Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date24 Jan 2025
Closing Date13 Feb 2025
Tender Amount₹ 30,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only pump shaft as per existing

1

-

-

... More
Supply only gun metal impeller with neck key

1

-

-

... More
Supply only terminal box including connectors of copper, plate of motor.

1

-

-

... More
Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc. complete all as specified and directed.

2

-

-

... More
M & L for transporataion & dismanteling of centrifugal pump set of Cap 5 to 10 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after repairs as directed by Engineer-in-charge Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant items of BOQ.

3

-

-

... More
Supply only bush with oiling and gresing as required.

1

-

-

... More
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA

2

-

-

... More
Supply only gun metal impeller with neck key

1

-

-

... More
Shaft sleeve bronze as per existing

1

-

-

... More
supply only shaft metallic coupling with key.

2

-

-

... More
M & L for transporattaion & dismanteling of centerifugal pump set of Cap 12.5 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :- Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item

2

-

-

... More
supply only bush with oiling and gresing as required.

1

-

-

... More
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA

1

-

-

... More
Supply only stainless steel pumpshaft as per existing

1

-

-

... More
Supply only gun metal impeller with neck key

1

-

-

... More
Shaft sleeve bronze as per existing

1

-

-

... More
M & L for transporattaion & dismanteling of centerifugal pump set of Cap 20 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers , Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ.

2

-

-

... More
supply only bush with oiling and gresing as required.

2

-

-

... More
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA

2

-

-

... More
Supply only damaged star rubber coupling as per existing

2

-

-

... More
Supply only gun metal impeller

1

-

-

... More
Shaft sleeve bronze as per existing

1

-

-

... More
supply only shaft metallic coupling with key.

1

-

-

... More
Supply only stainless steel shaft as per existing

1

-

-

... More
M & L for transporataion & dismanteling of centerifugal pump set of Cap 30 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers , Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ.

2

-

-

... More
supply only bush with oiling and gresing as required.

2

-

-

... More
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA

2

-

-

... More
Supply only damaged star rubber coupling as per existing

2

-

-

... More
Supply only gun metal impeller

1

-

-

... More
Shaft sleeve bronze as per existing

1

-

-

... More
supply only shaft metallic coupling with key.

1

-

-

... More
Supply only stainless steel shaft as per existing

1

-

-

... More
M & L for transporataion & dismanteling of centerifugal pump set of Cap 40 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ.

3

-

-

... More
supply only bush with oiling and gresing as required.

3

-

-

... More
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA

6

-

-

... More
Supply only damaged star rubber coupling as per existing

6

-

-

... More
Supply only gun metal impeller as per existing.

1

-

-

... More
Shaft sleeve bronze as per existing

2

-

-

... More
supply only shaft metallic coupling with key as per existing.

2

-

-

... More
Supply only stainless steel shaft as per existing

1

-

-

... More
M & L for transporataion & dismanteling of centrifugal pump set of Cap 50 HP 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling, alignment of pumps and motors in proper manner and testing including replacing worn out nuts, bolts, washers, Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ.

1

-

-

... More
supply only bush with oiling and gresing as required.

1

-

-

... More
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA

1

-

-

... More
Supply only, stainless steel pumpshaft as per existing

1

-

-

... More
Supply only damaged star rubber coupling as per existing

1

-

-

... More
Supply only gun metal impeller

1

-

-

... More
Shaft sleeve bronze as per existing

2

-

-

... More
M&L for transporataion & dismantling of existing defective induction motor of the Pumpset capacity 50 HP, 03 phase, 415 Volt sizes from the foundation, disconnecting the electric connection, coupling joint and transporting to workshop for cutting down and removing existing burnt copper windings, clenining of slots and rewinding with supper enameled copper conductor complete including varnishing, drying, ovening, overhauling, greesing, necessary lathe work and replacement of bearing and fixing in the original position, making neccessary electric connection and coupling connection and testing of induction motor complete all as specified and as directed by Eng in charge

1

-

-

... More
,---ditto--- all as per Item No 8 but Induction motor of Pumpset cap 40 HP, 03 phase, 415 Volt complete.

