Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date31 Aug 2024
Closing Date26 Sep 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per serial item No. 1 here in before but with the following fittings & fixures :-

3

-

-

... More
(i) MCCB, 4 pole , 35 KA , 200 Amps -01 No ( Incomming) (ii) MCCB , 4 pole , 10 KA, 63 Amps -04 No (Out going) (iii) Digital voltmeter of size 96 x96 mm ( 0-500v) with built in selector switch (iv) Digital Ameter of size 96 x96 mm ( 0-150A) with built in selector switch (V) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv) (vi) Solid aluminium bus bar 400 Amp for 3 phase and 200 Amp for neutral (vii) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge

-

-

-

... More
All as per serial item No. 1 here in before but with the following fittings & fixures :-

2

-

-

... More
(i) MCCB, 4 pole , 35 KA , 200 Amps -01 No ( Incomming) (ii) MCCB , 4 pole , 10 KA, 63 Amps -06 No (Out going) (iii) Digital voltmeter of size 96 x96 mm ( 0-500v) with built in selector switch (iv) Digital Ameter of size 96 x96 mm ( 0-150A) with built in selector switch (V) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv) (vi) Solid aluminium bus bar 400 Amp for 3 phase and 200 Amp for neutral (vii) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge

-

-

-

... More
All as per serial item No. 1 here in before but with the following fittings & fixures :-

1

-

-

... More
(i) MCCB, 4 pole , 35 KA , 315 Amps -01 No ( Incomming) (ii) MCCB , 4 pole , 16 KA, 160 Amps -03 No (Out going) (iii) MCCB , 4 pole , 10 KA, 63 Amps -04 No (Out going) Timer switch complete with contactor, timer, MCB etc - 01 Set (iv) Digital voltmeter of size 96 x96 mm ( 0-500v) with built in selector switch (v) Digital Ameter of size 96 x96 mm ( 0-150A) with built in selector switch (vi) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv) (vi) Solid aluminium bus bar 500 Amp for 3 phase and 250 Amp for neutral (vii) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge

-

-

-

... More
All as per serial item No. 1 here in before but with the following fittings & fixures :-

1

-

-

... More
(i) MCCB, 4 pole , 35 KA , 250 Amps -01 No ( Incomming) (ii) MCCB , 4 pole , 16 KA, 160 Amps -02 No (Out going) (iii) MCCB , 4 pole , 10 KA, 63 Amps -06 No (Out going) Timer switch complete with contactor, timer, MCB etc - 01 Set (iv) Digital voltmeter of size 96 x96 mm ( 0-500v) with built in selector switch (v) Digital Ameter of size 96 x96 mm ( 0-150A) with built in selector switch (vi) Indication Lamp 22.5 mm dia LED type 240Volts AC to show three phase availability- 01 set. (Make for indication lamp : L&T/Secure/Conserv) (vi) Solid aluminium bus bar 500 Amp for 3 phase and 250 Amp for neutral (vii) PCC and block Mesonry work for grouting of panel complete all as specified and directed by Engg-in-charge

-

-

-

... More
Supply installation testing and commissioning in repair APFC PANEL 50KVAR (15KVAR x 2, 10KVAR x 2) Automatic power factor correction panel consisting of following 125A 433V 3P 50Hz 16KA Fixed Manual Type Moulded Case circuit breaker (MCCB) with thermal magnetic release for overload and magnetic shortcircuit (TMD) as Incomer for APFC. APFC RVT Relay (RVT) 15 KVAR metallised polypropelen capacitor bank 10KVAR metallised polypropelen capacitor bank Capacitor duty contactor for switching on & switching off 15 KVAR capacitor bank (MNx 32) Capacitor duty contactor for switching on & switching off 10KVAR capacitor bank (MNx 25) 32A,3P,10KA MCB for protection of 30KVAR Capacitor Bank 25A,3P,10KA MCB for protection of 10KVAR Capacitor Bank Note :- (i) The Quoted rate shall include construction of foundation/plinth of PCC 1:2:4 type B-2 all as per manufacturer's instruction and standard drawing. Height of foundation shall be 800mm out of which 500mm shall be above ground level

1

-

-

... More
M&L painting old surfaces of Feeder Pillar boxes / LT panels of any sizes at site with one coats of epoxy based paint DANCOT/Asian make shade / tint as approved including preparation of surfaces, cleaning rusted portion complete all as specified and directed.

35

-

-

... More
M&L for earthing complete with GI earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.50 Mtr below ground level. The earth plate to be connetced with earth lead of 25x4 mm GI strip all as shown in para no 4 the earthing test point all as specified and directd.The GI earthing strip to be protected by galvanised iron pipe 40 mm bore (medium grade) up to ground level and there after with 40mm dia HDPE pipe up to test point. Earthing shall be include with providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) up to 90 cm all around earth plate further filled with 60 cm thick Tibba sand and 2nd layer with 30 cm of Magnesium sulphate powder (compact thickness ) , 3rd layer with tibba sand up to the ground level. Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded , crushed stone aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work all as specified and directed.

