Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_690189_1Tender No
8800/24-25/64/04/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel, PCC, excavation any other B/R work if required are deemed to be included in quoted rates.
INCOMING
(a) MCCB 4 pole, 415 Volts, 250 Amps, 25 KA - 02 No.
OUTGOING
(b) MCCB 4 pole, 415 Volts, 160 Amps,25 KA -04 No. (c) Onload changeover switch 4P, 415V , 250 Amp -02 (d) Digital multifunction meter with in built selector switch including CTs - 01 No.
(e) Indicator lamp (RYB) (set of three) - 01 Set
2
-
-
... More
Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel, PCC, excavation any other B/R work if required are deemed to be included in quoted rates.
INCOMING
(a) MCCB 4 pole, 415 Volts, 400 Amps, 25 KA - 02 No.
OUTGOING
(b) MCCB 4 pole, 415 Volts, 400 Amps, 25 KA - 02 No. (c) Onload changeover Switch 4P, 415V 400 Amp-02 Nos (d) Digital multifunction meter with in built selector switch including CTs - 01 No.
(e) Indicator lamp (RYB) (set of three) - 01 Set
1
-
-
... More
Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel, PCC, excavation any other B/R work if required are deemed to be included in quoted rates.
INCOMING
(a) MCCB 4 pole, 415 Volts, 320 Amps, 25 KA - 02 No.
OUTGOING
(b) MCCB 4 pole, 415 Volts, 200 Amps,25 KA -03 No. (c) Onload changeover Switch 4P 320 A -02 Nos (d) Digital multifunction meter with in built selector switch including CTs - 01 No.
(e) Indicator lamp (RYB) (set of three) - 01 Set
1
-
-
... More
Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel, PCC, excavation any other B/R work if required are deemed to be included in quoted rates.
INCOMING
(a) MCCB 4 pole, 415 Volts, 200 Amps, 25 KA - 02 No.
OUTGOING
(a) MCCB 4 pole, 415 Volts, 125 Amps,25 KA -04 No. (b) Onload changeover Switch 4P,415V 200 A - 02 Nos (d) Digital multifunction meter with in built selector switch including CTs - 01 No.
(e) Indicator lamp (RYB) (set of three) - 01 Set
1
-
-
... More
Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity aluminium bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated aluminium conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel, PCC, excavation any other B/R work if required are deemed to be included in quoted rates.
INCOMING
(a) MCCB 4 pole, 415 Volts, 200 Amps, 25 KA - 02 No.
OUTGOING
(a) MCCB 4 pole, 415 Volts, 160 Amps,25 KA -02 No. (b) Onload changeover Switch 4P,415V 160 Amp - 02 (d) Digital multifunction meter with in built selector switch including CTs - 01 No.
(e) Indicator lamp (RYB) (set of three) - 01 Set
1
-
-
... More
Supply(in repairs) ,install, commission and testing cubical type LT panel board of size as per requirement outdoor canopy type, manufactured by a CPRI approved factory, floor mounted, dust & vermin proof,front and rear operated door with necessary locking arrangement made of 50 x 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade after seven tank treatment process both internally and externally. The panel shall be suitable for 415 Volts, 50 HZ, 3 Phase 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and directed with the following accessories :- Note: Dismantling/disconnecting of existing panel, PCC, excavation any other B/R work if required are deemed to be included in quoted rates.
--------------------------------------------------------------------------------------------------------------------------------------
INCOMING
(a) MCCB 4 pole, 415 Volts, 160 Amps,25 KA - 02 No.
OUTGOING
(a) MCCB 4 pole, 415 Volts, 63 Amps,25 KA - 06 No. (b) Changeover switch 4P, 415v, 160 A -02 Nos (d) Digital Voltmeter 0-500 Vwith selector switch - 01 No.
(e) Digital Ammeter 0-600 Amps with CTs and selector switch - 01 No
(f) Indicator lamp (RYB) (set of three) - 01 Set
1
-
-
... More
M&L for laying, jointig, testing cable XLPE insulated, armoured and PVC sheathed LT 1000 volts grade and aluminium conductor confirming to IS 1554 laid in trenches/through pipes/floor/fixed wall etc complete all as specified and directed for size of cable 185 Sqmm 3.5 Core Stranded conductor.
30
-
-
... More
M&L for laying, jointig, testing cable XLPE insulated, armoured and PVC sheathed LT 1000 volts grade and aluminium conductor confirming to IS 1554 laid in trenches/through pipes/floor/fixed wall etc complete all as specified and directed for size of cable 240 Sqmm 3.5 Core Stranded conductor.
30
-
-
... More
M&L for laying, jointig, testing cable XLPE insulated, armoured and PVC sheathed LT 1000 volts grade and aluminium conductor confirming to IS 1554 laid in trenches/through pipes/floor/fixed wall etc complete all as specified and directed for size of cable 400 Sqmm 3.5 Core Stranded conductor.
30
-
-