Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Eprocure
Opening Date9 Dec 2024
Closing Date30 Dec 2024
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per items No. 1 here in before but of capacity 100 ltrs per day complete all as specified and directed by Engineer-in-charge.

200

-

-

... More
S&F in repair make up tank capacity 10 Ltr made out of stainless steel all as per existing sample & shape, including connection nipple for incoming and delivery as per existing complete for solar water heater all as specified and directed by Engr-in-Charge.

10

-

-

... More
S & F in repair of heating element suitable for solar water heating system of capacity 2 KW ISI marked as per existing shape all as directed by Engr-in-Charge.

100

-

-

... More
S & F in repair of heating element suitable for solar water heating system of capacity 3 KW ISI marked as per existing shape all as directed by Engr-in-Charge.

60

-

-

... More
S & F in repair of thermostat of capacity 0 to 80 degree suitable for upto 3 KW heating element of capacity all as directed by Engr-in-Charge.

120

-

-

... More
Supply and fix as in replacement, solar panel toughened glass having thickness 3.2 mm all as per the existing model of system complete gasket made out of fine rubber to make system air tight, dust and water proof all as specified and directed by Engineer-in-charge.

150

-

-

... More
S&F in repair hot water storage tank of food grade stainless steel 100 ltr capacity with heat exchanger having thermic fluid / Anti - freeze solution complete suitable ETC (Evacuated Tube Collector) solar water heating system including opening the outer body removing the glass wool, fixing the tank and flling the glass wool as before, re-installing the outer body, connecting the inlet and outlet connection, air vent, replacing the inlet/ outlet nipple complete all as specified and directed by Engineer-in-charge.

9

-

-

... More
S&F in repair hot water storage tank of food grade stainless steel 200 ltr capacity with heat exchanger having thermic fluid / Anti - freeze solution complete suitable FPC (Flat Plate Collector) solar water heating system including opening the outer body removing the glass wool, fixing the tank and flling the glass wool as before, re-installing the outer body, connecting the inlet and outlet connection, air vent, replacing the inlet/ outlet nipple complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
S&F in repair hot water storage tank of food grade stainless steel 500 ltr capacity with heat exchanger having thermic fluid / Anti - freeze solution complete suitable FPC (Flat Plate Collector) solar water heating system including opening the outer body removing the glass wool, fixing the tank and flling the glass wool as before, re-installing the outer body, connecting the inlet and outlet connection, air vent, replacing the inlet/ outlet nipple complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
Supply and fix as in replacement, solar evacuated glass tube including water seal gasket (top and bottom) suitable for 100/200/300 Ltrs Solar water heater complete all as per existing size and shape as specified and directed by Engineer-in-charge.

400

-

-

... More
S&F in repair of rotational moulded polyethylene water storage tank 500 Ltrs capacity (Cylindrical vertical with closed top) hoisted and fixed in position including fly nut, tank nipples with check nuts and washers complete and making connections with existing water supply line including dismantling old PVC storage tank, all as specified.

10

-

-

... More
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 2.5 Sqmm stranded copper conductor drawn in existing conduit with and including PVC FRLS insulated 2.5 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.

200

-

-

... More
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4.0 Sqmm stranded copper conductor drawn in existing conduit with and including PVC FRLS insulated 4.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.

100

-

-

... More
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 4.0 Sqmm stranded copper conductor drawn in PVC conduit fixed on walls/ceilings with and including PVC FRLS insulated 4.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.

100

-

-

... More
M & L as in repairs submain wiring with two single core cables PVC FRLS insulated unsheathed 6.0 Sqmm stranded copper conductor drawn in PVC conduit fixed on walls/ceiling with and including PVC FRLS insulated 6.0 Sqmm stranded copper conductor cable as earth continuity conductor and connecting complete all as specified and directed by Engineer - in – Charge. Note : PVC cables two single core and one single core of sizes as mentioned will considered as one unit.

100

-

-

... More
S & F in repair of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 20mm dia.

20

-

-

... More
S & F in repair of Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe 15mm dia.

10

-

-

... More
Supply and fix, in repair of Gun - metal globe or gate valve with iron wheel head, screwed both ends for iron pipes and for unions and fixing including taking down existing unserviceable valves complete all as specified and directed for the size 20mm dia

10

-

-

... More
Supply and fix, in repair of Gun - metal globe or gate valve of size 15mm dia with iron wheel head, screwed both ends for iron pipes and for unions and fixing complete all as specified and directed for the size 15mm dia

58

-

-

... More
Fabrication of stand for hot water storage tank /FPC (Flat Plate Collector) panel stand by using 60mmx60mmx6mm angle iron, bracings, supports, fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint including dismantling old rusted stand all as directed by Engr-in-Charge

10

-

-

... More
M &L for cement concrete PCC 1:2:4 type B1 (using 20 mm aggregrate) as coping complete all as specified and directed

5

-

-

... More
Supply and Fixing in repair of 20mm dia GI pipe, medium grade ISI mark with all fittings laid in trenches/ wall complete all as specified and directed

300

-

-

... More
Supply and fixing in repair of 15mm dia GI pipe, medium grade ISI mark with all fittings laid in trenches/wall complete all as specified and directed

30

-

-

... More
Supply and lay in repair of 25 mm dia GI pipe, medium grade ISI mark with all fittings laid in trenches/wall complete all as specified and directed.

50

-

-

... More
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 450 mm long complete all as specified.

50

-

-

... More
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 600 mm long complete all as specified.

50

-

-

... More
S&F in replacement PVC connection 15 mm bore size with PTMT nuts,rubber washers etc complete of length 900 mm long complete all as specified.

10

-

-

... More
Taking down geysers of any make & size from existing position of any height for repair, maintenance and refixing the same after neccesary repair complete all as directed. Notes (i) The defective parts to be replaced and shall be measured and paid separately under relevant item of Sch . (ii) Cost of minor items i.e. Screws, nut & bolts, indicator lamps, mounting bolt & nut etc shall be deemed to be included in the above item.

50

-

-

... More
S&F in replacement heating element 2.0 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.

30

-

-

... More
S&F in replacement heating element 1.5 KW, ISI marked with gasket, nuts, bolts suitable for the existing triangular/round shape/make of the geyser under repair complete all as specified.

50

-

-

... More
S&F in replacement thermostat (ISI marked) suitable for existing make of the geyser under repair of cap 50/25 Ltrs complete all as specified.

50

-

-

... More
S&F in replacement geyser safety valve (pressure release valve) for the existing make & capacity of geyser complete all as specified.

10

-

-

... More
M&L for painting of geyser of any cap 25/50 Ltr with 2 coats of synthetic enamelled paint after scraping the existing old painted surface complete all as directed.

10

-

-

... More
S&F in replacement syphon assembly suitable for 25 ltr geyser

30

-

-

... More
S&F in replacement syphon assembly suitable for 50 ltr geyser

20

-

-

... More
S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 25 ltr geyser vertical type including rubber gasket complete all as specified and directed.

20

-

-

... More
S&F in replacement inner tank made up of stainless steel conforming to IS suitable for 50 ltr geyser vertical type including rubber gasket complete all as specified and directed.

20

-

-

... More
S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 25 ltr geyser complete all as specified and directed.

20

-

-

... More
S&F in replacement outer body made up of steel duly painted including base cover and indicator assembly suitable for 50 ltr geyser complete all as specified and directed.

20

-

-

... More
S&F in replacement Glass wool filling in between inner tank and outer body of geyser of any make and type complete all as specified and directed.

15

-

-

... More
S&F in replacement 3 core PVC insulated PVC sheathed flexible copper wire multistranded of size 2.5 sqmm complete all as specified and directed.

30

-

-

... More
S&F in replacement plug top 3 pin, 15 Amp rating ISI Marked Make : Anchor or equivalent

30

-

-

... More
Supply, Installation, Testing, Commissioning and replacement of 2 Zone Fire Alarm Control Panel as per IS-15908:2011 standard, Certified for Safety Standard IEC 62368-1:2018, Up to 600 Cable Connectivity per zone, 20 Detectors per zone plus 5 MCPs, LCD Display, Stand-by Battery Backup with built in charging, Fire/Fault status LED indication, SMPS System, Key Pad for Panel Operation, System Indication, Stand-by status Indication, Low battery warning with tone, Zone wise Isolation facility with loop voltage cut off complete all as specified and directed. Make:Honeywell,SIMPLEX and Autronica.

