If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 80,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_686013_1Tender No
8495/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Taking down carefully by unscrewing from boards / outlet boxes, light fittings and fixtures such as tube light fittings, bulk head fittings, mirror light, bldg sec light etc for re use at site or carrying to the store ( To be measured only when found serviceable in all respects complete for re use.) complete all as specified and directed.
40
-
-
M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed in and including non metallic rigid PVC concealed conduit 20 mm dia or higher complete with all PVC conduit accessories such as socket, elbow, junction box, bell mouth, reducer, bend and flexible conduit etc./ fittings ISI marked and sunk type pressed steel anodised terminal box with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including one green colour cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by of following:-
-
-
-
All as per item no 5.00 above but One light point/bell point controlled by one way 5 Amps single pole switch, complete all as specified and directed.
320
-
-
All as per item no 5.00 above but One ceiling fan/exhaust fan point controlled by one way 5 Amps single pole switch, complete all as specified and directed.
120
-
-
All as per item no 5.00 above but One 5 pin 5 Amps socket outlet on same board with other switch, complete all as specified and directed.
80
-
-
All as per item no 5.00 above but One 5 Pin 5 Amps socket outlet on independent board with other switch, complete all as specified and directed.
130
-
-
All as per item no 5.00 above but One light point controlled by two, 2-way switches complete all as specified and directed.
14
-
-
All as per item no 5.00 above but with 2.5 Sqmm single core multi stranded PVC insulated unsheathed (FRLS) cable for 15 Amp socket outlet on independent board, complete all as specified and directed.
75
-
-
M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed in and including PVC casing & caping with all PVC casing caping accessories and sunk type pressed steel anodised terminal box with bakelite laminated sheet top cover 3 mm thick, brass screws and cup washers including one green colour cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by of following:-
-
-
-
All as per item no 7.00 above but One light point/bell point controlled by one way 5 Amps single pole switch, complete all as specified and directed.
40
-
-
All as per item no 7.00 above but One ceiling fan/exhaust fan point controlled by one way 5 Amps single pole switch, complete all as specified and directed.
10
-
-
All as per item no 7.00 above but One 5 pin 5 Amps socket outlet on same board with other switch, complete all as specified and directed.
10
-
-
All as per item no 7.00 above but One 5 Pin 5 Amps socket outlet on independent board with other switch, complete all as specified and directed.
10
-
-
All as per item no 7.00 above but with 2.5 Sqmm single core multistranded unsheathed (FRLS) cable for 15 Amp socket outlet on independent board, complete all as specified and directed.
10
-
-
M&L for point wiring with 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed cable in and including PVC rigid non metallic conduit medium grade not less than 20mm dia ISI marked and fittings and accessories concealed in walls/roof/ ceiling with suitable size of sunk type pressed steel modular terminal box and modular white cover plate with frame of suitable module as per site requirements for mounting of modular switches, sockets, fan regulator etc and one green colour cable of 1.5 Sqmm. (nominal area) single core PVC insulated 1100 Volts, grade multi stranded FRLS copper conductor unsheathed as earth wire up to common earth and connected to earth for the following, complete all as specified and directed:-
-
-
-
All as per item no 9.00 above but One light point/bell point controlled by one way 5 Amps single pole switch complete all as specified and directed.
120
-
-
All as per item no 9.00 above but One ceiling fan/exhaust fan point controlled by one way 5 Amps single pole switch complete all as specified and directed.
40
-
-
All as per item no 9.00 above but One 5 pin 5 Amps socket outlet on same board with other switch complete all as specified and directed.
35
-
-
All as per item no 9.00 above but One 5 Pin 5 Amps socket outlet on independent board with other switch complete all as specified and directed.
35
-
-
All as per item no 9.00 above but One light point controlled by two, 2-way switches complete all as specified and directed.
4
-
-
All as per item no 9.00 above but with 2.5 Sqmm cross sectional area electric cable for 15 Amp socket outlet on independent board, complete all as specified and directed.
35
-
-
S & F of switch piano type, flush button single pole, one way 5 Amps, complete all as specified and directed.
700
-
-
S & F of switch piano flush type, 5 Amp , 240 volt , single pole, two way switch, complete all as specified and directed.
28
-
-
S & F of switch piano flush type 15 amps, single pole one way 240 volts complete all as specified and directed.
85
-
-
S & F of switch bell push, flush type, 5 Amp, complete all as specified and directed.
20
-
-
S & F of socket outlet 5 Amps, 5 Pin, flush type, complete all as specified and directed.
230
-
-
S & F of socket out let 2 in 1,multipurpose 3 pin 15/16 Amp flush type complete all, as specified & directed.
85
-
-
S & F stepped type (switch type) electronic ceiling fan regulator flush type, AC, 230 volts , complete all as specified and directed.
105
-
-
S&F of modular switch 1 way 6/10Amp , 1 module, complete all as specified and directed.
225
-
-
S&F of modular switch 1 way 16Amp, 1 module, complete all as specified and directed.
35
-
-
S&F of modular switch 2 way 6 Amp, 1 module complete all as specfied and directed.
8
-
-
S&F of modular bell push, 6 Amp, 1 module, complete all as specified and directed.
5
-
-
S&F of modular socket 6Amp, 2/3 pin combined 2 module complete all as specified and directed.
70
-
-
S&F of modular socket 6Amp/16 Amp, 2/3 pin combined 2 module complete all as specified and directed.
35
-
-
S&F modular stepped type ceiling fan regulator, 230 volt AC, 2 module, complete all as specified and directed.
36
-
-
S & F of ceiling rose,surface type bakelite 65x17.5 mm, three terminals, complete all as specified and directed.
280
-
-
S & F of door bell electric, ding dong type, AC 230 volts, single phase , complete all as specified and directed.
20
-
-
S&F of lamp holder PVC/polycarbonate type with back plate complete all as specified and directed.
80
-
-
S&F in repair LED tube light fitting in acrylic linear tube (1x 18 watt),230V for single LED tube light including 1 x 18 W LED retrofit bar professional CW 6500 K cover channel, bipin holders,LED power driver, connector block, etc complete with all accessories internally prewired and including connecting up with three core flexible copper conductor cable with suitable size for connection of fitting from ceiling rose complete all as specified and directed.
100
-
-
S & F wall mounted decorative luminarie fitting suitable for LED lamp B-22 base incl LED lamp 9 watt B-22 base complete all as specified and directed.
35
-
-
Fixing only serviceable light fitting any type and make obtained from complete all as directed.
40
-
-
S & F in repair LED mirror light fitting, 10 watt, 600 mm length complete with all accessories pre-wired and including connecting up with flexible copper conductor cable with suitable size complete all as specified and directed.
20
-
-
S & F in repair LED light fittings, 10 W bulk head luminaries 230V, 50 Hz complete with all accessories and including connecting up with three core copper conductor cable with suitable size complete all as specified and directed.
20
-
-
S & F in repair testing and commissioning energy saving street light luminaire 35/36/40 watt LED , pressure die cast housing with epoxy powder coated with colour finish and prismatic poly carbonate coverlic cover complete, IP 66 protection incl connecting with three core copper flexible wire from ceiling rose to connector of light fitting complete all as specified and directed.
10
-
-
S & F recess mounted LED edge lit slim downlight 12 watt round shaped ,die-cast aluminium housing finished in white powder coating incl driver, efficiency 100 Lm/w complete all as specified and directed.
5
-
-
S & F LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
5
-
-
S & F in repair recess mounted 2' x 2' LED luminarie 36 watt, cool day/warm white light with white powder coated CRCA housing with LED driver, efficiencey 100 Lm/w complete all as specified and directed.
8
-
-
S & F in repair street light bracket made of 20 mm GI pipe, 1.2 mtr lenght fixed with two nos of clamp , nut and bolts complete all as specified and directed.
