Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Coronavirus COVID 19
Eprocure
Opening Date16 Oct 2018
Closing Date13 Nov 2018
Tender Amount₹ 7,48,368 This is an estimated amount, exact amount may vary.
Costs
EMD
₹ 20,000Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2018_MES_215214_1Bid Award Id
ViewTender No
NIT 8929-20/18-19Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per srl item no 2 here-in-before but 5 pin 5 Amp socket outlet on the on independent board
40
-
-
... More
All as per srl item no 2 here-in-before but controlled by two no. 2 way switches
10
-
-
... More
Material and labour for concealed Point wiring complete with 1.5 Sqmm (nominal cross section area) FRLSH PVC insulated unsheathed and multi strand copper conductor cable 1100 volt (ISI marked) drawn through existing steel/ PVC rigid conduit/casing capping with fittings and accessories if required i.e. pipe bend, pipe hook, elbow, junction box, Pressed steel powder coated sunken box of suitable size (Min 60mm deep, suitable length and 1.2mm thick), 3mm thick bakelite plastic laminated sheet for mounting of switches and socket, fan regulator, for light /fan/ bell point controlled by one switch, top cover fixed with brass screws & cup washers including provn of 1.5Sqmm FRLSH PVC insulated multi strand copper conductor wire continues as earth wire connected to earth dolly etc. including cutting chases in wall and making good disturbed surfaces of walls/ceiling/floors etc. by using CM (1:3) to matching with existing surfaces complete all as specified and as directed by Engineer-in-charge. (switches , sockets etc. shall be measured and paid separately under appropriate item of BOQ).
112
-
-
... More
All as per srl item no 6 here-in-before but 5 pin 5 Amp socket outlet on the same board with other switches
10
-
-
... More
All as per srl item no 6 here-in-before but 5 pin 5 Amp socket outlet on the on independent board
10
-
-
... More
All as per srl item no 2 here-in-before but point wiring with 4 Sqmm multi strand copper conductor cable and 2.5 Sqmm copper conductor cable as earth wire for 2 in 1, 6 pin 15 Amp socket outlet on independent board
10
-
-
... More
All as per srl item no 6 here-in-before but point wiring with 4 Sqmm multi strand copper conductor cable and 2.5 Sqmm copper conductor cable as earth wire for 2 in 1, 6 pin 15 Amp socket outlet on independent board
5
-
-
... More
Supply and fixing switch piano flush type, 5/6Amps, 230 volts, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
240
-
-
... More
Supply and fixing in repair switch piano flush type, 5/6Amps, 230 volts, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
500
-
-
... More
Supply and fixing switch piano flush type, 5/6Amps, 230 volts, single pole, two way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
20
-
-
... More
Supply and fixing socket outlet,5 pin 5 Amp flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
70
-
-
... More
Supply and fixing in repair socket outlet,5 pin 5 Amp flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
200
-
-
... More
Supply and fixing bell push, flush type, 5/6Amps, 230 volts, fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
12
-
-
... More
Supply and fixing switch piano flush type, 15/16Amps, 230 volts, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
15
-
-
... More
Supply and fixing in repair switch piano flush type, 15/16Amps, 230 volts, single pole, one way fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
100
-
-
... More
Supply and fixing socket outlet 2 in 1,3 pin 5 Amp and 3 pin 15 Amp flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
15
-
-
... More
Supply and fixing in repair socket outlet 2 in 1,3 pin 5 Amp and 3 pin 15 Amp flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge. (laminated sheet shall be measured and paid in point wiring item of BOQ).
300
-
-
... More
S & F in repair sheet metal enclosure SPN with two pin and earth plug & socket complete including one MCB 20 Amp 240 volt SP "C" curve having over load & short circuit protection complete all as specified and directed by Engineer-in-charge.
20
-
-
... More
Supply and fixing lamp holder, PVC / polycarbonate type with back plate including 9 watt LED lamp complete all as specified and directed by Engineer-in-Charge.
60
-
-
... More
Supply and fixing ceiling rose surface Bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-charge.
50
-
-
... More
Supply and fixing fan regulator socket type 80/100 watt for ceiling fan complete all as specified by Engineer-in-charge.
40
-
-
... More
Supply and fixing in repair fan regulator socket type 80/100 watt for ceiling fan complete all as specified by Engineer-in-charge.
50
-
-
... More
Supply & Fixing electric Bell, ding dong AC 230 Volts single pole complete all as specified and as directed by Engr-in-charge.
12
-
-
... More
Supply & Fixing in repair electric Bell, ding dong AC 230 Volts single pole complete all as specified and as directed by Engr-in-charge.
50
-
-
... More
S & F in repair LED light fitting 1 x 18 Watt, 230 Volts Baton integreated channel type with T-5 tube pre wired for LED tube fixed to ceiling/ wall and connecting with 2 core flexible PVC insulated multistrand copper conductor from ceiling rose to fitting complete. Cat part -HLPT51520 complete of Make HPL or equivalent in any of the make mentioned in list of products.
650
-
-
... More
S&F in repair LED tube Rod retrofit 20 watt in place of old tube rod 230 volt 50 Hz, T-8 tube and making necessary alteration in existing fitting and making all electical connection complete all as specified and as directed. Make:- HPL Cat part No HLPT81418PC or equivallent in any of the make mentioned in list of products.
320
-
-
... More
S&F in repair recessed mounted square LED down lighter 18 watt with aluminium frame LED panel high quality diffuser for uniform light and high efficiency of size 1 x 1 luminaire with driver and bottom opening complete all as specified and as directed. Make HPL Cat Pt No HLPLEDSQDL18CW or equivallent in any of the make mentioned in list of products.
10
-
-
... More
Supply and fixing in repair bulk head fitting with LED of 10 watt complete all as specified and as directed. MakeHPLCat Pt NoHLPLEDBH10W LED or equivallent in any of the make mentioned in list of products.
20
-
-
... More
Supply and fixing in repair switch socket combination 2 in 1,5 pin 5 Amp flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge.
180
-
-
... More
Supply and fixing in repair switch socket combination 2 in 1,3 pin 5 Amp and 3 pin 15 Amp flush type fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge.
100
-
-
... More
Supply and fixing in repair modular socket outlet,5 pin 5 Amp 2 module fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge.
40
-
-
... More
Supply and fixing in repair modular socket 3 pin 5 Amp and 3 pin 15 Amp flush type 2 module fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge.
40
-
-
... More
Supply and fixing in repair modular switch 1 way 5 Amp 1 module fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge.
60
-
-
... More
Supply and fixing in repair modular switch 1 way 15 Amp 1 module fixed on laminated sheet complete all as specified and as directed by Engineer-in-charge.
30
-
-
... More
Supply and fixing in repair factory made DB SPN, 12 Way, 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43,including the following MCB, conforming to IS-8623, BS-5484 dust and vermin proof complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fixing in repair factory made DB SPN, 8 Way, 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43,including the following MCB, conforming to IS-8623, BS-5484 dust and vermin proof complete all as specified and directed by Engineer-in-charge.
4
-
-
... More
Supply and fixing in repair factory made DB SPN, 4 Way, 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43,including the following MCB, conforming to IS-8623, BS-5484 dust and vermin proof complete all as specified and directed by Engineer-in-charge.
6
-
-
... More
Supply and fixing in repair factory made DB TPN, 4 Way, 240V, double door, earth bar, copper bus bar 200 Amp and neutral link, protection class IP-43,including the following MCB, conforming to IS-8623, BS-5484 dust and vermin proof complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fixing in repair MCB TP 415 volt 63 amps, 9 KA,"C" curve with short circuit & over load protection complete all as specified and as directed.
4
-
-
... More
Supply and fixing in repair MCB SP 240 volt 63 amps, 9 KA,"C" curve with short circuit & over load protection complete all as specified and as directed.
30
-
-
... More
Supply and fixing in repair MCB SPN 240 volt 32 amps 9 KA,"C" curve with short circuit & over load protection complete all as specified and as directed.
80
-
-
... More
Supply and fixing in repair MCB single pole 240 volt 6-32 amps 9 KA,"C" curve with short circuit & over load protection complete all as specified and as directed.
240
-
-
... More
Supply and fixing in repair MCB TPN 415 volt 63 amps, 9 KA,"C" curve with short circuit & over load protection complete all as specified and as directed.
10
-
-
... More
Material and labour for concealed sub main wiring in replacement with 6 Sqmm single core (Two run) FRLS PVC insulated multistrand copper conductor drawn through and including PVC conduit 25mm dia (heavy duty) on independent circuit from DB and including one run 4 Sqmm FRLS PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, junction box, terminal box, tee, bend etc. and including taking down old sub main wiring of PVC insulated aluminium conductor cable two single core 6 Sqmm or any size including GI earth wire from conduit including taking out/down rusted conduit, including making good disturbed surfaces of walls/ceiling etc. complete all as specified and as directed by Engineer-in-charge.
Note :-Two run of 6 Sq mm, one run of 4 sqmm copper wire and one run conduit shall be measured as one length.
120
-
-
... More
Material and labour for concealed sub main wiring in replacement with 10 Sqmm single core (Four run) FRLS PVC insulated multistrand copper conductor drawn through and including PVC conduit 32mm dia (heavy duty) on independent circuit from DB and including one run 6 Sqmm FRLS PVC insulated unsheathed multi strand copper conductor continues as earth wire connected to earth dolly etc. including all fitting arrangement i.e. PVC clamp, rawl plug, screw, junction box, terminal box, tee, bend etc. and including taking down old sub main wiring of PVC insulated aluminium conductor cable two single core 10 Sqmm or any size including GI earth wire from conduit including taking out/down rusted conduit, including making good disturbed surfaces of walls/ceiling etc. complete all as specified and as directed by Engineer-in-charge.
