Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date14 Feb 2024
Closing Date13 Mar 2024
Tender Amount₹ 45,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in replacement of old unsv Energy saving Flood light 100 Watt environmental friendly, long life, exclusive innovative die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection, suitable for high lighting architectural facade high mast and general purpose lighting complete all as specified and as directed at site.

5

-

-

... More
Supply and fixing in replacement of old unsv LED Security light 90 watt made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP 66 protection efficacy more than 110LPW with 10 KV SPD incl electric connection from existing electric point complete all as specified and directed.

13

-

-

... More
Supply and fixing in replacement of old unsv LED Security light 35 watt made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP 66 protection efficacy more than 110LPW with 10 KV SPD incl electric connection from existing electric point complete all as specified and directed.

35

-

-

... More
Supply and fixing in replacement of old unsv LED Security light 60 watt made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP 66 protection efficacy more than 110LPW with 10 KV SPD incl electric connection from existing electric point complete all as specified and directed.

17

-

-

... More
Supply and fixing in replacement of old unsv LED Security light 45 watt made with pressure die cast housing with toughened glass and high power LED's with secondary optics and IP 66 protection efficacy more than 110LPW with 10 KV SPD incl electric connection from existing electric point complete all as specified and directed.

30

-

-

... More
S&F in replacement driver suitable for 35 Watts LED Security light complete all as specified and as directed.

12

-

-

... More
As per Srl Item no 9 above but for 45 watt security light

13

-

-

... More
As per Srl Item no 9 above but for 60 watt security light

12

-

-

... More
As per Srl Item no 9 above but for 90 watt security light

7

-

-

... More
Supply and fixing LED Solar street light fitting 12 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete

2

-

-

... More
Supply and fix in replacement bracket for fixing street/security light fitting made out of GI pipe medium grade 32/40 mm dia 1.0 mtr bend as reqd at site incl painting with primerand all connections to fitting with necessary MS clamps, nuts, bolts, and washers etc complete as directed.

20

-

-

... More
As per Srl Item no 14 above but for 25 mm dia

18

-

-

... More
Supply and fixing in replacement LED light 10 WATT IP65 rated Inverted Pyramid Tripod type LED Bollard with soft 360 deg light distribution with all necessary cable connection incl PCC work complete all as specified and directed.

9

-

-

... More
Supply and fix in replacement of Post top lanterns LED lights light 20 watt suitable and fixing accessories i.e nut,bolt, washer etc duly fixed on Piller with MS pipe on PCC (1:2:4 type B1) complete all as specified and directed. Note : The cost of PCC is deemed to be included in quoted rates.

10

-

-

... More
Supply and fix in replacement stand for Gate light made out of GI pipe medium grade 25/40 mm size as required length on ground complete all fitting with necessary nuts, bolts, fastner and washers etc including painting with primer complete as directed.

10

-

-

... More
Supply and fixing of GI Pipe light grade 32/40 dia mm bore upto 1.5 meter long with all necessary PCC work and earth work etc. including painting with primer for fixing of pipe at site as suitable for mounting Post top lantern/Garden light of any type and size complete all as specified and directed incl taking down old one .

26

-

-

... More
Taking down old U/S termination box by removing all electric connection complete from pole any type or size complete all as specified and directed.

19

-

-

... More
Supply and fix IP 66/67/69 Thermoplastic Polycarbonate PC -Grey Colour (RAL7035) Junction Box with multi-level knockouts as well as from rear side also for cable entires in different sizes for unprotected outdoor (UV resistance) with internally embedded gasket technology (Polyurethane). Lid fastencers shall have captive type thermoplastic screws with quarter turn knob option.The junction box shall fulfill the following standers IEC 60670-22: Particular requirments for connecting boxes and enclosures. IEC 60695-2-11: Glow Wire tested at minimun 960 deg C., Impact Resistant: IK 09 (10 joule) Halogen Free in accordance with IEC 60 754-2 Size-(205x255x112) mm Cat No KF2525G as of Hensel, L & T , C & S with 16 sqmm 5 pole Hensel Terminal with M 32 Polyamide Gland-03 Nos and all connection all as specified and directed.

10

-

-

... More
Supply and fix IP 66/67/69 Thermoplastic Polycarbonate PC -Grey Colour (RAL7035) Junction Box with multi-level knockouts as well as from rear side also for cable entires in different sizes for unprotected outdoor (UV resistance) with internally embedded gasket technology (Polyurethane). Lid fastencers shall have captive type thermoplastic screws with quarter turn knob option.The junction box shall fulfill the following standers IEC 60670-22: Particular requirments for connecting boxes and enclosures. IEC 60695-2-11: Glow Wire tested at minimun 960 deg C., Impact Resistant: IK 09 (10 joule) Halogen Free in accordance with IEC 60 754-2 Size-(205x255x112) mm Cat No KF2525G as of Hensel, L & T , C & S with 16 sqmm 3 pole Hensel Terminal with M 32 Polyamide Gland-03 Nos and all connection all as specified and directed.

9

-

-

... More
Taking out old serviceable /unserviceable LT cable of any size from excavated trenches /pipes/ wall surface complete as specified and as directed.

920

-

-

... More
Supply and laying, jointing and testing of LT XLPE insulated, PVC Sheathed, galvanized steel strip armoured electric power cable with stranded aluminium conductor, 1100 volts grade of size 25 sqmm 4.0 core confirming to IS : 7098(Part-I), suitable for earthed system, laid in duct/trench/along pole/wall etc including nuts, bolts, washers, saddles and screw etc and making connection, complete all as directed.

240

-

-

... More
As per Srl Item no 24 above but for 10 sqmm 4 core

90

-

-

... More
As per Srl Item no 24 above but for 6 sqmm 2 core

150

-

-

... More
As per Srl Item no 24 above but size 10 sqmm 2.0 core

120

-

-

... More
As per Srl Item no 24 above but for 16 sqmm 2.0 core

80

-

-

... More
All as per item no 24 but sec. area 70 sqmm 3 1/2 core.

60

-

-

... More
All as per item no 24 but sec. area 35 sqmm 3 1/2 core.

120

-

-

... More
All as per item no 24 but sec. area 50 sqmm 3 1/2 core.

60

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.5 meter depth and not exceeding 1.5 meter wide and getting out including trimming of sides, complete all as directed.

113.2

-

-

... More
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 10cm after laying of cable in trenches complete all as directed and sand cover to under ground cable complete all as directed.

30.25

-

-

... More
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm under ground cables for protection

1850

-

-

... More
M&L for galvanised steel tubing, light grade, for protection of cable, laid in trenches/road crossing/floor or fixed to pole/wall with all fittings, of size 50 mm bore.

175

-

-

... More
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick, complete all as specified

77.65

-

-

... More
Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point, complete all as specified.

34.55

-

-

... More
Taking out old unserviceable service cable of any sizes as specified and as directed by Engr-in-Charge.

220

-

-

... More
M&L for 2.5 sqmm twin core copper conductor PVC insulated PVC sheathed cable 1100 volt grde for drawing through poles or pipe for making connection to street light fitting provided on poles and upto junction box including thimble etc.

220

-

-

... More
M & L for preparation of old painted surface of electric pole by removing all dirt, dust,etc and apply one coat of synthetic emulsion paint upto 1.2 mtr hight and thereon one coat of Apex emelssion paint and one coat of synthetic enamel paint on steel surface of such as cross arms, including writing of identification Nos, etc complete all as specified and as directed for pole

36

-

-

... More
M&L steel tubular swaged poles complete with cast Iron base plate, final tapper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 Meters long ) including painting of pole with one coat of red oxide and 2 coats of aluminium paint as requivalentuired complete as per site and all as specified and directed .

