If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 1,00,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair Maint For Imorovement Of Plants Installation Under Age Em In Aor Of Ge Af No 2 Jodhpur Repair Maint Of Old Rusted Cigi Water Pipe Line And Allied Work At Domestic And Tech Area Under Age Em Ge Af No 2 Jodhpur And Cleaning Maint Of Overhead Wa
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_684666_1Bid Award Id
ViewTender No
8493/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
All as per Srl item No 03 above but RCC overhead reservoir of capacity exceeding 25000 gallon and not exceeding 0.5 Lakh gallon capacity at 60 feet
2
-
-
... More
All as per Srl item No 03 above but RCC overhead reservoir of capacity exceeding 50000 gallon and not exceeding 1.5 Lakh gallon capacity at 60 feet
3
-
-
... More
M&L for Cleaning of RCC underground sump upto 20000 Lakh gallon capacity at 20 feet depth by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge with and including writing capacity of tank , date of cleaning of tank with synthetic enamel paint on outer surface of the tank complete all as specified and as directed by Engineer-in-Charge.
10
-
-
... More
All as per Srl item No 06 above but RCC underground sump of capacity exceeding 0.5 lakh gallon and not exceeding 1 Lakh gallon capacity at 20 feet depth
2
-
-
... More
All as per Srl item No 06 above but RCC underground sump of capacity exceeding 1 lakh gallon and not exceeding 2.5 Lakh gallon capacity at 20 feet depth
5
-
-
... More
M&L for Cleaning of clarifloculator of Cap 100000 Glns by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and Greasing all components by replacing the worn nut bolts of non clogging pump motor, and removing all the sludge dirt and deposits of any foreign materials etc. , painting of all the steel member channels, angles of the scrappers and mixers with two coats of bituminous based paint after preparation of old painted surface all as specified and directed by Engr-in-Charge.
1
-
-
... More
M&L Cleaning of RCC raw water (back wash) sumps cap 25000 gln by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge
3
-
-
... More
M&L Cleaning of RCC sedimentation sumps cap 50000 gln by drain out the contaminated muddy water from bottom surfaces of the tank by using of pump and motor or by manually and cleaning the inside & bottom surfaces of walls with help of wire brushes and using specified dosage of potassium permanganate and cleaned water then drain out completely material to the entire satisfaction of Engineer-in-Charge
1
-
-
... More
Supply only Water treatment Calcium hypo Chloride 65%-70% chlorine content (calcium based granular disinfectant for water treatment, packed in 45 kg drum complete.
900
-
-
... More
Supply only Water treatmentbleaching Powder 25 Kg bag complete all as specified and as directed.
500
-
-
... More
Excavation in trenches, not exc 1.5 m wide and n. exc 1.5 m depth, or n exc 10 Sqm on plan and n exc 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, pier holes, for foundations of poles, struts, stays etc. or laying underground cable and water supply pipe lines etc. in hard/dense soil/rocks, & getting out including taking out old brick or precast cable cover complete all as specified and directed by Engineer-in-Charge.
450
-
-
... More
Returning, filling in, including spreading, leveling watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed by Engineer-in-charge.
443.6
-
-
... More
Removal of excavated soil material to a distance not exc 50 metre and depositing where directed at a level not exc 1.50 metre above the starting point complete all as specified and directed by Engineer-in-charge.
38.4
-
-
... More
Taking up or down 15mm bore galvanised steel water tubing including connections, fixed in walls, ceiling or laid under floor or laid in trenches etc complete all as specified and directed by Engineer-in-charge.
Note :-Excavation and earthwork shall be measured and paid for separately.
200
-
-
... More
All as per Srl item No 17.00 above but 20 mm dia bore.
1000
-
-
... More
All as per Srl item No 17.00 above but 25 mm dia bore.
200
-
-
... More
All as per Srl item No 17.00 above but 40 mm dia bore.
250
-
-
... More
All as per Srl item No 17.00 above but 50 mm dia bore.
400
-
-
... More
All as per Srl item No 17.00 above but 80 mm dia bore.
300
-
-
... More
All as per Srl item No 17.00 above but 100 mm dia bore.
100
-
-
... More
All as per Srl item No 17.00 above but 150 mm dia bore.
100
-
-
... More
S&F 15mm bore galvanized steel water tubing medium grade with & including all fittings and fixed complete to walls and ceilings or laid in floors / trenches complete all as specified and directed by Engineer-in-charge.
200
-
-
... More
All as per Srl item No 25.00 above but 20 mm dia bore.
1000
-
-
... More
All as per Srl item No 25.00 above but 25 mm dia bore.
200
-
-
... More
All as per Srl item No 25.00 above but 40 mm dia bore.
250
-
-
... More
S&F 50mm bore galvanized steel water tubing medium grade with & including all fittings, laid in trenches complete all as specified and directed by Engineer-in-charge.
400
-
-
... More
All as per Srl item No 29.00 above but 80 mm dia bore.
300
-
-
... More
Supplying, laying, jointing, commissioning and testing 100mm bore centrifugally cast (Spun) ductile iron pressure pipe with spigot and socketed ends class K-7, confirming to IS : 8329/2000 blast furnace slag cement with portland cement properties suitable for rubber gasket jointing / tyton joints with inside cement mortar lining and black bitumen external coating, duly (ISI marked) laid in trenches complete all as specified and directed by Engineer-in-Charge. Note :- (i) DI fittings shall be measured and paid separately under respective items (ii) Pipes shall be laid in trenches already excavated for taking out old GI pipe line. Extra excavation / earthwork shall not be paid.
100
-
-
... More
All as per Srl item No 31.00 above but 150 mm dia bore.
100
-
-
... More
S&F in replacement gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes complete all as specified and directed by Engineer-in-charge.
50
-
-
... More
All as per Srl item No 33.00 above but 25 mm dia bore.
10
-
-
... More
All as per Srl item No 33.00 above but 40 mm dia bore.
20
-
-
... More
All as per Srl item No 33.00 above but 50 mm dia bore.
10
-
-
... More
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 80 mm bore, ISI marked with IS 14846 : 2000, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable sluice valve of 80 mm bore, complete, all as specified & directed.
4
-
-
... More
All as per Srl item No 37.00 above but 100 mm dia bore.
4
-
-
... More
All as per Srl item No 37.00 above but 150 mm dia bore.
4
-
-
... More
All as per item No. 37.00 here-in-before but size of 200mm
1
-
-
... More
All as per item No. 37.00 here-in-before but size of 250mm
1
-
-
... More
S&F Cast iron non return valve / reflux valve with rubber seat flanged type with by pass arrangement suitable for 80mm bore pipe, ISI marked, conforming to IS- 5312/2004 with stainless steel spindle, CI gate with brass nuts, bolts, washers and jointing with necessary ruber gasket etc including dismantling & taking out old unserviceable sluice valve of 80 mm bore, complete, all as specified & directed.
2
-
-
... More
All as per Srl item No 42.00 above but 100 mm dia bore.
2
-
-
... More
Supply and fix Foot Valve conforming to IS 4038, 80 mm (4”) dia complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
All as per Srl item No 44.00 above but 100 mm dia bore.
2
-
-
... More
All as per item No. 44.00 here-in-before but size of 150mm
2
-
-
... More
Supplying & fixing DI fittings confirming to IS-9523-2000 suitable for spigot & socketed pipes such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc),tee pieces, single branch, 'Y' junction, double branch, cross collar, caps and plugs etc. suitable for spigot and socketed pipes upto 150 mm bore, complete, all as specified and directed by Engineer-in-charge.
80
-
-
... More
M&L for Construction of brick masonry valve pit, in repair, of internal size 60cm x 60cm x 60cm including necessary excavation and earth work in soft/loose soil, brick work, plastering, white wash, PCC coping, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 3 mm thick fixed to angle iron frame by means of hinges welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock , complete all as specified and directed by Engineer - in - Charge Note :- (i) Brick wall shall be 23 cm thick built in cement mortar (1:4) (ii) Internal plaster shall be 15 mm thick in cement mortar (1:4) and external plaster upto 450mm from top shall be 20mm thick in CM (1:6) and remaining external surface shall be flush pointing in CM (1:6) as the work proceeds.
(iii) PCC in foundation shall be 15 cm thick in cement concrete (1:4:8) type D2 using 40 mm graded stone aggregate extended 15 cm all around from the external face of the walls. (iv) PCC coping shall be 15 cm thick in cement concrete ( 1:2:4) type B1 using 20 mm graded stone aggregate including grouting of angle iron frame in PCC. (v) Three coats of white wash to internal surfaces of valve pit.
(vi) Depth of valve pit shall be reckoned from the top of PCC in foundation.
4
-
-
... More
All as per Srl item No 48.00 above but internal size 90cm x 90cm x 90cm
6
-
-
... More
All as per Srl item No 48.00 above but internal size 150cm x 150cm x 90cm
2
-
-
... More
M&L for 'D' Joint suitable for DI /CI/GI pipe sizes 50 mm dia bore including excavation work and other fittings as required including testing at site complete all as specified and directed by the Engineer-in-Charge.
14
-
-
... More
All as per Srl item No 51.00 above but 80 mm dia bore.
15
-
-
... More
All as per Srl item No 51.00 above but 100 mm dia bore.
20
-
-
... More
All as per Srl item No 51.00 above but 150 mm dia bore.
20
-
-
... More
S & F in repair 15mm bore ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed all as specified and directed.
50
-
-
... More
All as per Srl item No 55.00 above but 20 mm dia bore.
400
-
-
... More
All as per Srl item No 55.00 above but 25 mm dia bore.
300
-
-
... More
BLANK
-
-
-
... More
Material and labour in repair for earthing complete with copper plate electrode 60cmx60cmx3.15mm thick, buried directly in ground, vertically to a dpeth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not lss than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead copper strip 20 x 3 mm by means of bolts, nuts, check-nuts and wahsers of galvanised iron and thimbles and of earth wire protected by galvanised iron pipe light grade 40mm bore and water pipe 20mm bore GI medium grade with funnel and wire mesh complete 1:3:6 type C-1 using 20mm graded stone aggregate in lieu of CI cover and frame etc all as specified and directed.
4
-
-
... More
S&F in replacement 80mm dia butterfly valve complete all as specified and directed by Engineer-in-charge.
1
-
-
... More
All as per Srl item No 60.00 above but 100 mm dia bore.
1
-
-
... More
All as per Srl item No 60.00 above but 150 mm dia bore.
1
-
-
... More
All as per Srl item No 60.00 above but 200 mm dia bore.
1
-
-
... More
All as per Srl item No 60.00 above but 250 mm dia bore.
1
-
-
... More
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for route of cable and getting out complete all as specified and as directed by the Engineer-in-Charge.
75.6
-
-
... More
M/&L for stone slab 40 to 50 mm thick rough dressed Jodhpur stone slab cover in trenches for protection of cable 25 to 30 cm wide and not less then 50 cm in length laid dry abutting each other with gap between adjacent slab not exceeding 10 mm over sand cushioning all as specified and directed by Engr-in-Charge.
75.6
-
-
... More
Local tibba dry sand cushioning and cover (8 cm thick layer of sand before laying of cable and 15 cm thick layer of sand after laying of cable) for protection of cable, material and labour complete all as specified and as directed by Engineer-in-Charge.
22.68
-
-
... More
S&F in replacement of PVC underground cable XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4 core.
280
-
-
... More
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc.
330
-
-
... More
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor,FRLSH, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, concealed wiring , GI terminal boxes 1.2 mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover for mounting switch and sockets etc. complete all as specified and directed for following : -
-
-
-
... More
One light point/exhaust fan point controlled by one switch or one ceiling fan point controlled by one switch & electronic type fan regulator.
220
-
-
... More
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
40
-
-
... More
One 3 pin 5 Amp switch & socket outlet on Independant board.
40
-
-
... More
All same as per item ser No 70.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board.
30
-
-
... More
S&F Switch piano, flush type, single pole, one way,5/6 Amp.
300
-
-
... More
S&F Switch piano, flush type, single pole, one way, 16 Amp.
30
-
-
... More
S&F Socket outlet 2/3 pin, 2-in-1, 5/6 Amp, flush type.
80
-
-
... More
S&F Switch Socket combination outlet 6 pin, 6/16 Amp, flush type
30
-
-
... More
S&F(in repairs) Ceiling rose surface bakelite 65x50mm three terminal.
220
-
-
... More
S&F Stepped type electronic fan regulator, switch size, flush type 230V AC.
20
-
-
... More
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
40
-
-
... More
M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
10
-
-
... More
M&L for MCB TPN/FP, 40 to 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
20
-
-
... More
S&F IN repair of MCCB 4 Pole , 415 V, Adjustable type,200 Amps with breaking capacity 36 KA .
3
-
-
... More
S&F IN repair of MCCB 4 Pole , 415 V, Adjustable type,250 Amps with breaking capacity 36 KA .
4
-
-
... More
S&F IN repair of MCCB 4 Pole , 415 V, Adjustable type,450 Amps with breaking capacity 36 KA .
4
-
-
... More
Material and Labour for preperation of old plastered surfaces of wall and applying two coats of Acrlic distemper over 1mm thick wall care putty over a coat of primer complete all as specified and directed by Engr-in-Charge
345
-
-
... More
M & L for three coat of white wash on old surface of ceiling including preparation of new surfaces as directed by Engineer-in-Charge
80
-
-
... More
S & F in repair of 2000 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of ISI mark specifications as per MES Schedule 2020, Part – I and hoisted, fixed in position complete all as specified and directed.Make-Sintex/prince or equivalent ISI marked.
4
-
-
... More
S & F in repair of 5000 Litre capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) of ISI mark specifications as per MES Schedule 2020, Part – I and hoisted, fixed in position complete all as specified and directed.Make-Sintex/prince or equivalent ISI marked.
4
-
-
... More
M&L mm thick PCC (1:2:4) type b2 (using 40mm graded stone aggregate) as finished surface even and fair without using extra cement all as specified and complete all as specified and directed.
63
-
-
... More
Supply and replace sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
6
-
-
... More
Supply and fixing in repair of LED lights fitting 1x 20W, 220V,AC aluminium body decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.make-philips,havells ,crompton or equivalent model approved makes.
250
-
-
... More
S&F in repair Building security light fittings, with pressure die cast aluminium housing, suitable for 35 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL35W or equivalent model approved makes.
57
-
-
... More
S&F in repair Building security light fittings, with pressure die cast aluminium housing, suitable for 60 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL60W or equivalent model approved makes.
40
-
-
... More
NOTES FOR LED LIGHT FITTINGS & BULBS :
(i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13.
(ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80.
(iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :-
(a) Manufacturing defects.
(b) Failure due to mechanical and electrical impact.
(c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
-
-
-
... More
M&L for Sub main wiring as per IS, single core FRLS PVC insulated flexible multistranded copper conductor,FRLSH, 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green color. (for SMQ)
150
-
-
... More
Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate) complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion.
Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
30
-
-