Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Dec 2024
Closing Soon11 Jan 2025
Tender Amount₹ 46,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per item No. 1.00 here-in-before above but of size 70 sq mm. 3½ core

600

-

-

... More
All as per item No. 1.00 here-in-before above but of size 50 sq mm. 3½ core

600

-

-

... More
All as per item No. 1.00 here-in-before above but of size 35 sq mm. 3½ core

300

-

-

... More
All as per item No. 1.00 here-in-before above but of size 25 sq mm. 4core

600

-

-

... More
All as per item No. 1.00 here-in-before above but of size 16 sq mm. 4 core

650

-

-

... More
All as per item No. 1.00 here-in-before above but of size 10 sq mm 2 core

400

-

-

... More
Excavating in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as specified & directed by Engineer-in-Charge.

765

-

-

... More
Excavating in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe/pole etc or soil for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5m in depth and getting out in Soft/disntegrated rock complete all as specified & directed by Engineer-in-Charge.

123

-

-

... More
Excavating in trenches, not exceeding 1.5m wide and exceeding 1.5m but not exceeding 3.00m depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and n exc 1.5 m in depth and getting out in soft/ disintegrated rock complete all as specified & directed by Engineer-in-Charge.

0.4

-

-

... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/loose soil complete all as specified & directed by Engineer-in-Charge.

467

-

-

... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soft/disintegrated rock complete all as specified & directed by Engineer-in-Charge.

73

-

-

... More
Removing excavated material soil/disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engr-in-Charge.

291

-

-

... More
M&L for sand cushioning to underground cable with tibba sand and punning to provide required cover complete all as directed by Engineer-in-charge. Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment.

262

-

-

... More
Taking down the old existing unserviceable stone patti of any description complete all as specified & directed by Engineer-in-charge.

840

-

-

... More
Supply & laying 40 to 50 mm thick roughly hammer dressed Jodhpur stone patti cable cover 25 cm to 30 cm wide and n.exc 60 cm long each laid dry abutting with each other with maximum gap between adjacent slabs n.exc 10 mm complete all as specified & directed by Engineer-in-Charge.

815

-

-

... More
Re-laying only of existing Jodhpur Stone Patti cable cover in Trenches for Under Ground Cable Protection complete all as specified & directed by Engineer-in-Charge. Note :- Serviceable material obtained from taking down shall be re-used.

25

-

-

... More
S&F MCCB 4 Pole 400 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. Note: ICS = ICU 100%

6

-

-

... More
S&F MCCB 4 Pole 250 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. Note: ICS = ICU 100%

8

-

-

... More
S&F MCCB 4 Pole 200 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. Note: ICS = ICU 100%

3

-

-

... More
S&F MCCB 4 Pole 160 Amps, breaking capacity 36 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals complete and connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge. Note: ICS = ICU 100%

11

-

-

... More
S&F MCCB 4 Pole 100 Amps, breaking capacity 16 KA, thermal & magnetic adjustable type, 415 volts with extended copper terminals including taking out existing UNSV / burnt MCCB complete all as specified and directed by Engineer-in-charge. Note: ICS = ICU 100%

12

-

-

... More
S&F MCCB 4 pole 63 Amps rupturing capacity 16 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified & directed by Engineer-in-Charge.

10

-

-

... More
S&F MCB TPN 100 Amps rupturing capacity 10 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCB complete all as specified & directed by Engineer-in-Charge.

13

-

-

... More
S&F MCB TPN 63 Amps rupturing capacity 10 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCB complete all as specified & directed by Engineer-in-Charge.

17

-

-

... More
S&F MCB TPN 32 Amps, 415 volts, rupturing capacity 10 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCB complete all as specified & directed by Engineer-in-Charge.

10

-

-

... More
S&F MCB Single pole and netural rated capacity 40 Amps, 240 volts breaking capacity 10 KA including dismantling/taking down existing unserviceable MCB complete all as specified & directed by Engineer-in-Charge.

20

-

-

... More
M&L for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete 1:3:6, type C1 using 20mm graded aggregate complete all as specified and directed by Engineer-in-Charge.

148

-

-

... More
S&F steel water tubing 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.

124

-

-

... More
S&F steel water tubing 80 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc and including taking down existing pipe of any description complete all as specified & directed by Engineer-in-charge.

24

-

-

... More
Supply, installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii)   Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No (iii)  Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos.

