Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Electrical and Electronics
Coronavirus COVID 19
Electrical Works
Eprocure
Opening Date1 Oct 2018
Closing Date27 Oct 2018
Tender Amount₹ 21,58,550 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 60,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_MES_216825_1Bid Award Id
ViewTender No
GE (A) SOG - 25/18-19Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
S&F GI wire including stretching on HT/ LT poles as contineous earth wire or for guarding and cradles including binding as required complete all as specified and directed by Engineer-in-Charge.
Note: -(i) For payment purpose, weight of galvanised wire shall only be considered. Clamps, eye hooks where provided shall be measured and paid for separately
0.5
-
-
... More
S&F in replacement shackle type insulators, vitreous porcelain white, brown or green for working pressure 1100 volts grade of 100 mm height and 115 mm dia including galvanized mild steel straps of 31mm x 5mm size,14mm dia insulator bolts, washers and nuts complete all as specified and directed by Engineer-in-Charge.
20
-
-
... More
S&F in replacement pin type insulator of size 100mm height, 65 mm dia porcelain, vitreous white, brown or green insulator suitable for 1100 volts grade including one galvanized mild steel spindle, two GI washer and one GI nut complete all as specified and directed by Engineer-in-Charge.
10
-
-
... More
S&F in replacement cross arms, bracings, stiffeners, supports, clamps and back plates fabricated from structural steel confirming to Fe-290 (Gde E-165) including nuts, bolts, washers, welding, binding cold or hot, drilling holes for bolts, in any shape or size complete all as specified and directed by Engr-in-Charge.
Note :Exposed steel surface shall be treated with two coats of synthetic enamel paint over a coat of red oxide primer and unexposed surface of steel sections shall be applied one coat of red oxide primer.
1.5
-
-
... More
S&F in replacement stay assembly complete with accessories as shown in electrical plate No 1 using stay rod 20 mm dia x 1800mm long, stay bow 14mm dia and stay plate 30 cm x 30 cm x 6 mm including stay wire 8 SWG x 7 strands, loop type insulator with over all dimensions 90x140mm and clearence of hole 25.5mm, stay clamps and painting to exposed surfaces of mild steel work with two coats of aluminum paint over a coat of red oxide primer, complete all as specified and directed by Engineer-in-Charge.
Note : Excavation, earthwork and PCC in foundation shall be measured and paid seperately under respective items of BOQ.
4
-
-
... More
M&L for painting on steel tubular poles 9 metre long including attachments (cross arms, clamps GI pipes etc) complete with one coat of aluminium paint after preparation of steel surfaces and black & yellow strips 30cm each upto 1.5 metre height from top of PCC foundation block or PCC coping including numbering of poles with synthetic enamel paint (Black) in 80mm high letters over 150mmx230mm yellow base complete all as specified and directed by Engineer-in-charge.
345
-
-
... More
M&L for preparation of old painted surfaces of PCC pole and applying two coats of synthetic enamel paint in black and yellow colour in alternate strips of 30 cm each upto 1.50 metre height from top of PCC coping and applying one coat of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc. and marking pole number with black synthetic enamel paint in 80mm high letters, over yellow synthetic enamel paint base of size 20cm x 20cm including applying two coats of white wash to coping of poles all as specified and directed by Engineer-in-Charge.
Note :- Pole number shall be marked with black enamel paint over a base of size 20cm x 20cm prepared with two coats of yellow enamel paint on pole surfaces.
425
-
-
... More
Disconnecting over head conductors and insulators any Nos. on existing damaged pre-stressed concrete LT poles, dismantling MS work such as cross arms/clamps/hooks etc., stay and street light (where exists), excavating and taking out damaged pole making good hole to receive new pole and S&F in same position new pre-stressed concrete pole 09 meter long of cross section 102mm x 172mm at the top and 102mm x 279mm at bottom, class 10, complying with requirements of IS-1678-1978, re-fixing the MS work cross arms/clamps/hooks etc. and insulators retrieved from dismantling and re-jointing the conductors & including applying one coat of synthetic enamel paint in alternate black and yellow strips 30 cm each upto 1.5 metre height from PCC coping and applying one coat of aluminum paint over cross arms, brackets, bracings, clamps, hooks etc. and marking pole number complete all as specified and as directed by Engineer-in-charge.
