Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_670433_1Tender No
8460/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
Removing surplus soil to a distance not exc 50.00 metre away and depositing where directed at a level not exc 1.50 metre above the starting point, complete all as specified and as directed by Engr-in-Charge.
202.56
-
-
M & L sand cushioning (dry) in trenches/ducts for protection of ug cables (below, above and around the ug cable laid in trenches) of 23 cm spread thickness (8 cm in depth before laying the cable and 15 cm in depth after laying the cable) and consolidated (punned) upto 180 mm thickness, complete all as specified and as directed by Engr-in-Charge.
171.32
-
-
Supply and laying un-reinforced precast conrete cable cover,class HVP,Type 1 with peak, size 300mm X 180 mm X 40 mm covering with width equal to length of cable cover as the mechanical protection to cable laid in trenches flat complete all as specified and directed by Engineer-in-charge.
1500
-
-
S & F sub-class ‘B’ brick, well burnt, laid breadthwise along the length of cable laid in trenches over sand cushion laid for UG cable protection, complete all as specified and as directed by Engr-in-Charge.
14.76
-
-
M & L boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr below the road surface with the help of GI tubing of any dia not exceed 80 mm bore for passing of UG cable complete all as specified and as directed by Engr-in-Charge.
Note : GI pipe laid shall be measured seperately.
60
-
-
Taking down/out unserviceable UG HT/LT Cables of any Cross Sectional Area and Connections and joints including Pipes, Bricks, etc of any description laying in trenches or fixed with Walls/Poles, segreating serviceable Pipes, Cables etc and keep in safe custody for reuse, complete all as specified and as directed by Engr-in-Charge.
Note : Earthwork will be measured and paid under appropriate Items.
2350
-
-
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area, laid in trenches/ surface of Wall/in GI pipe along with pole for connection to OH Lines including brass cable glands mild steel flat iron clamps, etc. and testing complete all as specified and as directed by Engr-in-Charge of following sizes below:-
-
-
-
All as per above item No 10.00 but size 4 core x 10 Sqmm
500
-
-
All as per above item No 10.00 but size 4 core x 25 Sqmm
500
-
-
All as per above item No 10.00 but size 3.5 core x 70 Sqmm
400
-
-
All as per above item No 10.00 but size 3.5 core x 150 Sqmm
350
-
-
All as per above item No 10.00 but size 3.5 core x 300 Sqmm
300
-
-
M&L for XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 120 sq. mm x 3 core including testing complete all as specified and as directed by Engr-in-Charge.
300
-
-
M&L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable including testing complete all as specified and as directed by Engr-in-Charge of following sizesn below :-
-
-
-
All as per above item No 12.00 but size 50 sqmm to 95 sqmm
2
-
-
All as per above item No 12.00 but size 120 sqmm to 185 sqmm
2
-
-
M&L straight through joint (heat shrink) including jointing kit complete for making joints suitable for UG aluminium conductor cable 3 ½ core of size 150 Sqmm to 185 Sqmm complete all as specified and as directed by Engr-in-Charge.
6
-
-
M&L straight through joint (heat shrink) including jointing kit complete for making joints suitable for UG aluminium conductor cable 3 ½ core of size 240 Sqmm to 300 Sqmm complete all as specified and as directed by Engr-in-Charge.
4
-
-
S & F Galvanised Iron Pipe light grade as in protection of UG Cable laid in trenches of following sizes complete all as specified and as directed by Engr-in-Charge including taking out old unserviceable pipe. Note : Cost of Mild Steel Clamp, Nuts, Bolts and painting is deemed to be included in the Quoted Unit Rate.
-
-
-
All as per above item No 15.00 but size 50 mm dia
24
-
-
All as per above item No 15.00 but size 40 mm dia
30
-
-
All as per above item No 15.00 but size 80 mm dia
18
-
-
Dismantling stay assembly complete with stay wire complete all as specified and as directed by Engr-in-Charge.
12
-
-
M & L Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 20mm, size of Plate 230 x 230 x 6 mm complete all as specified and as directed by Engr-in-Charge. Note : Earthwork, Cement Concrete, Mild Steel Stay Clamps with Bolts, Nuts, Stay Strand, Loop Insulator etc. will be measured and paid under approprite Items.
12
-
-
Dismantling of Cross arms of MS channel or angle section etc. complete all as specified and as directed by Engr-in-Charge.
2
-
-
M&L Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated/ directed and inclusive of one coat of Aluminium Primer one Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed by Engr-in-Charge.
2
-
-
Dismantling of old unserviceable insulators any type & any size from pole (PCC/RCC/Steel ) complete all as specified and as directed by Engr-in-Charge.
132
-
-
S&F Insulator Pin type Porcelain, Vitreous, White, Brown or Green including one Galvanised Mild Steel Spindle, Two Galvanised Iron Washers and One Galvanised Iron Nut, 100mm Height, 65mm dia for 1100 Volt grade complete all as specified and as directed by Engr-in-Charge.
80
-
-
S & F Shackle type, Porcelain, Vitreous, White or Brown Insulator of size 100mm height 115mm dia including Galvanised Mild Steel 31x5mm Strap, 14mm dia Insulator Bolts, Nuts, Washers, etc. for Working Pressure 1100 Volt, complete all as specified and as directed by Engr-in-Charge.
40
-
-
S & F Loop Type Insulator Vitreous White, Brown or Green, large size with overall dimensions 90x65mm, clearance of hole 16mm dia, complete all as specified and as directed by Engr-in-Charge.
12
-
-
Dismantling and taking down of old unserviceable ACSR conductors, GI Wire from existing PCC/RCC/Steel poles, complete all as specified and as directed by Engr-in-Charge.
