Military Engineer Services Tender
... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Electrical and Electronics
Eprocure
Opening Date21 Jan 2025
Closing Date18 Feb 2025
Tender Amount₹ 46,82,000
Costs
EMD
₹ 93,660Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_694225_1Bid Award Id
ViewTender No
GE SGNR/TOK-75 OF 2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per Srl item No -02 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed.
25
-
-
... More
All as per Srl item No. 2 here in before but for one switch socket combinationt 6 pin 5/ 15 Amps on independent board with copper conductor 2.5 Sqmm complete all as specified and directed.
40
-
-
... More
All as Srl item No. 02 here in before but for one light point controlled by two 2 ways switches complete all as specified and directed.
20
-
-
... More
All as per Srl item No. 2 here in before but for call bell point complete all as specified and directed.
20
-
-
... More
M & L for concealed existing conduit point wiring complete for light/ fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in PVC existing concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, modular juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for modular sunken cast iron/ pressed steel terminal boxes thickness & deep as per recommended by OEM including modular cover plate and frame for mounting, switches, sockets,fan regulator and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor 1.5 sqmm FRLSH copper PVC insulated cable and connected to common earth dolly for one light/ fan point controlled by one switch,complete all as specified and directed.
600
-
-
... More
All as per Srl item no -08 here in before but for one switch socket combination 5/6 Amps on independent board complete all as specified and directed.
60
-
-
... More
All as per Srl item No -08 here in before but for one three pin socket outlet 5 Amp on same board with other switches complete all as specified and directed.
50
-
-
... More
All as per Srl item No. 8 here in before but for one socket outlet 3 pin 15 Amps on independent board with 2.5 Sqmm copper cable complete all as specified and directed.
80
-
-
... More
All as per Srl item No. 8 here in before but for one light point controlled by two 2 ways switches complete all as specified and directed.
20
-
-
... More
All as per Srl item No. 8 here in before but for call bell point complete all as specified and directed.
25
-
-
... More
M & L modular switch 5/6 Amps single pole one way,one module complete all as specified and directed.
910
-
-
... More
M & L of module switch 1 way 16 A, 1 module complete all as specified & directed.
120
-
-
... More
M & L modular switch 5/6 Amps single pole two ways complete all as specified and directed.
80
-
-
... More
M & L of modular socket, 6/16 Amps, 2/3 pin combined 2 module complete all as specified and directed.
120
-
-
... More
M & L modular socket outlet 5 pin 5 Amps flush type complete all as specified and directed.
110
-
-
... More
M & L modular bell push 5 Amp complete all as specified and directed.
20
-
-
... More
Taking down old unsv industrial metal clad plug socket and replace with new industrial socket metal clad plug and socket with MCBs single pole 20 Amp complete all as specified and directed.
30
-
-
... More
Taking down old unsv fan regulator and replace with new modular type fan regulator not less than 120 watt for ceiling fan 1200/1400mm sweep complete all as specified and directed.
80
-
-
... More
Taking down old unsv T/L fitting, bulkhead, angle holder etc of any type and capacity and deposite to MES store yard complete all as specified and directed.
520
-
-
... More
Fixing only new angle holder issued from MES store yard against items obtained from dismantling complete all as specified and directed.
80
-
-
... More
Fixing only new security light fitting any watt, any type with all necessary wiring from ceiling rose to existing light fitting issued from MES store yard against items obtained from dismantling with all necessary acessories complete all as specified and directed.
50
-
-
... More
Fixing only light fitting with new LED batten 20 watt with all necessary wiring from ceiling rose to existing light fitting issued from MES store yard against items obtained from dismantling with all other accessories ceiling rose/connector complete all as specified and directed.
200
-
-
... More
Fixing only new bulk head fitting 10 watt issued from MES store yard against items obtained from dismantling, complete all as specified and directed.
60
-
-
... More
Fixing only new mirror light fitting 10 watt issued from MES store yard against items obtained from dismantling complete all as specified and directed.
60
-
-
... More
Fixing only new 2' x 2' light fitting 36 watt issued from MES store yard against items obtained from dismantling complete all as specified and directed.
50
-
-
... More
Taking down old unsv highbay light fitting and replace with new LED highbay luminaire 80W having fin ventilation technology for better thermal management and its cutting edge LED technology seeks to various industrial applicaton Luminaire has an efficacy of 110 Lm/w,Ingress protection of IP66 complete all as specified and directed.
20
-
-
... More
Taking down old unsv Decorative wall light and replace with new Decorative wall light fixture made up of Polycarbonate, suitable for 9 W LED lamp B22 base complete all as specified and directed.
30
-
-
... More
Taking down old unsv LED focussed light and replace with new track mounted LED focussed light 10 watt 3000k with modern design, compact size with High power complete all as specified and directed.
25
-
-
... More
Taking down old unsv Round recess mounted LED and replace with new Round recess mounted LED edge lit slim downlight 12 Watt with die-cast aluminum housing finished in premium white powder coating. Efficacy 100lm/w complete all as specified and directed.
25
-
-
... More
Taking down old unsv suspension light and replace with new LED suspension light fitting 36 W, aluminum extruded direct-indirect light effect gives homogenous light distribution effect & enhances the visual comfort with joining kit accessories and connecting to mains cable complete all as specified and directed.
20
-
-
... More
S & F sensor based recess mounting LED light fitting 2' x 2' 36 W luminaire architecture recessed luminaire with CRCA housing and molded PC diffuser with an unique angular optics for making the illumination easy on eyes on eyes for light comfort in office areas with UGR=19. The luminaire should have a colour consistency SDCM5, CRI80 and choice of CCT:5700K complete all as specified and directed.
150
-
-
... More
S & F sensor based LED batten 20 watt having extruded aluminium housing with microwave motion technology for providing an energy efficient soluion with aluminium housing and integrated electronic driver complete all as specified and directed.
150
-
-
... More
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 6 sqmm (Nominal Area) FRLS stranded copper conductor drawn in existing PVC conduict including 6.00 Sq mm (Nominal Area) copper cable as earth continuity conductor including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed.. (Note : PVC cable and PVC conduit shall be ISI marked)
600
-
-
... More
S & F in replacement of sub-main wiring with PVC insulated and un-sheathed 4 x 6.00 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including PVC "medium quality" conduit as per size required including 2 x 6 Sqmm (Nominal area) copper cable as earth contiunity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed..
(Note : PVC cable and PVC conduit shall be ISI marked) Note :- 4 lengths of 6 Sqmm cable and one length of 2x6 Sqmm earth cable along with PVC conduit will be measured as one running length
300
-
-
... More
S & F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheathed 4 sqmm (Nominal Area) FRLSH stranded copper conductor drawn in and including steel dia 25mm “medium quality” conduit including 4.00 Sq mm (Nominal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existing colour , necessary junction box and covers including necessary connections, PVC flexible pipes are used in pannel board while connecting the cable complete all as specified and directed.
300
-
-
... More
Taking down old unsv DB and replace with new sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 8 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
40
-
-
... More
Taking down old unsv DB and replace with new sheet metal enclosure for double door DB made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed.
20
-
-
... More
Taking down old unsv DB and replace with new sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surface with insulated material like polyester with epoxy powder coated surface mounted VTP & N 4 ways, 415 Volts, ISI marked 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCCB and isolators etc including fixing in Wall with Cement mortar complete all as specified and directed.
15
-
-
... More
Taking down old unsv MCCB TPN and replace with new MCCB TPN 63 Amps with breaking capcity 25kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed.
10
-
-
... More
Taking down old unsv MCCB TPN and replace with new MCCB TP&N 40 Amps with breaking capcity 16kA ,Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed.
5
-
-
... More
Refixing only serviceable MCB ‘B’ series type and fixing only new MCB ‘B’ series type issued from MES store yard against unsv item obtained from dismantling suitable for 240 volts, AC supply 5 to 30 Amps , single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
440
-
-
... More
Refixing only serviceable MCB ‘c’ series type and fixing only with new MCB ‘C’ series type issued from MES store yard against unsv item obtained from dismantling, suitable for 240 volts, AC supply 5 to 30 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
40
-
-
... More
Refixing only serviceable MCB ‘c’ series type and fixing only with new MCB ‘C’ series type issued from MES store yard against unsv item obtained from dismantling suitable for 240 volts, AC supply 40 to 63 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed.
20
-
-
... More
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate no.3 of SSR part 1 and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on complete all as specified and directed. Note: Destruction of old earthing pit and connected items retrived from site will deposite in MES store yard.
30
-
-
... More
Removing of old paint complete with emery paper and cleaning with scrapper and preparation of internal surfaces & bottom of the desert coolers and applying two coat of spray painting with synthetic enamel paint to external surfaces of desert coolers including steel grills, side panel etc complete all as specified and directed.
100
-
-
... More
S&F in replacement water pumps heavy duty of capacity 18 to 25 watt , 230 volts 50 HZ single with copper winding complete all as specified and directed.
250
-
-
... More
S&F in replacement fan motor kit copper wound 1/6 to 1/8 HP 230 volts 50 HZ including mounting legs complete all as specified and directed.
100
-
-
... More
Taking down carefully fan motor 1/6 to 1/8 HP 230 volts, 50 HZ, existing desert coolers and refixing the same fan motor after rewinding with super enameled copper wire of existing size complete including replacement of mounting legs complete all as specified and directed.
120
-
-
... More
S&F in replacement of MS shaft for desert cooler motor as per existing size including two numbers gun metal bush complete all as specified and directed.
100
-
-
... More
S&F in replacement copper conductor size cable of size 3 core 1.5 sqmm, suitatable for water cooler complete all as specified and directed.
120
-
-
... More
S&F in replacement iron front grill including nuts bolts and washers suitable minimum size 18/20” or 21/23 '' of existing desert coolers with switches for cooler motor and water pump alongwith regulator complete all as specified and directed.
60
-
-
... More
S&F in replacement 20 gauge GI plain sheet class -III including cost of riveting welding, nuts and bolts as required for fixing etc complete all as specified and as directed. Bottom tank comlpete as per existing size.
70
-
-
... More
S&F in replacement Top cover of minimum size 20''x20 '' of desert cooler complete all as specified and directed.
80
-
-
... More
S&F in replacement Side panels of minimum size 26''x28'' of desert cooler complete all as specified and directed.
80
-
-
... More
S&F in replacement Wood wool pad of minimum size 22'x26' for desert coolers (set of three) complete all as specified and directed.
601
-
-
... More
S&F in replacement Supporting Jali for desert coolers (set of three) complete all as specified and directed.
200
-
-
... More
S&F in replacement Plug Top 3 pin, 5-A, 230 Volt complete all as specified and directed.
80
-
-
... More
S&F in replacement Plug Top 3 pin, 15-A, 230 Volt complete all as specified and directed.
100
-
-
... More
S&F in replacement Fan blades made out of aluminium for desert cooler as per sample complete all as specified and directed.
100
-
-
... More
S&F in replacement MS Angles for desert cooler stands size 32X6 mm cross section along with necessary fabrication and fixing works using suitable fasteners etc complete all as specified and directed.
2
-
-
... More
S&F in replacement elbow,distributor of PVC for Desert cooler with fixing bolt complete all as specified and directed.
112
-
-
... More
S&F in replacement tap mounting nipple 15mm,water outlet nipple with washer and checknut, float valve and PVC flexible pipe minium 2.5 meter length suitable for desert cooler (As per sample) 15 mm dia complete all as specified and directed.
80
-
-
... More
Disconnecting, dismantling and taking out existing burnt out compressor from the water cooler, supply & fixing of new Hermetic sealed unit compressor along with OLP & starting relay suitable for water cooler of cooling capacity 150 Litres per hour including necessary gas charging complete all as specified and directed.
4
-
-
... More
All as per item No. 66 here-in-before but suitable for water coolers of cooling capacity 40/60 Ltrs/Hr complete all as specified and directed.
6
-
-
... More
Supply and fixing in replacement of fan motor, Capacitor starter with blade, single phase, AC, 50 HZ suitable for water cooler of cooling capacity 40/60/150 litre per hour including fittings on existing MS plate form and making connection complete all as specified and directed.
10
-
-
... More
Rewinding of fan motor with super enameled copper winding wire of adequate size and gauge as per existing winding including insulating material, varnish drying, baking etc for water cooler of capacity 40 litre to 150 litre per hour complete all as specified and directed.
10
-
-
... More
Supply and fixing in replacement push cock CP brass 15 mm dia bore suitable for water cooler complete all as specified and directed.
20
-
-
... More
M & L for cleaning/ flushing the unit with N2 gas and supplying and recharging the refrigerant gas as recommended by OEM(R22,R404 ,R134) in water cooler capacity 40 to 150 litre per hour including replacement of strainer complete all as specified and directed.
40
-
-
... More
Supply and fixing in replacement of starting relay suitable for water cooler of capacity 40/80/150 litre per hour complete all as specified and directed.
10
-
-
... More
Supply and fixing replacement of copper tubing size 3/5 mm dia for suction & discharge lines in water cooler complete all as specified and directed.
20
-
-
... More
Supply and fixing in replacement of running capacitor 10/20/25 MFD oil filled suitable for water cooler of capacity 40/80/150 litre per hour complete all as specified and directed.
18
-
-
... More
Supply and fixing in replacement of starting capacitor 40/60/80/100 MFD oil filled suitable for water cooler of capacity 40 to 150 litre per hour and making necessary electric connection complete all as specified and directed.
28
-
-
... More
Supply and replacement of thermostat switch complete with plate and screw suitable for water cooler of cooling capacity 150/60/40 litre per hours and making necessary electric connection complete all as specified and directed.
20
-
-
... More
Supply and fixing in replacement of copper wiring for water cooler of capacity 40/60/150 litre per hour and making necessary electric connection complete all as specified and directed.
8
-
-
... More
M&L Spray painting to water cooler of capacity 40 to 150 Litre per hour and Refg of capacity 165 to 310 litre with one coat of synthetic enamel paint including preparing the existing painted surface. Colour shall be as per existing shade complete all as specified and directed.
18
-
-
... More
Supply and fixing in replacement PVC drain pipe 25/32 mm bore heavy duty including clamp for water cooler complete all as specified and directed.
20
-
-
... More
Welding and patch repair of bottom and side panel of water coolers/Refg including replacement of bottom MS Sheet of 16 gauge for mounting compressors and blower motors complete all as specified and directed.
7
-
-
... More
Disconnecting , dismantling and taking out existing burnt out compressor from the machine, supply & fixing Hermetic sealed unit compressor along with OLP & starting relay as per existing model & make suitable for Refrigerator of capacity 165 to 320 Ltrs suitable for operation on 280 volt AC supply including necessary gas charging complete all as specified and directed.
9
-
-
... More
M&L for Cleaning / Flushing the gas system with N2 gas and supplying and recharging the refrigerator gas(R 600,R134,R404) of capacity 165 to 310 litre & deep freezer with refrigerant gas including replacement of strainer and compressor oil and rectification of leakage in the entire system complete all as specified and directed.
30
-
-
... More
Supply and fixing in replacement of over load protector relay ,thermostate switch with knob ,plate and scews for automatic defrosting device suitable for 310 / 286 / 165 litre capacity refrigerator & 300/320 ltr deep freezer complete all as specified and directed.
20
-
-
... More
Supply and fixing in replacement of thermostat switch with knob, plate and screws for automatic defrosting device suitable for 310/286/165 litre capacity refrigerator & deep freezer 320/300 ltrs complete all as specified and directed.
9
-
-
... More
Supply and fixing in replacement of door gasket suitable for deepfreezer 300/320 ltr & 310/286/165 litre capacity refrigerator complete all as specified and directed.
17
-
-
... More
Supply and fixing in replacement of freezer including necessary capillary suitable for 165 to 325 litr capacity complete all as specified and directed.
13
-
-
... More
Supply and fixing in replacement condenser coil/Tube set suitable for 165 to 310 Ltr cap & deep freezer 165 to 320 ltrs complete all as specified and directed.
10
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements