Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Civil And Construction
Water Storage And Supply
Eprocure
Opening Date18 Dec 2024
Closing Date15 Jan 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Taking up or down 40 mm or 50 mm bore of steel tubing and connections, including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

100

-

-

... More
Taking up cast iron water mains (including all fittings), 80 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.

150

-

-

... More
Taking up 80 mm nominal size/ bore cast iron or galvanised iron or ductile iron water mains (including all fittings), with rubber gasket joints (push on joints) for spigot/socket end or flanged joints with flanged end joints including disconnecting pipes and fittings including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

150

-

-

... More
Taking up cast iron water mains (including all fittings), 100 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.

250

-

-

... More
Taking up 100 mm nominal size/ bore cast iron or galvanised iron or ductile iron water mains (including all fittings), with rubber gasket joints (push on joints) for spigot/socket end or flanged joints with flanged end joints including disconnecting pipes and fittings including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

250

-

-

... More
Taking up cast iron water mains (including all fittings), 150 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.

236

-

-

... More
Taking up 150 mm nominal size/ bore cast iron or galvanised iron or ductile iron water mains (including all fittings), with rubber gasket joints (push on joints) for spigot/socket end or flanged joints with flanged end joints including disconnecting pipes and fittings including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

236

-

-

... More
Taking up cast iron water mains (including all fittings), 200 mm nominal size, with spigot and socket ends and lead joints including burning out joints and recovering lead complete all as specified and as directed.

60

-

-

... More
Taking up 200 mm nominal size/ bore cast iron or galvanised iron or ductile iron water mains (including all fittings), with rubber gasket joints (push on joints) for spigot/socket end or flanged joints with flanged end joints including disconnecting pipes and fittings including cleaning for refixing or removal to store or taken on schedule of credit complete all as specified and as directed.

60

-

-

... More
Supplying & laying in trenches 50 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

100

-

-

... More
Supplying & laying in trenches 80 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

100

-

-

... More
Supplying, laying, connecting, jointing and testing in trenches 80 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.

300

-

-

... More
Supplying, laying, connecting, jointing and testing in trenches 100 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.

500

-

-

... More
Supplying, laying, connecting, jointing and testing in trenches 150 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.

472

-

-

... More
Supplying, laying, connecting, jointing and testing in trenches 200 mm nominal dia ductile iron pressure pipe for water mains, centrifugally cast, spigot and socket ends (for push on joints), class K7 in any length with external protection of Metallic zinc with finishing layer of bituminous paint and internal linings of Portland cement (with or without additives) mortar with seal coat, all as per IS 8329: 2000 and including materials and jointing with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 complete all as specified and as directed.

120

-

-

... More
Cutting the existing cast iron/ galvanised iron pipes 80 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed.

10

-

-

... More
Cutting the existing cast iron/ galvanised iron pipes 100 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed.

10

-

-

... More
Cutting the existing cast iron/ galvanised iron pipes 150 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed.

10

-

-

... More
Cutting the existing cast iron/ galvanised iron pipes 200 mm bore in position for insertion of new tees, branches, etc. complete all as specified and as directed.

10

-

-

... More
S & F in repairs flanged reflux valve (non-return) of single door, swing check type nominal pressure (PN 1.6) of preferred materials as per IS 5312 (Part 1): 2004, nominal size 80 mm complete all as specified and as directed.

6

-

-

... More
S & F in repairs flanged reflux valve (non-return) of single door, swing check type nominal pressure (PN 1.6) of preferred materials as per IS 5312 (Part 1): 2004, nominal size 100 mm complete all as specified and as directed.

6

-

-

... More
M & L for cleaning, upkeeping and maintaining of MES installations / campus/ outside the periphery of transformer platform/ two poles structure/ four pole structures by surface dressing or trimming of natural ground to remove small inequalities not exceeding 15 cm deep (including removing vegetation / shrubs / brush wood / under-growth) including carrying away the rubbish to a distance of not exceeding 50 m away complete all as specified and as directed. Note: - The contractor shall clean, upkeep and maintain the premises during the contract period and the payment shall be made only once for entire contract period. The measurement shall be in sqm.

