Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date23 Dec 2024
Closing Date13 Jan 2025
Tender Amount₹ 40,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply only electronic driver suitable for LED flood lights of capacity 120 watt to 150 watts as per existing complete all as required at site

70

-

-

... More
Supply only electronic driver suitable for LED flood lights of capacity 200 watt to 250 watts as per existing complete all as required at site

20

-

-

... More
Supply only electronic driver suitable for LED bollard/garden lights of capacity 8 watt to 10 watts as per existing complete all as required at site

40

-

-

... More
Supply only surge protection device 10 KV, suitable for LED street lights of capacity 45 watt to 250 watts, single phase, 230 volts, 50 hz complete all as specified and directed

150

-

-

... More
Supply, fixing and connecting elastomer insulated, flat,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 including taking down of old unserviceable connection wire complete all as specified and directed

415

-

-

... More
Supply and fix junction box made out of Fiber reinforced plastic with IP 55/IP 65 protection of size not less 200 x 140 x 95 mm (in side dimensions) , having 5 way terminals mounted on din rail for termination of cable with necessary nuts and bolts , including -02 Nos cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps, in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.

28

-

-

... More
Supply and fix junction box made out of fiber reinforced plastic with IP 55/IP 65 protection of in side size not less 350 x 250 x 140 mm (In side dimensions) , having 5 way terminals suitable for 70 to 95 sqmm 3.5 core cable, mounted on din rail for termination of cable with necessary nuts and bolts , including -02 Nos cable gland , 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps, in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.

50

-

-

... More
Supplying and fixing 1100 volts grade heavy duty, 10sqmm twin core cable, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm in and including taking down of old service connection compete all as specified and directed.

500

-

-

... More
S&F in replacement 3 Layer PPR Pipes, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete for outer dia 20 mm (PN-16) complete all as specified and directed.

100

-

-

... More
Supply, fixing, connecting and testing in repair Energy efficient LED street light fittings of capacity 45 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection , individuals LED's should have lenses for better throw across &along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector inbuilt in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance in and includings making electrical connections and taking down of old unserviceable light fitting of any type complete all as directed.

35

-

-

... More
Supply, fixing, connecting and testing in repair Energy efficient LED street light fittings of capacity not less than 60 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection , individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector inbuilt in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance in and includings making electrical connections and taking down of old unserviceable light fitting of any type complete all as directed.

70

-

-

... More
Supply, fixing, connecting and testing in repair Energy efficient LED street light fittings of capacity not less than 70 Watt, pressure die cast alluminium housing & toughened glass with IP-66 degree of protection , individuals LED's should have lenses for better throw across & along road range 140-280 volts fittings should be provided 10 KV surge protection external and apart from this surge, arrestor driver should have additional 4 KV surge protector inbuilt in driver for maximised protections, should have lumens output of 110 lumens watt minium protections facility in drivers, driver should be potted type for viberation proof performance in and includings making electrical connections and taking down of old unserviceable light fitting of any type complete all as directed.

50

-

-

... More
Supply, fixing, connecting and testing in repair Supply only, LED flood light of capacity 120 watt, aesthetically design, having epoxy powder coated pressure die cast aluminium housing with IP 66 protection efficient high output emitter LED for better thermal management of capacity 150W(5700K CCT) , individuals LED's should have lenses for better throw across, system luminous efficacy lm/w grater than or equal to 100lm/w, high efficiency long life LED module with SMD LED package mounted on MCPCB, viewing angle 120 degree, high quality toughened glass cover, IK 07 powered by 02 Nos , inetgral , isolated electronic LED drivers (SMPS based constant current supply) with lower THD output open/short circuit protection, over voltage protection, surge voltage, protection with SPD not less than 10 KV and other sagety test as Per IS-15885 part -2/sec 13, the LED flood light should be LM 79 report and IES file in and includings making electrical connections and taking down of old unserviceable light fitting of any type complete all as directed.