10
-
-
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through and including 25 mm dia PVC non metallic rigid conduits and the conduits accessories incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable, in concealed conduit in wall/ roof/ ceiling, complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length.
85
-
-
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 6 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 6 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length.
80
-
-
M & L for Submain wiring with two single core PVC insualated, unseathed, FRLS, 1100 volts grade 4 Sqmm multi stranded copper conductor cable drawn through existing concealed conduit incl one run of green colour earth continuity conductor with 4 Sqmm multi stranded copper conductor cable complete all as specified and directed. Note : - Two run of single core cable, one run of earth continuity conductor shall be measured as one unit length.
90
-
-
S & F of MCB SP, 240 volt, 6 Amp to 32 Amp capacity, 10 KA, 'C' Type instantaneous tripping complete all as specified and directed.
120
-
-
S & F of MCB SPN 10 to 40 Amp capacity, 10KA , 'C' Type instantaneous tripping complete all as specified and directed.
5
-
-
S & F of MCB SPN 63 Amp capacity, 10 KA , 'C' Type instantaneous tripping complete all as specified and directed.
6
-
-
S & F of MCB TPN 63 Amp capacity,415 volt 10 KA , 'C' Type instantaneous tripping complete all as specified and directed.
4
-
-
S & F of MCB TPN 100 Amp capacity, 415 volt, 10 KA , 'C' Type instantaneous tripping complete all as specified and directed.
1
-
-
S&F MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 8 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed.
Note : MCB DB and MCB will be the same make.
10
-
-
S&F MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 12 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. Note : MCB DB and MCB will be the same make.
3
-
-
S&F MCB distribution board single pole & neutral with 200 Amps rated bus bar, double door, IP-43, DB's made out of CRCA sheet steel enclosure, recessed type, factory made powder coated, 4 way, 240 volts suitable for housing MCB's and isolator's complete in all fixing material/accessories etc complete all as specified and directed. Note : MCB DB and MCB will be the same make.
4
-
-
S&F of MCB distribution board triple pole & neutral IP-43 double door metal, 4 way ,415 volt made out of CRCA sheet steel , factory made powder coated with insulated bus bars , shrouded neutral bars, earth bars , made out of sheet steel enclosure, recessed type, factory made powder coated suitable for housing MCB's complete all as specified and directed. Note: MCB DB and MCB SP/SPN will be the same make.
4
-
-
M & L for earthling complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to GI lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electric plate No 3 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, medium grade including excavation & earth work in any type of soil & disposal of soi, providing alternate layers of charcoal and common salt, constr of PCC earth chamber in mix 1:3:6 type C-1 with 40mm thick RCC 1:2:4 type B-1 cover with handle made out oof 8mm dia bars, watering arrangement with funnel & wire mesh, complete all as specified and directed. Note. The unit rate includes for protection pipe and GI wire 4.00 mm from top of earth plate up to 7.5 meter above ground level.
6
-
-
S & F in repair single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole 20 Amp MCB SP `C' type instantaneous for geyser & AC complete all as specified and directed.
10
-
-
M&L for Cleaning of over head tank, (staging from 6 meter to 18 Meter) (inside) by scraping with hard steel wire brushes and descaling of over head tank (reservoir), brooming slit and other deposit from inner side (bottom of dome ) collecting and taking out the same with the help of manual labour and removing and deposited to a distance not exceeding 50 m all as directed and making OHR complete clean and washing properly with bleaching mixed water and applying two coats of thick quick drying lime wash on entire surface (inner) top and bottom including writing date of cleaning with white paint on black painted surface of back ground at two places and painting of inner steel ladder of tank with one coat of synthetic enamel paint including painting to external surface of existing pipes (washout, overflow, delivery and inlet lines as per colour code), OHR outer surface with two coat weather proof paint and all types of valves in the perimeter of OHTs all as specified and directed for the following :-
-
-
-
All as per item no 52.00 above but Over Head tank of capacity 100000 Gallon
1
-
-
All as per item no 52.00 above but Over Head tank of capacity 50000 Gallon
3
-
-
All as per item no 52.00 above but Over Head tank of capacity 40000 Gallon
1
-
-
All as per item no 52.00 above but Over Head tank of capacity 35000 Gallon
1
-
-
All as per item no 52.00 above but Over Head tank of capacity 15000 Gallon
2
-
-
All as per item no 52.00 above but Over Head tank of capacity 5000 Gallons
1
-
-
Cleaning and upkeeping of sub station area, all power houses, water supply installations including in Ajmer surrounding area of LT Panel/Bus Bar/Feeder pillar box and clearing away all grass vegetation, sapplings,shrubs,bushes under growth roots and trees not exc 30 cm girth ( Measured 1 mtr above the ground level) and removing of rubbish to a distance of 50 mtr out side periphary complete all as specified and directed.