Note :-Four run of 10 Sq mm, one run of 6 sqmm copper wire and one run conduit shall be measured as one length.
30
-
-
... More
Supply, laying and testing in replacement of Cable of size 10 Sqmm, 2 core, 1100 Volt grade heavy duty with PVC insulated, stranded aluminium conductor served with an inner sheathening of PVC tape and over all PVC Sheathed stranded conductor in service connection suspended by insulating hangers not less than 1 metre apart including 4 mm GI suspended wire and necessary connections and suitable size of thimbling complete all as specified and as directed by Engineer-in-charge.
150
-
-
... More
Material and labour for Earthing complete with galvanised iron earth plate electrode of size 60 x 60 x 0.60 cm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI wire 4 mm (upto test point from earth plate and test point to DB) by means of GI bolts/nuts/washers and including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI light grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, CI cover and frame, PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in earthing pit including necessary form work, excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I.
Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
4
-
-
... More
S & F LED building security light fitting 25 watt with epoxy powder coated sheet aluminium housing, with epoxy powder coated CRCA sheet steel grey tray, clear acrylic cover and accessories complete incl street light bracket made out of 25 mm dia GI light grade pipe 0.6 mtr long complete with 2 sets of FI clamps made out of 30x5 MS flat & nuts, bolts & washer including painting to clamp with two coats of aluminium silver paint over a coat of primer after taking down old u/s one. Make of fitting Bajaj Cat Pt No BRLEP 25 W LED or equivallent in any of the make mentioned in list of products.
2
-
-
... More
Material & Labour for dismantling the ceiling/Exhaust fan of any make/model for complete overhauling such as cleaning the blades and louver with detergent powder inspecting the fan bearing/bush, cleaning with diesel/kerosene oil, greasing/oiling complete all as specified and as directed by Engineer-in- Charge. Note :- All defective/ unserviceable parts/items like bush, bearing, condenser etc. shall be measured and paid separetaly under appropriate items mentioned here-in-after.
800
-
-
... More
Supply and Fixing in replacement rubber reel including suitable size of bolt, nut and safety pin for ceiling fan of any make/size/model complete all as specified and as directed by Engineer-in- Charge.
500
-
-
... More
Supply and Fixing in replacement ball bearing of No. 6201 suitable for ceiling fan complete all as specified and as directed by Engineer-in- Charge.
Make :- SKF/NBC/INA/FAG/NSK
40
-
-
... More
Supply and Fixing in replacement ball bearing of No. 6202 suitable for ceiling fan complete all as specified and as directed by Engineer-in- Charge.
Make :- SKF/NBC/INA/FAG/NSK
30
-
-
... More
Supply and Fixing in replacement ball bearing of No. 6203 suitable for ceiling fan complete all as specified and as directed by Engineer-in- Charge.
Make :- SKF/NBC/INA/FAG/NSK
10
-
-
... More
Supply and fixing in replacement capacitor/condenser of size 2.5 Mfd for any fan motor/exhaust fan motor including making necessary connections and testing complete all as directed by Engineer-in-charge.
Make :- Tesla/Asian/Epcos/MTC/ Usha/ Siemens
300
-
-
... More
Supply and fixing in replacement capacitor/condenser of size 4 Mfd for any fan motor/exhaust fan motor including making necessary connections and testing complete all as directed by Engineer-in-charge.
Make :- Tesla/Asian/Epcos/MTC/ Usha/ Siemens
30
-
-
... More
Supply and fixing in replacement MCCB 4-pole 415 Volt, 250 Amp, short circuit rupturing capacity 25 KA,thermal magnetic trip setting 80-100%. Icu-100% Ics confirming to IEC-947,IS-13947, including nuts, bolts and washers etc. and making incoming and outgoing connections and testing complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fixing in replacement MCCB 4-pole 415 Volt, 200 Amp, short circuit rupturing capacity 25 KA,thermal magnetic trip setting 80-100%. Icu-100% Ics confirming to IEC-947,IS-13947, including nuts, bolts and washers etc. and making incoming and outgoing connections and testing complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
Supply and fixing in replacement MCCB 4-pole 415 Volt, 100 Amp, short circuit rupturing capacity 25 KA,thermal magnetic trip setting 80-100%. Icu-100% Ics confirming to IEC-947,IS-13947, including nuts, bolts and washers etc. and making incoming and outgoing connections and testing complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
S & F in repair door hinges of sheet metal cabinet including necessary welding and painting of cabinet of CRCA sheet of size 660 x 660 x 200mm with two coats of synthetic enamel paint over and including a coat of red oxide primer complete all as specified and directed by Engineer-in-charge.
40
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements