Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681255_1Bid Award Id
ViewTender No
8415/24-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per item No 2 above but capacity 60 watt
100
-
-
... More
All as per item No 2 above but capacity 70 watt
50
-
-
... More
All as per item No 2 above but capacity 90 watt
50
-
-
... More
All as per item No 2 above but capacity 200 watt
30
-
-
... More
All as per item No 2 above but capacity 250 watt
30
-
-
... More
All as per item No 2 above but capacity 400 watt
15
-
-
... More
Supply and fix Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
Labour only for making unserviceable street/security lights/solar light serviceable placed at pole by disconnection / Isolating power supply either from pole junction box or by disconnecting overhead jumpers and carrying out de-carbonization / de-sulphation at connection points with overhead conductor / light fitting / junction box terminal including replacement connection wire complete all as specified and directed by Engineer-in-charge.
Note : - Cable shall be measured and paid separately.
450
-
-
... More
S&F Led Street Light of Capacity 60 Watt, including making electrical connection to the fitting with suitable size of wire, having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency Of ≥ 110 Lumens/Watt with toughend glass, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements including Connecting Up With
60
-
-
... More
ITEM NO. 12.00 CONTD...
Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket, Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report etc complete all as specified and directed by Engineer-in-charge. Make – Crompton cat No CRP-409-60-57-SL-GL-NSG, Havells Cat P. No ENDURAOMNIPLUSSL60WLED 757SASYTOPC, Wipro Cat No-LR02-671-XXX-57-G3 or equivalent in Appx 'C' list of makes.
-
-
-
... More
S&F Led street light of capacity 45 watt, including making electrical connection to the fitting with suitable size of wire, Having Pressure Die Cast Aluminium Housing, Ip-66 Having Efficiency of ≥ 110 Lumens/Watt, Operating Voltage – 120 – 270 Volts, P.F ≥ 0.95, T.H.D 10 % , Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver Also. The Fitting Must Be Suitable For 35 To 50 Mm O.D Mounting Pipe And Suitable For Mounting On Wall / Pole With Necessary Mounting Arrangements including Connecting Up With
60
-
-
... More
ITEM NO. 13.00 CONTD...
Three Core Twisted Flexible Copper Conductor Cable With Suitable Size, Mounting Pipe/Bracket, Nut, Bolts And Accessories Including Disconnected & Taking Down Old Unserviceable Light complete. The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report etc. complete all as specified and directed by Engineer-in-charge. Make – Crompton Cat No CRP-409-45-57-SL-GL-NSG Havells:- ENDURASUNDOWNSL45WLED 765PASYBOTG Wipro Cat No-LR02-671-XXX-57-G3 or equivalent in Appx 'C' list of makes.
-
-
-
... More
S&F Led Flood Light Fitting 200 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy = 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver including Disconnected & Taking Down Old Unserviceable Light Complete.
10
-
-
... More
ITEM NO. 14.00 CONTD...
The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X1.5 Sqmm Frlsh Wire, complete all as specified and directed by Engineer-in-charge. Make – Crompton Cat no CFS-501-200--57-60 D-SL-GL-NSG havells Cat no:- JETAIRIMAXFL200WLED757PWBLTG Wipro Cat no:- LF30-272-060-57-XX or equivalent in Appx 'C' list of makes.
-
-
-
... More
Supply & Fixing Led Flood Light Fitting 250 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy = 120lm/W And Total Lumens Output Must Be = 30,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F 0.95,Cct – 5700k, Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Separate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete.
10
-
-
... More
ITEM NO. 15.00 CONTD... The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X1.5 Sqmm Frlsh Wire, complete all as specified and directed by Engineer-in-charge. Make Crompton Cat no CFS-250-57-30 D-HL2-GL-NSG, Havells Cat No :-JETAIRIMAXFL250WLED757PWBLTG, Bajaj Cat no:-PRAZEF300L WH NB-A5 TG SD or equivalent in Appx 'C' list of makes.
-
-
-
... More
Supply & Fixing Led Flood Light Fitting 400 Watt Elegently Designed, Pressure Die Cast Aluminium Housing In Powder Coated Finish Ip-66, Lumen Efficacy = 120lm/W And Total Lumens Output Must Be = 48,000 Lumens Or More, Operating Voltage Range 120 – 270, P.F 0.95, , Cct – 5700k, Of Surge Protector Of 10 Kv Inside Fitting, Driver Of The Fitting Shall Be Potted Type Only For Vibration Proof Performance With Inbuilt Surge Protector, Over Voltage Protection. Both Fixture And Drivre Must Have Seperate Bis Marked Registration With Clearly Mentioned On Fixture & As Well As On Driver.Including Disconnected & Taking Down Old Unserviceable Light Complete.