2000

-

-

... More
Taking down sluice valve of nominal size of 80 mm and M & L for replacing of nuts, bolts, gasket, gland packing etc. including greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

8

-

-

... More
Taking down sluice valve of nominal size of 100 mm and M & L for replacing of nuts, bolts, gasket, gland packing etc. including greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

6

-

-

... More
Taking down sluice valve of nominal size of 150 mm and M & L for replacing of nuts, bolts, gasket, gland packing etc. including greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

10

-

-

... More
Taking down sluice valve of nominal size of 200 mm and M & L for replacing of nuts, bolts, gasket, gland packing etc. including greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

2

-

-

... More
Taking down sluice valve of nominal size of 250 mm and M & L for replacing of nuts, bolts, gasket, gland packing etc. including greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

1

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 80 mm including dismantling, burning out joints and recovering lead and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

40

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 100 mm including dismantling, burning out joints and recovering lead and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

50

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 150 mm including dismantling, burning out joints and recovering lead and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

40

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 200 mm including dismantling, burning out joints and recovering lead and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

10

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 250 mm including dismantling, burning out joints and recovering lead and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

5

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 80 mm in vertical position upto 25 metre height including dismantling, burning out joints and recovering lead and including dewatering complete all as specified and as directed.

1

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 100 mm in vertical position upto 25 metre height including dismantling, burning out joints and recovering lead and including dewatering complete all as specified and as directed.

1

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 150 mm in vertical position upto 25 metre height including dismantling, burning out joints and recovering lead and including dewatering complete all as specified and as directed.

1

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 200 mm in vertical position upto 25 metre height including dismantling, burning out joints and recovering lead and including dewatering complete all as specified and as directed.

1

-

-

... More
M & L for lead wool caulked joint for spigot and socket cast iron pipes and fittings of nominal bore 250 mm in vertical position upto 25 metre height including dismantling, burning out joints and recovering lead and including dewatering complete all as specified and as directed.

1

-

-

... More
M & L for repair of leaking joint in 80 mm bore PVC pipeline by removing existing broken fitting, rethreading of pipes and supply & fixing new PVC fittings like union/ elbow/ socket/ tee/ reducer/ plug/ flange etc. in place of broken fittings and reconnecting of pipe, testing of joint, including necessary excavation & earth work in any type of soil including dewatering complete all as specified & as directed. NOTE: - (i) The contractor shall be responsible for making good the damages occurred during working. The decision of the Accepting Officer shall be final and binding regarding defects /damages /breakage of existing equipment / lines / structures etc. (ii)The job should be completed within 8 hours from the receipt of complaint failing which a recovery of ₹300.00 per complaint per hour shall be made.

15

-

-

... More
M & L for repair of leaking joint in 80 mm bore GI pipeline by removing existing broken fitting, rethreading of pipes and supply & fixing new GI fittings like union/ elbow/ socket/ tee/ reducer/ plug/ flange etc in place of broken fittings and re-jointing of pipe, testing of joint including necessary excavation & earth work in any type of soil including dewatering complete all as specified & as directed. NOTE: - (i) The contractor shall be responsible for making good the damages occurred during working. The decision of the Accepting Officer shall be final and binding regarding defects /damages /breakage of existing equipment / lines / structures etc (ii)The job should be completed within 8 hours from the receipt of complaint failing which a recovery of ₹300.00 per complaint per hour shall be made.

15

-

-

... More
M & L for repair of leaking joint in 100 mm bore GI pipeline by removing existing broken fitting, rethreading of pipes and supply & fixing new GI fittings like union/ elbow/ socket/ tee/ reducer/ plug/ flange etc in place of broken fittings and re-jointing of pipe, testing of joint including necessary excavation & earth work in any type of soil including dewatering complete all as specified & as directed. NOTE: - (i) The contractor shall be responsible for making good the damages occurred during working. The decision of the Accepting Officer shall be final and binding regarding defects /damages /breakage of existing equipment / lines / structures etc (ii)The job should be completed within 8 hours from the receipt of complaint failing which a recovery of ₹300.00 per complaint per hour shall be made.

20

-

-

... More
M & L in repairs for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 80 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.

4

-

-

... More
M & L in repairs for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 100 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.

