Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Machinery and Tools
Eprocure
Opening Date25 Jan 2025
Closing Date15 Feb 2025
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L sand cushioning with dry and clean locally available sand for under ground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified. (Note : Punned thickness shall be considered for payment purpose)

440.32

-

-

... More
Supplying and laying, factory made unreinforced precast concrete cable cover LV type-1, flat, of size 250x150x40mm, laid flat and dry in trenches over the cable for protection, length perpendicular to the direction of cable adjacent to each other, complete all as specified and directed.

30

-

-

... More
M & L for Taking down/ out underground cable of aluminium conductor of 10 to 35 Sqmm any core after disconnection from sheet metal enclosure/ panel board or from OH line and taking out from trenches including taking out brick cable cover complete, removing sand and relaying the same after clearing the fault of the cable, making good to the cable after removing the unserviceable part of the cable by making LT Joint at the appropriate location wherever required. Note : Exavation, earthwork, cable joint and part of cable reequired for joint will be measured and for taking out old U/S cable and for laying of new cable will be measured and paid seperately under respective item of BOQ.

1380

-

-

... More
M & L for Taking down/ out underground cable of aluminium conductor of 50 to 70 Sqmm any core after disconnection from sheet metal enclosure/ panel board or from OH line and taking out from trenches including taking out brick cable cover complete, removing sand and relaying the same after clearing the fault of the cable, making good to the cable after removing the unserviceable part of the cable by making LT Joint at the appropriate location wherever required. Note : Exavation, earthwork, cable joint and part of cable reequired for joint will be measured and for taking out old U/S cable and for laying of new cable will be measured and paid seperately under respective item of BOQ.

900

-

-

... More
M & L for Taking down/ out underground cable of aluminium conductor of 95 to 185 Sqmm any core after disconnection from sheet metal enclosure/ panel board or from OH line and taking out from trenches including taking out brick cable cover complete, removing sand and relaying the same after clearing the fault of the cable, making good to the cable after removing the unserviceable part of the cable by making LT Joint at the appropriate location wherever required. Note : Exavation, earthwork, cable joint and part of cable required for joint will be measured and for taking out old U/S cable and for laying of new cable will be measured and paid seperately under respective item of BOQ.

1350

-

-

... More
Laying only old bricks (old Size) retrieved from item No 6 to 8 laid in trenches as cable protection all as per specified and directed by Engr-in-Charge

9.17

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 185 Sqmm 3.5 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

200

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 35 Sqmm 3.5 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

450

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 50 Sqmm 3.5 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

450

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 16 Sqmm 4 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

450

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 10 Sqmm 2 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

480

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 95 Sqmm 3.5 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

300

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 70 Sqmm 3.5 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

450

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 120 Sqmm 3.5 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

400

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 150 Sqmm 3.5 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

450

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 16 Sqmm 4 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

800

-

-

... More
Supply and laying and testing cable LT XLPE insulated, screened, PVC bedded, glavanized steel strip or wire armoured, electric power cable (heavy duty) 1100 volt grade with stranded aluminium condutor size 25 Sqmm 4 Core including making necessary electrical connections by using AI thimbles of appiropriated size including taking out old cable complete all as specified and directed Note : Excavation, earthwork will be measured and paid separately under respective item respective item of BOQ.

400

-

-

... More
Supply and fixing in repair of 1100 V Grade heavy duty twin core flexible PVC insulated copper conductor cable of size 2.5 Sqmm for connection purpose including PVC Conduit 20 mm dia of 2 mm thickness complete all as specified and directed by Engr-In-Charge. Make : Plaza, Finolex, Kalinga

200

-

-

... More
Supply and fixing in repair of 1100 V Grade heavy duty twin core flexible PVC insulated copper conductor cable of size 1.5 Sqmm for connection purpose including PVC Conduit 20 mm dia of 2 mm thickness complete all as specified and directed by Engr-In-Charge. Make : Plaza, Finolex, Kalinga

200

-

-

... More
M & L for preparation of old painted surface of steel tubular pole (9/11 meter long above coping) and applying two coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint, rewritting pole No by paiter with enamel paint, and painter the existing MS clamp with one coat of aluminium paint complete all as specified and directed.

50

-

-

... More
M & L for preparation of old painted surface of LT RCC pole(up to 6.10 meter height above coping) and applying two coat of cement base paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint, rewritting pole No by paiter with enamel paint, and painter the existing MS clamp with one coat of aluminium paint complete all as specified and directed.

100

-

-

... More
Supply and fixing in repair LT cable junction box, dust and water proof (IP65), out door type, made out of Polycarbonate with glass fiber re-inforced, size of box 200 x 160 x 98 mm with swiveling cover and locking clamp, pole mounting, consisting of aluminium bus bar strip 150mm x 20mm x 3mm, 4 Nos mounted on PVC insulator and provision of incoming/outgoing cables with gland, including in built 6Amp MCB, SP, 9/10KA one No complete all as specified and as directed by Engineer-in-charge. Make :- Hensel Cat part No. K9350 or equivalent in Sintex/Sagar Frp Industries Gurgaon.

100

-

-

... More
Supply and fixing in repair energy efficient LED security light fitting of 35W pressure die cast aluminium housing/body, heat resistant clear toughened glass, better optics for uniform distribution street luminaire, with driver, including electric connection with using 2 core flexible copper conductor cable 1Sqmm from ceiling rose to light fitting, fixing the light fitting with new bracket made out of GI tubing light grade 32mm dia, 1.5 metre long bent to shape at 120 degree angle at half metre from bottom, including two Nos clamps made out of MS Flat iron size 25x3 mm with suitable nuts and bolts for fixing of bracket including painting to MS clamp and nut bolts with two coats of aluminium paint over a coat of red oxide primer, complete fitting with all accessories and following specifications, complete all as specified and directed by Engineer-in-Charge :- (a) Lumen system efficacy of luminaire should be minimum 110 Lumen per watt. (b) Input Voltage range : 140 to 270 volts (c) Temp operating range : Minus 10°C to Plus 50°C (d) Power factor : Minimum 0.95 (e) THD : Max10%. (f) IP rating : IP66. (g) IK rating : Minimum IK07 (h) Built in potted LED Driver of the make as of the luminaire. (j) LED driver should be complete with all protections viz open/short circuit protection, over voltage protection, all as per standard design of manufacturer. (k) Surge protection 10 kV (inbuilt + extended) (l) CCT : 5700 K. (m) CRI : Minimum 70 (n) Lens - High Efficiency wide angle lens. (o) BIS Approved fixtures and driver (p) Rated life time : 50000 burning hrs @L70 (Average 10 to 12 hrs daily)

100

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB triple pole with neutral of 160 Amp breaking capacity 36 KA, suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and wahser etc complete all as specified and directed by Engr-In-Charge

2

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB triple pole with neutral of 200 Amp breaking capacity 36 KA, suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and wahser etc complete all as specified and directed by Engr-In-Charge

2

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB triple pole with neutral of 250 Amp breaking capacity 36 KA, suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and wahser etc complete all as specified and directed by Engr-In-Charge

2

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB triple pole with neutral of 320 Amp breaking capacity 36 KA, suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and wahser etc complete all as specified and directed by Engr-In-Charge

2

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB triple pole with neutral of 400 Amp breaking capacity 36 KA, suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and wahser etc complete all as specified and directed by Engr-In-Charge

2

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB triple pole with neutral of 100 Amp breaking capacity 25 KA, suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and wahser etc complete all as specified and directed by Engr-In-Charge

4

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB triple pole with neutral of 200 Amp breaking capacity 25 KA, suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and wahser etc complete all as specified and directed by Engr-In-Charge

4

-

-

... More
Disconnecting the existing unserviceable MCCB from the cable, taking out from the panel board and supply and fix new MCCB triple pole with neutral of 250 Amp breaking capacity 25 KA, suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and wahser etc complete all as specified and directed by Engr-In-Charge

4

-

-

... More
Disconnecting the existing unserviceable changeover switch from the cable, taking out from the panel board and supply and fix new on load changeover switch complete with sheet metal enclosure of 630 Amp capacity , suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and washer etc complete all as specified and directed by Engr-In-Charge

1

-

-

... More
Disconnecting the existing unserviceable changeover switch from the cable, taking out from the panel board and supply and fix new on load changeover switch complete with sheet metal enclosure of 400 Amp capacity , suitable for 415 Volt, 50 Hz, 3 Phase suuply, fixed in existing panel and connecting with existing cable, including nuts, bolt and washer etc complete all as specified and directed by Engr-In-Charge

2

-

-

... More
Disconnecting the existing unserviceable changeover switch from the cable, taking out from the panel board and supply and fix new on load changeover switch complete with sheet metal enclosure of 250 Amp capacity , suitable for 415 Volt, 50 Hz, 3 Phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolt and washer etc complete all as specified and directed by Engr-In-Charge

2

-

-

... More
Disconnecting the existing unserviceable changeover switch from the cable, taking out from the panel board and supply and fix new on load changeover switch complete with sheet metal enclosure of 200 Amp capacity , suitable for 415 Volt, 50 Hz, 3 Phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolt and washer etc complete all as specified and directed by Engr-In-Charge

2

-

-

... More
Disconnecting the existing unserviceable changeover switch from the cable, taking out from the panel board and supply and fix new on load changeover switch complete with sheet metal enclosure of 100 Amp capacity , suitable for 415 Volt, 50 Hz, 3 Phase supply, fixed in existing panel and connecting with existing cable, including nuts, bolt and washer etc complete all as specified and directed by Engr-In-Charge

4

-

-

... More
Material and labour for preparation of old painted surface of electrical panel inner and outer surface complete of size length (0.5 m to 1 m), Height (1m to 2 m) and breadth (upto 0.5m) by scrubbing with iron brush and applying two coats of synthetic enamal paint with spray machine complete all as specified and directed.

8

-

-

... More
Material and labour for preparation of old painted surface of electrical panel inner and outer surface complete of size length (1 m to 2 m), Height (1m to 2 m) and breadth (upto 0.5m) by scrubbing with iron brush and applying two coats of synthetic enamal paint with spray machine complete all as specified and directed.

10

-

-

... More
Supply install testing and commissiong in repairs LT control panel compartmental type Lockable fabrication with dimension 1200 (H) x 500 (W) x 500 (D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mm x 40 mm x 6 mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glande, foundation/grouting on & including PCC as per site requirement with the following : (a) AI bus bar 500 Amp Cap-1 Set (Set of 4 Strips) (b) MCCB 400 Amp 415V 4P 50 KA-1 No (incoming). (c) MCCB 250 Amp, 4 Pole, 35 KA with spreader links-2 Nos (outgoing) (d) MCCB 125 Amp, 4 Pole, 25 KA with spreader links-2 Nos (outgoing) (e) Indicating fuse LED type R,Y,B-3 Nos (f) Digital street ligh timer with contractor 100 Amp-01 Nos

4

-

-

... More
Supply install testing and commissiong in repairs LT control panel compartmental type Lockable fabrication with dimension 1200 (H) x 500 (W) x 500 (D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mm x 40 mm x 6 mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glande, foundation/grouting on & including PCC as per site requirement with the following : (a) AI bus bar 300 Amp Cap-1 Set (Set of 4 Strips) (b) MCCB 250 Amp 415V 4P 35 Ka-1 No (incoming). (c) MCCB 200 Amp, 4 Pole, 25 KA with spreader links-2 Nos (outgoing) (d) MCCB 125 Amp, 4 Pole, 10 KA with spreader links-2 Nos (outgoing) (e) MCCB 63 Amp, 4 Pole, 25 KA with spreader links - 4 Nos (outgoing) (f) Indicating fuse LED type R,Y,B-3 Nos (g) Digital street ligh timer with contactor100 Amp-01 Nos

4

-

-

... More
Supply install testing and commissiong in repairs LT control panel compartmental type Lockable fabrication with dimension 1200 (H) x 500 (W) x 500 (D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mm x 40 mm x 6 mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glande, foundation/grouting on & including PCC as per site requirement with the following : (a) AI bus bar 150 Amp Cap-1 Set (Set of 4 Strips) (b) MCCB 125 Amp, 4 Pole, 25 KA -1 Nos (Incoming) (c ) MCCB 63 Amp, 4 Pole, 10 KA with spreader links -2 Nos (outgoing) (f) Indicating fusse LED type R,Y,B-3 Nos (e) control fuse -03 Nos