2

-

-

... More
,---ditto--- all as per Item No 8 but Induction motor of Pumpset cap 30 HP, 03 phase, 415 Volt complete.

2

-

-

... More
,---ditto--- all as per Item No 8 but Induction motor of Pumpset cap 20 HP, 03 phase, 415 Volt complete.

2

-

-

... More
,---ditto--- all as per Item No 8 but Induction motor of Pumpset cap 12.5 HP, 03 phase, 415 Volt complete.

2

-

-

... More
,---ditto--- all as per Item No 8 but Induction motor of Pumpset cap 5 to 10 HP, 03 phase, 415 Volt complete.

2

-

-

... More
M & L for transporataion & lifting out submersible pump set of Capacity 7.5 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ.

3

-

-

... More
Supply only stainless steel pumpshaft as per existing

2

-

-

... More
Supply only gun metal impeller with neck key and distance bush.

2

-

-

... More
Supply only Shaft bush as per existing

3

-

-

... More
Supply only thrust bearing with plate of pump as per existing

3

-

-

... More
Supply only rubber gasket 3mm thick of any size as per existing

10

-

-

... More
Cutting of burnt winding and rewinding the stator with PVC insulated copper wire as per existing size and class of insulation including insulation paper, sleeves, thimbles etc. complete all as specified and directed.

2

-

-

... More
M & L for transporattaion & taking out / lifting out of submersible pump set of Capacity 10 HP, 3 phase, 415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under relevant item of BOQ.

6

-

-

... More
Supply only stainless steel pumpshaft as per existing

3

-

-

... More
Supply only gun metal impeller with neck key and distance bush

4

-

-

... More
Supply only Shaft bush.

6

-

-

... More
Supply only thrust bearing with plate of pump as per existing

5

-

-

... More
Supply only rubber gasket 3mm thick of any size as per existing

20

-

-

... More
Cutting of burnt winding and rewinding the stator with PVC insulated copper wire as per existing size and class of insulation including insulation paper, sleeves, thimbles etc. complete all as specified and directed.

5

-

-

... More
M & L for transporataion & taking out / lifting out of submersible pump set of Capacity 12.5 HP, 3 phase,415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item

7

-

-

... More
Supply only stainless steel pumpshaft.

3

-

-

... More
Supply only gun metal impeller with neck key and distance bush.

4

-

-

... More
Supply only Shaft bush.

6

-

-

... More
Supply only thrust bearing with plate of pump

5

-

-

... More
Supply only rubber gasket 3mm thick of any size as per existing complete all as specified and directed.

30

-

-

... More
Cutting of burnt winding and rewinding the stator with PVC insulated copper wire as per existing size and class of insulation including insulation paper, sleeves, thimbles etc.

6

-

-

... More
M & L for transporattaion & taking out / lifting out of submersible pump set of Capacity 15-17.5 HP, 3 phase,415 volts, 50Hz, AC supply along with column pipe of any size from the bore well after disconnecting electric connection, dismantling of pump and motor for repairing/ replacing defective parts as ordered, oiling, greasing as required and re-assembling and testing including replacing worn out nuts, bolts, washers complete and lowering the same after repairing and making electrical and delivery pipe connections complete all as specified and directed. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item

4

-

-

... More
Supply only, stainless steel pumpshaft.

3

-

-

... More
Supply only, gun metal impeller with neck key and distance bush.

4

-

-

... More
Supply only Shaft bush.

6

-

-

... More
Supply only thrust bearing with plate of pump

5

-

-

... More
Supply only rubber gasket 3mm thick of any size

30

-

-

... More
Cutting of burnt winding and rewinding the stator with PVC insulated copper wire as per existing size and class of insulation including insulation paper, sleeves, thimbles etc. complete all as specified and directed

3

-

-

... More
M & L for transporattaion & dismanteling of mono block, fountain pump set openwell any type of Cap 2/3 HP, 1 or 3 phase, 415 volts, 50Hz, AC supply after disconnecting electric connection, dismanteling of pump for repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers,Lathe machine work complete and lowering the same and reconnecting to pipe line and electric connection after following repairs as directed by Engineer-in-charge :- Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item

3

-

-

... More
supply only bush with oiling and gresing as required.