16

-

-

... More
M&L repair to LT Panel board indoor / outdoor type of any capacity having 1 No Incomer & out going MCCB's up to 6 Nos (Max) by carrying out the following works:- (i) Cleaning incomer switches, bus bar & out going switches etc thoroughly by using blower. (ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing. (iii) Replacement of Indicator lamps, Volt meter, Amps meter, VSS, ASS as required as per existing. (iv)Replacement of Incoming / out going switches as per existing make & model. (v) Replacement of control wiring with suitable size as per existing copper wire (vi) Making the locking arrangement functional including welding if required (vii) Replacement of MV danger board (viii) Making proper connections for out going / incoming cable by providing suitable thimble as required. Note: MCCB's, Indictor lamps, Volt meter, Amps meter, Voltage Selector Switch / Ampere Selector Switch shall be measured and paid separatly as 'Supply only' against respective item of this Schedule..

18

-

-

... More
Supply only following fixtures / fittings for replacement in LT Panel boards:-

-

-

-

... More
Supply only MCCB, 36 KA, 4 pole, 400A.

2

-

-

... More
Supply only MCCB, 36 KA, 4 pole, 200A .

2

-

-

... More
Supply only MCCB, 36 KA, 4 pole, 160A .

6

-

-

... More
Supply only MCCB, 16 KA, 3 pole, 125A .

6

-

-

... More
Supply only MCCB, 16 KA, 3 pole, 100A .

6

-

-

... More
Supply only Change over switch 4 pole 415 Volt 100 Amps.

4

-

-

... More
Supply only Change over switch 4 pole 415 Volt 200 Amps.

2

-

-

... More
Supply only Digital volt meter 0-500 Volt, with selector switch of size 96X 96 mm Square flush type .

6

-

-

... More
Supply only Digital ammeter 0-100 amp including CT 100/5 amps and selector switch complete .

6

-

-

... More
M&L for repair to Automatic Power Factor Correction (APFC) Panel of capacity upto 50 KVAR by replacing unserviceable parts, controlling wiring etc and including testing complete after repairing all as specified and directed. Note :- (i) Spare parts required at site for repaired shall be measured and paid separately . (ii) Mulltistranded copper wires upto 6 Sqmm, Single Core and lugs/thimbles as per site requirement to be replaced in repairs by the contractor shall deemed to be included in the unit quoted rate and other spares as required will be measured and paid separately.

4

-

-

... More
All as per ser No 11 above but for capacity from 50 KVAR to 160 KVAR

3

-

-

... More
All as per ser No 11 above here in before but for capacity above160 KVAR to 250 KVAR

2

-

-

... More
Supply only Standard Duty Capacitors Cylindrical type suitable for APFC Panel of 5 KVA rating, as per existing make and model complete all as specified and as directed .

4

-

-

... More
Supply only Standard Duty Capacitors Cylindrical type suitable for APFC Panel of 10 KVA rating, as per existing make and model complete all as specified and as directed .

6

-

-

... More
Supply only Standard Duty Capacitors Cylindrical type suitable for APFC Panel of 15 KVA rating, as per existing make and model complete all as specified and as directed .

5

-

-

... More
Supply only Standard Duty Capacitors Cylindrical type suitable for APFC Panel of 25 KVA rating, as per existing make and model complete all as specified and as directed .

6

-

-

... More
Supply only Standard Duty Capacitors Cylindrical type suitable for APFC Panel of 50 KVA rating, as per existing make and model complete all as specified and as directed .

4

-

-

... More
Supply only APFC Controller - 1 CT input, upto 6 stages of required size , Single CT input 1/5 Amps and Voltage Input 415V for AFPC Panel as per existing complete all as specified and as directed.

4

-

-

... More
Supply only APFC Controller - 1 CT input, upto 12 stages of required size , Single CT input 1/5 Amps and Voltage Input 415V for AFPC Panel as per existing complete all as specified and as directed.

2

-

-

... More
Supply only 3 Pole Power Contactors, MNX type, Aux. Contacts 1 NO and 1 NC of rating 32 Amps, for AFPC Panel as per existing make and model complete all as specified and directed.

4

-

-

... More
Supply only 3 Pole Power Contactors, MNX type, Aux. Contacts 1 NO and 1 NC of rating 18 Amps, for AFPC Panel as per site requirement all as specified and directed. Make : L&T, Model : MNX 22 or equivalent in Havells/ Siemens/Indoasian.