300
-
-
M & L for taking out sludge /foreign material/silt/vegetation /mud from the clear water underground sump of following capacity dewatering through drain out channel/ pipe with valve /by using suitable pump set/suitable T&P/manpower with removing residual water and cleaning the wall with the help of blade /scrapper/wire brush using disinfection material after repairing cracks/depressions/cavities by filling cement mortar CM1:3 mixed with liquid water proofing admixture/best quality putty after applying cement slurry mixed with liquid water proofing admixture to entire satisfaction of preparation of old surface and applying one coat of lime wash in inner surface including removing the sludge/slit/foreign material by using suitable T&P/man power to a distance 50 to 100 meters and depositing where directed as and when required basis and writing date of cleaning with paint capital letter of 80mm stencil alongwith the capacity of the tank complete all as specified and directed for the fwg:-
-
-
-
All as per item no 54.00 above but Under Ground Sump Capacity 4,37,000 Gallons
1
-
-
All as per item no 54.00 above but Under Ground Sump Capacity 3,00,000 Gallons
1
-
-
All as per item no 54.00 above but Under Ground Sump Capacity 20,000 Gallons
1
-
-
All as per item no 54.00 above but Semi Under Ground Sump Capacity 40,000 Gallons
1
-
-
All as per item no 54.00 above but Under Ground Sump Capacity 5,000 Gallons
1
-
-
All as per item no 54.00 above but Under Ground Sump Capacity 25,000 Gallons
1
-
-
S & F in replacement of AFO Fireball-Fire Extinguisher Plastic Ball Oval Shaped ,Quick Fire off, 1.5 kg dimensions 22 x 22 x 22 cm complete all as specified and directed.
10
-
-
M&L for Disconnecting, dismantling of solar water heating system including all water and electric connection of capcity 500 ltrs per day and re-fixing the same in existing position after the following repairs and testing complete:-.
(a) Replacement of the worn out/missing nuts bolts , washers, unions,socketsflanges and screw etc complete.
(b) Descaling/desludging the hot water pipes and normal water by using appropriate chemicals/Anti corrosive/Anti scaling agent solution, cleaning and washing all copper tube & water circulated pipes of heat convetor sets throughly cleaning the complete solar panel of making the tube scale free and reassemling the panel.
(c) Cleaning hot and cold water tanks, removing sludge and scale from the tank manually using suitable chemicals complete.
(d) Repair of collector fins incl required welding works etc complete.
(e) Testing on completion after Repair work and making the Solar Water Heater functional in each aspects.
Note:- The work shall be carried out by the company technician. The Spare parts such as Solar energy collector panel, toughned glass, rubber gasket, hose pipe, insulation for hot water pipe, heating element, thermostat, Water Storage tank, gate valve/float valve, MS Clamp shall be measured & paid separately under respective items.
10
-
-
All as per descrition of serial item No 56.00 here-in-before but of capacity 300 ltrs per day
2
-
-
All as per descrition of serial item No 56.00 here-in-before but of capacity 100/200 ltrs per day
4
-
-
Supply and installation in replacement of complete one solar energy collector panel (FPC) A Type (Size: 1860mm x 1240mm x 100mm) made of aluminium body with toughened glass complete with copper fins made of canandian technologies undercoat nickle including all accessories capable to heat 100 Litre water per day suitable to be fitted for 500 LPD, 300 LPD & 100 LPD Solar water heating system complete all IS 12933 Part-1 as specified and directed.