4

-

-

... More
Supply, Installation, Testing, Commissioning and replacement of 4 Zone Fire Alarm Control Panel as per IS-15908:2011 standard, Certified for Safety Standard IEC 62368-1:2018, Up to 600 Cable Connectivity per zone, 20 Detectors per zone plus 5 MCPs, LCD Display, Stand-by Battery Backup with built in charging, Fire/Fault status LED indication, SMPS System, Key Pad for Panel Operation, System Indication, Stand-by status Indication, Low battery warning with tone, Zone wise Isolation facility with loop voltage cut off complete all as specified and directed. Make:Honeywell,SIMPLEX and Autronica.

6

-

-

... More
Supply, Installation, Testing, Commissioning and replacement of 6 Zone Fire Alarm Control Panel as per IS-15908:2011 standard, Certified for Safety Standard IEC 62368-1:2018, Up to 600 Cable Connectivity per zone, 20 Detectors per zone plus 5 MCPs, LCD Display, Stand-by Battery Backup with built in charging, Fire/Fault status LED indication, SMPS System, Key Pad for Panel Operation, System Indication, Stand-by status Indication, Low battery warning with tone, Zone wise Isolation facility with loop voltage cut off complete all as specified and directed. Make:Honeywell,SIMPLEX and Autronica.

8

-

-

... More
Supply, Installation, Testing, Commissioning and replacement of 8 Zone Fire Alarm Control Panel as per IS-15908:2011 standard, Certified for Safety Standard IEC 62368-1:2018, Up to 600 Cable Connectivity per zone, 20 Detectors per zone plus 5 MCPs, LCD Display, Stand-by Battery Backup with built in charging, Fire/Fault status LED indication, SMPS System, Key Pad for Panel Operation, System Indication, Stand-by status Indication, Low battery warning with tone, Zone wise Isolation facility with loop voltage cut off complete all as specified and directed. Make:Honeywell,SIMPLEX and Autronica.

4

-

-

... More
Supply, Installation, Testing, Commissioning and replacement of Optical Smoke Sensor with Base LEDs for 360° Visibility, Advanced Detection and Communication Protocol, Sleek Low-profile Housing design, Regular 100 mm. base, IP 42, Smoke Sensitivity (1.96±0.76)% per ft., Air Velocity 0-400 fpm. EN54 Certified, 8 to 30 V DC Operating, Operating Temperature -30° to +70°C, including 12 V relay version complete all as speicied and directed. Make:Honeywell,SIMPLEX and Autronica.

600

-

-

... More
Supply, Installation, Testing, Commissioning and replacement of Conventional Sounder, wall & ceiling mount, with back box, 24 V DC operation, Peizo electric type, Fire engine siren tone complete all as specified and directed. Make:Honeywell,SIMPLEX and Autronica.

20

-

-

... More
Supply, Installation, Testing, Commissioning and replacement of Response Indicator complete all as specified and direceted. Make:Honeywell,SIMPLEX and Autronica.

60

-

-

... More
Supply, Installation, Testing, Commissioning and replacement of Manual Call Point, alarm status indicated by LED, 24 V DC operation, NC & NO output complete all as specified and directed.Make:Honeywell,SIMPLEX and Autronica.

60

-

-

... More
Supply, Laying & Terminations of 2 Core 1.5 sq. mm. PVC cable complete all as specified and directed. Make:- Finolex, havells, Polycab, RR cable

1500

-

-

... More
Material and labour for repairing/servicing the Electric induction motor and centrifugal pump coupled type by carefully disconnecting the connection cables and earthings, disconnection of electric, water supply connections both side (suction and discharge side) and fixing of dummy plates as per site requirement. Removing side covers, servicing, greasing, changing of gland packing, gaskets, defective minor parts and re-assembling, testing, preparing the surfaces of the motor and pump for painting with two coats of synthetic enamel paint and commissioning the motor and pump of capacity 60 HP to the satisfaction of Engr-in-Charge. Note: (i) The rent of T&P for handling the pump motor assembly during dismantling and refixing is deemed to be included in the rate quoted by contatcor. (iii) Major spare parts of motor will be measured and paid separately under following respective items.

1

-

-

... More
Material and labour for repairing/servicing the Electric induction motor and centrifugal pump coupled type by carefully disconnecting the connection cables and earthings, disconnection of electric, water supply connections both side (suction and discharge side) and fixing of dummy plates as per site requirement. Removing side covers, servicing, greasing, changing of gland packing, gaskets, defective minor parts and re-assembling, testing, preparing the surfaces of the motor and pump for painting with two coats of synthetic enamel paint and commissioning the motor and pump of capacity 10 HP to the satisfaction of Engr-in-Charge. Note: (i) The rent of T&P for handling the pump motor assembly during dismantling and refixing is deemed to be included in the rate quoted by contatcor. (iii) Major spare parts of motor will be measured and paid separately under following respective items.

1

-

-

... More
Supply and replacing of following under mentioned worn out U/s parts of centrifugal 60 HP pumping set :-

-

-

-

... More
Gland bush

1

-

-

... More
Ball bearing

1

-

-

... More
Roller bearing

1

-

-

... More
Supply and replacing of following under mentioned worn out U/s parts of centrifugal 10 HP pumping set :-

-

-

-

... More
Gland bush

1

-

-

... More
Ball bearing

1

-

-

... More
Roller bearing

1

-

-

... More
M&L for maintenance and servicing to 3 cylinder, 51.5 KW Diesel engine for 'B' check as per the recommendations of manufacturer (OEM) including renewal of necessary recommended filters, engine oil, 'O' rings etc., complete all as directed by Engineer-in-charge.

1

-

-

... More
S & F in replacement of fuel feed pump of DG set engine 51.5 KW as per exiting make, model and capacity complete all as per existing make ,model and capacity complete all as directed by Enginner-in- charge.

1

-

-

... More
S& F in replacement of NRV of DG set engine as per existing make, model complete all as directed by Engineer-In-Charge.

1

-

-

... More
S & F in replacement of inlet and outlet fuel pipe from fuel tank to engine as per existing size and make complete all as directed by Engineer-In-charge.

1

-

-

... More
Cleaning of U/G sump of capacity 20000 Gln first with plain water and then with the bleaching powder 20 Kg after cleaning making white wash of the inner surface with the lime complete all as directed by the Engineer-in-Charge. Note:- The job shall be completed within 8 hrs to avoid any interruption in the system

1

-

-

... More
Material and labour for preparing of old steel surfaces and applying two coat of synthetic enamel paint of existing existing colour for fire fighting equipment DD Pump, valves, pipes, hose box, hose drum etc with two coats of synthetic enamel paint of existing colour in ATC Fire Fighting Pump System. Note: Prior Approval of colour sample of paint should be taken from GE before applying.

1

-

-

... More
S&F of rotational moulded polyethylene water storage tanks of capacity 2000 Ltrs (cylindrical vertical with closed top) hoisted and fixed in position all as specified including dismantling the unsv tank and necessary connections inlet and outlet should be done all as directed by Engr-in-Charge.

2

-

-

... More
Servicing single head fire hydrant/ any type fire brigade of any size taking out, checking out for any obstructions to the functioning of hydrant, servicing, replacement of damaged parts/accessories, like bolts & nuts, rubber gaskets etc complete all as directed.

10

-

-

... More
Servicing of sluice/ non return valve of any size upto 200mm dia taking out, checking out for any obstructions to the functioning of sluice/ NRV, servicing, replacement of damaged parts/accessories, like bolts & nuts, rubber gaskets, gland packing etc and refixing the same as before complete all as directed.

5

-

-

... More
S&F in repair gun metal threaded foot valve of size 100 mm dia with suitable strainer all as specified.

2

-

-

... More
S&F in repair gun metal threaded foot valve of size 50 mm dia with suitable strainer all as specified.

1

-

-

... More
Supply and fixing in repair of 50mm dia GI pipe, heavy grade ISI mark with all fittings laid in trenches/along the wall complete all as specified and directed

12

-

-

... More
All as per item No 70 but for 100 mm dia

12

-

-

... More
S&F in repair Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet with lock and keys suitable to accommodate two canvas fire hose of dia 63mm dia, ength 15 meter painted fire red out side and brilliant white inside yard for indoor application

3

-

-

... More
S&F in repair Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet with lock and keys suitable to accommodate two canvas fire hose of dia 63mm dia, length 15 meter painted fire red out side and brilliant white inside yard suitable for outdoor application

4

-

-

... More
S& F in repair pressure guage with 4'' dial 0-21 Kgs all as specified

2

-

-

... More
S&F in repair pressure switch universal type

1

-

-

... More
S&F in repair canvas hose of dia 63mm dia and length 15 meter of PIL dura type conforming to IS 636/1988 Type-A with proper exterior and interior coatings

5

-

-

... More
S&F in repair canvas hose of dia 63mm dia and length 30 meter of PIL dura type conforming to IS 636/1988 Type-A with proper exterior and interior coatings

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.