3

-

-

... More
Supply only ball bearing as per existing. Make:- NBC/SKF/TATA

4

-

-

... More
Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc. complete all as specified and directed.

2

-

-

... More
S&F in repair DOL starter for 10 HP suitable for 3 phase, 415 volts AC supply, relay range 13 to 21 Amp, power contactor 32 amp, combine V/A meter, voltmeter selector switch, ON/OFF indication, IP 54 protection, Single phase preventor complete all as specified and directed.

2

-

-

... More
S&F in repair of fully automatic star delta starter suitable for 20 HP Capacity, 3 phase 415 V AC supply, relay range 20A to 32 A , power contactor 32A, combine V/A meter, voltmeter selector switch, single phase protection, IP 54 protection, ON/ OFF indication complete all as specified and directed.

4

-

-

... More
S&F in repair of fully automatic star delta starter 30 HP, relay range 30 to 50 Amp, 3 phase 415 V AC supply, conactor 50A, combine V/A meter, voltmeter selector switch, single phase protection, IP 54 protection, ON/ OFF indication complete all as specified and directed.

1

-

-

... More
S&F in repair of fully automatic star delta starter for 50 HP 3 phase 415 V AC supply, relay range 45 A to 75 A, contactor 75A, combine V/A meter, voltmeter selector switch, single phase protection, IP 54 protection, ON/ OFF indication complete all as specified and directed.

1

-

-

... More
S&F in replacement of soft starter of size 294.6 x 156.4 x 192.2 mm of capacity up to 20 HP centrifugal pump in exising panel and taking down unsv complete all as specified and directed.. (Make:- L&T Cat No. EMX3-0043B or equivalent in ABB/ Siemen as approved by GE.)

1

-

-

... More
S&F in replacement of of soft starter of size 294.6 x 156.4 x 192.2 mm of capacity up to 40 HP centrifugal pump in exising panel and taking down unsv complete all as specified and directed. (Make:- L&T Cat No. EMX3-0053B or equivalent in ABB/ Siemen/ Schneider as approved by GE.)

1

-

-

... More
S&F in replacement of soft starter of size 294.6 x 156.4 x 222.7 mm of capacity up to 50 HP centrifugal pump in exising panel and taking down unsv complete all as specified and directed. (Make:- L&T Cat No. EMX3-0076B or equivalent in ABB/ Siemen as approved by GE. )

1

-

-

... More
S&F in replacement copper cable multistranded conductor unarmoured 25 Sqmm single core 1100 v grade PVC insulated sheathed along with proper lugs complete all as specified and directed.

10

-

-

... More
S&F in repair MCCB TPN (4 pole) 63 Amp , 415 volts, 50 Hz 16 KA including taking down unsv complete all as specified and directed.

5

-

-

... More
S&F in repair MCCB TPN (4 pole) 100 Amp , 415 volts, 50 Hz 16 KA including taking down unsv complete all as specified and directed.

3

-

-

... More
S&F in repair MCCB TPN (4 pole) 200 Amp , 415 volts, 50 Hz 35 KA including taking down unsv complete all as specified and directed.

1

-

-

... More
S&F in repair MCCB TPN (4 pole) 250 Amp , 415 volts, 50 Hz 36 KA including taking down unsv complete all as specified and directed.

1

-

-

... More
S&F in repair MCCB TPN (4 pole) 400 Amp , 415 volts, 50 Hz 36 KA including taking down unsv complete all as specified and directed.

1

-

-

... More
Supply & fix straight through heat shrinkable cable jointing kit suitable for 1.1 KV, 3.5 core XLPE / PVC armoured aluminium conductor cable of 16 Sqmm to 50 Sqmm size grade cable complete with jointing material and accessories including necessary earth work complete all as specified and directed.

6

-

-

... More
,---ditto--- all as per srl item No 32 above but 70Sqmm to 120 Sqmm size complete.

6

-

-

... More
S&F in replacement of power contactor of capacity 20 Amp, 4 pole 415 Volt, as per existing complete all as specified and directed.

4

-

-

... More
S&F in replacement of power contactor of capacity upto 32 Amp, 4 pole 415 Volt , as per existing complete all as specified and directed.

3

-

-

... More
S&F in replacement of power contactor of capacity 40 Amp, 4 pole 415 Volt, as per existing complete all as specified and directed.

2

-

-

... More
S&F in repair for electronic star delta 160 -500 V for 3-30 sec timer as per existing complete all as specified and directed.

3

-

-

... More
Supply & fix in replacement thermal overload Relay 3 phase 415 volt 50 Hz, thermal release range 1.5-3 Amp complete all as specified and directed.

2

-

-

... More
Supply & fix in replacement thermal overload Relay 3 phase 415 volt 50 Hz, thermal release range 8. - 13.5 Amp complete all as specified and directed.

2

-

-

... More
Supply & fix in replacement thermal overload Relay 3 phase 415 volt 50 Hz, thermal release range 13.5-20 Amp complete all as specified and directed.

2

-

-

... More
Supply & fix in replacement thermal overload Relay 3 phase 415 volt 50 Hz, thermal release range 22-30 Amp complete all as specified and directed.

2

-

-

... More
Supply & fix in replacement thermal overload Relay 3 phase 415 volt 50 Hz, thermal release range 30-50 Amp complete all as specified and directed.

2

-

-

... More
Supply & fix in repair for single phase preventor 380 to 415 Volt as per existing complete all as specified and directed.

3

-

-

... More
Supply and fix in replacement Pressure switch Universal type complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of motor terminal block 60 Amps 3 way complete all as specified and directed.

4

-

-

... More
Supply and fix in replacement of motor terminal block 100 Amps 3 way complete all as specified and directed.

4

-

-

... More
Supply & fix in repair for ampere meter with CT,s of range 0-60 amps as per existing complete all as specified and directed.

3

-

-

... More
Supply & fix in repair for voltmeter with PT,s of range 0-500 volts as per existing complete all as specified and directed.

5

-

-

... More
S&F in replacement of old U/S gland packing with new to the Pump set of any sizes/capacity complete with neoprene rubber gasket, jointing material and incl nuts/bolts/washer of suitable size etc complete all as specified and directed.

30

-

-

... More
Supply and fix in repair MS nuts, bolts with washer of any size as per site condition complete all as specified and directed.

20

-

-

... More
S&F in repair 80mm bore size GI heavy grade column pipe (ISI marked), both side flanged and welded (Each of 3 m length) including taking out old corroded column pipe both side flanged complete all as specified and directed.

4

-

-

... More
,---ditto--- all as per srl item No 51 above but 65 mm bore pipe complete.

30

-

-

... More
,---ditto--- all as per srl item No 41 above but 50 mm bore pipe complete.

30

-

-

... More
S&F heat shrinkable cable jointing kit suitable for submersible cable of 1100 volts grade, 4/6/10 sqmm 3 core, complete with jointing material and accessoriescomplete all as specified and directed.

20

-

-

... More
Supply only submersible copper cable PVC insulated over all sheethed flat ISI marked, 1100 volts grade of 6 sqmm 3 core complete all as specified and directed.

550

-

-

... More
Supply only submersible copper cable PVC insulated over all sheethed flat ISI marked, 1100 volts grade of 10 sqmm 3 core complete all as specified and directed.

230

-

-

... More
Supply only submersible copper cable PVC insulated over all sheethed flat ISI marked, 1100 volts grade of 4 sqmm 3 core complete all as specified and directed.

100

-

-

... More
Labour only for checking the serviceability of the different spares/ component/ parts of the starter and motor pump set/ panel/ phase sequential of any capacity at site complete all as directed by Engr-in-charge

55

-

-

... More
M & L for Dismanteling of pressure pump set of cap upto 0.5 HP, single phase, 230 volts, 50Hz, AC supply after disconnecting electric connection, repairing/ replacing defective parts as ordered, re-assembling and testing including replacing worn out nuts, bolts, washers, bearing etc complete and electric connection after following repairs as directed by Engineer-in-charge. Note : - (i) The spare part required for replacement shall be measured & paid for separately as supply only under item

8

-

-

... More
M & L for transportation of 0.5 HP motor winding for Cutting of burnt winding and rewinding the stator with supper enamelled copper wire of suitable size and class of insulation including insulation paper, sleeves, thimbles etc. complete all as specified and directed.