5

-

-

... More
M & L in repairs for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 150 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.

5

-

-

... More
M & L in repairs for non-rising stem type sluice valves having double flanged for connections of nominal pressure (PN 1.6) as per IS 14846: 2000 of preferred materials, nominal size 200 mm including nuts, bolts, packing sheets etc. complete all as specified and as directed.

1

-

-

... More
Taking down sluice valve of nominal size of 80 mm and M & L for replacing of nuts, bolts, gasket, gland packing, gunmetal scour (gutka), stuffing box etc. including refacing, regrinding, greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

4

-

-

... More
Taking down sluice valve of nominal size of 100 mm and M & L for replacing of nuts, bolts, gasket, gland packing, gunmetal scour (gutka), stuffing box etc. including refacing, regrinding, greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

4

-

-

... More
Taking down sluice valve of nominal size of 150 mm and M & L for replacing of nuts, bolts, gasket, gland packing, gunmetal scour (gutka), stuffing box etc. including refacing, regrinding, greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

5

-

-

... More
Taking down sluice valve of nominal size of 200 mm and M & L for replacing of nuts, bolts, gasket, gland packing, gunmetal scour (gutka), stuffing box etc. including refacing, regrinding, greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

1

-

-

... More
Taking down sluice valve of nominal size of 250 mm and M & L for replacing of nuts, bolts, gasket, gland packing, gunmetal scour (gutka), stuffing box etc. including refacing, regrinding, greasing and including refixing with new nuts, bolts, packing sheets etc. at same or other locations complete all as specified and as directed.

1

-

-

... More
M & L for rubber ring or push on joint for spigot and socket cast iron or ductile iron pipes and fittings of nominal bore 200 mm with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 including dismantling joints and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

2

-

-

... More
M & L for rubber ring or push on joint for spigot and socket cast iron or ductile iron pipes and fittings of nominal bore 250 mm with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 including dismantling joints and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

2

-

-

... More
M & L for rubber ring or push on joint for spigot and socket cast iron or ductile iron pipes and fittings of nominal bore 300 mm with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 including dismantling joints and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

1

-

-

... More
M & L for rubber ring or push on joint for spigot and socket cast iron or ductile iron pipes and fittings of nominal bore 50 mm with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 including dismantling joints and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

10

-

-

... More
M & L for rubber ring or push on joint for spigot and socket cast iron or ductile iron pipes and fittings of nominal bore 80 mm with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 including dismantling joints and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

10

-

-

... More
M & L for rubber ring or push on joint for spigot and socket cast iron or ductile iron pipes and fittings of nominal bore 100 mm with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 including dismantling joints and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

15

-

-

... More
M & L for rubber ring or push on joint for spigot and socket cast iron or ductile iron pipes and fittings of nominal bore 150 mm with rubber gasket for WA type of application and hardness class 50 for bulb and hardness class 80 for heel all as per IS 5382: 2018 and IS 12820: 2004 including dismantling joints and including excavations and earthworks in any type of soil, dewatering complete all as specified and as directed.

10

-

-

... More
S & F in repairs PVC detachable joint with rubber ring, ISI marked, suitable for upto 100mm bore pvc pipe specials with nuts, bolts including necessary excavation & earth work in any type of soil including dewatering complete all as specified & as directed.

20

-

-

... More
Dismantling of the existing valve chamber & M & L for construction of new valve pit/chamber of size 1350 mm (Length) X 1000 mm (Breadth) X 1200 mm (depth) including necessary earth work in any type of soil, PCC foundation M7.5(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate as in base concrete, brick work with sub class 'B' bricks, non-modular sizes as per IS 1077: 1992, straight or curved on plan exceeding 6 m mean radius built in cement mortar 1:6, cement plaster 20 mm thick internally in two coats of (15 mm and 5 mm) in cement mortar 1:4, 3 mm thick mild steel sheet of any grade and designation as per IS 513: 2008 and IS 10748: 2004 welded with angle iron (40 mm X 40 mm X 6 mm) frame of structural steel, frame welded with angle iron (50 mm X 50 mm X 6 mm) frame of structural steel, welded to flat iron of size 150 mm X 50 mm X 6 mm of structural steel, fixed with bolt of 16 mm dia anchored with plate of size 100 mm X 100 mm X 3 mm of structural steel, bolt and anchored plate embedded in 250 mm thick PCC coping in M15(Nominal Mix) using 20 mm nominal size graded crushed stone aggregate, mild steel handle, grade E165 as per IS 15911: 2010 for structural steel with necessary, welding, riveting, bolting including painting exposed steel surfaces with two coats of bituminous paint and embedded surfaces of steel with two coats of tar, finishing exposed faces of concrete surfaces and plaster surfaces with three coats of white wash and all as per drawing No. TD/2004/26 Sheet Nos 1/3, 2/3 and 3/3 of HQ CE Jaipur Zone complete all as specified and as directed.

8

-

-

... More
Supplying, laying, joining and testing 100 mm nominal bore, medium grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 and including flange joint as per IS 6392: 2020 of class 2.5 for suction and delivery pipe for pump complete all as specified and as directed.

30

-

-

... More
Attending complaints of external water supply pipeline/ installations/ control vales etc. as when required round the clock for any defect and rectifying the defects by tightening loose connections, replacing parts etc. including excavations and earthworks complete all as specified and as directed. Note: - (a) The quoted rate shall be only for the labour component. Spare parts shall be measured separately. (b) Excavations and earthwork shall be included in the scope of works. (c) The item shall not be measured separately if the defects are rectified under other items as S & F or M & L. (d) Rectification of defects at the same location shall be considered as one unit irrespective of any numbers of recertifications. (e) Adequate tradesman /supporting manpower shall be deployed by the contractor, and they shall be available for attending the complaints. (f) The supervisor /site Engineer of the contractor shall obtain the complaint slip duly signed along with detailed instructions from the JE every morning for attending complaints on daily basis. (g) The complaint shall be resolved within 8 hours from the receipt of complaint failing which a recovery of ₹25.00 per complaint per hour shall be made.

270

-

-

... More
Material, labour, tools, plants etc for drilling borehole for extending the depth of borewell having 250 mm dia by any of the methods mentioned in IS 2800: 2019 (cable tool, hand boring, direct circulation rotary, reverse circulation rotary, dual rotary) or any other methods and as decided by the Engineer-in-Charge in any kind of soil strata including hard stone/boulder upto 300 metre depth below ground level, including compound/ powder like valmite, bentonite solution, local silty clay etc. to be required as per the site condition including collecting samples from different strata, preparing and submitting strata chart/ bore log all complete all as specified and as directed.

240

-

-

... More
Supplying, assembling, jointing and lowering steel casing pipe for water wells, plain ended, 200 mm nominal bore of pipe, 5.4 mm wall thickness, ERW (Electric Resistance Welded) type, Fe 450 grade of steel, externally coated with bituminous solution conforming to IS-4270-2001 and fixing in position in different depth as directed, butt welded complete all as specified and as directed.

170

-

-

... More
Supplying, assembling, jointing and lowering plain slotted pipe, type A, screen made of low carbon galvanized (LCG) steel, 200 mm nominal size, 8 mm wall thickness, 0.75 mm slot openings conforming to IS-8110: 2019 and fixing in position in different depth as directed, butt welded complete all as specified and as directed.

30

-

-

... More
S & F well cap to the top of borewell, made of flat iron of hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 and as per IS 2800: 2019 including necessary bolts & nuts of required size complete all as specified and as directed.

3

-

-

... More
Supplying, designing, packing gravel, hard quartz (about 90-95 percent silicon dioxide (SiO2)) or other suitable material with an average specific gravity of not less than 2.5, not more than 10 percent by weight of the material shall have specific gravity of less than 2.25, not contain more than 5 percent by weight of calcareous material, not more than 2 percent by weight of thin flat or elongated pieces, the larger dimension not be more than 3 times the smallest dimension, sub rounded to rounded grains with least angular features, free from impurities such as shale, mica, feldspar, clay, dirt, loam, hematite, organic material etc. for the tube well in accordance with IS: 4097: 2019 as per the site requirement complete all as specified and as directed.

15

-

-

... More
Development of tube well in accordance with IS 2800: 2019 and IS:11189 with compressed air method (open well method), to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed complete all as specified and as directed.