3

-

-

... More
Supply install testing and commissiong in repairs LT control panel compartmental type Lockable fabrication with dimension 1200 (H) x 500 (W) x 500 (D) made by 3.15 mm thick sheet CRCA approved weather proof design framed on angle iron (40mm x 40 mm x 6 mm) double door front and rear openable both side opening shutters duly painted two coat with siemens gray color, cable entry with glande, foundation/grouting on & including PCC as per site requirement with the following : (a) AI bus bar 300 Amp Cap-1 Set (Set of 4 Strips) (b) MCCB 4P 415 V 250 Amps- 01 Nos (c) Indicating fuse LED type R,Y,B-3 Nos

3

-

-

... More
S & F in repair digital voltmeter 0-500 volts of Size 96 x 96 mm complete all as specified and directed by Engr-in-Charge Make : C & S/BHEL/ABB/SIEMENS

20

-

-

... More
S & F in repair digital Ampere meter 0-500 volts of Size 96 x 96 mm complete all as specified and directed by Engr-in-Charge Make : C & S/BHEL/ABB/SIEMENS

20

-

-

... More
Supply and errecting in repair prestressed cement concrete poles 9 meters long of cross section (102 mm x 152 mm) at top and (102 mm x 289 mm) at bottom class-10 complying with requirement of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer balck and white strips 30 cm wide each (05 Nos) yp to 1.5 mtrs height from coping & numbering of poles complete all as specified and directed. Note : Excavation, earthwork and PCC shall be measured and paid separately under respective item of BOQ

10

-

-

... More
M&L PCC (1:2:4) type B1 using 20mm graded stone aggregates as in coping of poles etc including weathering slightly roundded or chamfered angle and throating necessary form work finishing all exposed faces of concrete etc complete all as specified and directed. ( Volume of poles/struts embedded in concrete shall be deducted. )

0.54

-

-

... More
M&L PCC 1:4:8 type D2 using 40mm graded aggregate as in foundation of electric poles/struts etc including necessary form work and fair finish to exposed surface without using extra cement complete all as specified and directed. Note : Volume of poles/struts embedded in concrete shall be deducted.

5.4

-

-

... More
M & L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate) in coping for electric poles or for stay assy etc. complete all as specified and as directed by Engr-in-Charge.

1.08

-

-

... More
Dismantling of existing LT pole any size/type from foundation in necessary earth work including dismentling of concrete MS clamps nuts, bolts, earth wire, overhead lines conductor, insulators, gaurding cradles and other accessories complete all as specified and directed.

14

-

-

... More
M&L in replacement for 40mm bore GI pipe light grade with all fittings and fixtures fixed to pole and laid to floor/ground for mechanical protection of cable strip all as specified and directed

60

-

-

... More
M&L heat shrinkable straight through XLPE/PVC cable joint LT of size 25 sqmm to 50sqmm 3.5 core after dismantling unserviceable one complete all as specified and directed.

2

-

-

... More
M&L heat shrinkable straight through XLPE/PVC cable joint LT of size 95 sqmm to 120 sqmm 3.5 core after dismantling unserviceable one complete all as specified and directed.

2

-

-

... More
M&L heat shrinkable straight through XLPE/PVC cable joint LT of size 150 sqmm to 185/225 sqmm 3.5 core after dismantling unserviceable one complete all as specified and directed.

2

-

-

... More
Dismantling /taking out old ACSR and GI earth wire any size from existing over head lines incl disconnection all as specified and directed

2.8

-

-

... More
Dismantling /taking out insulator of any size/ type from existing electric LT Line all as specified and directed

100

-

-

... More
S & F for cable route indicator post 900 mm long made of precast cement concrete (1:2:4) type B-1, using 20 mm graded stone aggregate reinforced with 8 mm dia MS bars of semicircular shape 15 cm dia 10 mm thick duly engraved MES LT cable having RCC pillar of size 10 cm x 10 cm x 60 cm embedded 45 cm below ground level and 15 cm above ground level and painted with two coats of synthetic enamel paint above ground level including necessary excavation and earth work complete all as specified and as directed

40

-

-

... More
M&L for repairing LT panel board by necessary welding to door hinges, and fixing the sliding bolt for proper locking arrangement and making good all electical connection of LT panel Size 1000 x 1200 x 400 mm including replacement of rubber gasket and spray painting complete panel with synthetic enamel paint over a coat of red oxide including preparation of old surface complete all as specified and as directed.

30

-

-

... More
Note:- Contractor will submit all the old unserviceable item retrived from above mentioned schedule of item to MES store yard. Transportation charges for the same is responsibility of contractor and no extra payment shall be made on this account

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.