5

-

-

... More
Supply and fix in replacement of changover switch 125 Amp, 415 volts, 4 pole off load with sheet enclouser suitable complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of changover switch 160 Amp , 415 volts, 4 pole off load with sheet enclouser suitable complete all as specified and directed.

1

-

-

... More
Supply and fix in replacement of changover switch 200 Amp , 415 volts, 4 pole off load without sheet enclouser suitable for existing panel complete all as specified and directed.

1

-

-

... More
Taking out old unsv 80mm bore steel tubing and connections from walls and ceilings, trenches, under floor or road complete all as specified and directed.

122

-

-

... More
,---ditto--- all as per srl item No 64 above but 100 mm bore pipe complete.

20

-

-

... More
M&L for 80mm bore galvanised steel tubes "medium grade " (ISI marked) with all fitting (ISI marked) and fixed complete to walls and ceilings or laid in floors/trenches and under road complete all as specified and directed.

122

-

-

... More
,---ditto--- all as per srl item No 66 above but 100 mm bore pipe complete.

20

-

-

... More
S&F in repair pressure pump of capacity 0.5 HP single phase 230 volts 50 HZ AC supply including all electric connection to the nearest pont, testing and commissioning Complete as directed and specified by Engineer-in-charge. Make :- KSB or equivelent as approved by GE

3

-

-

... More
S & F in replacement of CI foot valve of size 150 mm with gun metal working parts, ISI marked with all fittings all as specified and directed by EIC

4

-

-

... More
,---ditto--- all as per item No 69 above but 80 mm size complete all as specified and directed.

4

-

-

... More
,---ditto--- all as per item No 69 above but 50 mm size complete all as specified and directed.

2

-

-

... More
,---ditto--- all as per item No 69 above but 40 mm size complete all as specified and directed.

2

-

-

... More
Providing area cleaning/sweeping of preimises water supply installation (Ph House) including cutting out green vegetation, roots, bushes, Tree branches ,picking polothineand other unwanted material from the installation area and maintaining the ground surrounding the installation and removing the same out side the defence area as directed by Engr in charge. The approx area of installation kept clean all as under. (1) PH haldi ghati -6500 Sqm (2) Sub area booster pump house - 5200 Sqm (3) 61 Cav OHT - 900 Sqm (4) Signal Pump house-6100 Sqmm (5) Rajendra chauk OHT - 400 Sqm (6) APS OHT - 1000 Sqm (7) JCO/OR OHT - 2500 Sqm (8) Comd Camp OHT - 900 Sqm (9) Comand Pump house - 5200 Sqmm (10) Borewell at Comd gate 2, Near railway phatak, New PH 02, Ph 04, Sub area near Booster ph, Comand camp, Sub area Officer mess - 6500 Sqm (11) khatipura Ph - 9200 Sqm (12) Para 3 Ph - 1200 Sqm Note :- (i) if contractor fails to clean the area of installation compete in all respect else recovery @ 500 per job shall be recovered from his dues and contractors claim shall not enter on this account. (ii) Contractor provide required T&P like as(Broom, Axe,saw,boucket etc) (iii) Contractor will resposible to maintain the pump house area clean for contract peroid.

1

-

-

... More
S&F in repair for non return valves, class PN 1.0 of 150 mm size with cast iron body and both ends flanged, IS-14846 marked comlpete with neoprene rubber gasket, jointing material and incl nuts/bolts/washer of suitable size etc including taking down old unsv complete all as specified and directed .

1

-

-

... More
M&L for water high pressure gauge including socket welded to measure pressure in the delivery pipe 0-300 Psi complete all as specified and directed.

6

-

-

... More
Providing water tank 5000 ltr water capacity with pump, motor and arrangement to fill water tanks through delivery pipe on failure of water supply by any means at site complete all as specified and directed. Note : Water collection should be done from nearby MES source of water borewell/OHT as directed by EIC.

50

-

-

... More
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil including trimming of tree roots in trenches complete all as specified and directed.

160.65

-

-

... More
Returning, filling-in, including spreading, watering and well ramming in layers not exceeding 25 cm thick each, in soft /loose soil complete all as specified and directed.

126.95

-

-

... More
Removing excavated surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.

33.7

-

-

... More
M & L Sand cushioning to PVC under ground cable with screened and washed tibba sand (non cohessive) and punning to provide a required cover complete all as specified and directed. Note : Punned thickness shall only be measured for payment.

30.4

-

-

... More
M & L Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) laid flat abutting each other with width of protection being equal to length of brick. The gap between adajcent bricks shall not exceed 10 mm as directed by Engineer-in-Charge.

3

-

-

... More
M&L for PCC (1:3:6) type C1 using 20 mm graded aggregate for making good the disturbed portion of road/floor/platform etc including form work and compaction etc complete all as specfied and directed .

1

-

-

... More
M&L for boring of existing road/path for laying of GI pipe for protection of cable under road including making good distrubed area/surface all as directed by Engr in charge

50

-

-

... More
Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole of size 16 Sqmm 4 core including taking down old unserviceable cable complete all as specified and directed

50

-

-

... More
Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole of size 25 Sqmm 3 ½ core including taking down old unserviceable cable complete all as specified and directed

365

-

-

... More
Supply, Laying, Jointing, testing & commissioning LT under ground cable XLPE insulated, screened PVC bedded, galvanised steel strips or wire armoured, heavy duty with multi stranded aluminium conductor, 1100 volts grade (ISI marked) laid in trenches, ducts, pipes or fixed on pole of size 70 Sqmm 3 ½ core including taking down old unserviceable cable complete all as specified and directed

30

-

-

... More
Repair & maintenance of existing header, welding work, jointing of pipe ,butter fly valve etc of header as per eixsting shape upto 150 mm to 600 mm bore pipe complete all as specified and directed.

10

-

-

... More
Replacement of existing MS pipe 150 mm bore 4.5 mm wall thickness including welding work complete all as specified and directed .

30

-

-

... More
M & L for Pipe Support for all types of pipes including hangars / fastners / elbows/ supports / tees and taking down unsv complete all as specified and directed.

10

-

-

... More
M & L for MS flanged joint for fixing existing header MS pipe with neoprene rubber gasket, SS nuts and bolts, jointing material and incl nuts/bolts/washer of suitable size etc and welding work including taking down old unsv complete all as specified and directed for following size : 150 mm bore 12 mm thickness

10

-

-

... More
,---ditto--- all as per item No 90 above but 350 mm bore 20 mm thickness complete.

4

-

-

... More
,---ditto--- all as per item No 90 above but 450 mm bore 20 mm thickness

3

-

-

... More
,---ditto--- all as per item No 90 above but 600 mm bore 20 mm thickness complete.

2

-

-

... More
M & L for MS dead flanged joint for fixing existing header MS pipe with neoprene rubber gasket, SS nuts and bolts, jointing material and incl nuts/bolts/washer of suitable size etc and welding work including taking down old unsv complete all as specified and directed for following size : 150 mm bore 12 mm thickness

2

-

-

... More
,---ditto--- all as per item No 94 above but 350 mm bore 20 mm thickness complete.

4

-

-

... More
,---ditto--- all as per item No 94 above but 450 mm bore 20 mm thickness complete.

3

-

-

... More
,---ditto--- all as per item No 94 above but 600 mm bore 20 mm thickness complete

2

-

-

... More
S&F in repair for sluice valves, class PN 1.6 of 80mm bore size with cast iron body, non rising type and cast iron wheel head, both ends flanged, IS-14846 marked comlete with neoprene rubber gasket, jointing material and incl nuts / bolts / washer of suitable size etc including taking down old unsv complete all as specified and directed.

3

-

-

... More
,---ditto--- all as per srl item No. 98 above but of size 100 mm bore complete.

1

-

-

... More
,---ditto--- all as per srl item No. 98 above but of size 150 mm bore complete.

2

-

-

... More
,---ditto--- all as per srl item No. 98 above but of size 200 mm bore complete.

1

-

-

... More
S&F in repair for non return valves, class PN 1.0 of 80mm bore size with cast iron body and both ends flanged, ISI marked comlete with neoprene rubber gasket, jointing material and incl nuts / bolts / washer of suitable size etc including taking down old unsv complete all as specified and directed.