2

-

-

... More
Item NO.33.00 Contd... (iv) Bus bar strips made of Aluminium 400 Amps of suitable size required length – 04 Nos, aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 400/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16 KA with thermal release- - 5 Nos (e) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu

-

-

-

... More
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 250 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii)   Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No (iii)  Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos.

3

-

-

... More
Item NO.34.00 Contd... (iv) Bus bar strips made of Aluminium 400 Amps of suitable size required length – 04 Nos, aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 300/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 160 Amp , breaking capacity 16 KA with thermal release- - 2 Nos (b) MCCB 4 Pole of capacity 100 Amp , breaking capacity 16 KA with thermal release- - 3 Nos (c) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu

-

-

-

... More
Supply,installing, testing and commissioning in repair out door type LT feeder piller box of suitable size, padestal mounted, CPRI type tested factory made totally enclosed, dust and vermin proof (protection class IP-65), double leaf shutter in front and single leaf shutter in rear side made of 3.15 mm thick CRCA sheet, framing with 50 x 50 x 6 mm thick MS angle iron and legs of size 0.5m long . duly fabricated and having proper locking arrangement in both front and rear door with 4 side slanting roof duly projected and painted to both internal and External surfaces with powder coating paint in heat process of sheet and suitable for 415 volts, 50 Hz, 3 phase 4 wire system and comprising with and the panel shall be mounted on 50x50x6mm angle iron stand of height 45cm above ground and 45 cm embeded in ground on suitable PCC foundations. Computer cut shelf adhesive vinyl danger notice plate having conventional symbol of bone & skull be provided complete and including taking down existing etc complete all as specified and as directed. The panel shall consists of following accessories:- Incoming Side (i) MCCB 4P of capacity 400 Amps, 415 Volts, 50 Hz, 3 phase breaking capacity 36 KA with thermal magnetic release - 01 No (ii)   Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. Make- L&T Part No- WL411021OO00 (iii)  Indicator lamp with holder key flush mounted,LED type Red, yellow, blue with toggle switch– 03 Nos. Make L&T- Part No- SIL-00000.

1

-

-

... More
Item NO.35.00 Contd... (iv) Bus bar strips made of Aluminium 600 Amps (Hindalco Make)of size 60 x10mm min 1 Mtr length – 04 Nos aluminium bus bar TPN duly insulated with coloured PVC sleeve as per standard colour code and rigidly mounted on bakelite/DMC insulator bus bar support (Square/round ) insulators of suitable size and good insulation resistance (v) CT 400/5A) -03 Nos OUTGOING:- (a) MCCB 4 Pole of capacity 250 Amp, breaking capacity 36KA with thermal release- - 1 Nos (b) MCCB 4 Pole of capacity 200 Amp , breaking capacity 25KA with thermal release- - 2 Nos (c) MCCB 4 Pole of capacity 160 Amp , breaking capacity 25 KA with thermal release -2 Nos (d) MCCB 4 Pole of capacity 100 Amp , breaking capacity 25 KA with thermal release -1 No (e) Internal control wiring with 1100 volt grade of stranded copper cable as per colour coding for all connections with suitable size lugs as required and as specified. Note :- All MCCBs to be Ics= 100% Icu

-

-

-

... More
Dismantling cross arms of MS channels or angle sections etc complete all as specified and directed by Engineer-in-charge.

3

-

-

... More
M & L for cross arms bracing support clamps and back plates channel or angle section nuts bolts etc after painting with including two coat of aluminium paint over one coat of red oxide primer complete all as specified and directed by Engineer-in-charge.

2

-

-

... More
Re-fixing of cross arms/ clamps/nuts/ bolts/ washers etc on the refixed/new steel poles of any length complete all as specified and directed by Engineer-in-charge. Note :- Serviceable cross arms obtained from Ser Item No. 36.00 shall be used for refixing.

1

-

-

... More
S&F Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mm height, 65mm dia for 1100 volts grade including taking down existing pin type insulator of any description complete all as specified and directed by Engineer-in-charge.

15

-

-

... More
S&F shackle type insulator porcelain vitreous 75 mm high and 90 mm dia ball and socket type (white, brown or green) complete single disc assembly for tension with tension clamps suitable for ACSR conductor working pressure 1100 volts grade including taking down existing shackle type insulator of any description complete all as specified and directed by Engineer-in-charge.

