contactors suitable for Crane operations. Crane duty AC-4 ratings.

-

-

-

... More
(g) Contactor Rating : The rating of all contactor shall be at least 50% higher than the respective electric motor full load current, at the specified duty cycle. (h) Wiring: All the panel wiring should be done by using standard multi core Copper conductor highly flexible, FRLS cables. (j) Down Shop Lead (DSL) : XLPE/PVC insulated copper conductor festoon trailing cables fire resistant and retardant cables as per IS : 694. (k) Trailing Cables Erection : Trailing cables (Extra flexible having copper conductors only) for CT shall be supplied with ready chain type (E-chain) with tongue and groove type (Make - Igus / Gortrac) and erected by contractor. LT shall be tailing cables, Fastoon type, copper conductor. (l) IIlumination : 03 Nos totally enclosed 100 w LED Lamps and fitting shall be provided under the bridge. (m) Limits Switches : Hoist shall be provided with gravity type (Over Hoisting and Over lowering). Shunt adjustable type limit switches. Limit switches shall be provided for both CT and LT motions. Two way lever type for CT and LT for both directions. (n) Pendent control : Pendent should be MS Sheet fabricated having push buttons for each motion e.g. Bridge light, Siren/bell On and Off switches and stay put type emergency stop switch push button. Pendent shall be independent moveable type. (o) ANTI-COLLISION DEVICE: As per OEM specifications

-

-

-

... More
(8) Painting Instructions:. (a) Surface Cleaning : Girder to be shot blasted or chemically treated for surface cleaning, after completion of all operations but prior to painting. (b) Painting : One coat of Red Oxide Primer and 48 hours of compulsory curing after painting.. (c) The crane should be thoroughly cleaned and final painting with two coat of synthetic enameled paints (Colour- Golden Yellow) and intermitted curing of 16 hours. Final touching will be done after erection and testing.

-

-

-

... More
(9) MAKES OF BOUGHT OUT ITEMS (BOI) : Makes shall be as per the list given below. (a) Hoist Hooks : Herman Mohtta / Hercules / Silpa Udyog / Smriti Forgings / Karachiwala (b) Wire Ropes : Usha Martin / Fort William / GARWARE. (c) Electric Motors : GE/ Bharat Bijlee / Siemens / KEC / ABB / Crompton / Alstom /marathan. (d) Thruster Brake Unit : ElectroMag / Speed-O-Control / Omega. (e) Limit Switches (Gravity type) : Siemens / EMM/BCH / SOC / SKF. (f) Contactors : Siemens / L&T / GE / BCH (g) Over Load /Time Relay : Siemens / L&T /GE / BCH. (h) HRC Fuses : Siemens / L&T / GE

-

-

-

... More
(j) Switch fuse unit : Siemens / L&T / GE / BCH . (k) MCB / MCCB : Siemens / L&T / GE. (l) PUSH Buttons : Siemens / L&T / BCH. (m) Couplings : As per OEM. (n) Bearings : SKF / FAG / NTN / Ina only. (o) Cables : LAPP / Schiess Kabel / CCl / Fort Gloster / Grandely / Finolex / KEI ISI marked /polycab / IGUS . (p) Bridge light fittings : Bajaj / Philips / Wipro / Sudhir / Balaji / Flexpro . (q) Transformer : Logistat / Pactil / Any reputed make. (r) Control Panel : As per OEM specification. (s) Documents / Details for submission : The following documents/ details shall be submitted to MES reference for approval of accepting officer / checking within 30 days from the date PO placement, prior to taking up the manufacturing of the crane.