22

-

-

... More
Determining specific capacity and efficiency and carrying out yield test as per IS 2800: 2019 using test pump and determining the yield capacity of borewell, the rate of pumping without lowering the water level below the top boundary of the aquifer, the top of the perforations, the recommended rate of pumping complete all as specified and as directed.

1

-

-

... More
S & F clamp for housing/ casing pipe, made of flat iron of hot rolled medium and high tensile structural steel of grade E 250 quality C conforming to IS 2062: 2011 and as per IS 2800: 2019 including necessary bolts & nuts of required size complete all as specified and as directed.

20

-

-

... More
M & L for cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs, slab staging for water tanks, filling of pressed steel door frame, fixing of hold fasts and the like including weathering, slightly rounded or chamfered angles and throating including necessary formworks complete all as specified and as directed.

0.25

-

-

... More
M & L for 50 mm bore GI medium grade column pipe in 6 m length with flanged joints duly screwed and welded with pipe suspended in deep well complete with groove to house submersible cable, GI flanges, rubber gasket, clamps, bolts, nuts, etc. complete all as specified and as directed.

180

-

-

... More
S & F bail plug/ bottom plug with hook, 200 mm size, made of material as per IS 4270: 2001, conforming to IS 2800: 2019 complete all as specified and as directed.

1

-

-

... More
Carrying out testing of water sample of untreated water for all parameters mentioned in Table 1 to Table 6 of IS 10500: 2012 from any government approved Lab or Engineering College as approved by the GE complete all as specified and as directed.

1

-

-

... More
Disinfection of borewell as per IS 2800: 2019 using 1000 milligrams of powdered chlorine compound per litre of water present in the well, thoroughly mixed in the well by surging with pump, left in the well for at least 6 hours, surged at about 2 hour interval, well to be pumped back into the well for 30 minutes and after that pumped into the waste to ensure elimination of any bacteria, odour etc. complete all as specified and as directed.

1

-

-

... More
Resistivity variation studies in bore hole drilled by electric logging of pilot bores by expert of Geology division to know the potential and temperature probes of drinking water by approved agency duly collaborated with strata chart/bore log complete all as specified and as directed.

1

-

-

... More
Supplying, installing, lowering, testing & commissioning of energy efficient, electric driven, multistage submersible pump set complete with three phase electric motor of capacity 2 kW, 415 V, 2820 rpm as per IS 8034, capable of delivering at 180 metre head with discharge rate of 4.0 litre per second, made of stainless steel body and impeller, cast iron diffuser and discharge casing and including mild steel iron hook - 2 Nos welded at the top of the motor suitable to tie with SWR rope for anchoring including one No non return valve complete all as specified and as directed.

1

-

-

... More
Dismantling existing LT feeder pillar box/ LT panel board of any type and size including recovering serviceable items including making good disturbed surfaces complete all as specified and as directed.

3

-

-

... More
Supplying, installing, testing and commissioning factory made, CPRI approved, outdoor type, floor mounting LT panel board of adequate size, made of cold rolled close annealed sheet of 3 mm thick with 50 mm X 50 mm X 6 mm angle iron frame works, powder coated, dust & vermin proof, front and rear openable, double doors, compartmentalized, Form 4b construction, conforming to IS/IEC 61439 (Part 0 to 7), locking arrangements, suitable for 3 phase 4 wire 415 V, 50 Hz with 375 Amps rated copper bar fully insulated with class F materials and nuts, bolts, washers for connection including wiring with single core PVC power cable of suitable size and including mounting on angle iron frame made using angle iron 50 mm X 50 mm X 6 mm complete all as specified and as directed. and shall be comprising the followings: - (A) 375 Amps rated copper bar fully insulated with class F materials and nuts, bolts, washers for connection – 4 Nos (B) Wiring with single core PVC, copper power cable of suitable size (C) Accessories: (a) MCCB rated current (In): 100 A, Icu: 36 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic setting, four pole: 2 Nos (b) MCCB rated current (In): 63 A, Icu: 16 kA, Ics: 100% of Icu, Uimp: 8 kV, Ui: 690 V, IP40, adjustable thermal (80% to 100%) and adjustable magnetic setting, four pole: 1 No (c) Digital voltmeter 0-500 V withs selector switch – 1 No (d) Digital ammeter 0-50 Amps with selector switch – 1 No (e) LED indicating lamps – 3 Nos (f) On load changeover switch of capacity 100 A, four pole, 415 V- 01 No (g) 3 kVAR MPP dielectric type, heavy duty, resin filled bottle type, self-healing type, shunt capacitor- 1 No (h) Single phase preventor mini lec VSP-II-01 No (i) Phase sequence corrector 15 HP motor, 3 phase-01 No (j) Star delta starter, fully automatic suitable for 15 HP 3 phase electric motor - 01 No (D) PCC platform of height 750 mm (450 mm above and 300 mm below ground level) constructed with M10 (Nominal Mix) concrete using 20 mm nominal size crushed stone aggregate shall be provided for placing LT Panel Board. The length and breadth of foundation shall be 300 mm more on all sides than the size of the panel. The panel shall be fixed with platform using adequate size and numbers of anchor bolts grouted PCC platform.