6

-

-

... More
Supply only MCB TPN 'C' Series upto capacity of 32 Amps as per site requirement all as specified and directed.

8

-

-

... More
Taking out old underground LT Cable of size 25 Sqmm to 120 Sqmm of 3.5 core from LT Panels trenches / floors / wall/ pipe / pole / including taking out loop from trenches upto 1.0 mtrs depth, cutting the faulty end of cable and refixing the cable in original position by using flat aluminium sockets/ thimble/ and insulating the all nacked wires of any size including making connection with MCCB's/ Switches complete all as directed by Engineer-in-Charge. Note : Cost for Exacavation for taking out LT cable , returning and filling shall deemed to be included in the unit quoted rate .

60

-

-

... More
All as per item No. 24 above but 150 Sqmm to 400 Sqmm 3.5 core

30

-

-

... More
Supply and fixing in replacement Aluminium bus bar of any size with aluminium thimbles nuts, bolts, washers etc complete all as specified and as directed. Note- Aluminium bus bar strips shall be covered with PVC insulation tape of red , yellow, blue and black colour for proper colour coding as per IE rules. Cost of nuts ,bolts, washers, insulation etc. shall be inclusive in the quoted rates.

60

-

-

... More
Surface dressing n exc 15 cm deep including clearing away all grass vegetation, saplings, shrubs, brushwood, undergrowth, roots, leveling & water spreading and removing rubbish, upto a distance of 50 meters outside the periphery of the LT panel area under clearance all as directed .

1200

-

-

... More
Excavation in any type of soil in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for cable trenches for laying of cable / pipes etc.and getting out in hard / dense soil including taking out old bricks complete all as specified and directed. Note:- (I)Old unservicable bricks shall be sold to contractor under Sch of credit. (ii) Serviceable brickss stacked for reuse.

621.27

-

-

... More
Returning, filling in trenches including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and directed.

358.53

-

-

... More
Removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed .

262.74

-

-

... More
Material and labour sand cushioning using dry clean sand (Tibba Sand) for protection of underground cable, consolidated and compacted complete all as specified and directed.

186.38

-

-

... More
Material and labour well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and directed .

11.04

-

-

... More
Laying only serviceable old bricks for cable protection obtained from item no 28 above, complete all as specified and as directed.

7.36

-

-

... More
Taking out following defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor of any Cross sectional area from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable complete all as specified and directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item is also includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.

3835

-

-

... More
Supply and laying XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable Cross sectional area 16 Sqmm, 4 core in trenches or fixed to wall / passing through pipe / pole and testing compete all as specified and directed by Engineer-in-charge Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid for separately,

300

-

-

... More
All as per description of item No. 35 here-in-before but Cross sectional area 25 sq mm, 4 core.

400

-

-

... More
All as per description of item No.35 here-in-before but Cross sectional area 35 sq mm, 3.5 core

500

-

-

... More
All as per description of item No.35 here-in-before but Cross sectional area 50 sq mm, 3.5 core .

600

-

-

... More
All as per description of item No.35 here-in-before but Cross sectional area 70 sq mm, 3.5 core

600

-

-

... More
All as per description of item No.35 here-in-before but Cross sectional area 95 sq mm, 3.5 core

480

-

-

... More
All as per description of item No.35 here-in-before but Cross sectional area 120 sq mm, 3.5 core

600

-

-

... More
All as per description of item No.35 here-in-before but Cross sectional area 150 sq mm, 3.5 core

355

-

-

... More
Supplying and laying INCLUIDING BORING OF HOLES as in repairs 80 mm bore GI tubing light grade incl all accessories for passing of cables for mechanical proctection, laid under Plinth / Floors/ Paths Culverts or fixed on wall or concealed in wall / floor or along poles or as street light poles or as street light mounting bracket with complete accessories such as bends / sockets / reducers / saddles incl necessary threading / drilling works all as specified and directed.

30

-

-

... More
All as per description of item No. 44 above but Cross section 4O mm dia.

60

-

-

... More
Material and labour for boring in soft/ loose soil at a deapth not less than 1.5 metre under road/PTT/pavement/ Hard standing etc by usingof ultra sounding technique and mechinery equipments suitable for and including laying HDPE pipe nominal outer dia 150 mm PE 80 PN- 6 ISI marked all as per IS 4984/2016 including fittings complete without damaging the surface complete all as specified and directed by Engineer in charge Note :- (i) Location of boring holes shall be decide by the Enginer- in- charge as per requirement , nothing extra shall be payable on account of variation in length of crossing of road /PTT/pavement /Hardstanding etc. (ii) During boring soil strata may be changed, hence nothing extra shall be paid to the contractor for boring of holes through different type of soil. Tender is hereby advised to keep in mind this aspect while quoting his rates."

20

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.