-

-

-

... More
(10) Drawing / Documents : For approval from accepting officer. (a) GA Drawing of the Crane (for approval) - Contractor to submit. (b) GA Drawing of Hoist /Trolley(for approval) - Contractor to submit . (c) Calculation of Bridge Girder- ISMB / ISMC - Contractor to submit. (d) Calculation for Selection of Electric Motors, Gears, Brakes, Couplings, Wheels, Wire Rope etc.: Contractor to submit. (e) Design calculation for Bridge Girder, Crab etc.: Contractor to submit. (f) Calculation of Bridge Girder- ISMB / ISMC - Contractor to submit. (g) Wiring Diagram with Logic Circuits and Bill of Material (for Approval) - Contractor to submit. (11) INSPECTION : (a) Verification of Test certificate for Raw materials used for Girders, end carriages, Hoist, Gear box casings etc - Contractor to comply. (b) Verification of X-Ray report of butt joints coming in the girders and Random testing on the welds by Physical examination - Contractor to comply. (c) Inspection of Bridges and End carriages with Wheel assembly and Alignment checking - Contractor to comply. (d) Verification of Span and diagonal dimensions, Checking of Wheel Alignment, Mechanical Assemblies and Total Alignment - Contractor to comply. (e) Free running of the CT and Hoist mechanisms - Contractor to comply. (f) Check of Crane span and diagonal -10 kg pull should be applied while checking - Contractor to comply

-

-

-

... More
(g) Measurement of CAMBER in the bridges - Contractor to comply. (h) Full/ Rated Load Test and deflection test - Contractor to comply. (j) 125% Rated-LOAD Lifting ability check - Contractor to comply . (12) CRANE ERECTION & COMMISSIONING (a) Unloading & Erection : Unloading the consignment at site will be carried out by the Contractor. Contractor shall shift the all crane material to site and erect the crane at MES site. Necessary tools and equipments required for erection shall be brought by the Contractor. (b) Crane Commissioning : Prove out for the Crane’s Capacity and Smooth Functioning of the Crane (at site) shall be the responsibility of the Contractor. Final Load testing as per ISS at 125% of rated load shall be conducted at site by the representative of Accepting Officer in the presence of Engineer-in-Charge. Load shall be arranged by contractor from location at site shown by Engineer-in-charge. (c) All safety equipments like safety boot,saftey belt, helmet, gloves, loader, googles etc required for erection personnel shall be brought bt contractor-contractor to comply .

-

-

-

... More
(13) TOOLS & SPARES : (i) Tool box with standard tools shall be supplied with the crane. (ii) Recommended spares for two years normal working of equipment shall be furnished. Details of bearings, oil seals used should be supplied with the crane. (14) O & M Manuals : (a) Five (05) sets, of Erection, Operation and Maintenance Manual along with two sets of CDs, containing the following technical drawings and details shall be submitted. All copies shall be hard bound in high quality leather folders, encased in decent individual boxes. (b) Contractor is required to measure all necessary dimensions i.e. Span, Head room, Clearances between rail centre to existing coloumn and rail size etc, at site before starting of the crane design/ manufacturing.

-

-

-

... More
(15) ADDITIONAL NOTES : (a) The details refered to above will be considered as our offer. (b) Any ‘T’ bid details even after all confirmation are found missing or left out, the details and specifications given in the tender documents shall be followed.

-

-

-

... More
DEMOLITION & DISMANTLING Taking down steel window and removing from site complete all as specified and as directed.

1171.55

-

-

... More
Dismantling of cast iron pipe 75mm bore dia & taking out of trenches, if required all as specified and as directed.

12.22

-

-

... More
Dismantling & taking out of trenches old UG cable , any type, any size all as specified and as directed.

305

-

-

... More
Dismantling & taking down old street light fittings any type all as specified and as directed.

16

-

-

... More
Dismantling & taking down old switch fuse unit / MCCB DB / MCB DB any size all as specified and as directed.

10

-

-

... More
Taking up or down steel tubing and connections of any size including fittings & fixtures such as bends, elbow union etc & removing from site complete all as specified and as directed.

180

-

-

... More
Taking down old Air conditioning from existing position of connected work & depositing to store yard of AGE E/M all as specified and directed .

2

-

-

... More
Taking down old water cooler from existing position of connected work & depositing to store yard of AGE E/M all as specified and directed .

4

-

-

... More
Taking down old Desert cooler from existing position of connected work & depositing to store yard of AGE E/M all as specified and directed .

15

-

-

... More
Taking down old OH conductor with connected items from existing position & depositing to store yard of AGE E/M all as specified and directed .

16

-

-

... More
Taking up or down old GI/DI/CI Pipe 100mm bore dia with all fittings & connected items from existing position and rerouting the same with provision of new fittings complete all as specified and directed .

300

-

-

... More
BOOM BARRIER M & L Automatic hydraulic type Boom Barrier for Gate No Front gate and rear gate complete all as specified and as directed.

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.