Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_680734_1Tender No
GE/JODH (A) NO 1- OF 2024-25 (9293/E8)Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Disconnecting of electric and water supply connection of geyser for supply and replacement of brass chromium in-door assembly(shyphon assy) 6/9 hole for 25 Ltrs Geyser including connect with existing connections and testing, complete all as specified and directed.
90
-
-
S&F in replacement of 15 mm bore, GI tubing medium grade, galvanized, with all fittings fixed to wall, ceilings or laid in floors including cutting chases, pinning in and making good distrubed surface to match with existing surface and finish, etc., complete all as specified and as directed.
210
-
-
S&F in replacement of bib cock with flange 15mm dia, chromium plated, cast copper alloy, fancy type, screwed for iron pipe or for brass ferrule, complete all as specified and directed.
80
-
-
S&F in replacement of angular stop cock with wall flange, chromium plated, cast copper alloy, fancy type 15mm dia complete all as specified and as directed.
80
-
-
S&F in replacement of PVC connection heavy duty, nylon braided, suitable for hot water, with brass alloy chromium plated nuts and nylon washers, of size15mm bore and 450 mms long, complete all as specified and as directed.
150
-
-
All as per srl item No 8.00 here in-above but 600mm long.
350
-
-
S&F in replacement of single pole and neutral enclosure with two pin earth industrial plug and socket with one MCB SP 20 Amps, 'C' curve, complete all as specified and as directed.
75
-
-
Supply only for heating element (ISI-Marked) of suitable type as per existing including rubber ring clamping screws etc,complete of 1.5KW, complete all as specified and as directed.
120
-
-
All as per srl item No 11.00 here-in-above but 2.00 KW
500
-
-
Supply only for thermostate ISI-marked for geyser as per existing of range 15-65 degree temperature, complete all as specified and as directed.
450
-
-
Supply only for auto-cut ISI marked for geyser as per existing, complete all as specified and directed.
150
-
-
Supply only for steel vessel (tank)of geyser capacity 25 ltrs. as per existing type of all as specified directed by EIC.
70
-
-
All as per srl item No 15.00 here-in-above but capacity 50 ltrs.
45
-
-
Supply only for vacuum safety valve of suitable size on inlet side of geyser, complete all as specified and directed.
70
-
-
Supply only for brass chromium plated horizontal/vertical non return valve of size 15mm bore (ISI Marked) on inlet side of Geyser, complete all as specified and directed.
70
-
-
Supply only for pressure release valve of size 15mm bore complete all as specified.
50
-
-
Supply only for brass nut fusible plug suitable for Geysers, complete all as specified and directed.
30
-
-
M&L for drilling hole in wall, grouting fastner nut and bolt not less than 100 mm long for holding geyser upto 50 ltrs in wall including making good and matching existing surface and finish all as directed.
200
-
-
Supply only for indicating lamp of red and green colour, for Geysers including connecting, complete all as specified and directed.
130
-
-
Supply only for bottom split inspection cover for geyser capacity 25 ltrs. of any make,complete all as specified and directed.
95
-
-
All as per item No. 23.00 here-in-above but capacity 50 Ltrs
50
-
-
Supply only for outer body made of stainless steel sheet for geyser capacity 25 ltrs. of any make, complete all as specified and directed.
80
-
-
All as per item No. 25.00 here-in-above but capacity 50 Ltrs.
60
-
-
Supply only for Rubber Gasket as per site requirement for 25/50 ltrs. geyser, complete all as specified and directed.
200
-
-
M&L for scrapping old paint and applying spray painting two coats of synthetic enamelled paint of approved quality including writing MES No. / building no. in letters of size 40 mm width. For geyser cap. - 25 ltrs of any make/type . (NOTE : Rates shall deemed to be included for taking down Geyser in location and position , disconnecting and refixing same existing postion &reconnecting electrical / water connection all as directed)
150
-
-
All as per item No. 28.00 here-in-above but capacity 50 Ltrs
100
-
-
M&L for replacement of GLASS WOOL for Geysers of any capacity, complete all as specified and directed.
40
-
-
S&F in replacement of MCB SP 5 To 32 AMP Amp, 10KA, complete all as specified and directed.
50
-
-
S&F in replacement of three pin top 20 Amp, complete all as specified and directed.
70
-
-
S&F in replacement of metal clad plug socket 3 pin 20 Amp, complete all as specified and directed.
80
-
-
S&F in replacement of metal clad plug Top 3 pin 20 Amp, complete all as specified and directed.
100
-
-
M&L for concealed point wiring complete with 2.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FR-LSH cable (RYBN) 1100 volts grade drawn through and including non metallic rigid PVC heavy duty concealed conduit/Surface conduit with wall thickness not less than 1.8 mm including conduit accessories like bends, tees junction boxes, etc fixed concealed/recessed in wall or ceiling etc including 2.5 Sq mm, single core, PVC insulated but unsheathed multi stranded copper conductor FR-LSH cable (Green) 1100 Volts grade as earth continuity wire connected to earth dolly and including piano sunken galvanized terminal boxes of same make of switch/ socket/ regulator with sleek and curvy cover plates, for mounting of piano switch, complete all as specified and directed.
30
-
-
S&F in replacement of piano type Socket, 16 Amps, - 2/3 pin combined flush type, 230 Volts complete all as specified and as directed.