15

-

-

... More
S&F in replacement of Unsv for DB Vertical Triple pole and neutral double door, flush in wall with MCCB 160 A 4 pole 415 V as INCOMER, 400 Amp bus bar rating complete all as specified and directed.

1

-

-

... More
S&F MCCB 200 Amps 4 pole 415 Volts 36 KA breaking capacity complete all as specified and directed.

1

-

-

... More
S & F MCB SP, 6 to 32 Amps in `C’ series having current rating 10 KA complete all as specified and directed.

345

-

-

... More
S & F MCB SPN 40-63 Amps in `C’ series having current rating 10 KA complete all as specified and directed.

91

-

-

... More
Supply and fixing in repair MCCB 4 Pole, 415 V, Adjustable type, 125 to 160 Amps with breaking capacity 25 KA

3

-

-

... More
Supply and fixing in repair MCB TPN/FP 32Amp , 415 Volts

4

-

-

... More
S&F MCB TPN 415 volts 63 amp 4 pole 16 KA breaking capacity, ISI marked complete all as specified and directed.

70

-

-

... More
Supply and fixing in repair MCB TPN/FP 100 Amp , 415 Volts

6

-

-

... More
S&F MCB Blanking plates suitable for MCB DB's complete all as specified and directed.

20

-

-

... More
THREE PHASE LIGHTING DISTRIBUTION BOARD -6KW 3 PHASE LBD (24 Hrs Timer) Enclosure with thermoplastic polycarbonate Size-500 x 835 x 600mm, Degree of Protection IP65 (EN 60 529), System Voltage: 415V,50HZ,4Wire+ E, Incoming-40A P 10kA MCB -1 No, 32 A TP Contactor-01 No, A/O/M selector Switch- 01 No, 24 Hr Digital timer-01 No,2A SP Control MCB -01 No, Outgoing 32 A SP 10 KA MCB -03 Nos Note:-Rate for Earth work PCC in foundation with angle iron frame of MS angle 50 X 50 X 6 mm included. Make :- Hensel , L & T , C & S

1

-

-

... More
Servicing/maintenance/repair to High Mast light along with their control gear and having two point suspension system with stainless steel wire rope as per existing size/guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightening arestor spike and clean to complete system incl minor part replacement i.e. rope/service cable, nuts&bolts, welding work, painting work, PCC work etc as reqd complete all as specified and as directed.

2

-

-

... More
Taking down unsv of aluminium strip of any size from any location with complete unsv fitting complete all as directed

400

-

-

... More
Taking down unsv, supply and fix air termination rod single pointed aluminium rod 12 mm dia, 300 mm long fixed on GI pipe and connecting to aluminium strip and fix on the roof with all fittings, fixture complete all as specifed and directed.

50

-

-

... More
Supply and fix of aluminium strip 25 X 3.15 mm in repair with saddles and fixing screws etc for roof conductors and down conductors above ground surface for lightning conductors complete all as specifed and directed.

195

-

-

... More
Supply and fix of 20x3mm copper strip in repair with saddles and fixing screws etc for roof conductors and down conductors above ground surface for lightning conductors complete all as specifed and directed.

125

-

-

... More
M & L for test point terminal block made of gun metal or phosphorous bronze size 75 X 75 X 25 mm drilled and screwed including 3 Nos. 8 mm dia 25 mm long hexagonal head screw including taking down old one complete all as directed.

30

-

-

... More
Material and labour for pipe GI tubing light grade with and incl all fitting /accessries (ISI) marked for air termination rod of size 40mm dia bore complete all as specifed including taking down old Unsv all as per directed

70

-

-

... More
Taking down unsv, supply and fix in replacement PCC 1:2:4 type B-1 using 20mm graded stone aggregate for blocks of size 300x 300x 300mm complete all as specifed and directed.

45

-

-

... More
Labour for Refix serviceable aluminium strip after straight by pulling with new saddles and fixing screws etc for as roof conductors and down conductors above ground surface for lightning conductors complete all as specifed and directed.

205

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the GI Wire of 4 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to earth point all as specified or indicated including testing on complete all as specified and as directed.

23

-

-

... More
As per Srl Item no 61 above but using galvanised iron strip 25×4mm as earthing lead.

25

-

-

... More
M&L for earthing complete with copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the copper strip means of bolts, nuts , check nuts and washers of brass and protected by provision of GI light grade pipe 40 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 2009 Part-I and connecting to earth point all as specified or indicated including testing on complete all as specified and as directed.

10

-

-

... More
Taking down unsv , Supply and fix in replacement LED aviation obstruction light fitting 12/10 watt as per existing with complete all accessories, bracket for fitting arrangement complete all as directed.

1

-

-

... More
M&L for load balancing of Three phase DB of building of any type/size and capacity complete including dis-connecting of existing cables/wires and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium /Copper Thimbles and wire connector of any size and capacity for each wire/cables all as per required on ground complete all as specified and directed . Note : (i) Necessary equipment and safety measures reqd for load balancing will be arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper thimbles, connector for wire, earth and neutral link, insulator, any type of screws, copper/aluminium bus bar of any size as per site requirement change under the job deemed to be included in the quoted rate by contractor. (iii) MCCB/MCB required for replacement shall be measured and paid separately in relevant item.

28

-

-

... More
M&L for load balancing of Single phase DB of qtr/bldg of any type/size and capacity complete including disconnecting of existing cables and refixing the same as per load balance requirement including replacement of burnt/carbonized aluminium /Copper Thimbles and wire connector of any size and capacity for each wire/cables all as per required on ground complete all as specified and directed. Note : (i) Necessary eqpt and safety measures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium / Copper thimbles, connector for wire, earth and neutral link, insulator, any type of screws, copper/aluminium bus bar of any size as per site reqmt change under the job deemed to be included in the quoted rate. (iii) MCB required for replacement shall be measured and paid separately in relevant item.

30

-

-

... More
Repair/servicing of indoor type LT panel board mounted on bldg wall of size aprox 1.2X0.90X0.25 mtrs and replacement of unserviceable switch/control gears and 2 way connector,indicator lamps, threaded panel door lock etc including rewiring and extension of incoming and out going cables by opening of loops/making joints with same size cable and provisioning of cable lugs /thimbles as reqd including replacement of rusted sheet metal with existing size MS sheets by necessary arc/gas welding / making cover as per suitable (Approx sheet 0.2 to 0.7 Sqmtrs ) and removing all dirt, dust etc with the help of air blower and load balancing of three phase panel complete & painting complete Panel board including connected accessories with two coats of synthetic enamel spray painting out side surfaces of Panel Board of approved colour including writing of identification etc all as specified and directed comprising the following :- (a) MCCB 100/125A -01 Nos (b) Indicator Lamp .-01 set (c) Coper/aluminium bus bar -01 set (d) 1 phase Energy Meter- 07 Nos (e) MCB SPN/SP - 08 Nos (f) door lock (g) Arclic PVC sheet for Energy meter -07 Nos Note : (i) Necessary eqpt and safety measures, stationary reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper thimbles, earth and neutral link, insulator, hylem sheet, any type of screws,door locks any type as per site reqmt change under the job deemed to be included in the quoted rate. (iii) MCCB, MCB,copper / aluminium bus bar, indicator lamp, PVC arclic sheet required for relacement shall be measured and paid serately in relevent item.

50

-

-

... More
Repair of indoor type LT pannel board mounted on bldg wall of size aprox 2.0X0.80X0.220 mtrs and replacement of unserviceable switch/control gears and meters,selector switches,indicator lamps, Key type panel door lock etc including replacement of any damage wiring and extension of incomming and outgoing cables by opening of loops/making joints with same size cable and provisioning of cable lugs /thimbles as reqd including removing all dirt, dust, etc all as specified and directed compriseing the following :- (a) MCCB 100 A -01 Nos. (b) Indicator Lamp -01 set (c) Aluminium bus bar -01 set (d) Single/Three phase Energy Meter- 05 to 7 Nos (e) MCB SPN/SP -05 to 7 Nos (f) Key type door lock - 8 to 12 Nos (g) Arclic PVC sheet for Energy meter -06 to 08 Nos. Note : (i) Necessary eqpt and safety measures reqd for load balancing arranged by the contractor without any extra cost. (ii) Cost of New aluminium/Copper thimbles, earth and neutral link, insulator, hylem sheet, any type of screws,door locks any type as per site reqmt change under the job deemed to be included in the quoted rate. (iii) MCCB, MCB,copper/aluminium bus bar, indicator lamp, PVC arclic sheet required for relacement shall be measured and paid serately in relevent item.

6

-

-

... More
Dismantling and taking down old Unsv existing panel board incl disconnecting of main feeder, sub feeders, bus bars, energy meters & removing from site complete all as specified and as directed..

6

-

-

... More
Supply, installation and testing of LT Panel in replacement, factory made powder coated wall mounting termoplastic polycarbonate insulated panel with IP 65 according to IEC 60 529, with protection class II , flame retardant, self extinguishing with glow wire test at 960C according to IEC 60695-2-11, Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. The panel is in accordance with IEC 61439-1&2 the OEM of board/panel shall submit a copy of type test report (ASTA certification by CPRI) of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. the CPRI report shall have mention of following tests performed and passed out satisfactorily with : temperature rise,dielectric properties, short circuit withstand current -rated peak & short time withstand current and rated conditional short circuit current , Degree of protection clearance & creepage Distance, Mechanical operation, Effectives of protective circuits, Degree of protection (a) Metering panel size 980x1254x247mm incomer-160A 4P, 25KA MCCB-01 No, outgoing- 63 A, FP , 10 KA MCB-04 Nos with provision for (10-60A) Three phase Energy Meter-04Nos Copper busbar rating 250 A Make HENSEL, L&T, Legrand

3

-

-

... More
Supply, installation and testing of LT Panel in replacement, factory made powder coated wall mounting termoplastic polycarbonate insulated panel with IP 65 according to IEC 60 529, with protection class II , flame retardant, self extinguishing with glow wire test at 960C according to IEC 60695-2-11, Impact strength IK 08 (5 Joule) in accordance with DIN EN 50102. The panel is in accordance with IEC 61439-1&2 the OEM of board/panel shall submit a copy of type test report (ASTA certification by CPRI) of a board made out of polycarbonate thermoplastic panel in accordance with IEC 60439-1. the CPRI report shall have mention of following tests performed and passed out satisfactorily with : temperature rise,dielectric properties, short circuit withstand current -rated peak & short time withstand current and rated conditional short circuit current , Degree of protection clearance & ceepage Distance, Mechanical operation, Effectives of protective circuits, Degree of protection (a) Metering panel size 680X1100X320mm incomer-125 A, 4P, 25KA MCCB-01 No, outgoing-32 A, DP ,10 KA MCB-06 Nos provision for Single phase Energy Meter-06 Nos Make HENSEL, L&T, Legrand

3

-

-

... More
Supply and fix electronic meters temper proof LCD display with polycarbonate cover single phase 230 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH.

25

-

-

... More
Supply and fix electronic meters temper proof LCD display with polycarbonate cover three phase 415 V, 10-60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH.

18

-

-

... More
M&L for checking of earth resistance test of bldg connected with panel / distribution box by disconnecting of earth strip/ wire with the help of earth resistance tester complete and maintained records in register as per sample given all as specified and as directed . Note (i) Necessary eqpt , safety measures and stationary reqd for earth resistance test arranged by the contractor without any extra cost.

80

-

-

... More
M&L in replacement LED Type indicating Lamp for indication of RYB-01 Set

40

-

-

... More
M&L in replacement Al bus bar rating 200 Amps including making hole suitable for panel with tape insulation of suitable colour in Phase RYB & neutral in Black colour complete all as specified and as directed .

15

-

-

... More
M&L in replacement aluminium bus bar rating 250 Amps including making hole suitable for panel with tape insulation of suitable colour in Phase RYB & neutral in Black colour complete all as specified and as directed.

20

-

-

... More
M&L in replacement Arclic PVC sheet minimum 4 mm thick with fixing arrangement in Panel box suitable for Meters fitted in panel complete all as specified and as directed .

5

-

-

... More
M & L for preparation of old painted surface of electric panel box at any position by removing all dirt, dust, etc and painting complete surface including connected accessories with two coat of synthetic enamel paint of approved colour including writing of identification etc complete all as specified and directed.

35

-

-

... More
Taking down old DB and Supply and fixing in repair flush in wall double door manufacturer double door MCB DB SPN 08 way comprising of sheet metal enclosure powder coated fitted with bus bar 200 Amps 240 volts complete all as specified and directed.

10

-

-

... More
Taking down old DB and Supply and fixing in repair flush in wall double door manufacturer double door MCB DB SPN 12 way comprising of sheet metal enclosure powder coated fitted with bus bar 200 Amps 240 volts complete all as specified and directed.

8

-

-

... More
Taking down old DB and Supply and fixing in repair flush in wall double door manufacturer double door MCB DB SPN 04 way comprising of sheet metal enclosure powder coated fitted with bus bar 200 Amps 240 volts complete all as specified and directed.

3

-

-

... More
Taking down old DB and Supply and fixing in repair flush in wall double door manufacturer double door MCB DB TPN 04 way comprising of sheet metal enclosure powder coated fitted with bus bar 300 Amps 415 volts complete all as specified and directed.

50

-

-

... More
S&F sheet metal enclosure SPN 240 Volts having 2 pin and earth plug and socket complete with one single pole MCB 20 Amps all as specified and directed

45

-

-

... More
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 2 single core 2.5 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, PVC FRLS board with all fittings one including 1.50 Sqmm copper conductor as earth continuity complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.

90

-

-

... More
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 2 single core 4 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, PVC FRLS board with all fittings including one 2.50 Sqmm copper conductor as earth continuity complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.

180

-

-

... More
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 2 single core 6 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, PVC FRLS board with all fittings including one 4.0 Sqmm copper conductor as earth continuity complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.

280

-

-

... More
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 2 single core 10 Sqmm copper conductor (Multistandered) in PVC FRLS conduit of suitable size as required, with all fittings including one 6.0 Sqmm copper conductor as earth continuity complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.

120

-

-

... More
Taking down old submain wiring and Supply and fixing for concealed/conduit sub main wiring with 4 single core 10 Sqmm copper conductor (Multistandered) in concealed PVC FRLS conduit of suitable size as required, with all fittings including 2 single core 6.0 Sqmm copper conductor as earth continuity complete all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.

850

-

-

... More
M&L for maintenance Free chemical earthing complete copper rod of not less than 32 mm dia, 3 meter long through suitable size bore including chemical back fill compound of 25 kg two bags with filling bottom to top complete as required with copper earth strip of size 20x3mm upto test point, PVC earthing pit cover complete all as specified and directed.

1

-

-

... More
Supply and fix IP 65/66 Thermoplastic Transparent polycarbonate PC- Grey colour (RAL 7035) Metering Box with multi level knockouts as well as from rear side also for cable entry only possible via flanges with transparents lid unprotected outdoor (UV resistance) with internally embedded gasket technology . The junction box shall fulfill the following standards IEC 60670-22: Particular requirements for connecting boxes and enclosures. IEC 60695-2-11: Glow wire tested at minimum 960 deg c , Impact Resistant : IK 08 (05 Joule) Halogen free in accordance with IEC 60754-2 size (600x600x170)mm Make: Hensel, ABB, Siemens

2

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.