4

-

-

... More
,---ditto--- all as per srl item No. 102 above but of size 100 mm bore complete.

1

-

-

... More
M & L for Butterfly valve 100 mm dia, ISI marked complete with all fittings/accessories, required for fixing in existing header including taking down old unsv complete all as specified and directed.

2

-

-

... More
Supply only calcium based high strength granular chlorination chemical (calcium hypochlorite having chlorine 65% to 70% ) for water treatment. Granular material shall be free of foreign material decomposing at 177 C soluble in water and alcohol not hygroscopic practically clear in water solution at saturation level. The material should not contain more than 5% to 10 % moisture. Granular size should be as follows:- Mesh passing through -100 BSS 1.5 % maximum iron as Fe 0.05% maximum Mn 40 PPM maximum Mol wt 142.98, Toxicity :Oral rate LD 50-850 mg/kg. duly tested from approved laboratory packed in a fibre drum duly sealed granular type from manufacturer or authorised dealer/distributor complete all as specified and directed. Note- Brand name/batch number and complete particulars of manufacturer should be printed on the container/packing.

1500

-

-

... More
M&L Earthing complete as per electrical plate No 3 of MES SSR Part I with galvanised steel plate earth electrode 60 cm x 60 cm x 6.0mm, burried directly vertically in ground in a pit of depth not less than 2.5 metres below ground level with the top edge of earth plate at a depth not less than 1.8m below normal ground level connected to and including galvanised iron or steel earth strip 32X6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel. Earthing wire protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole/ test point. Watering pipe shall be 20mm bore GI medium grade. The earthing shall be inclusive of excavation and earth work in any type of soil,charcoal, salt,funnel , PCC pit and RCC cover complete all as specified & directed. Note 1 - following items deemed to be included in quoted rate (a) Earth electrode. (b) Main earthing lead from earth electrode to test point and further to equipment to be earthed upto 7.5 metre. (c) Material and labour for connecting earth electrode and earthing lead as specified. (d) Adequate quantity of charcoal dust and common salt as per direction. (e) All labour involved including testing of earth net work. (f) Excavation and earth work or drilling hole for electrode. (g) P.C.C. pit and C.I. cover. (h) Funnel with watering pipe, wire mesh and copper lugs etc. as specified. (j) G.I. protection pipe of size ordered specified for protection of earthing lead from mechanical injury or tempering.

19

-

-

... More
Taking out of old existing unserviceable earthing lead of 32 x 6 mm size of galvanised iron strip or steel strip.

40

-

-

... More
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm GI strip.

40

-

-

... More
Taking out of old existing unserviceable GI protection pipe of dia 40 mm galvanised iron with all fittings complete all as specified and directed.

60

-

-

... More
Supply & fix tubes 40 mm dia 'light grade', galvanised, with all fitting laid in trenches for protection of GI strip complete all as specified and directed.

60

-

-

... More
M&L for taking out old/existing earthing pit by removal of unserviceale funnel and cover of earthing complete all as specified and directed.

35

-

-

... More
M&L for Making earthing pit as per electrical plate No. 3 with wire mesh, CI cover, Frame, funnel including necessary PCC work all as directed by EIC with testing complete all as specified and directed.

30

-

-

... More
Material and labour for preparation of old painted surface of electrical panel of Length (0.5 m to 1 m), Height (0.5m to 1m), Breadth( up to 0.5m), inner and outer surface by scrubbing with iron brush and applying two coat RAWL 7032/7035 paint with spray machine complete.

10

-

-

... More
,---ditto--- all as per item No. 113 above but of size Length (0.5 m to 1 m), Height (1m to 2m), Breadth (up to 0.5m) complete.

8

-

-

... More
,---ditto--- all as per item No. 113 above but of size Length (1 m to 2 m), Height (1m to 2m), Breadth( up to 0.5m) complete

5

-

-

... More
M&L for writing latters or figures (block, Romen, Italic,or indian) n exc. 30 Cm height, before writing painter will scrub/clean the floor/wall as per requirement dimention and double coat a base paint omplete all as specified and directed by engr in charge.

50

-

-

... More
M& L for repairing of LT panel including welding of doors, fixing of hinges, brazing etc complete all as specified and directed by EIC.

15

-

-

... More
Supply and fix in repair LED aviation/obstruction light on over head tank with die cast aluminium housing, IP 65 rating nominal voltage 240 volt 10 watt integral driver with wiring with 1.5 Sqmm 2 core wire up to the DB/ nearest panel of OHT complete all as specified and directed by engr in charge.

2

-

-

... More
M&L for preparation of old painted steel surface of centrifugal pump with motor and base up to 50 HP and applying two coats of synthetic enameled paint over applying one coat of red oxide primer complete all as specified and directed.

16

-

-

... More
M&L for preparation of old painted GI/MS/DI pipe surfaces upto 600 mm dia at various pump house/OHT and applying two coats of synthetic enameled paint over applying one coat of red oxide primer complete all as specified and directed.

100

-

-

... More
Supply only drinking water chlorine test kit of ISI mark of range min 0.2 PPM to Max 5 PPM and PH meter of range min 0 to Max 14 complete all as specified and directed.

9

-

-

... More
Supply & fix shock treatment chart (50x70 CM) with combined language hindi and english,chart should be laminated on both sides complete all as specified and directed.

10

-

-

... More
S & F in reapir insulation mat of thickness 3 to 6mm thick as per IS 15652, ISI marked of size 1m x 2m to safegaurd of electric shock complete all as specified and directed.

10

-

-

... More
S &F in repair notice board of size 3x4 feet premium material green colour notice board/soft board/pin- up display board with 50 pins for pump house with Alloy Aluminium Frame, softboard Core, Premium Flocked Fabric (Velvet) Cloth surface & Virgin ABS Corner complete all as specified and directed.

4

-

-

... More
Disconnecting & taking out the existing Unserviceable LT panel and S&F new outdoor Canopy type weather proof IP 54 LT panel board front opening hinged typed, double door with locking arrangement, made out of 3.15 mm thick CRCA sheet steel factory fabricated with powder coating with heat shrinkable PVC sleeves with colour code RYBN placed on insulators. The Aluminium bar RYBN having capacity is 1.5 times of main incomer MCCBs. The panel board shall be mounted 60 cm above ground level on a form work made out of MS channel of size 75 x 40 cm grouted on PCC Plateform. The sides of the form work shall be covered with 3.15 mm thick MS sheet and complete with necessary excavation PCC foundation, suitable cable glands for cable entry etc.The panel board shall be suitable housed with the following items:- (For Bore well pump house) (i) There should be sufficient space for fixing of starter for 15 HP submerssible pump-01 No (ii) 4 Pole MCCB 100 Amp with rupturing capacity 30 KA (Main Incoming)-1 Nos of Make- L&T (iii) 4 Pole MCCB 40 Amp with rupturing capacity 30 KA (Outgoing)-2 Nos of Make- L&T (iii)Volt meter 0-500 volts with selector switch.of Make- Meco (iv)Amp meter 0-300 Amp with selector switch of Make- Meco (v)Phase indictor lamps LED type set of three (RYB) - 01 Set (vi) Single phase preventor at incomer -01 Nos

3

-

-

... More
Disconnecting and taking out exisitng LT over heated or burnt cable terminal/ joint at panel/fidder piller & unserviciable portion of LT cable of any size, after that stretching/ opening cable to suitable required length etc and fixing aluminium lugs / joint material, Phase sequencial, cable gland and suitable nuts bolts & washer etc complete all as specified and directed by Engr-in-charge.

25

-

-

... More
M&L for collection of water from bisalpur water supply tap point at haldighati pump house and carried out the water test from NABL approved lab or govt lab as per ISO standard complete all as specified and directed.

4

-

-

... More
Note:- (a) Material like sluice valve, MCCB, cable, pipe etc shall be procured by contractor in one time for Min 75% quantity of as mentioned in BOQ of approved make from authorised dealer of manufacturer within 30 days of date of commencement and purchase vouchers and manufacturer test certificate (where applicable) shall be submitted by contractor before claim of payment. (b)The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.