12
-
-
S&F in replacement of Solar panel toughened/texture glass (1m×2m) or equivalent size as of existing having thickness 3.2 mm all as existing model of Solar panel system complete all as specified and directed.
8
-
-
S&F in replacement of Rubber gaskets made out of fine rubber for Solar panel complete to make system air tight dust and water leak proof complete all as specified and directed.
50
-
-
S&F hose pipe 1" (25 mm) inner dia for hot/cold water for solar system of suitable length as existing size complete with 02 Nos clamps of required size complete all as directed.
10
-
-
M&L For insulation of hot water pipe with glass wool and covering with alluminium sheet cladding 25 gauge for 20/15 mm bore GI pipe complete all as directed by Engineer-in-charge
50
-
-
S&F in repairs heating element for solar water heater of wattage 3.0 KW operating on 240 volts AC complete as per site requirement all as specified and directed.
30
-
-
S&F in repairs thermostat for solar water heater of wattage 3.0 KW operating on 240 volts AC complete all as specified and directed.
30
-
-
S & F in repair white colour rotational moulded polyethylene (HDPE) water storage tanks of 500 Ltrs capacity (cylindrical vertical with closed top) hoisted, double layer, ISI marked hoisted and fixed in position complete all as specified and directed.
NOTE :- (i) The unit rate quoted by tenderer shall be deemed to insulate water tank with GI pipe medium grade 10cm long projected inside and outside of tank with bore suitable for inlet and outlet, GI pipe 20mm bore medium grade projecting 10cm inside and outside of the tank for over flow, GI pipe 20mm bore medium grade projected 10cm inside and outside of tank for vent & mosquito cover for vent/overflow pipe.
5
-
-
S&F in repairs ball brass valves high pressure with polythene float and fit nut complete screwed for iron pipe or brass ferrule and fixed of size 20 mm dia complete all as specified and as directed.
10
-
-
S&F in repairs 20mm bore gun metal, globe or gate valve with iron wheel head screwed both ends for iron pipes and fixed all as directed.
15
-
-
S&F in repair of MS clamp for existing size of hose pipe complete all as specified and directed.
20
-
-
S&F in repair of panel flange Rubber gasket Fine Rubber complete all as specified and directed.
20
-
-
S&F mild steel water tubing 20 mm dia galvanised medium grade including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors including testing complete all as specified and as directed.
40
-
-
S&F mild steel water tubing 15 mm dia galvanised medium grade including all fittings (such as bends, tees, short pieces connectors, elbows, reducers, unions, sockets etc) and fixed to walls/ceilings/ laid on floors including testing complete all as specified and as directed.
40
-
-
Painting of Solar Staging System , solar panel frame , hot water tank frame (one coat) one finishing coat of synthetic enamel paint complete all as specified and directed.
20
-
-
S&F aluminium strip in replacement 25x3.15 mm with saddles and fixing screws etc for roof conductor and down conductor above ground as earth continuity conductor or main earthing lead complete all as specified and directed.
150
-
-
S&F in repair GI strip 32x6 mm as earthing lead laid in ground , fixed to wall or any other indicated situation for earthing etc as required complete all as specified and directed.
50
-
-
S&F in repair earth continuity conductor or main earthing lead fixed to wall, batten or recess or chases or buried to poles or any other indicated situation for earthing etc as required but 4mm galvanised iron strip complete all as specified & directed.
150
-
-
S&F in repair air termination single pointed aluminium rod 12mm dia and 300mm long complete all as specified & directed.
30
-
-
S & F in replacement terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screws including 3 Nos 8mm dia 25mm long hex head screw complete all as specified and directed.
10
-
-
M&L for earthing complete with galvanized steei earth plate electrode 60cm X 60cmx 6-7mm thick, burried directly in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of plate not less than 1.5 metre below normal ground level and connected to galvanized strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm ’bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and directed.