10
-
-
... More
ITEM NO. 16.00 CONTD...
The Manufacturer Of The Led Fitting Shall Have Inhouse Nabl Accrediated Lab & Contractor Shall Furnish Same Along With Lm-79,Lm-80, Test Report Etc. Including Making Connection With 3 Core X1.5 Sqmm Frlsh Wire complete all as specified and directed by Engineer-in-charge.
Make Crompton Cat no CFS-400-57-30 D-HL2-GL-NSG, havells Cat No: JETAVALOURLEFL400W3MLED757PINTNBLTG, Wipro cat no:-LF45-502-060-57-XX or equivalent in Appx 'C' list of makes.
-
-
-
... More
Supply and fixing only in replacement of PVC insulated, sheathed weather proof, copper conductor of size 1.5 sqmm, 3 core complete all as specified and directed by Engineer-in-charge.
360
-
-
... More
Supply and fixing only in replacement of PVC insulated, sheathed weather proof, aluminium conductor of size 6 sqmm, 2 core complete all as specified and directed by Engineer-in-charge.
500
-
-
... More
M&L in replacement of PVC conduit 20 mm, heavy duty rigid non metallic including of all tee, bends, elbows etc complete all as specified and directed by Engineer-in-charge.
300
-
-
... More
S&F steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9 metres long) and including one coat of red oxide primer and two coat of aluminium paint over a pole including dismantlaing/taking out existing PCC/Steel tubular pole and making surface good complete all as specified and directed by Engineer-in-charge.
18
-
-
... More
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation for PCC poles/struts including necessary form work complete all as specified and directed by Engineer-in-charge.
0.97
-
-
... More
M & L for plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate in foundation of PCC pole /stay assembly including necessary form work up to groud level complete all as specified and directed by Engineer-in-charge.
9.7
-
-
... More
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) for pedestal/coping/plinth of poles, including necessary form work finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
0.7
-
-
... More
Taking out UG LT cable of any size/any core complete all as specified and directed by Engineer-in-charge.
3000
-
-
... More
Supply, laying, testing and commissioning of LT UG, XLPE insulated, heavy duty, 1100V grade of size 50 Sqmm 3.5 core electric cable with aluminium conductor, served with an inner sheathing of PVC tape armoured eith galvanized steel wire or tape and overall PVC sheathed,laid in trench or passing through pipe, making all connection with and including provision of necessary glands, lugs,bushing etc as required complete all as specified and directed by Engineer-in -charge.
Note:- Earthwork excavation sand cushioning, Jodhpur stone patti, GI protcetion pipe shall be measured and paid separately in their respective items.
500
-
-
... More
All as per item No. 25 above but size 10 Sqmm 2core
500
-
-
... More
All as per item No. 25 above but size 10 Sqmm 4core
600
-
-
... More
All as per item No. 25 above but size 16 Sqmm 4core
300
-
-
... More
All as per item No. 25 above but size 25 Sqmm 4core
300
-
-
... More
All as per item No. 25 above butsize 35 Sqmm 3.5 core
300
-
-
... More
Relaying of old retrieved servicable LT UG cable of any size /any core all as directed by Engr -in- charge
500
-
-
... More
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe/pole etc or soil for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5m in depth and getting out in Soft/disntegrated rock complete all as specified & directed by Engineer-in-Charge.
414
-
-
... More
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified & directed by Engineer-in-Charge.
405
-
-
... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge.
246
-
-
... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in any type of soil all as specified & directed by Engr-in-Charge.
238
-
-
... More
Removing excavated material soil/disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engr-in-Charge.
168
-
-
... More
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-Charge.
167
-
-
... More
Taking down the old existing unserviceable stone patti of any description complete all as specified & directed by Engineer-in-charge.
747
-
-
... More
M&L for laying 40 to 50 mm thick roughly hammer dressed jodhpur stone patti cable cover 25 cm to 30 cm wide and not exc 60 cm long each laid dry abuting with each other with maximum gap between adjacent patti/ slabs not exc 10 mm complete all as specified and directed by Engineer-in-charge.
647
-
-
... More
Laying only old stone patti complete all as specified and directed by the Engineer-in-Charge. Note :- Serviceable stone patti obtained from taking down with be used for laying.
100
-
-
... More
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge.
(Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
245
-
-
... More
S&F steel water tubing 40 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
18
-
-
... More
S&F steel water tubing 50 mm bore, 'medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.