18

-

-

... More
Supply, fixing, connecting and testing in repair Supply only, LED flood light of capacity 150 watt, aesthetically design, having epoxy powder coated pressure die cast aluminium housing with IP 66 protection efficient high output emitter LED for better thermal management of capacity 150W(5700K CCT) , individuals LED's should have lenses for better throw across, system luminous efficacy lm/w grater than or equal to 100lm/w, high efficiency long life LED module with SMD LED package mounted on MCPCB, viewing angle 120 degree, high quality toughened glass cover, IK 07 powered by 02 Nos , inetgral , isolated electronic LED drivers (SMPS based constant current supply) with lower THD output open/short circuit protection, over voltage protection, surge voltage, protection with SPD not less than 10 KV and other sagety test as Per IS-15885 part -2/sec 13, the LED flood light should be LM 79 report and IES file in and includings making electrical connections and taking down of old unserviceable light fitting of any type complete all as directed.

20

-

-

... More
Supply, fixing, connecting and testing in repair LED bollard light decorative type in cylinderical shape with opel acrylic diffuser and IP 66 protection with reflector not less than 09 watt, not less 600mm height complete in and includings making electrical connections and taking down of old unserviceable light fitting of any type complete all as directed.

20

-

-

... More
Supply, fixing, connecting and testing in repair LED bollard light decorative type with reflector not less than 10 watt, IP65 rated Inverted Pyramid Tripod type, having Height not less 800mm LED Bollard with soft 360 deg light distribution in and includings making electrical connections and taking down of old unserviceable light fitting of any type complete all as directed.

25

-

-

... More
Supply, fixing, connecting and testing in repair energy efficient LED Post top light fittings made in die cast aluminium bottom and spun aluminium to reflector with decorative clear acylic diffuser and IP65 protection, with higher efficiency lighting of capacity not less than 25 Watt, range 140-280 volts with surge protection inbuilt in driver for maximised protections, driver should be potted type for viberation proof performancein and includings making electrical connections and taking down of old unserviceable light fitting of any type complete all as directed.

16

-

-

... More
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in any type of soil complete all as directed at site.

180

-

-

... More
M&L for tibba sand for cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engineer-in- Charge.

105

-

-

... More
M&L for 40 to 50 mm thick rough dressed Jodhpur type stone slab 25 to 35 cm in width of 80 cm long laid dry abutting each other for protection to under ground cable including taking down complete all as specified and directed.

1625

-

-

... More
M&L for Removing excavated material to a distance n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.

149

-

-

... More
M&L for Returning , filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.

31

-

-

... More
Supply,laying or fixing or passing through GI pipe, commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out /dismantling of existing cable. (a) 10 Sqmm 2 core Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-

500

-

-

... More
(b) -Ditto- all as per item No-26 above but 16 Sqmm 4 core

450

-

-

... More
(c) -Ditto- all as per item No-26 above but 25 Sqmm 4 core

500

-

-

... More
M&L for GI Tubes, of following size, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc in and including taking down of existing pipe complete all as specified and as directed. (a) 40 mm bore

40

-

-

... More
(b) -Ditto- all as per item No-27 above but 50 mm bore

20

-

-

... More
Taking out existing PCC/steel tubular LT electric poles of any length including breaking of cement concrete, necessary excavation and earth work, dismantling cross arms, M.S. clamps, insulators etc and carefully taking down existing over head conductors.

10

-

-

... More
Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 31 of 9 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emebeded portion shall be painted with two coat of black bituminous paint all as specified in IS with following specifications:- (i) Excavation in trenches in any types of soil ,returning filling in & well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation bedding of size 600x600mm, 200mm base all as specified and directed . (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level of size 600x600mm for casing of pole upto planting depth. (iv) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work above GL level. (v) Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed by Engr-in-charge.

10

-

-

... More
Dismantling/ taking down of existing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is 30 lux and for switching off 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed by the Engineer-in-Charge. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent

3

-

-

... More
Drilling (Horizontally) existing road ( Maximum 10 mtr wide) suitable for passing GI tubing upto 80/100mm complete all as specified and directed.

20

-

-

... More
M&L for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles, path to LT panels, bollard light(bollard lights to be refixed after repair to base) and other indicated work including necessary form work and finished the surface and including dismantling of old unseerviceable PCC complete all as specified and directed by Engineer-in-Charge.

4

-

-

... More
M&L for earthing complete with galvanised steel earth plate electrode 600X600X6mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below the ground level with top edge of earth plate not less than 1.5 mtr below normal ground level) connected to galvanised earth wire 4mm dia as earthing lead by means of bolts, nuts, chuck nuts and washers of GI or steel all as shown in electrical plate No 3 of SSR-2009 (Part-I) including charcoal dust common salt, 20mm bore GI medium grade watering pipe funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth lead including PCC pit 1:2:4 type B-1 using 20mm graded stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm steel bars 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-Charge and testing for required value in and including taking out of existing earthing complete all as specified and directed at site. Note:- If earth resistance of earthing is not found satisfactory it will be redone by the contractor on his risk and cost.

4

-

-

... More
Supply and fixing in replacement , street/security light bracket made out of 40 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete.(Rates quoted by the contractor shall deemed to include for nut and bolts).

25

-

-

... More
Supply and fixing in replacement , street/security light bracket made out of 25 mm dia galvanized steel tubing medium grade 1.5 m long including bending if required as direct ,02 nos clamps made out of MS flat iron 40X6mm of suitable size fixed with bolts, nuts and washer including drilling holes and grouting with the same for fixing bolts complete.(Rates quoted by the contractor shall deemed to include for nut and bolts).

18

-

-

... More
S&F for MS Cross arms , bracing, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding , bending, cold or hot, drilling holes or bolt in any shape or size including 2 coats of aluminium paint over a coat of red oxide primer in and including taking down of old cross arms complete all as specified and directed by Engineer-in-Charge. Note:- Unexposed surface shall be given one coat of primer only.

1.3

-

-

... More
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991). (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed. (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.

5

-

-

... More
Disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump/mono block pump set of following capacity, electric driven 3 phase 415 volt and replacement of worn out spare parts including replacement of new gland packing and re-assembling, installation in the same location, commissioning & testing complete all as directed and directed. Notes:- (i) The spare parts required to be replaced shall be measured and paid for separately under the relevant items here-in-after. (ii) Unit rate (quoted by the tenderer) shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. (a) Centrifugal pump/mono block pump set of capacity 100/75 HP

6

-

-

... More
(b) -Ditto- all item as per 38.00 above but Centrifugal pump/mono block pump set of capacity 60 HP

4

-

-

... More
(c) -Ditto- all item as per 38.00 above but Centrifugal pump/mono block pump set of capacity 40 HP

6

-

-

... More
(d) -Ditto- all item as per 38.00 above but Centrifugal pump/mono block pump set of capacity 30 HP

4

-

-

... More
(e) -Ditto- all item as per 38.00 above but Centrifugal pump/mono block pump set of capacity 20 HP

4

-

-

... More
(f) -Ditto- all item as per 38.00 above but Centrifugal pump/mono block pump set of capacity 15/12.5 HP

6

-

-

... More
(g) -Ditto- all item as per 38.00 above but Centrifugal pump/mono block pump set of capacity 7.5 HP

4

-

-

... More
(h) -Ditto- all item as per 38.00 above but Centrifugal pump/mono block pump set of capacity 5 HP

14

-

-

... More
(j) -Ditto- all item as per 38.00 above but Centrifugal pump/mono block pump set of capacity 2 HP and 3 HP

4

-

-

... More
Taking out existing unservicable submersible pump and motor of capacity 5 HP to 15 HP, 3 phase, 415 volts, electric driven bore well and disconnecting electrical connections and delivery out let pipe and dismantling the motor and pump set complete and lowering in bore well after repairing/replacement of spares parts including mechanical seal and nuts/bolts/washers of the same and testing including refixing of column pipes, submersible cables complete all as specified and directed. Notes : Repair work and spare parts of pumps and motor shall be measured and paid for separately under relevant items here-in-after.

5

-

-

... More
Taking out existing unservicable submersible pump and motor of capacity 15 HP to 30 HP, 3 phase, 415 volts, electric driven bore well and disconnecting electrical connections and delivery out let pipe and dismantling the motor and pump set complete and lowering in bore well after repairing/replacement of spares parts including mechanical seal and nuts/bolts/washers of the same and testing including refixing of column pipes, submersible cables complete all as specified and directed. Notes : Repair work and spare parts of pumps and motor shall be measured and paid for separately under relevant items here-in-after.

14

-

-

... More
Opening and reassembling of monoblock/centrifugal pump (motor) after rewinding & replacement of worn out spare parts including taking out the burnt winding and rewinding of monoblock/centrifugal pump (motor) following capacity, Three Phase, 415 volts with solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing including insulation material, minor spares and replacement of unserviceable spare parts and reassembling the components & testing for function ability, complete, all as specified & directed. Notes:- (i) The spare parts required to be replaced shall be measured and paid for separately under the relevant items here-in-after. (ii) Unit rate (quoted by the tenderer) shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding. (a) Monoblock/Centrifugal pump (Motor) 100 HP capacity, 3 phase, 415 Volt, 50 Hz

2

-

-

... More
(b) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 75 HP capacity, 3 phase, 415 Volt, 50 Hz

2

-

-

... More
(c) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 60 HP capacity, 3 phase, 415 Volt, 50 Hz

2

-

-

... More
(d) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 40 HP capacity, 3 phase, 415 Volt, 50 Hz

2

-

-

... More
(e) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 30 HP capacity, 3 phase, 415 Volt, 50 Hz

2

-

-

... More
(f) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 20 HP capacity, 3 phase, 415 Volt, 50 Hz

2

-

-

... More
(g) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 15/12.5 HP capacity, 3 phase, 415 Volt, 50 Hz

4

-

-

... More
(h) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 7.5 HP capacity, 3 phase, 415 Volt, 50 Hz

3

-

-

... More
(j) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 5 HP capacity, 3 phase, 415 Volt, 50 Hz

6

-

-

... More
(k) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 2 HP to 3 HP capacity, 3 phase, 415 Volt, 50 Hz

3

-

-

... More
(l) -Ditto all item as per 41.00 above but Monoblock/Centrifugal pump (Motor) 1 HP capacity, 3 phase, 415 Volt, 50 Hz

2

-

-

... More
Opening and reassembling of submersible motor after rewinding and replacement of worn out spare parts including taking out the burnt winding and rewinding of submersible motor 5 HP to 15 HP, Three Phase, 415 volts with solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing including insulation material, minor spares and replacement of unserviceable spare parts and reassembling the components & testing for function ability, complete all as specified and directed. Notes: (i) The include opening of motor at site for damaging of existing stator winding if found burnt/damaged in front of concerned JE/AGE (E/M) after testing on site before taking to work shop outside MD land. Motors will be given for repairing as per the site condition and need for repair being maintenance work. (ii) The spare parts required to be replaced shall be measured and paid for separately under the relevant items here-in-after. (iii) Unit rate (quoted by the tenderer) shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.

3

-

-

... More
Opening and reassembling of submersible motor after rewinding and replacement of worn out spare parts including taking out the burnt winding and rewinding of submersible motor 15 HP to 30 HP, Three Phase, 415 volts with solid copper conductor (wire) superior quality of approved make, size & number of wire as per existing including insulation material, minor spares and replacement of unserviceable spare parts and reassembling the components & testing for function ability, complete all as specified and directed. Notes: (i) The include opening of motor at site for damaging of existing stator winding if found burnt/damaged in front of concerned JE/AGE (E/M) after testing on site before taking to work shop outside MD land. Motors will be given for repairing as per the site condition and need for repair being maintenance work. (ii) The spare parts required to be replaced shall be measured and paid for separately under the relevant items here-in-after. (iii) Unit rate (quoted by the tenderer) shall be deemed to include for all minor spares/extras. The decision of Accepting officer regarding minor spares/extras shall be final, conclusive and binding.

6

-

-

... More
Supply and fixing in repair/replacement of following parts for existing centrifugal /Monoblock pump set electric driven 3 phase 415 volt complete all as specified and directed. (a) S&F in replacement of Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 100 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.

2

-

-

... More
(b) -Ditto- all as per item 44.00 above but S&F in replacement of Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 75 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.

3

-

-

... More
(c) -Ditto- all as per item 44.00 above but S&F in replacement of Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 60 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.

3

-

-

... More
(d) -Ditto- all as per item 44.00 above but S&F in replacement of Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 40 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.

4

-

-

... More
(e) -Ditto- all as per item 44.00 above but S&F in replacement of Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 30/20 HP Pump (Primary and secondary). Make : SKF /NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.

4

-

-

... More
(f) -Ditto- all as per item 44.00 above but S&F in replacement of Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 15/12.5 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.

6

-

-

... More
(g) -Ditto- all as per item 44.00 above but S&F in replacement of Deep Groove Ball/Roller bearing (Double sealed Ball bearing) for 7.5/5.0 HP Pump (Primary and secondary). Make : SKF/ NBC/TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per pump design. Both the bearings (as per pump Make) to be replaced at the same time.

6

-

-

... More
S&F in replacement of cooling fan motot suitable for Centrifugal/Monoblock Motor of capacity 100 HP

2

-

-

... More
S&F in replacement of cooling fan motot suitable for Centrifugal/Monoblock Motor of capacity 60 to 75 HP

4

-

-

... More
S&F in replacement of cooling fan motot suitable for Centrifugal/Monoblock Motor of capacity 30 to 40 HP

4

-

-

... More
S&F in replacement of cooling fan motot suitable for Centrifugal/Monoblock Motor of capacity 12.5 to 20 HP

6

-

-

... More
S&F in replacement of cooling fan motot suitable for Centrifugal/Monoblock Motor of capacity 5 to 10 HP

6

-

-

... More
S&F in replacement of Centrifugal/Monoblock Pump motor MS coupling suitable for 100 HP motor (Beam, Jaw, Gear any type)

2

-

-

... More
S&F in replacement ofCentrifugal/Monoblock Pump motor MS coupling suitable for 75/60 HP motor (Beam, Jaw, Gear any type)

2

-

-

... More
S&F in replacement ofCentrifugal/Monoblock Pump motor MS coupling suitable for 30 HP to 40 HP motor (Beam, Jaw, Gear any type)

3

-

-

... More
S&F in replacement of Centrifugal/Monoblock Pump motor MS coupling suitable for 20 HP motor (Beam, Jaw, Gear any type)

4

-

-

... More
S&F in replacement of Induction Motor prelubricated ZZ bearing (DE and NDE) for 100 HP (Primary and secondary). Make : SKF/NBC/ TATA/FAG/ UBC. Note: The quoted rates include cost of two Nos bearing as per motor design. Both the bearings (as per motor frame type) to be replaced at the same time.

2

-

-

... More
S&F in replacement of Induction Motor prelubricated ZZ bearing (DE and NDE) for 75/60 HP (Primary and secondary). Make : SKF/NBC/ TATA/FAG/ UBC. Note: The quoted rates include cost of two nos bearing as per motor design. Both the bearings (as per motor frame type) to be replaced at the same time.

5

-

-

... More
S&F in replacement of Induction Motor prelubricated ZZ bearing (DE and NDE) for 40/30 HP (Primary and secondary). Make : SKF/NBC/ TATA/FAG/ UBC. Note: The quoted rates include cost of two nos bearing as per motor design. Both the bearings (as per motor frame type) to be replaced at the same time.

6

-

-

... More
S&F in replacement of Induction Motor prelubricated bearing (DE and NDE) for monoblock 20 HP. Make : SKF/NBC/ TATA/FAG/ UBC.

6

-

-

... More
S&F in replacement ofInduction Motor prelubricated bearing (DE and NDE) for monoblock 15/12.5 HP. Make : SKF/NBC/ TATA/FAG/ UBC.

6

-

-

... More
S&F in replacement of Induction Motor prelubricated bearing (DE and NDE) for monoblock 7.5/5.0 HP. Make : SKF/NBC/ TATA/FAG/ UBC.

7

-

-

... More
Dismantling, opening and reassembling of CI impellar and transportation to workshop and back after repair and refixing the same position at site and testing of CI impellar for centrifugal /Monoblock 60 to 100 HP pump set complete all as specified and directed.

4

-

-

... More
Dismantling, opening and reassembling of CI impellar and transportation to workshop and back after repair and refixing the same position at site and testing of CI impellar for centrifugal /Monoblock 40 HP pump set complete all as specified and directed.

2

-

-

... More
S&F in replacement of CI impellar for centrifugal /Monoblock 20 HP pump set including taking out existing old unserviceable complete all as specified and directed.

2

-

-

... More
S&F in replacement of CI impellar for centrifugal /Monoblock 15/12.5 HP pump set including taking out existing old unserviceable complete all as specified and directed.

2

-

-

... More
S&F in replacement of CI impellar for centrifugal /Monoblock 7.5 HP pump set including taking out existing old unserviceable complete all as specified and directed.

2

-

-

... More
S&F in replacement of CI impellar for centrifugal /Monoblock 5 HP pump set including taking out existing old unserviceable complete all as specified and directed.

4

-

-

... More
S&F in replacement of Power Contactor for following capacity, Motor Starter (Amp rating as per site requirement) including removing of exiting burnt and unserviceable Power contactor and cleaning of carbon fixed as in repair complete all as specified and directed. (a) Power Contactor for 20 HP Motor Starter. Make: Havells/L&T/C&S

6

-

-

... More
(b) -Ditto- all item as per 66.00 above but Power Contactor for 40 HP Motor Starter. Make: Havells/L&T/C&S

4

-

-

... More
(c) -Ditto- all item as per 66.00 above but Power Contactor for 60 HP Motor Starter. Make: Havells/L&T/C&S

3

-

-

... More
(d) -Ditto- all item as per 66.00 above but Power Contactor for 75 HP Motor Starter. Make: Havells/L&T/C&S

2

-

-

... More
(e) -Ditto- all item as per 66.00 above but Power Contactor for 100 HP Motor Starter. Make: Havells/L&T/C&S

2

-

-

... More
S&F in replacement of Motor starter overload relay for following capacity, Motor Starter (Amp rating as per site) including removing of exiting burnt/US relay fixed as in repair complete all as specified and directed. (a) Motor starter overload relay for capacity 100 HP Motor Starter. Make: Havells/L&T/C&S

2

-

-

... More
(b) -Ditto- all item as per 67.00 above but Motor starter overload relay for capacity 75/60 HP Motor Starter. Make: Havells/L&T/BCH

3

-

-

... More
(c) -Ditto- all item as per 67.00 above but Motor starter overload relay for capacity 40 HP Motor Starter. Make: Havells/L&T/BCH

3

-

-

... More
(d) -Ditto- all item as per 67.00 above but Motor starter overload relay for capacity 20 HP Motor Starter. Make: Havells/L&T/BCH

3

-

-

... More
Supply and fixing in repair/replacement of following parts for existing submerisble pump set 15 HP to 30 HP, electric driven, Three phase, 415 volt complete all as specified and directed. (a) Thrust Bearing of suitable size motor as per site requirement.

4

-

-

... More
(b) -Ditto- all item as per 68.00 above but Thrust plate with key of suitable size motor as per site requirement.

4

-

-

... More
(c) -Ditto- all item as per 68.00 above but Thrust Bearing housing/bearing bush of suitable size motor as per site requirement.

4

-

-

... More
(d) -Ditto- all item as per 68.00 above but Rotor Sleeve SS (Upper and Lower)/Sand Gaurd of SS of suitable size motor set as per site requirement

6

-

-

... More
(e) -Ditto- all item as per 68.00 above but Motor Pump coupling SS including Key for suitable size motor as per site requirement

4

-

-

... More
(f) -Ditto- all item as per 68.00 above but Brass impeller for 8 stage pump upto 5 HP to 15 HP

4

-

-

... More
(g) -Ditto- all item as per 68.00 above but Brass impeller for 8 stage pump above 15 upto 30 HP

4

-

-

... More
(h) -Ditto- all item as per 68.00 above but Body bush for capacity 15 HP to 30 HP pump set

6

-

-

... More
S&F in replacement of Fully automatic star delta starter for submersible pump, in sheet steel enclosure, suitable for following capacity, 3 Phase, 50 Hz, 415 Volt, AC supply suitable for following capacity pump set compressing of Ammeter, Volt meter, selector switch and indicator lamp, single phase preventer, Auto/Manual Mode, Under current, over current, phase reversal, phase unbalance, locked rotor and ground fault and testing and including dismantling & taking out old unserviceable star delta starter complete all as specified and directed. (a) For 12.5 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.

2

-

-

... More
(b) -Ditto- all item as per 69.00 above but for 20 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.

3

-

-

... More
(c) -Ditto- all item as per 69.00 above but for 25 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.

3

-

-

... More
(d) -Ditto- all item as per 69.00 above but for 30 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.

1

-

-

... More
(e) -Ditto- all item as per 69.00 above but for 40 HP motor. Make : BCH/C&S/Havells/Legrand/L&T.

1

-

-

... More
S&F in replacement of DOL starter with wide band coil, Phase reversal preventation, Phase imbalance preventation, single phase protection, Auto/Manual mode of following capacity including dismantling & taking out old unserviceable DOL starter including dismantling & taking out old unserviceable starter complete all as specified and directed. Make : BCH/C&S/Havells /Legrand/L&T. (a) For upto 5 HP motor

4

-

-

... More
(b) -Ditto- all item as per 70.00 above but For above 5 HP to 15 HP motor

4

-

-

... More
M&L for Oiling and greasing of pump motor parts (any make any size any type) by means of greasing gun or manually by unbolting and separating the pump motor set at pump house inside defence area complete for smooth operation of machinery including replacement of nut, bolts, washers of appropriate size as per site requirement and motor pump size complete making it leakage free and applying gland packing of necessary quantity and thickness and making working complete noise and leakage free and refixing in same original position complete all as specified and directed. Note: Rates for greese, lubricating oil and gland packing deemed to be included in quoted rates by the tenderer. Also, measurment of these items will be saperate and not to be included in any other item above

25

-

-

... More
S&F in replacement of Electronic type Single Phase Preventor suitable for 3 Phase, 415 Volt, motor VSP-3 of any make and any size complete as per sample including disconnecting & taking down old unserviceable Single Phase Preventor, complete all as specified and directed. Make : C&S/Havells/ABB/L&T

25

-

-

... More
S&F in replacement of Cable of size 10 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.

200

-

-

... More
S&F in replacement of Cable of size 16 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.

200

-

-

... More
S&F in replacement of cable of size 35 sqmm multistranded copper conductor, 3 core PVC insulated and sheathed copper screen protected 1100 Volts grade submersible flat cable fixed to column pipes/panel to motor with suitable clamps & jointing material complete including disconnecting & taking out old unserviceable cable complete all as specified and directed.

90

-

-

... More
M&L for cable jointing kit for 11000 Volts grade HT cable for straight through heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm 3 core to 95 sqmm 3 core and including dismantling & taking out old unserviceable jointing kit complete all as specified & directed

1

-

-

... More
M&L for cable jointing kit for 11000 Volts grade HT cable for out door termination end heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm 3 core to 95 sqmm 3 core and including dismantling & taking out old unserviceable jointing kit complete all as specified & directed

2

-

-

... More
M&L for cable jointing kit for 11000 Volts grade HT cable for indoor termination end heat shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm 3 core to 95 sqmm 3 core and including dismantling & taking out old unserviceable jointing kit complete all as specified & directed

2

-

-

... More
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cm x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/ panel/ equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15mm bore 7.50 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers, PCC chamber (1:3:6) type C1, 23 mm thick sand stone slab pit cover complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing. Note : PCC chamber shall be constructed at least 1.5 mtr away from the earth electrode and pipe for watering shall be provided in slanting manner.

4

-

-

... More
M&L for Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 25mmx4mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No 03 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:3:6) type C-2, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe light grade 20mm bore for watering and 40mm bore GI pipe medium grade for earth wire protection fixed with poles with two clamps, made from MS flat 25mm x 3mm, bolts, nuts and washers 75mm thick RCC cover 1:2:4 type B-1 shall be provided on CI frame etc including dismantling & taking out old existing unserviceable earthing complete all as specified. Note:- PCC chamber shall be constructed at least 1.5m away from the earth electrode. The pipe for watering shall be provided in slanting manner.

4

-

-

... More
Supply and pouring (Calcium hypo chloride) 65%-70% chlorine including anti corrosive agent content Liquid desinfectant for Sewage treatment plants much more stable than chlorine gas & stronger than bleaching powder and sodium hypo chloride packed in 50 Kg drum complete as directed by Engineer-in-Charge. Make : Vasu, Corrocil-D-2000 or equivalent of Auafit/ Altoch(declibec) or Equivalent. Note: Test Certificate from government certified lab for each batch of chlorine to be submited at the time of delivery.

600

-

-

... More
Maintenance and servicing of DG Set capacity 63 KVA complete including draining out of Diesel from tank, cleaning the tank thouroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner. change air cleaner elements, check collant level & make up the same, drain the Fuel Filter & water separator, filling the starting batteries with electrolyte/ distilled dwater to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-Belts, changes rubber hoses and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc, adjust/ set the same for proper functioning of DG Set, checking of fuel, oil and water/ Coolant level etc,adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the manufacturer and test for satisfactory running of DG Set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc complete all as specified and directed.

2

-

-

... More
Maintenance & servicing of DG Set capacity 100 KVA to 160 KVA complete including draining out of Diesel from Tank, cleaning the tank thouroughly and refilling the drained out diesel, draining out engine oil from the chamber, cleaning the chamber thoroughly and refilling the same with new engine oil to required level, replacing the fuel filter, lubricating oil filter, check & clean Air cleaner. change air cleaner elements, check collant level & make up the same, drain the Fuel Filter & water separator, filling the starting batteries with electrolyte/ distilled water to maintain the required specific gravity, replace the unserviceable brass connectors for batteries, cleaning of battery terminals & applying petroleum jelly to battery terminal posts & brass connectors, changing of V-Belts, changes rubber hoses and clips of air cleaner, checking of exhaust leakage & repairing the same, Governor, breathers etc, adjust/ set the same for proper functioning of DG Set, checking of fuel, oil and water/ Coolant level etc, adjusting and keeping the fan belts to the desired tension, tightening all the bolts and nuts to the required torque etc, cleaning the DG set with accessories as prescribed by the manufacturer and test for satisfactory running of DG Set for two hour at connected load & record shall be made in respect of RPM, oil pressure, oil temperature, coolant temperature, voltage, frequency, load current, battery charging, fuel consumption etc complete all as specified and directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.