6

-

-

... More
S&F stay assembly complete with accessories and GI stay rod 20 mm dia 1900 mm long, stay wire 7/4 mm stranded galvanised including mild steel stay plate 300 mm X 300 mm x 6 mm and galvanised thimble, galvanised steel 14 mm dia 400 mm long stay bow and GI nuts, washers including loop type insulator vitreous porcelain white, brown or green big size with overall dimensions 90 mm x140 mm clearance of hole 25.5 mm including taking down existing stay assembly of any description complete all as specified and shown in electrical plate No. 1 of SSR part–I.

5

-

-

... More
Supply, transportation fixing and errection of prestressed cement concrete pole in repair 9 metre long, minimum cross section 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class -10 confirming to IS-1678 and including making alternate whit e and black strips 30 cm height (Total 5 Nos), with two coats of synthetic enamel paint over a coat of primer and including taking down existing unserviceable pole of any description complete all as specified & directed by Engineer-in-charge. Note : Excavation and earth work and PCC for electric pole shall measured separately.

8

-

-

... More
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom, burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 25 x 3 mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing including taking down existing earthing complete all as specified and directed by Engineer-in-charge. NOTE:- (i) Excavation & earth work in any type of soil including removing of surplus material upto 100M (ii) PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. (iii) Main earthing strip from earth electrode to test point upto 7.5 mtr. (iv) Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. (iv) GI protection pipe of size 40 mm bore light grade 7.5m.

6

-

-

... More
Re - stretching only existing ACSR of any size on HT/ LT pole including binding the ACSR with insulators, aluminium binding wire complete all as specified & directed by Engineer-in-charge. Note : (i) The above work includes cleaning pruning of tree branches falling around the conductors. (ii) One length shall be measured for complete span of 4/5/6 conductors & GI wire.

25

-

-

... More
Cutting and trimming the tree branches touching the over head lines of LT/HT one meter around the conductor and removal the same from the site complete all as specified & directed by Engineer-in-Charge. Note:-Cutting of branches in span of 50 m will be considered as one job.

500

-

-

... More
Taking down or removing of rusted body part/panel door existing LT Panel feeder pillar box of any size and shap, supply, fixing and febrication in existing, shap and size with and including 2 mm thick CRCA sheet and all jointing material such as nuts, bolts or washer and welding etc complete all as specified & directed by Engineer-in-Charge. NOTE: (i) The panel board repaired shall be made totally enclosed, weather proof/wemin proof for installing incoming/outgoing MCCB/ Switch fuses/cable etc complete all as directed. (ii) The rates quoted by the contractor are deemed to be with and including necessary cutting, welding, levelling and jointing etc. as directed to match & accommodate with the existing feeder pillar box/panel board. (iii) The replaced porting shall be painted with two coat of synthetic enamled paint over a coat of red oxide primer. (iv) The rates quoted by the contractor deemed to be with and including dismantling/taking out/removing carefully, any damaed part/portion of the feeder pillar box/panel board as directed.

225

-

-

... More
M & L for painting the old existing LT panel board /feeder pillars of size 1400x1200x450mm including scraping and removing the old painted surfaces and painting /matching the same colour paint including two coats of super enameled paint (Gray paint) and without distrubing the existing electric system and removing grass and bushes including its roots growing around the panel all as specified and directed by Engineer-in-Charge.

10

-

-

... More
M & L for painting the old existing LT panel board /feeder pillars of size 1200x1050x450mm including scraping and removing the old painted surfaces and painting /matching the same colour paint including two coats of super enameled paint (Gray paint) and without distrubing the existing electric system and removing grass and bushes including its roots growing around the panel all as specified and directed by Engineer-in-Charge.

20

-

-

... More
M&L for straight through joints (epoxy) for under ground cable including joints kit complete for making joints suitable for aluminium conductor cables of size 16 sqmm to 25 sqmm 4 core including taking up of old existing joints complete all as specified and directed by Engineer-in-charge.

10

-

-

... More
M&L for straight through joints (epoxy) for under ground cable including joints kit complete for making joints suitable for aluminium conductor cables of size 35 sqmm to 50 sqmm 3½ core including taking up of old existing joints complete all as specified and directed by Engineer-in-charge.

7

-

-

... More
M&L for straight through joints (epoxy) for under ground cable including joints kit complete for making joints suitable for aluminium conductor cables of size 95 sqmm 3½ core including taking up of old existing joints complete all as specified and directed by Engineer-in-charge.

7

-

-

... More
M&L for straight through joints (epoxy) for under ground cable including joints kit complete for making joints suitable for aluminium conductor cables of size 3½ core 120 sqmm to 185 sqmm 3½ Core and including taking up of old existing joints complete all as specified and directed by Engineer-in-charge.

4

-

-

... More
M&L for plain cement concrete (1:3:6) type C-2 (using 40mm grade stone aggregate) for foundation of stay assembly struts or pole or around the pole structure etc complete all as specified and directed by Engineer-in-charge. Note : PCC (1:3:6) work in around the pole structure min 100mm thickness after cleaning the surface area.

20.5

-

-

... More
M&L for plain cement concrete (1:2:4) type B-1 (using 20mm grade stone aggregate) for coping/encasing around of pole including necessary form work finished and smooth without using extra cement complete all as specified & directed by Engineer-in-Charge.

4

-

-

... More
M & L for cement concrete (1:4:8) type D-2 using 40mm grade stone aggregate in foundation of PCC pole/struts as specified including necessary form work finishing even and smoth with out using extra cement complete all as specified & directed by Engineer-in-Charge.

0.4

-

-

... More
M&L for finding cable fault with electronic fault detector in LT UG cable of size 25 to 300 Sqmm complete including earthwork and jointing cable complete all as specified & directed by Engineer-in-Charge. Note :- LT UG & Joint Kit shall be measured paid separately.

11

-

-

... More
S&F LT cable route indicator made out of cast iron plate of 150 mm dia 4mm thick having embosed wiriting LT cable fixed on MS angle iron 30x30x5 mm of 900 mm long with two nuts,bolts and grouting 500 mm length under ground and splitted and bent to shape and embedded in ground with PCC (15 cmx 15cm x 15 cm) including taking down existing cable route indicator complete all as specified & directed by Engineer-in-Charge.

330

-

-

... More
M&L to defect faulty cable portion by excavating, cutting and taking out of burnt out unserviceabloe cable and replace new LT UG Cable size as required jointing both side with epoxy type straight through jointing kit and returning, filling complete all as specified & directed by Engineer-in-Charge. Note :- LT UG Cable and cable joints kit etc shall be measured and paid separately

10

-

-

... More
Material and labour for spreading levelling with 20 mm graded coarse aggregate / gravells laid approximately 75 mm thick layers near Feeder pillar/2/4 pole structure and plateform complete all as specified & directed by Engineer-in-Charge.

20

-

-

... More
S&F in repairs analog type Ammeter 0-800 Amps, 3phase ,with selector switch for existing panel complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F analog type volt meter 0-500 Volts, 3phase with selector switch for existing panel complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F in repairs digital Ammeter 0-800 Amps, 3phase for existing panel complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F digital volt meter 0-500 Volts, 3phase for existing panel complete all as specified and directed by Engineer-in-Charge.

5

-

-

... More
S&F LED indicating lamp of main supply indicating 'R', 'Y', 'B' (set of three) complete all as specified & directed by Engineer-in-Charge.

10

-

-

... More
S&F in repair Digital type Multifunctinal meter CT operated class 1 accuracy suitable for measuring v, A,PF,kW,kva etc 3 Phase, 4 digit, high resolution, LED type with one side programmability – 01 No. complete all as specified & directed by Engineer-in-Charge. Make- L&T Part No- WL411021OO00 or equivlent make and model as approved by GE.

8

-

-

... More
Removing grass and bushes including its roots growing at Substation yard/around the platefarm of transformer/ two poe/4 pole structure and LT Panel Boards/ Feeder Pillars box and keep the sub station yard/ plate farm area neat and clean complete all as specified & directed by Engineer-in-Charge.

2020

-

-

... More
S&F in repair cable joint kit indoor type heat shrinkable 1100V for XLPE cable of size 16 sqmm to 25 Sqmm 4 Core including suitabe size of lugs complete all as specified & directed by Engineer-in-Charge.

18

-

-

... More
S&F in repair cable joint kit indoor type heat shrinkable 1100V for XLPE cable of size 35 sqmm to 50 Sqmm 4 Core including suitabe size of lugs complete all as specified & directed by Engineer-in-Charge.

16

-

-

... More
S & F in repair cable joint kit indoor type heat shrinkable 1100V for XLPE cable of size 70 sqmm to 95 Sqmm 4 Core including suitabe size of lugs complete all as specified & directed by Engineer-in-Charge.

10

-

-

... More
S & F in repair cable joint kit indoor type heat shrinkable 1100V for XLPE cable of size 120 sqmm to 185 Sqmm 4 Core including suitabe size of lugs complete all as specified & directed by Engineer-in-Charge.

8

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.