120
-
-
S&F in replacement of piano type Switch 1 way, 16 Amps, flush type, 230 Volts complete all as specified and as directed.
120
-
-
S&F in replacement of PVC insulated copper conductor 1100 volts grade circular cable of size 2.5 sqmm (50/.025) 3 core complete. Polycab, Havells
180
-
-
S&F for sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 4 Sqmm and one run of 4 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 20 mm dia with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed. NOTE: Two runs of 4 Sqmm cable with one run of 4 Sqmm earth wire and PVC conduit shall be measured & paid for as one length.
180
-
-
All as per item No. 39.00 here-in-above, but cable drawn through in PVC casing-N-capping
200
-
-
All as per item No. 39.00 here-in-above, but cable size 2.50 sqmm
185
-
-
All as per item No. 41.00 here-in-above, but cable drawn through in PVC casing-N-capping
215
-
-
S&F in replacement of socket outlet 2 in 1, 5 pin, 5 and 15 amp modular type ISI Marked, complete all as specified and directed.
100
-
-
S&F in replacement of switch modular type single pole one way 15/16 Amp ISI Marked, complete all as specified and directed.
100
-
-
M&L for welding/brazing steel/copper vessel ( storage water tank of capacity 25/50 ltrs ) including pressure testing and leakage testing, complete all as specified and directed.
45
-
-
M&L for cheking of Solar water heater system of any capacity and make installed at ARMY AREA Jodhpur, complete all as specified and directed.
20
-
-
De-scaling & servicing of Solar Water Heater system of any capacity and any makeincluding re-insulation and making fit for smoth function,complete all as specified.
20
-
-
M&L for solar heat absorbers (collectors) with selective coating sheet as per existing panel length & width complete all as specified.
5
-
-
M&L for heating element of capacity 3/5 KW ISI Mark as per existing panel length & width complete all as specified.
10
-
-
M&L for thermo stat ISI Marked, suitable for existing panel complete all as specified.
10
-
-
M&L for repair to damaged panel tubing with gas welding of Solar Water Heater of any capacity/any make, complete all as specified and as directed.
2
-
-
Dismantling and taking down unserviceable pressure pumps and motor of cap not more than 2 HP of any capacity and description and refixing to the position after servicing and minor repairs as refilling of pressure replacement of auto cut switch etc the job include rewinding of motor all as specified and directed.
8
-
-
S&F in replacement of sub-main wiring (concealed) with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade of size 6 Sqmm and one run of 6 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non-metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed. NOTE: Two runs of 6 Sqmm cable with one run of 6 Sqmm earth wire and PVC conduit shall be measured & paid for as one length.
120
-
-
S&F in replacement of stop Cock CP brass 15 mm bore screwed down with crutch or butterfly handle, complete all as specified and directed.
55
-
-
S&F in replacement of bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm- 90gms/20mm- 125gms) of Size 15mm complete all as specified and directed.
70
-
-
M&L for insulation of GI Pipe with PUF slab 30mm thick with and including applying bituminus compound and GI Cladding with GI Sheet complete of Size 20 mm dia complete all as specified and directed.
120
-
-
S&F in replacement of 20 mm bore GI tubing medium grade, galvanized, with all fittings fixed to wall, ceilings or laid in floors, complete all as specified and as directed. .
100
-
-
S&F in replacement of male Brass threaded adopter 20mm dia complete all as specified and directed.
15
-
-
M&L for replacement of assembly bottom cover (Inspection cover) split type made of MS sheet same guage of existing cover duly painted with two coats of synthetic enemel paint over one of red oxide primer, complete all as specified and directed.
70
-
-
M&L for replacement of bottom cover for outer body made out of MS sheet of same guage of existing cover and size duly painted with two coats of synthetic enamel paint of existing geyser colour over one coat of red-oxide primer, complete all as specified and directed.
80
-
-
M&L for earthing complete with galvanised steel earth plate electrode 60 x60cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate no. 5 connected to Earthing test point all as specified or indicated including testing on completion Note : (i) Rates are deemed to be included for necessry earth work ,PCC pit , RCC cover etc complete. (ii) Earth lead shall be up to 7.5 Mtr and rates are deemed to be included for GI pipe 15mm Light grade upto 7.5 mtrs for protection of earth wire 4.0 mm dia, complete all as specified and as directed.
5
-
-
M&L for repair, rewinding of submersible pump monoblock type of capacity upto 3 HP, single or three phase, any make incl connection, testing complete all as specified and directed
6
-
-
M&L for repair, rewinding of submersible pump monoblock type of capacity upto 7.5 HP, single or three phase, any make including connection, testing complete all as specified and directed
3
-
-
M&L for repair, Servicing /rewinding of submersible/pressure pump any type of capacity upto 3 HP, single or three phase, any make including connection, testing, in the location of cherai, chordiya, LSL & DKD, complete all as specified and directed.
3
-
-
S&F in repair spare parts of submersible pump monoblock type of capacity upto 7.5 HP (i.e Water pump lock, thread cap, motor fan, pump tube pipe, wire assembly cap, pump valve assembly, plastic pump handle and capacitor cover) including connection, testing complete all as specified and directed.
6
-
-
S&F in replacement direct-on-line starter submersible pump of capacity 5 HP, 3 Phase, 415 Volt, with and including connection, testing,complete all as specified and directed.
3
-
-
NOTE:- (i)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%