Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 18,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_679713_1Bid Award Id
ViewTender No
8408/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://defproc.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
... More
Supply And Laying in repair 10 Sqmm 4 core XLPE insulated, steel armoured, 1100 Volts grade in trenches / ducts / through pipes / on poles / roads fixing to the poles through clamps and connecting up, testing and commissioning including taking down old unserviceable LT UG cables, jointing and testing complete all as specified and as directed. Note: Excavation and earth work, cable covers, sand cushioning will be measured and paid separately under relevent items of this schedule.
30
-
-
... More
Description all as per BOQ item no. 04 here-in-before but of size16 Sqmm 4 core
30
-
-
... More
Description all as per BOQ item no. 04 here-in-before but of size 25 Sqmm 4 core
30
-
-
... More
Description all as per BOQ item no. 04 here-in-before but of size 35 Sqmm 4 core
30
-
-
... More
M&L for painting of steel tubular 7.5 mtr long poles after preparing old paint surfaces with two coat of Aluminium paint and two coats of zebra marking with enamel paint of approved make from ground level & upto 1 mtr high including white washing the coping and painting the pole terminal box complete all as specified and directed.
80
-
-
... More
Supply and installation in Repair of multi crystaline modules 24 Volt, 250W Ps per MNRE specs including installation and internal wiring UV protected wires 4 Sqmm PVC insulated copper conductor from module to inverter Room complete all as specified and directed.
4
-
-
... More
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in hard/dense soil for laying of cable and foundation of pole etc complete all as specified and directed.
30
-
-
... More
M & L for providing dry river washed sand in trenches as sand cushioning to U/G cable including punning down of sand in layer complete all as specified and directed.
(Note :- Punned thickness shall only be measured and paid).
20
-
-
... More
Returning, filling in, including spreading, leveling, watering & well ramming in layers not exc. 25 cm for soil complete all as specified and directed.
10
-
-
... More
Removal of excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and directed.
20
-
-
... More
S & F in reapair Lead Acid Battery 150AH For Solar Installation complete all as specified and directed.
4
-
-
... More
S&F MCCB in reapir , 160 Amps, 4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed.
1
-
-
... More
S&F MCCB in reapir , 200 Amps,4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed.
1
-
-
... More
S&F MCCB in reapir , 250 Amps,4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed.
1
-
-
... More
S&F MCCB in reapir , 350Amps,4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed.
1
-
-
... More
S&F MCCB in reapir , 400 Amps,4 Pole 36 KA ,415 Volts with thermal adjustment complete all as specified and as directed.
1
-
-
... More
S & F in repair automatic light timer switch with nature switch, infra ray sensor with pre dawn switching off timer, 8 hours of max load capacity of 4KW per phase. Degree of protection confirms to IP 65. Contactor rating - 40 Amps, MCB rating - 63 Amps, 3 Phase with max load 12 KW complete all as specified and directed.
1
-
-
... More
M&L for sheet metal enclosures distribution board where MCB to be used without but bar CL-IP-43 240V, 2 way single pole & neutral link & mounted on pole with clips properly complete as specified and directed.
15
-
-
... More
M& L in replacement GI tubing light grade incl. accessories for protection cable of size 40mm Bore complete all as specified & directed.
60
-
-
... More
Supply and fixing in replacement , bracket made out of 25 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as directed,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete.(Rates quoted by the contractor shall deemed to include for nut and bolts, fitting fixtures etc.)
10
-
-
... More
Supply & Fix in repair MCB single pole, 6 - 32 Amps 240V in `C’ series having current rating 10 KA complete all as specified and directed.
15
-
-
... More
Supply and Fix in repair cable FR PVC insulated PVC sheathed with multi stranded copper conductor of size 2.5 sq mm 2 core and connecting to the street light feeder complete all as specified and directed.
220
-
-
... More
M&L for LED flood light fitting 120 W for high mast lighting sys tem IP66 POC flood light aesthetically designed with better thermal management complete all as specified and directed.
8
-
-
... More
Supply and fixing in repair post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
8
-
-
... More
S & F in repair Bolard Led Light 10W, IP 66 Complete all as specified & directed.
8
-
-
... More
S&F PP-R Gate valve (brass insert) used in solar water heater complete all as specified and directed.
2
-
-
... More
Supply and laying bricks of size 230mmx115mmx75mm complete all as specifed and directed.