7
-
-
S & F Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) with permissible Sags and providing Jumper, etc., fixing on Electric Poles and binding to Insulators with Aluminium Binding Wire as in OH Conductors including stringing, tightening, etc., complete all as specified and as directed by Engr-in-Charge.
Note : Cost of Binding Wire is deemed to be included in the quoted Unit Rate.
5
-
-
Fixing only and labour for Releasing GI Wire of existing OH Lines by un-binding from Insulator of any description, re-fixing after stretching, re-stringing GI Wire, removing excess Sag, maintaining proper distance between Conductors as ordered, and binding to insulators with Aluminium Binding Wire complete all as specified and as directed by Engr-in-Charge.
Note : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
2
-
-
Fixing only and labour for Releasing ACSR Conductor of existing OH Lines by un-binding from Insulator of any description, re-fixing after stretching, re-stringing the Conductor, removing excess Sag, maintaining proper distance between Conductors as ordered, and binding to insulators with Aluminium Binding Wire complete all as specified and as directed by Engr-in-Charge.
Note : Cost of Binding Wire is deemed to be included in the Quoted Unit Rate.
10
-
-
Taking down old unserviceable Line Separator in repair and S & F in replacement new PVC/ Fibre Separator for LT Lines 1100 Volts OH Conductor 2 Wire system for horizontal spacing of Conductor, fixing with Nuts, Bolts, Washers, etc , complete all as specified and as directed by Engr-in-Charge.
80
-
-
Taking down old unserviceable Line Separator in repair and S & F in replacement new S & F PVC/ Fibre Separator for LT Lines 1100 Volts OH Conductor 4 Wire system for horizontal spacing of Conductor, fixing with Nuts, Bolts, Washers, etc., complete all as specified and as directed by Engr-in-Charge.
30
-
-
Supply & install Air Break Switch, Gang Operated Triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps 11KV complete all as specified and as directed by Engr-in-Charge including taking down old unserviceable of any size and capacity.
15
-
-
M&L Non linear expulsion type surge arrester( lightening arrestors) confirming to IS 3070 (Part 1) having voltage rating 12 KV, Rated frequency-50 HZ, Nominal discharge capacity 65 kilo amp complete with all fittings , suitable for 11KV, 3-Phase, earthed distribution system complete all as specified including taking down old unserviceable of any size and capacity, complete all as specified and as directed by Engr-in-Charge.
8
-
-
M&L Drop Out Fuses 'D' Type/ 'Channel' Type confirming to IS 9385 having voltage rating 12 KV, Rated frequency-50 HZ, Continuous current rating 200 Amp and insulator post type(Porcelain/ Polymer) complete with all fittings , suitable for 11KV, 3-Phase system complete all as specified and as directed by Engr-in-Charge including taking down old unserviceable of any size and capacity.
12
-
-
M&L in repair for earthing complete with using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing leadthick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to copper strip 20 x 3mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and as directed by Engr-in-Charge.
16
-
-
M&L in repair for earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, burried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized strip 32 X 6mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to OH conductor on pole/ Panel/ main switch board etc all as specified or indicated and testing on completion including provision galvanized strip protected by 40 mm bore, light grade pipe and watering pipe shall be 20 mm bore medium grade GI pipe including excavation & earth work, PCC pit with RCC cover, charcoal, salt, funnel, GI strip and protection pipe upto 7.5 mtr complete all as specified and as directed by Engr-in-Charge.
28
-
-
M&L in repair for earth continuity conductor or main Earthing lead Galvanised iron strip of size 32 x 6 mm fix to pole, wall or buried in ground or down GI pipe or any type indicated situation for loop earthing/ lighting conductor etc as required with saddles and fixing screws for roof conductors and down conductors above ground level complete all as specified and as directed by Engr-in-Charge.
100
-
-
Dismantling concrete poles/ struts, any size and transporting to contractor's store and stacking complete all as specified and as directed by Engr-in-Charge.
10
-
-
M & L in repair for prestressed concrete pole, 11.0 metres long, 152 mm X 152 mm at top and 152 mm X 260 mm at bottom designed for wind load at the site complete all as specified and as directed by Engr-in-Charge.
10
-
-
M&L Cement Concrete 1:4:8 (40mm graded aggregate) as Lean Concrete in Foundation of Poles, Stay Assembly, etc., including Form-work (as/if required), complete all as specified and as directed by Engr-in-Charge.
0.35
-
-
M&L Cement Concrete 1:3:6 (40mm graded aggregate) as in Foundation of Poles, Stays, etc. including Formwork (as/if required) complete all as specified and as directed by Engr-in-Charge.
4.28
-
-
M&L Cement Concrete 1:2:4 (20mm graded aggregate) as in Coping of Poles, etc. and finishing the Concrete surfaces Fair and Even including necessary Formwork required at Site(s), complete all as specified and as directed by Engr-in-Charge.
0.7
-
-
Cutting unaxious green growth and wild grass by manual labour or by machine at Electrical Installation Premises, around Pole, along the boundary Fencing, removing rubbish from the Site of Work and deposting where directed not exc. 100 Metre from the starting Point, complete all as specified and as directed by Engr-in-Charge.
Note : The Item shall be operated maximum 2 times in the entire period of the Contract and the measurement will be taken every time independently for Payment.
1200
-
-
Cutting/ trimming of tree branches not exc 150mm girth touching/approaching the LT/HT overhead lines conductors by manual labour using hack saw/axe or by cutter machine to clear the LT/HT line upto 3 metre on each side including disposal of trimmed branches 100 Metre away inside the station area & clearing site complete all as specified & directed by Engr-in-Charge. Note:-Distance between two poles shall be considered as single span.
300
-
-
Total in Figures
-
-
-
Quoted Amount in Words
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements