Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Solar Installation and Products
Eprocure
Opening Date21 Dec 2024
Closing Date18 Jan 2025
Tender Amount₹ 96,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply ,laying ,testing and commissinoning of LT, D C Cables(color code) as per IS 7098 part 1 guide Lines from SMB to inverter connections 800V 1Cx120 Sq.mm (red/black as per site requirement ) Annealed Tinned aluminiumr cables PVC insulation with required accessories like conduits,glands,cable tie ,ferrules as per requiremnt. Electrical Characterstics :- 1.Rated Insulation Voltage: 800 V AC 2. Insulation Rated DC Voltage: 1.1 kV 3 .Working Voltage: DC 800 V 6.Insulation Resistance: 1000 MW-km 7.Spark Test: 6000 Vac (8400 Vdc) 8.Voltage Withstand: 6500 V as per EN50395 for 5 min 9.Ampacity: According to requirements for cables for PV systems .

200

-

-

... More
S & F in repair of Low density poly ethylene pipes (LDPE) of pressure rating 6 kgf/m2 , size of 40 mm dia for cable protection complete all as specified and as directed.

450

-

-

... More
supply and fix HRC fuse 3 A ,1000 V DC all as specified and directed. Make : PV-3A10F of solar PV or eq to makes listed in command list

50

-

-

... More
supply and fix HRC fuse 16 A ,1000 V DC all as specified and directed. Make : PV-15A10F of solar PV.

150

-

-

... More
Supply and fix type 1+2 photovoltaic surge protection device having electrical characteristics. U cpv -1200 V DC ,Input current In - 20 kA ,I max - 40 kA to protect SMB ciruit wiring from high surge voltages all as specified. Make :- Citel/Havells

8

-

-

... More
Supply and fix dataline surge protection device having electrical characteristics. U c -15 V DC ,Up- 30 kV,In- 5 kA , Imax-20 kA , IL - 300 mA to protect SMB ciruit wiring from high surge voltages all as specified. Make :- Citel/Havells

8

-

-

... More
Supply and fix DC - DC converter for Input voltage 100 V- 1200 V, out put voltage V out - 24v ,I out - 6.25 mA to supply power for SMU card fitted in SMB and to other control circuit as per site requirement all as specified.

2

-

-

... More
Supply and fixing 3 pole switch disconnector of rated voltage 1000 V DC,rated current 200 A DC to fix in String monitor box all as specified and directed.

2

-

-

... More
Supply and fixing 3 pole switch disconnector of rated voltage 1000 V DC,rated current 400 A DC to fix in String monitor box all as specified and directed.

5

-

-

... More
AnnualMaintenanceContract(AMC)ofSCADAsystem Routine,Schedule&Breakdownmaintenance of SCADA equipments& functioning at RCC/CKP (Servers,PCs including softwares) of 6 MW solar plant.Supply of all inputs, replacement of defective cards,equipments,components of SCADA alongwith technological upgradation if required for maintaining the desired reliability of system (100%standbysupport). a) Bimonthly maintenance shall be strictly followed. All servicing should be done in accordance with approved drawings, maintenance instructions and specifications.System configuration and wiring shall not be generally changed/altered with respect to installed/present status unlessit is extremely necessary for suitable operation and normalization of system. After thorough servicing Contractor's representative shall record all the work done/pending or warning forwearing/ageing of equipments/components in the register. b) The contractor shall ensure smooth and trouble free operation of SCADA system during entire AMC period. However, if SCADA system does not meet the desired performance and defects continue to persist either due to operating system not upgraded & old version not supported or hardware components not available as obsolete, in these conditions, contractor shall upgrade the system at free of cost. b) Each breakdown or failure of any components or malfunctioning of equipments is to be explained by contractor alongwith remedial measures to be adopted to avoid such re-occurrence. C) Contractor’s representative shall be available to restore any failure /breakdownwithin minimum possible time. Abnormal status, Portmon data (if any) will be saved for analysisatalaterstage.If complaint not rectified within 48 hours after receiving complaint from depatment representatives either by written or telephonically or through whatsapp/mail ,contractor shall be liable to be recovered by deparment of penalty Rs 1000 per day upto proper rectification of breakdown all as directed by Engr in charge. Spare parts will be measured separately under respective items.

1

-

-

... More
Supply only Modbus RS485 to Ethernet Converter

6

-

-

... More
supply only Power Supply - 5 V DC

6

-

-

... More
Supply only Datalogger 128 GB

2

-

-

... More
Supply only Kernel SMU Card 24 Port String Monitoring Unit, 24 Channel, Each Channel Measuring Current: 25A, 1500VDC with RS485 Model No.: ST0N2025/NC

23

-

-

... More
supply only CAT-6 Cable( RS 481 cable)

300

-

-

... More
Supply onlyWireless Router - 8 port

1

-

-

... More
Annual maintance contract (AMC) (Level 2) from OEM,that provides inspection for comprehensive maintanance, preventive maintanance (Scheduled maintenance ,Recommendation to strategic spares ,Ageing components replacement ), corrective care (On call emergency breakdown maintenance), repair, retrofit, upgradation, and refurbishment field services, Remote Support (Phone/email) by OEM representatives to entire contract period for inverter of capacity 1000 KW.OEM reps shall visit site once in two months for routine preventive maintanance and with in 48 hours if emergency breakdown occurs.Maintenance shall include (but not limited to) Trouble Shooting of any reported faults, functional tests, recommendation for repairs and replacement, supervision of repairs based on the availability of spares. Contractor shall ensure minimum availability of spares at site during the preventive maintenance isit.Contractor will make available to OEM representatives, appropriate staff who are familiar with the equipment and provide suitable working space and facilities like blower, general tools and suitable safe storage for maintenance equipment. Contractor shalll be liable to ensure for continuoes working of inverter with out any breakdown. In case of emergency breakdown,contractor should make efforts to bring back the inverter to serviceable condition with in 48 hours after recieving complaint from department ,otherwise penalty will be imposed Rs 2000/day after completion of 48 hours.This item includes monthly servicing of inverter i:e opening of contactors,cleaning with blowers,cleaning of terminals , refixing of contactors, inspection of control wiring , MCBs, inspection of auxialiary supply ,tightning of loose connections etc whatever required for smooth functioning of inverter and contractor shall report to engr in charge if any abnormality found in inverter. Spares required during maintanance shall be measured and paid separately in respective items below. One Each job will be measured and paid for AMC of one inverter for one year.

5

-

-

... More
Supply only the following items :-

-

-

-

... More
FUSE - PV-10A10F, 1000V,10A

10

-

-

... More
FUSE - SC33AR55V20CTF, 550V,2000A

6

-

-

... More
FUSE - OFAA000GG63, 690V,63A

5

-

-

... More
FUSE - OFAA000GG40, 690V,40A

5

-

-

... More
TYPE 2 AC SPD

5

-

-

... More
TYPE 1+2 DC SPD

5

-

-

... More
POWER SUPPLY MCS-B 7.5-110-240/24

3

-

-

... More
PCB KIT NAMU-11 MAIN ASSEMBLY

1

-

-

... More
REV.A;CHARGING RESISTOR;CBH 335 C H 414

4

-

-

... More
FUSE - PV-20A10F, 1000V,20A

10

-

-

... More
FUSE - C14G16, 690V,16A

10

-

-

... More
PCB KIT MIRU-01

2

-

-

... More
FILTERING BOARD MEMI-01 EMI FILTER BOARD

4

-

-

... More
EMI FILTER BOARD MEMI-02

4

-

-

... More
ARRESTER TYPE-2 VAL-MS-400/3+0/VF-FM/32 -F51

4

-

-

... More
MEMORY UNIT KIT ZMU-02

2

-

-

... More
REV.B;CONTACTOR;AF750-30-22-68;-690V;-10

5

-

-

... More
REV.A;CONTACTOR;GAF750-10-11-68;1000V;87

5

-

-

... More
REV.A;PROTECTION SWITCH;S201-K8;6 KA;8 A

4

-

-

... More
REV.A;PROTECTION SWITCH ; S203-K6 ; 6 KA

4

-

-

... More
REV.A;PROTECTION SWITCH ; S203-K10 ; 6 K

5

-

-

... More
MB CAP 20/24 BUFFER MODUL

3

-

-

... More
FAN, AC Compact , W2E208BA2010

6

-

-

... More
3-PHASE TRANSF;3,0KVA 3LT4.00-23,DYN11

1

-

-

... More
FAN W2E143-AA0993, 220V, 50/60Hz

8

-

-

... More
REV.Q;FENA-21; FENA-21; ETHERNET; ASSEMB

3

-

-

... More
FUSE - PV-350AF3 1000 V;350 A; GPV;3;

20

-

-

... More
FILTER (AIR);AIR-TEX G-150;718X540;REV.A

15

-

-

... More
FILTER (AIR);CC-CM;518X540 AIR-TEX G-150

15

-

-

... More
FILTER (AIR);AIR-TEXT G-150 318X540;OWN_

15

-

-

... More
S&F LT air circuit breaker with microprocessor,fixed ype ,with current rating 2000Amp,rated voltage 690 V,Rated ultimate short circuit breaking capacity Ics at 690 V is 55 kA, at 415V rated voltage Ics is 65 kA & Ics = 100% Icu to fix in inveter all as specified and directed.

1

-

-

... More
Disconnections of out door type step up transformer 1000 KVA after taking shut down from the deptt. opening the top cover, taking out the top cover carrying out joint inspection with Engr-in-Charge for identifying the reason of leakage of transformer oil reconnections, re-filling oil upto required level and re-assembling the transformer and complete overhauling including testing including painting transformer with dark grey colour two coat if synthetic enameled paint over existing paint complete. Note :-i) cost of material and labour for various parts will be paid separately under respective items of Sch A. However cost of labour towards dismantling, assembling, joint inspection and identifying the fault is deemed to be included in this item. Cost of sundry items viz cover bolt, plug cap, screws, washer, air release plug etc are deemed to be included in quoted rate. (ii) Filtration / centrifuging of old transformer oil to be measured and paid separately. (iii)Addition/replacement of transformer oil if required will be measured and paid separately.

6

-

-

... More
M&L for on load filtration/configuration/desludging (in situ) of old carbonized insulating oil (Transformer oil) filled in transformers under service (both power and distribution type) of various capacities and rating outdoor type (0.4 / 33 kV ) located and installed at d6 MW solar plant by means of filtration plant (Machine) electric motor driven to improve the dielectric strength up to to 50 KV complete all as directed including filling / topping up insulating oil all as directed. ( Note : Testing of di-electric strength of insulating oil before & after filtration shall be carried out in presence of Engr in Charge / GE . The T&P/Labours required for filtration testing shall be arranged by the contractor at his own risk & cost.(Note : Date of filtration shall be stick on transformer rate are included in qouted rate.)

7000

-

-

... More
Supply and filling transformer oil having dielectric strength not less than 50 KV of approved make.

1500

-

-

... More
M&L in repair Silica gel assembly / breather each having threaded bore of size 15/20/25mm with new silica gel crystal clear for transformer of capacity upto 1000 KVA complete.

4

-

-

... More
M&L silica gel for transformer indoor/out door type

40

-

-

... More
Dismantling existing HT bushing with copper rod including disconnection of electrical connection and replacement of porcelain bushing vitreous, brown colour,33 KV grade along with a set of oil seals& copper alloy stud,nuts,washers etc of suitable size for primary side (HT side ) of outdoor type 33 KV for 1000 KVA power transformer of any make .

6

-

-

... More
S&F in repair Re-winding of Transformer 1000 KVA, 0.44/33 KV stepup power Transformer :- LV and HV Side winding coil total replaced, new coil assemble for HV and LV coil. All active spare insulated with proper insulation ovening of transformer new winding Assemble in Transformer, all gasket replacement of transformer, Testing of transformer after fitting top cover plate and connection. Painting trasformer body.

1

-

-

... More
Excavation in trenches in hard/dense soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe/pole etc or soil for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engr-in-Charge.

250

-

-

... More
Excavation in trenches in soft/disintegrated rock not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, laying of cable/pipe/pole etc or soil for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engr-in-Charge.

180

-

-

... More
Excavation in trenches in soft/disintegrated rock not exceeding 1.5m wide and depth exceeding 1.5m and n.exc 3.0 m for foundation, laying of cable/pipe/pole etc or soil for shaft, walls, cesspts, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified & directed by Engr-in-Charge.

0.5

-

-

... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick hard/dense soil complete all as specified & directed by Engr-in-Charge.

350.5

-

-

... More
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all as directed by Engr-in-Charge.

80

-

-

... More
M&L for sand cushioning to underground PVC/XLPE cable with tibba sand and punning to provide required cover complete all as directed by Engr-in-Charge. Note :- For the purpose of payment only punned thickness will be measured.

35

-

-

... More
Supply & laying 40 to 50 mm thick roughly hammer dressed Jodhpur stone patti cable cover 25 cm to 30 cm wide and n.exc 60 cm long each laid dry abutting with each other with maximum gap between adjacent slabs n.exc 10 mm complete all as specified & directed by Engineer-in-Charge.

150

-

-

... More
S&F repair ,40 mm bore GI tubing "light garde "in trenches on pole for protection of cables complete all as specified & directed by Enginner-in Charge .

20

-

-

... More
S&F repair ,100 mm bore GI tubing "light garde "in treches on pole for protection of cables complete all as specified & directed by Enginner-in Charge .

10

-

-

... More
S&F SMC in repair Junction box ,pole mounted for strret lighting for 3 Phase/4 core system of size 275 X135X110mm top hinged,door fixed to base with hinges on top including necessary MS clamps - 02 nos,nut bolts etc. MAKE:- Cat no-GS-JB-3016-T of Sintex or Equivalent.

20

-

-

... More
Supply and fixing in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver with separate surge protection device 5ka rating , lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete and sepatate connector block for termination of incomming cable connection all as specified and directed by Engr -in- Charge. Make Crompton Greaves, Wipro, Havells

15

-

-

... More
Supply & erect in repair in position steel tubular pole swagged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 31 , 09 mtrs long incl painting with two coats of aluminium paint over a coat of red oxide paint all as directed including removing existing pole. ( Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately) Make : Electrosteel/ Indian Pole/ Singh Profiles/ Kalki tubes & Poles

5

-

-

... More
Supply & erect in repair in position steel tubular pole swagged type as per IS 2713 complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 55 , 11 mtrs long incl painting with two coats of aluminium paint over a coat of red oxide paint all as directed including removing existing pole. ( Note :- Excavation and earth work and PCC in foundation shall be measured and paid separately) Make : Electrosteel/ Indian Pole/ Singh Profiles/ Kalki tubes & Poles

2

-

-

... More
Demolition of PCC coping , base , etc any type

4.5

-

-

... More
M&L for provision of PCC 1:4:8, type D2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified and as directed.

0.5

-

-

... More
M & L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in plinth, platforms, pole coping etc., all as specified and as directed.

4

-

-

... More
Material and labour for replacement of unserviceable street light bracket made out of GI pipe 1.2 mtr long 40mm dia medium grade bent to shape as directed including MS clamps made out of 40mmX6mm flat iron for fixing bracket suitable for PCC/ street poles including nuts and bolts of required size all as directed incl taking down of old unserviceable bracket.

15

-

-

... More
Taking down/out unserviceable LT/HT UG Cable of any descriptions, laid in trenches and/or fixing with Walls/Poles complete all as specified and as directed.

600

-

-

... More
Supply and lay cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 33000 Volt grade with stranded aluminium conductor of size 185 Sqmm 3.0 Core complete all as specified and directed.

50

-

-

... More
Supply, lay, test and commissioning of LTUG, XLPE insulated, heavy duty, 1100V grade of size 25 Sqmm 4 core electric cable with aluminum conductor, served with an inner sheathing of PVC tape armored with galvanized steel wire or tape and overall PVC sheathed, laid in trenches or passing through pipe, making all connections with and including provision of necessary glands, lugs, bushing etc as required complete all as specified and as directed by Engineer-in-Charge Note : Earthwork excavation sand cushioning ,Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items

150

-

-

... More
All as per item No 9 above but of size 16 sq mm. 4 core

400

-

-

... More
M&L cable Jointing kit for 33 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and as directed by Engineer-in-Charge.

2

-

-

... More
M&L cable Jointing kit for 33 KV (Earthed) grade cable for oudoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified and as directed by Engineer-in-Charge

2

-

-

... More
M&L cable Jointing kit for 33 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 Sqmm complete all as specified & directed by Engr-in-Charge.

4

-

-

... More
Supply, Fixing Testing and Commissioning of ALL in ONE Solar LED Street Light Fixture of 40 Watt in Single Piece Extruded Aluminium Housing IP-65 IK 08, encases with Solar PV Panel of Capacity 30Wp Mono Crystalline at PSH 4hrs, Battery type and Size - 12.8V-18Ah (LiFePO4), Luminance Efficacy 150 lumens/Watt , CRI 70, Dimming Facility With PIR Sensor Which works as Follows - 1 st 1 Hrs on motion 100% and without 25% brightness next 4 Hrs on motion 40% and without 25% brightness next 6 Hrs 25% irrespective of motion final 1 Hrs on motion 40% & without 25% (Till Dawn Condition). CCT - 5700 to 6500 K. The Charge controller cum driver Must be MPPT Charge Controller with silicon potted ( Potted Type ) with Efficiency (of the electronics) 90%, Duty Cycle - Dusk to Dawn (12hours) and other safety features like - External switch (IP-66) to On/Off , Protections for reverse flow of current through the PV Module, Battery Overcharge & deep discharge cut off The Manufacturer of the Fixture must have it's own in house NABL Accredited Lab and Must produce it's certificate with at least 1 year validity of that ertificate and also Lm-79, Lm-80 , Test Certificate Etc. As per Make - Wipro/Crompton/Philips

10

-

-

... More
Supply and fix in repair of tubular battery 12 Volts 180 Ah incuding termination lead complete all as specified and directed by Engr -in-in Charge. Make : Exide or equivalent

3

-

-

... More
Supply only disttilled water for batteries all as specified and directed

100

-

-

... More
Supply only sulphuric acid for filling up of batteries.

50

-

-

... More
S&F Termination lead for batteries as per site requirement and directed.

200

-

-

... More
Supply &fix in repair of 5 KVA power pack for battery back up input 230 volt AC output 220 volt ,battery voltage 24v DC or as per site requirement complete all as specified and directed. Make Alan or equivalent

1

-

-

... More
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate & salt up to ground level connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including all necessary earth work, excavation, earth chamber with PCC 1:3:6, type C1 and RCC chamber cover of PCC 1:2:4 with handle and 20mm dia GI watering pipe with funnel and wire mesh etc and testing on complete all as specified and directed by Engr-in-charge.

6

-

-

... More
Material and labour for substation yard spreading levelling with 20 mm graded coarse aggregate / gravells laid approximately 75 mm thick layers near VCB/Transformer /2/4 pole structure and plateform etc all as directed.

15

-

-

... More
Cutting & trimming of tree trunks/ branches falling on or likely to fall on LT/HT over head electrical line for clearence of 3.0 meter on ground from the nearest conductor/pole /earth etc .& disposal of unservicable materials to distance not exc.50 mtrs .& clearing of site all as directed by Engr -in-Charge. Note:- The distance between two poles is measured as one span.

35

-

-

... More
Taking down cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section (MS channel, angle sections, flat, round or square bars ) from existing structures including removing of bolts nuts & washers etc alongwith necessary tools and equipment for workers all as specified and directed by Engr in charge.

0.3

-

-

... More
M&L cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section (MS channel, angle sections, flat, round or square bars ) for reqd sizes and shape including bolts nuts & washers welding bending cutting cold or hot drilling holes for inserting in any shape or size as indicated or directed complete incl painting ( one red oxide primer coat two coats of aluminium paint ) complete.

0.15

-

-

... More
Refixing of cross arms, bracing supports, clamps, back plates, hooks etc fabricated from structural steel section (MS channel, angle sections, flat, round or square bars ) for reqd sizes and shape including bolts nuts & washers welding bending cutting cold or hot drilling holes for inserting in any shape or size as indicated or directed complete incl painting ( one red oxide primer coat two coats of aluminium paint ) complete on same structure or on any new structure all as specified and directed by Engr in carhge.

0.15

-

-

... More
M&L for road cutting and making good with PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) complete all as directed by Enger -in- charge.

1

-

-

... More
M&L bore earthing not less than 200 mm dia 300 feet deep filled with black soil up to 50 feet from bottom complete with galvanized iron pipe 100 mm bore medium grade 6 meter long flanged at bottom & boltted/nuts & provided 12 mm holes (staggered) at centre to centre upto 250 feet complete length, burried directly in ground filled with 10 mtr alternate layer of chemical magnisium sulphate & salt up to ground level duly clamped on ground connected to galvanized iron strip 50x6 mm as earthing lead by means of bolt and nut, check nuts and brazing/welding, check nuts and washer of galvanized iron or steel including brazing work and 100mm dia light grade pipe for earth lead protection and testing on completion upto transformer neutral complete with funnel, earthing chamber and earthing lid cover and including taking down existing earthing of any description complete all as specified and directed by Engineer-in-charge. NOTE:- [i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M [ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways. [iii]. Main earthing strip from earth electrode to test point upto 7.5 mtr. [iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd. [v]. GI protection pipe of size 80 mm bore light grade 7.5m.

4

-

-

... More
Caliberation/Servicing/Overhauling & testing and commissioning of factory manufactured, HT 33 KV Phase 3 wire 50 C/S 400 Amps, 18.4 KA single panel switch board, vertical isolation and horizental draw out type vaccum circuit breaker (VCB) confirming to IS-13118, EIC-56 totally enclosed, single busbar floor mounting metal clad indoor extendible fully interlock complte comprising the following :- (a) CTs primary current injection test . (b) IR values of CTs (c) Ratio test of PTs and IR value (d) Protection relays testing through secondary current injection kit (e) Voltmeter, ammeter functional tesing (f) Breaker tesing for tripping time, closing time, contact resistance values and physically healthyness of Vaccum interuptor. Note:- 1. Wiring of Control Panels of VCBs, wiring of WTI, OTI, CTs, PTs will be including quoted rate. 2. Contractor will be responsible for arranging the expert for checking and rectification/Alteration of control wiring of safety relays. 3. spare parts will be mesured and paid separately. 4. Its contractor responsibility to ensure smooth and proper functioning of VCB in between time of visits by OEM reps.

6

-

-

... More
S&F in repair, annunciator relay box consisting of 4/6 block 18 to 90 volts DC complete in existing 33 kV VCB of ABB make all as specified & directed by Engr-in-Charge. (Make :- Minilec/Alan or equivalent as approved by GE).

3

-

-

... More
S&F in repair, master trip relay 30 Volts DC complete in existing VCB of ABB make all as specified & directed by Engr-in-charge. (Make :- Easun Reyrolle

2

-

-

... More
S&F in repair, over current relay 135 Volts DC complete in existing VCB of ABB make all as specified & directed by Engr-in-charge.

3

-

-

... More
S&F in repair, auxilary relay 110 Volts DC complete in existing VCB of ABB make all as specified & directed by Engr-in-Charge. (Make :- Ashida/Easuna Reyrolle Model No. B33X3 or Areva).

3

-

-

... More
S&F in repair, multi functional meter for 33 KV VCB complete in existing VCB of ABB make all as specified & directed by Engr-in-Charge.

2

-

-

... More
Supply and fixing in repair of over current and earth fault IDMT protection relay (digital relay) ,110 Volts complete necessary connection and testing in existing VCB of ABB make all as specified and directed by Engr-in-charge. (Make : ABB).

2

-

-

... More
Supply and fixing in repair universal motor (spring charge for 33 KV VCB) 220 volt AC/DC type PMR5 in existing VCB of ABB

2

-

-

... More
Renewal of PT fuse suitable for 33 KV in existing VCB of ABB make complete all as specified and directed by Engr-in-Charge.

3

-

-

... More
Disconnecting the electrical connections of unserviceable electrical motor and shifting to work shop.Taking out burnt winding coils from stator body cleaning of slots with soft wire brush and rewinding by using super enameled copper wire of existing size & gauge, heat and varnishing complete and M&L winding with super enamal copper wire of existing gauge including greasing, varnishing and alike testing complete for electric motors of capacity 5 HP all as specified and directed by Engr in charge.

3

-

-

... More
Taking up/down undermentioned capacity of Open Well submersible pump set including detecting of defective parts and replacing the same with new parts complete: Note:1) The rate quoted by the tenderer includes all cost of necessary nut bolts washers and alike if not included in Sch A 2) All new parts required will be measured and paid separately as supply only. 3) The rate quoted by the tenderer also includes cost for taking out pump from the well 20m depth from GL and again lowering the same in its original level and alignment complete. 4)The rate quoted by the tenderer also includes removing of joints of pipes of any dia and refixing the same to its original positon with gasket nut bolts, threading, clamps,and alike complete 5)The size of wiring to be incorporated in the work shall be as per existing one hence contractor is requested to visit the site and to get acquanted with site conditions complete

3

-

-

... More
Pump shaft.

2

-

-

... More
DE/NDE Bearing.

4

-

-

... More
shaft bush.

2

-

-

... More
shaft coupling.

2

-

-

... More
M & L in repair 20 mm dia Gl steel tube Medium grade galvanized with all fitting laid in trenches/ on wall/ ceiling/ roof complete and all as specified and directed by Engr in charge.:- Make : Jaindal/ Tata/ Prakash Surya/ Ravindra./Swastik

50

-

-

... More
M&L for fixing of PVC hose pipe inner dia 20mm,outer dia 25 mm dia,max working pressure 39 bar,conforming to BS 3746,withstanding temparatures from -15 C to 65 C.Rate includes fixing of hose pipe to existing GI pipe with necessary fittings as per site requirement all as specified and directed by Engr in charge.

120

-

-

... More
Supply and fix solar panel cleaning kit with aluminium extension pole consists of 4mtr extension pole,brush 45 cm -01 no,hose pipe 18 feet,water supply valve 1 no,Y joint 3 No all as specified and directed by Engr in charge.

3

-

-

... More
M&L for cleaning of solar panel with water of 6 MW solar plant consisting of 19500 solar panels. water will be supplied by MES through existing GI pipe lines and connecting & disconnecting of hose pipes is the responsibility of contractor's labour. Necessary tools and fittings shall be supplied by contractor.Surface of panel after cleaning should be very clean and transparent and no dust should remain on surface of panels.cleaning shall be all as specified and directed by Engr in charge. Note :- The gap between two consecutive cleaning should not be more than 15 days.Log book shall be maintained for cleaning as per format directed by Engr in charge and signed by site incharge after completion of every cycle of cleaning.solar panels damaged while cleaning shall be replaced by contractor at his own risk and cost.

10

-

-

... More
M&L for gross cutting with machine in solar plant upto ground level for removal of grass,weeds & small bushes including provision of gross cutting machine.Contractor shall take care of existing cables from damage.Damaged cables while gross cutting shall replace by contractor at his own risk and cost.Necessary machines and tools shall be provided by contractor for gross cutting. All debris shall be collected and dumped out of the premises of solar plant and make ground clean in the premises of solar plant.

2000

-

-

... More
Annual maintance contract (AMC) from OEM,that provides inspection for comprehensive maintanance, preventive maintanance (Scheduled maintenance ,Recommendation to strategic spares ,Ageing components replacement ), corrective care (On call emergency breakdown maintenance), repair, retrofit, upgradation, and refurbishment field services, Remote Support (Phone/email) by OEM representatives to entire contract period for solar roof top system of capacity 60/30 KVA consists of 10/15 KVA(11 no) inverters and back up batteries.OEM reps shall visit site once in two months for routine preventive maintanance and with in 48 hours if emergency breakdown occurs.Maintenance shall include (but not limited to) Trouble Shooting of any reported faults, functional tests, recommendation for repairs and replacement, supervision of repairs based on the availability of spares. Contractor shall ensure minimum availability of spares at site during the preventive maintenance isit.Contractor will make available to OEM representatives, appropriate staff who are familiar with the equipment and provide suitable working space and facilities like blower, general tools and suitable safe storage for maintenance equipment. Contractor shalll be liable to ensure for continuoes working of inverter with out any breakdown. In case of emergency breakdown,contractor should make efforts to bring back the inverter to serviceable condition with in 48 hours after recieving complaint from department ,otherwise penalty will be imposed Rs 1000/day after completion of 48 hours.This item includes monthly servicing of inverter i:e cleaning with blower,inspection of control wiring,cards,PCBs,transformer,SCR modules,inspection and cleaning of battery bank,replacement of defective battery terminals&batteries , tightning of loose connections charging of discharged batteries ,inspection solar panels , connections & rectifications etc whatever required for smooth functioning of inverter and contractor shall report to engr in charge if any abnormality found in inverter. Spares required during maintanance shall be measured and paid separately in respective items below. One Each job will be measured and paid for AMC of one roop top solar system for one year.

3

-

-

... More
S & F in repair controller PCB card suitable for 3 Phase10 KVA(Make Kaco)/15 KVA (Compatible to Make:- Enertech UPS pvt ltd) SOLAR PCU AC input 360-460V &AC output 400v/230V AC,50 Hz, PV range 130-200V,battery DC 96V/360V complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repair controller PCB programing card suitable for 3 Phase10 KVA(Compatible to Make Kaco)/15 KVA (Make :-Enertech UPS pvt ltd) SOLAR PCU AC input 360-460V &AC output 400v/230V AC,50 Hz, PV range 130-200V,battery DC 96V/360v complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repair Charging card suitable for 3 Phase10 KVA(Make Kaco)/15 KVA (Compatible to Make :-Enertech UPS pvt ltd) SOLAR PCU AC input 360-460V &AC output 400v/230V AC,50 Hz, PV range 130-200V,battery DC 96V /360v complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repair Driver card suitable for 3 Phase10 KVA(Make Kaco)/15 KVA (Compatible to Make :-Enertech UPS pvt ltd) PCU AC input 360-460V &AC output 400V/230v AC,50 Hz, PV range 130-200V,battery DC 96V/360v complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repair solar Driver card suitable for 3 Phase10 KVA(Make Kaco)/15 KVA (Compatible to Make :-Enertech UPS pvt ltd) PCU AC input 360-460V &AC output 400v/230V AC,50 Hz, PV range 130-200V,battery DC 96V/360v complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repair SMPS card suitable for 3 Phase10 KVA(Make Kaco)/15 KVA (Compatible to Make :-Enertech UPS pvt ltd) AC input 360-460V &AC output 400v/230V AC,50 Hz, PV range 130-200V,battery DC 96V/360v complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repair IGBT card suitable for 3 Phase10 KVA(Make Kaco)/15 KVA (Compatible to Make :-Enertech UPS pvt ltd) PCU AC input 360-460V &AC output 400v/230V AC,50 Hz, PV range 130-200V,battery DC 96V/360v complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repair SCR moduler suitable for 3 Phase10 KVA(Make Kaco)/15 KVA (Compatible to Make :-Enertech UPS pvt ltd) PCU AC input 360-460V &AC output 400v /230V AC,50 Hz, PV range 130-200V,battery DC 96V /360v complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repair Transformer suitable for 3 Phase10 KVA(Make Kaco)/15 KVA (Compatible to Make :-Enertech UPS pvt ltd) PCU AC input 360-460V &AC output 400v/230v AC,50 Hz, PV range 130-200V,battery DC 96V/360v complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S & F in repair condenser suitable for 13 Phase10 KVA(Make Kaco)/15 KVA (Compatible to Make :-Enertech UPS pvt ltd) PCU AC input 360-460V &AC output 400v/230v AC,50 Hz, PV range 130-200V,battery DC 96V/360v complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
S&F in repair over/under voltage relay single phase 230v AC , trip delay 0-10s as per site complete all as specified and directed by Engineer-in-Charge.

2

-

-

... More
Supply and fix in repair of tubular battery cell 2 Volts 800 Ah suitable for battery bank 800 Ah incuding termination lead complete all as specified and directed by Engr -in-in Charge.

6

-

-

... More
Supply ,laying ,testing and commissinoning of LT, D C Cables as per IS 7098 part 1 guide Lines for connection of batteries in series/parallel , having rating voltage 96V 1Cx50 Sq.mm Annealed Tinned multi stranded Copper cables with required accessories like conduits,glands,cable tie ,ferrules as per requiremnt.

25

-

-

... More
Supply and fix in repair of laid acid battery 12 Volts 42 Ah incuding termination lead complete all as specified and directed by Engr -in-in Charge. Make : Exide or equivalent

5

-

-

... More
Supply and fix in repair of Laid acid battery 12 Volts 26 Ah incuding termination lead complete all as specified and directed by Engr -in-in Charge. Make : Exide or equivalent

5

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.