51
-
-
Supply, laying, Jointing connecting in replacement of LT UG cable XLPE insulated,PVC bedded galvanised steel strip or wire armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area 10 sqmm 2 core laid in trenches / on poles / walls / in ducts / passing through pipes and including necessary cable lugs, bolts, nuts and washers complete all as specified and directed.
100
-
-
All as per serial item No. 78.00 above but for 06 Sqmm 2 core complete all as specified and directed..
100
-
-
All as per serial item No. 78.00 above but for 16 Sqmm 4 core complete all as specified and directed.
80
-
-
All as per serial item No. 78.00 above but for 25 Sqmm 4 core complete all as specified and directed.
100
-
-
All as per serial item No. 78.00 above but for 35 Sqmm 3.5 core complete all as specified and directed.
70
-
-
Excavating in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. or for cable laying or not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed.
86.4
-
-
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed.
53.86
-
-
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed.
32.54
-
-
Supply and spread sand in trenches as sand cushioning to underground cable for protection with dry fine river sand and provide required cover after punning down 18CM will be measured and paid complete all as specified and directed.(Note: Thickness of sand cushion after punning down will be measured and paid.)
25.92
-
-
Supply and laying well burnt sub class ‘B’ bricks (designated 75) locally available best quality, laid dry in trenches for protection of underground cable all as specified and directed.
2.78
-
-
M&L for plain cement concrete (1:3:6) type C1 using 20mm graded crushed stone aggregate in coping of pole, concrete base work, protection of cable complete all as specified and directed.
1.1
-
-
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sq. mm 2 core solid conductor nominal cross section in service connections complete all as specified & directed.
100
-
-
Trimming / cutting of the tree branches / bushes which falls within a clear distance of 3 meter from all sides from the LT over head conductor & within line of conductors, and shifting waste to nearby waste depot & cleaning area complete all as specified and directed.
300
-
-
S&F and M&L New sign board/indicating board/Banner Board/Display board with stand with painting and writing (computerised or hand written) by skilled painter after applying two coat synthetic enamel paint over a primer complete. Content, colour and letter size and board and stand size as approved by complete all as specified and directed.
25
-
-
M&L for painting and writing with paint in all existing machine and equipments SM/MES No/Sr. NO as per the direction given by with skilled painter after applying two coat synthetic enamel paint over a primer complete. Content, colour and letter size as approved by complete all as specified and directed.
350
-
-
Supply, install, testing and commissioning of Bus bar chamber of size 60 cm x 60cm x 40 cm outdoor type suitable for LT 415 volts 3 phase 4 wire system factory made cubical complete materialised dust and vermin proof (protection class IP 54), made out of 3.15mm thick MS sheet (CRCA) including factory made hinged type door both side opening with locking arrangement duly painted with two coats of synthetic enamel paint with powder coated finish over a coat of zinc chrome primer complete all as specified and directed the panel board shall be comprising of the following accessories
Note :- (a) Aluminium bus bar cap 200 Amp - 04 Nos
(b) MCCB four pole with thermal magnetic release adjustable type with breaking capacity 25 KA,100 Amp - 01 No
(c) Digital Voltmeter-96 x 96 mm flush secure Panel mounting type 0-500V with selector switch - 01 No
(d) Digital Amp meter 96 mm X 96 mm flush secure Panel mounting type 0-400 Amps with selector switch with CT - 01 No
(e) RYB neon indicating lamp set of three- 01
3
-
-
S&F in replacement of damaged LT panel section of front/back/side /top and bottom portion of any size MS sheet with new of required size or thickness and fixing on existing LT panel board including necessary bracing/welding work and drilling works including necessary hinges and two coat of sunthetic thick enamel paint over a coat of red oxide primer complete all as specified and directed.
50
-
-
M&L for painting feeder pillar box LT panels of inside, outside and all six sides including all angle iron legs after preparation of old painted surfaces with one coat of synthetic enamel paint of existing colour complete all as specified & directed.
25
-
-
Supply, fabricating , fixing in repair structural mild steel channel angle iron, flat iron and brackets etc for fabrications of cross arms, bracings, supports, D-clamps, stiffeners, eye hooks, bolts, pole clamps and back plates including nuts, bolts and washers, welding bending cold , or hot drilling holes for insulators bolts in any shape or size as indicated or directed and inclusive of one red oxide primer coat ,one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Note:- Insulators to be measured and paid for separately.
10
-
-
Taking out old unserviceable indicating lamp and S&F R Phase LED indicating lamp complete all as specified and directed.
25
-
-
Taking out old unserviceable indicating lamp and S&F Y Phase LED indicating lamp complete all as specified and directed.
25
-
-
Taking out old unserviceable indicating lamp and S&F B Phase LED indicating lamp complete all as specified and directed.
25
-
-
Taking out old unserviceable Digital multi-function meter Supply & fix Digital multi-function meter 96mm x 96mm flush secure panel mounting type -voltage, current, frequency, power factor in 03 line LED backlight display having programmable CT ratio(all as per incommer MCCB) with selector switch complete all as specified and directed.
Make : L & T and equilent
5
-
-
S & F LED Tricolour light rope/strip flexible light silicon made decorative type 230 V AC outdoor type with every piece of cut of required size add driver at every end with proper wire connected from pole box or any point, water resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
750
-
-
Taking down old unsv and fix bracket for street light fittings made out GI pipe of light grade 1.2 m long 40 mm pipe each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm flat iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primer including taking down old unserviceable bracket of any shape and size all as specified and as directed.
30
-
-
Taking down old unsv and Supply and fix bracket for street light fittings made out GI pipe of light grade 1.2 m long 32 mm pipe each bent to shape & size required & fixed to pole with and including flat iron clamps 02 Nos made out of 32 x 6 mm MS flat fixed iron including GI Nuts, bolts and washers and painting of clamps and street light brackets with one coat of aluminium paint over a coat of red oxide primer including taking down old unserviceable bracket of any shape and size all as specified and as directed.
30
-
-
M&L for cleaning, scrapping, preparing of old painted steel/RCC pole/Channel/Bus Bar/Panel and applying one coat of aluminium red oxide primer and two coat of aluminium paint to pole and accessories / fittings whatever fixed on pole including marking/writing pole No on each pole with yellow SE paint with 5cm large bold letters on black background of suitable size at a height of 2m above GL complete all as specified and directed.
80
-
-
Supply, install, testing and commisioning in replacement of U/S all in one integrated LED solar light consists of solar photovoltaic module, battery, battery management system, control electronics, LED driver, microwave sensor, inter-connecting cables and pole mounting piece integrated into the luminaire as a single unit. Solar street light with IP65 ingress protection having a system wattage of with 50Wp high efficiency monocrystalline solar panel, highly efficient MPPT based charge controller and 12.8 V, 23.4 Ah Lithium Ferro Phosphate(LiFePO4) battery with proper battery management system. LED lumen efficacy shall be greater than 140lm/W and LED driver should have 90% efficiency. Typical correlated colour temperature should be 5700K with CRI70. It should have microwave sensor based movement detection and dim level adjustment to effectively extend the working time. AIO should be onsite configurable via a handheld remote. The luminaire should be housed in IK 08 impact resistance certified aluminum with polycarbonate lens cover. The luminaire shall have a specially designed adjustable pole mounting piece for optimal light distribution. LED Wattage not =35 Watts and Lumens not=5000 Lumens, with 5 Years OEM Service warranty, and replacement of unserviceable lights of any type and capacity and including necessary civil work and incl GI pipe Bracket of suitable dia pipe bend to shape of approx length 1.5 Mtr incl 2 no. MS Clamp of flat iron of suitable size complete with nut, bolt, washers all as complete all as specified and directed.
5
-
-
Total in Figures
-
-
-
Quoted Amount in Words
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%