3

-

-

... More
S & F in repairs submersible cable flat PVC insulation of type C and having PVC sheath of type ST2, flexible copper conductor, FR-LSH, 3 core of size 10 sqmm complete all as specified and as directed.

490

-

-

... More
Disconnecting, taking out old unserviceable under ground cable of rated voltage 1100 V, nominal cross sectional area of main conductor 25 sqmm, upto 4 core, any type from trenches including taking out concrete cable cover/ bricks etc. including removing materials to store for keeping in safe custody or for taking credit complete all as specified and as directed.

234

-

-

... More
Supply, laying, jointing, testing and commissioning cross-linked polyethylene (XLPE) insulated cable for working voltages of 1100 V, PVC sheathed, armoured, 3 core with reduced neutral conductors (3½ core), nominal cross sectional area of main conductor 25 sqmm, stranded aluminium conductor, ISI marked as per IS 7098(Part-I): 1988 including cable glands, lugs etc. to suit the cable size and to be laid in trenches, fixed along pole, under floors, through pipe laid under floors/roads and in trenches, through concealed GI pipe along wall etc. complete all as specified and as directed.

234

-

-

... More
Supplying & laying in trenches, in road cutting and along pole 50 mm nominal bore, light grade, galvanised coated steel tube conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 complete all as specified and as directed.

10

-

-

... More
M & L for earthing complete with galvanised steel plate earth electrode 600 mm X 600 mm X 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to earthing lead of 25 mm X 4 mm galvanised mild steel strip by means of bolts, nuts, check nuts and washers of galvanised iron from earth plate to test point upto 7.5 metre including all as shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete chamber in cement concrete M15 (Nominal Mix) using 20 mm nominal size coarse aggregate, precast RCC cover slab in cement concrete M15 (Nominal mix) using 20 mm nominal size coarse aggregate of size 40 cm X 40 cm X 5 cm reinforced with 8 mm dia TMT bars @ 150 mm c/c both ways with one handle for lifting made out of 8 mm dia bar, GI funnel, GI wire mesh filter, 20 mm dia GI pipe medium grade for watering, 40 mm dia GI pipe medium grade for protection of earthing lead, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil/ strata and testing complete all as specified and as directed.

2

-

-

... More
M & L for cement concrete in foundation, filling and mass concrete in M15(Nominal Mix) using 40 mm nominal size graded crushed stone aggregate complete all as specified and as directed.

2.5

-

-

... More
M & L for cutting galvanised mild steel pipe of nominal bore upto 250 mm, in position for and including insertion of new tee piece including necessary fittings and fixtures complete all as specified and as directed.

2

-

-

... More
S & F analogue water flow meter, 80 mm nominal size, cast iron body flanged ends & drilled horizontal heavy duty including jointing material etc. for submersible pump complete all as specified and as directed.

1

-

-

... More
M & L for laying of bricks locally available sub class 'B' bricks, non-modular sizes as per IS 1077: 1992 for cable protection cover laid flat and dry in trenches over the cable perpendicular to the direction of cable complete all as specified and as directed.

1600

-

-

... More
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling, hand punning down complete all as specified and as directed. Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.

40

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.