18
-
-
... More
Supply and Fixing of pole mounted junction box of outer size 300x200x120mm made out of FRP body (hot mulded type) with IP-66 protection and locking with screws alongwith 6 Amp rating MCB SP-01 No, up to 50 Amp rated 4 pole connector suitable to insert the cable size up to 25 sqmm x 4 core -02 No and din rail suitable for mounting the MCB/Connector etc complete in side box and duly fixed with 25x3mm FI clamps with nut bolts of suitable size on steel tubular pole/PCC/RCC pole including cable glands, aluminum lugs/thimbles for incoming and out going cables and including taking down old existing unserviceable junction box complete all as specified and directed by the Engineer-in-Charge.
50
-
-
... More
S&F galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings and including taking down existing bracket of any description complete all as specified and directed by Engineer-in-charge.
30
-
-
... More
S&F miniature circuit breaker (MCB) of single pole SP 6-32 AMP 240V, 10KA 'B' curve in the MCB DB complete with connection testing and commissioning including dismantling existing MCB complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
S&F miniature circuit breaker (MCB) of single pole and neutral SPN 32 AMP 240V, 10KA 'C' curve in the MCB DB complete with connection testing and commissioning including dismantling existing MCB complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
Supply and fixing MCB, TPN 40 to 100 Amp, 415V 10KA 'B' curve miniature circuit breaker (MCB) of 4 poles and current carrying capacity in the DB complete with connection testing and commissioning including dismantling existing MCB complete all as specified and directed by Engineer-in-charge.
5
-
-
... More
Supply and fixing MCB, TPN 63 Amp, 415V 10KA 'B' curve miniature circuit breaker (MCB) of 4 poles and current carrying capacity in the DB complete with connection testing and commissioning including dismantling existing MCB complete all as specified and directed by Engineer-in-charge.
5
-
-
... More
Material and labour for straight through (Heat Shrinkable) cable jointing kit for 1.1 KV grade cable complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 10 to 50 Sqmm including dismantling the old burnt cable joint termination complete all as specified and directed by the Engineer-in-Charge.
10
-
-
... More
Material and labour for preparation of old painted surface of LT Concrete electric pole of any size by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior, synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos), including painting the cross arms/bracing support on poles with a coat of aluminium paint, silver colour aluminium paint with coating of primer and writing of identification Nos with proper stencil cut etc complete all as specified and directed by the Engineer-in-Charge.
250
-
-
... More
Material and labour for preparation of old painted surface of LT Steel tubular pole of any length by removing all dirt, dust,etc and painting complete surface up to pole top including connected accessories with dual coat of apex exterior, synthetic enamel paint over a coat of primer of approved colour of black and white strip 30 cm height (Total 5 Nos) & rest of the height of the pole is in silver colour aluminium paint, including bracing support on poles and writing of identification Nos with proper stencil cut etc complete all as specified and directed by the Engineer-in-Charge.
200
-
-
... More
Supply and fix Din type HRC fuse link of Required rating 32A/63A/100A Suitable for HG type 20H/2 and including taking out existing fuse of any description complete all as specified & directed by Engineer-in-charge.
100
-
-
... More
S&F Street light nature switch (using infrared sensor technology) based automatic street light control panel. the panel shuld be suitable enough to take 3 Phase load of 12 KW. Nature switch operation should be based on natural light Lux* level. required illuminance level for switching ON is ≤ 60 Lux and for switching off ≥ 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor alongwith suitable 3 Nos power Contractors and 03 Nos incoming MCB's 63 Amp & 3 Nos outgoing MCB's of 32 Amp each & circuit wiring (Copper) of min 10 sqmm with lug should be enclosed in a pole/wall mountable rust proof, electric shock proff, termite proof and FR grade SMC elclosure confirming to IP 66. The circuit should also have provision for manual operation (i.e. Sensor by Pass option) including taking down existing nature switch of any description complete all as specified and directed by the Engineer-in-charge.
3
-
-
... More
S&F street light nature switch (using infrared sensor technology) based automatic street light control panel. the panel shuld be suitable enough to take 3 Phase load of 8 KW. Nature switch operation should be based on natural light Lux* level. required illuminance level for switching ON is ≤ 60 Lux and for switching off ≥ 10 Lux. The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs. The sensor alongwith suitable 3 Nos power Contractors and 03 Nos incoming MCB's 63 Amp & 3 Nos outgoing MCB's of 32 Amp each & circuit wiring (Copper) of min 10 sqmm with lug should be enclosed in a pole/wall mountable rust proof, electric shock proff, termite proof and FR grade SMC elclosure confirming to IP 66. The circuit should also have provision for Manual operation (i.e. Sensor by Pass option) including taking down existing nature switch of any description complete all as specified and directed by the Engineer-in-charge.
3
-
-
... More
S&F nature switch (using infrared sensor technology) based automatic street light control panel. The panel should be enough to take three phase load of 25 kw.Nature switch operation should be based on natural light luxes. required illuminance level switching ON is =60 and for Switching OFF =10 lux. the senser should be have a part night operation facility of min 4HRS to max 12 hrs . the senser along with suitable 3 phase load of 25 KW with 3 nos contractor ,3 nos Incoming MCBs of 63 Amps and outgoing MCBs of 63 Amp and circuit wire copper of min 16 Sqmm and should be enclosed in a pole /wall mountig Rust proof ,Electric shock proof ,Termite proof and FR grade thermoplastic polycarbonate enclouser (with hinged lid) conforming to IP66 protection.The circuit should also have provision gor manual or auto operation including taking down existing nature switch of any description complete all as specified and directed by the Engineer-in-charge.
3
-
-
... More
Supply & fix MNX Power contactor suitable for power supply 40 Amps 4 pole 4 NO Contactor including making electrical connection to the contactor and including taking out existing power contactor complete all as specified & directed by Engineer-in-charge.
3
-
-
... More
Supply & fix MNX Power contactor suitable for power supply 63 Amps 4 NO Contactor including making electrical connection to the contactor and including taking out existing power contactor complete all as specified & directed by Engineer-in-charge.
3
-
-
... More
S&F Digital Astronomical timer switch 240V AC-2W,C/O, Base/DIN type complete for switching of contactors and including taking out existing timer switch complete all as specified & directed by Engineer-in-charge.
5
-
-
... More
Material and labour for cutting the existing bituminious road / hard standing to size not exceeding 45 CM wide and depth not less than 45 cm for passing UG cable through GI pipe and making good the good distrubed surface and filled excavated material and 200 mm depth with plane cement concrete 1:3:6 type C1 using 20 mm graded aggregate complete all as specified and directed by the Engineer-in-charge.
20
-
-
... More
S&F lithium based energy efficient Integrated solar street light of 20 watt in single body with FRP/Aluiminum duly polyurenthane coating encases with monocrystalline solar PV panel of 30/35Wp, Lithium battery 11.1/12.8 Volt, 24 Ah with inbuit BMS, IP 65/66, High brightness W-LED (120-180 Im/Watt) lamp with aluminium reflector for better lighting distribution, CRI 70, colour temperature 5700 K-6500 K, Microcontroller based charge controller cum driver, automatic dimming function with PIR motion sensor,Dusk to dawn operation weight not more than 10-12 KG with adjustable MS Clamp suitable for existing pole/wall mounting etc including taking down old existing solar street light complete all as specified and directed by the Engineer-in-charge.
Note : Short Circuit, overload, reverse polarity and battery protections to be provided. OEM should provide vital parameters test report from NABL accredited lab and should be of made in India with CE & TOHS complaint.
5
-
-
... More
Taking down and dismantling existing high mast pole of height 12 to 20 mtr from bottom plate, nuts bolts, gear box and head frame for dismantling the unserviceable parts including repair control panel wiring, old unsv lights, complete with the help of suitable T & P required for holding, lifgting the pole,replacement of unservicable part,oiling and greasing, of pulleys, gear box,rope and all moving parts including assembling, installation of high mast pole complete all as specified and directed by the Engineer-in-charge.
Note 1. Cost of crane for dismantling high mast pole is deemed to be included in quoted rate. 2. Cost of oling and greasing of moving parts is deemed to be quoted rate.
10
-
-
... More
Taking down by disconnected the existing electrical connection of winch motor for rewinding /repairs including rewinding the mortor of capacity up to 2 HP with best class supper enameled copper wire of existing guage and size including varnishes and insulating 230 V AC 50 HZ electric supply system . refixing and reconnected it to the original location for satisfactory functioning of wintch on 230 v electric supply system complete all as specified and directed by the Engineer-in-charge.
3
-
-
... More
Note : (a) Contractor has to arrange his own vehicles along with mounted hydraulic ladder/articulated & telescopic boom lift arrangement for attending the complaint throughout jaisalmer cantt area. (b) Contractor shall depute minimum 2 staff daily to attend and rectify the complaint. if not, Contractor shall have to bear a penalty of Rs 50.00 per complaint or maximum of Rs 500 per day on this account (c) Complaints has to attend and rectify the complaint/defect irrespective of no of trips/Complaints as alloted by Eng-in-Charge.(d) Complaint should be attend in Night also (d) Contractor has to arrange telescopic boom lift for maintenance at height of 15m at his own cost. No extra payment will be paid by department.
-
-
-
Evaluation Notes How It Works ?