Notes: - (i) PCC in foundation & coping shall be measured and paid for separately.
8
-
-
... More
Disconnecting and re-stretching ACSR conductor of any size and re-fixing with and including new 2mm dia aluminum binding wire complete all as specified.
Note :- (i) The rate quoted by the contractor shall deemed to be included for cutting / trimming of tree branches touching / approaching the LT over lines upto 3 metre width on each side with hacksaw / axe to clear the LT line including disposal of trimmed branches 100 metre away inside the cantonment area & cleaning site as directed by Engineer-in-charge.
(ii) Length of each conductor shall be measured as one length.
550
-
-
... More
M & L for PCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of poles etc including weathering, slightly rounded or chamfered angle and throating, necessary form work and fair finishing all exposed faces of concrete without using extra cement complete all as specified and directed by Engineer-in-charge
0.5
-
-
... More
M & L for PCC (1:3:6) typeC-2 using 40mm graded stone aggregate as in foundation for stays & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge
4.5
-
-
... More
M & L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation for poles, struts & mass concrete including necessary form work and fair finishing to exposed surfaces complete all as specified and directed by Engineer-in-charge
3.3
-
-
... More
M&L for earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick packed layer of charcoal dust and common salt, connected to galvanized iron strip 32mm x 6mm thick as earth lead by means of bolts, nuts and washers of galvanised iron or steel and thimbles and other end of the earth strip connected to earthing test point/equipment and protected by galvanised iron pipe light grade 40mm dia upto earthing test point/equipment fixed with required number of mild steel clamp made out of 25mm x 3mm flat iron and perforated water pipe 20mm dia GI medium grade of length 2.25 metre and top with socket & plug and bottom connected to earth plate by slit and two bolts/nuts/washers, PCC chamber in cement concrete (1:2:4) type B-1 and 40mmthick pre-cast RCC (1:2:4) type B-0 cover with 40mm x 40mm x 3mm MS angle iron frame, excavation & earth work complete all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 including taking down old earthing complete all as specified and directed by Engineer-in-charge.
Notes :- (i) GI strip upto earth test point/equipment is included in this item. (ii) Outer edge of earth pit shall be 1.5 metre away from the outer edge of PCC chamber. (iii) Minimum weight of reinforcement for earth pit cover shall be 1 kg .
20
-
-
... More
Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade of cross sectional area 185 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc complete all as specified and directed by Engineer-in-charge.
Notes :- (i) Excavation, earth work, sand cushioning, cable protection and GI pipe shall be measured & paid for separately under respective items of BOQ (ii) Road cutting / floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall deemed to be inclusive of the above provisions.
300
-
-
... More
All as per item No 17 above but cable of cross sectional area 120 sq mm 3.5 core
150
-
-
... More
All as per item No 17 above but cable of cross sectional area 95 sq mm 3.5 core
200
-
-
... More
All as per item No 17 above but cable of cross sectional area 50 sq mm 3.5 core
250
-
-
... More
All as per item No 17 above but cable of cross sectional area 35 sq mm 3.5 core
950
-
-
... More
All as per item No 17 above but cable of cross sectional area 25 sq mm 3.5 core
1250
-
-
... More
All as per item No 17 above but cable of cross sectional area 16 sq mm 4 core
550
-
-
... More
All as per item No 17 above but cable of cross sectional area 16 sq mm 2 core
250
-
-
... More
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations of poles, struts, stays etc. or laying underground cable and water supply / sewage pipe line etc. in soft / loose soil & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
810
-
-
... More
All as per serial item No. 25 here-in-above but depth exc 1.5 mtr & not exc 3mtr
0.5
-
-
... More
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed by Engineer-in-Charge
464
-
-
... More
Removal of excavated soil/ material to a distance not exc 50 metre and depositing where directed at a level n. exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
346
-
-
... More
M&L for dry sand (Tibba sand) and punning for cushioning to underground cable complete all as specified and directed by Engineer-in-charge.
Note: - For payment purpose thickness after punning shall be measured.
243
-
-
... More
M & L for brick protection with old size sub class 'B' bricks laid flat, abutting each other with gap between adjacent bricks not exc. 10mm, length of bricks across the route of underground cable complete all as specified and directed by Engineer-in-Charge.
2700
-
-
... More
Supplying, jointing and testing in replacement heat shrinkable type straight through jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
5
-
-
... More
All as per item No 31 above but suitable for cable of size 70 sqmm to 150 sqmm.
4
-
-
... More
All as per item No 31 above but suitable for cable of size 185 sqmm to 300 sqmm.
6
-
-
... More
Supplying, jointing and testing in replacement heat shrinkable type outdoor, end termination jointing kit, suitable for cable of size 25 to 50 Sqmm, 3.5 core aluminium conductor 1100 Volts including making connections complete all as specified and directed by Engineer-in-Charge.
15
-
-
... More
All as per item No 34 above but suitable for cable of size 70 sqmm to 120 sqmm.
5
-
-
... More
All as per item No 34 above but suitable for cable of size 150 sqmm to 185 sqmm.
5
-
-
... More
Cutting/ trimming of tree branches not exc 10cm girth touching/approaching the LT / HT overhead lines upto 3 metre width on each side with hacksaw/axe to clear the LT / HT line including disposal of trimmed branches 100 Metre away inside the cantonment area & clearing site complete all as specified and directed by Engineer-in-Charge. (Approximate length of span 40 to 50 metre)
Note:-The contractor shall be responsible to maintain this item of work till the date of completion work. Nothing shall extra be paid on this account.
60
-
-
... More
S&F in replacement Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches / under road / drains, fixed to poles / walls with required numbers of clamps made out of 25x3mm flat iron, bolts, nuts and washers for protection of LT electric cable complete all as specified and as directed by Engineer-in-charge.
Notes :- (i) Excavation & earthwork shall be measured & paid for separately under respective items of BOQ
26
-
-
... More
All as per serial item No. 38 here-in-before but 80mm bore.
24
-
-
... More
All as per serial item No. 38 here-in-before but 50mm bore.
48
-
-
... More
M&L for preparation of existing painted surfaces of Panel Board / Feeder Pillar box (indoor / outdoor type), area not exceeding 10 square metre each and applying one coat of synthetic enamel paint after preparation of surfaces on external and internal surfaces of approved tint by using spray machine inclusive of writing SM / MES No / name of feeders etc. (not exceeding of height 5 cm each) including welding of broken panel door, tightening electric connection of switch gears and cleaning of vegetation all around the panels up to one meter from all sides complete all as specified and as directed by Engineer-in-charge.
5
-
-
... More
M&L for fixing MS sheet 2mm thick to existing LT panels / feeder pillar box including necessary straightening / correcting the distorted parts, cuttings, welding / riveting, drilling bend to shape as required, welding of hinges, sliding door bolts, locking arrangement, nut, bolts, washers etc and appying two coats of synthetic enamedled paint over a coat of red oxide primer to match with the existing surfaces comlepte including butt hinges sliding door bolts and taping , thimbling disconnecting all incoming and outgoing complete all as specified and as directed by Engineer-in-charge.
10
-
-
... More
S&F in replacement MCCB 4 Pole 100 Amps, thermal magnetic release having, breaking capacity 25 KA, 415 Volt in the existing feeder pillar box including any addition / alteration to the panel to accommodate the new MCCB & making connections with 25x3 mm copper strip as required from main bus bars, making necessary welding work, metal work for fixing base plate etc and connections complete all as specified and as directed by Engineer-in-Charge. Make : Legrand Cat Part No. DPX³ 160 420055 or equivalent in Havells / L & T / Schneider
4
-
-
... More
All as per item No. 43 here-in-before but MCCB 4 Pole, 160 Amps rating, breaking capacity 25 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 160 420057 or equivalent in Havells / L & T / Schneider
5
-
-
... More
All as per item No. 43 here-in-before but MCCB 4 Pole, 250 Amps rating, breaking capacity 25 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 250 420219 or equivalent in Havells / L & T / Schneider
4
-
-
... More
All as per item No. 43 here-in-before but MCCB 4 Pole, 400 Amps rating, breaking capacity 36 KA, 415 Volt Make : Legrand Cat Part No. DPX³ 630 422007 or equivalent in Havells / L & T / Schneider
5
-
-
... More
Suppyling, installing, testing and commissioning of factory made outdoor type LT cubical panel board suitable for operation on 415 volts, 3 phase, 4 wire 50Hz supply system inlcluding bus bar chamber in centre ( vertically) and cable alley either side, outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the following mentioned fittings and inner shell shall be made out of 2mm thick CRCA sheet duly powder coated & compartmentalized for each control gear including front openable single door with half nob type locking, inlcuding provision for taking out incoming and outgoing cables duly marked with reveted letter plated of appropriate size for each feeder / block cable, danger board, detachable plate at bottom for cable entry etc. with bottom frame made out of angle iron 40mm x 40mm x 5mm and 600mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with and including following accesories :-
Incoming (a) 400 Amps aluminium bus bar for phases and 200 Amps for Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set
(b) MCCB 250 Amps, 36 KA, 3 Pole, thermal Magnetic release type including shunt trip coil - 01 No Make - Legrand Cat Part No DPX³ 250 420239 or equivalent in Havells / L & T / Schneider
Outgoing (a) MCCB 100 Amps, 16 KA, 3 Pole, thermal Magnetic release type including shunt trip coil - 07 No Make - Legrand Cat Part No DPX³ 160 420005 or equivalent in Havells / L & T / Schneider
(b) Digital multi function meter (voltmeter 0-500V, Ammeter 0-400A, frequency meter, power factor meter. - 01 Set (c) Indicating lamp 240 volts LED type - 01 Set (set of three)
(d) CTs 250/5 Amps - 01 set (set of three)
(e) Internal all links & control cable and indicators - set of three
2
-
-
... More
All as per item No 47 above but comprising of following accessories
Incoming (a) 350 Amps aluminium bus bar for phases and 200 Amps for Neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty epoxy insulators in seprate compartment and internally prewired - 01 Set
(b) MCCB 200 Amps, 36 KA, 3 Pole, thermal Magnetic release type including shunt trip coil - 01 No Make - Legrand Cat Part No DPX³ 250 420238 or equivalent in Havells / L&T / Schneider
Outgoing
(a) MCCB 63 Amps, 16 KA, 3 Pole, thermal Magnetic release type including shunt trip coil - 07 No Make - Legrand Cat Part No DPX³ 160, 420003 or equivalent in Havells / L&T / Schneider
(b) Digital multi function meter (voltmeter 0-500V, Ammeter 0-400A, frequency meter, power factor meter) - 1 Set
(c) CTs 250/5 Amps - 01 Set (set of three)
(d) Indicating lamp 240 volts LED type - 01 Set (set of three)
(e) All links with copper conductor or solid aluminium bus bar of adequate capacity and inspection lamp
2
-
-
... More
Suppyling, installing, testing and commissioning factory made indoor type bus bar chamber mounted on wall of suitable size for operation on 415 volts, 3 phase, 4 wire, 50 Hz, outer shell made out of 2mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with double door fix with hinges and locking arrangements etc suitables to accomodate the 400 Amps aluminium bus bar fixed Horizontally in staggred manner minimum length 450mm, 3 phases and neutral duly insulated with heat shrinkable PVC sleeves and colour coded mounted on heavy duty DMC insulators including provision for taking out incoming and outgoing cables detachable plate at bottom for cable entry and making six Nos hole in each bus bar including making arrangement for fixing bus bar chamber on wall complete all as specified and as directed by Engineer-in-charge.
6
-
-
... More
S&F in replacement LT Line polypropylene composite phase separator, moulded or bolted type, overall length 360mm, width 25mm, thickness 12mm, suitable for 2-lines wire complete all as specified and as directed by Engineer-in-charge.
96
-
-
... More
S&F in replacement LT Line polypropylene composite phase separator, moulded or bolted type, overall length 640mm, width 25mm, thickness 12mm, suitable for 3-lines wire complete all as specified and as directed by Engineer-in-charge.
57
-
-
... More
S&F in replacement MCB, four Pole 63 Amps, having breaking capacity 10 KA, 'C' Curve complete all as specified and directed by Engineer-in-Charge.
Make :- Legrand Cat Part No 408702 or equivalent in L & T / Schneider / Havells
83
-
-
... More
S&F in replacement Single phase automatic automatic street light switch suitable for 5 KW load complete with two numbers Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with one number two pole power contractors 40 Amps (Type - MU40-2P, Cs90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 01 No, outgoing MCBs single pole - 01 No of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is 30 Lux and for switching OFF 10 Lux. The sensor (one service & one stand by) should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a pole / wall mountable enclosure made of Rust proof, Electric shock proof, termite proof and FR grade confirming to IP66 complete all as specified and directed by Engineer in charge.
Make :- Swadeep
2
-
-
... More
S&F in replacement three phase automatic street light switch suitable for 5 KW load complete with two numbers Infrared sensor based NATURE SWITCH for automatic switching of street / security lights with three number two pole power contractors 40 Amps (Type - MU40-2P, CS90119) with coil voltage 220 / 240 V and incoming MCBs single pole - 03 Nos, outgoing MCBs single pole - 03 Nos of rating 32 Amps & circuit wiring with single core multi stranded of size 10 Sqmm. Lighting switch operation should be based on natural light lux level. Required illuminance level for switching ON is 30 Lux and for switching OFF 10 Lux. The sensor should also have part night operation facility for 4,5,6,........11 & 12 hours. The sensor along with suitable power contactor (S), Incoming -outgoing MCB's should be enclosed in a pole / wall mountable enclosure made of Rust proof, Electric shock proof, termite proof and FR grade confirming to IP66 complete all as specified and directed by Engineer in charge.
Make :- Swadeep
2
-
-
... More
Suppyling, installing, testing and commissioning in replacement factory made outdoor type chamber of suitable size to accomodate the existing Air Circuit Breaker of capacity 630 Amps, 415 Volt, 3 phase having appx size 55cm X 60cm X 50cm outer shell shall be made out of 3.15mm thick CRCA sheet duly powder coated coated siemens gray shade and completely weather, vermin & dust proof, adequate air ventilation at sides & back, outer door shall be provided with hinges and locking arrangements etc including provision for taking incoming and outgoing cables detachable plate at bottom for cable entry including double compression type cable gland and bottom frame made out of angle iron 40mm x 40mm x 5mm and 750mm long 4 legs duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer on exposed surfaces grouted in PCC 1:2:4 type B1 using 20mm graded stone aggregate blocks of size 30cm x 30cm x 60cm and 100mm thick PCC (1:2:4) type B1 floor over and including 100mm thick sub base of brick hardcore extended 100mm on all sides below panel body with suitale nuts, bolts, washers etc complete all as specified and as directed by Engineer-in-charge.
3
-
-
... More
S&F in replacement power contactor two pole of capacity 40 Amps, coil voltage 220/ 240 volts, type MU-2P, wide band coil complete all as specified and directed by Engineer-in-Charge.
Make:- L&T cat part No CS90119 or equivalent in Havells / GE / Legrand / Schneider
------------------------------------------------------------------------------------------------------------------------------------
Note :- A sum of Rs. 191380/- will be deducted on account of credit for dismantled/ demolished / taken down material. Please refer details on Srl Page No. 22 & 23 (Schedule of Credit) of Tender documents.
6
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements