Military Engineer Services Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date2 Sep 2023
Closing Date30 Sep 2023
Tender Amount₹ 18,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified.

49

-

-

... More
Supply and laying un-reinforced precast concrete cable cover class LV type-1 size 250mmx150mmx40mm complete as per specification.

3500

-

-

... More
Dismantling/taking down old existing unserviceable and Supply and Fix Energy saving and environmental friendly long life Versatile pressure die cast aluminium IP-65 surface /roof mounted highbay light fittings luminaire with high power,light weight LED of capacity 200 watt external surge protection complete all as specified Note:- The lights shall be fixed on highrised buildings, so arrangement i.e T&P for fixing light made by contractor without any extra cost.

10

-

-

... More
Dismantling/taking down old existing unserviceable and Supply and Fix Energy saving and environmental friendly long life Versatile pressure die cast aluminium IP-66 flood light fittings luminaire with high power, LED of capacity 120 watt external surge protection complete all as per specified . .

3

-

-

... More
Cutting of road, hard standing PCC for laying of cable and making good surface with existing to give the shape of cable trench as per site requirement as per directed by Engr-in-Charge

10

-

-

... More
Material and labour in replacement for 80 mm dia galvanized iron tube light grade for cable protection , road crossing, trenches, footpath etc, complete including clamps, nut bolt and washers as all specified and directed.

16

-

-

... More
Material and labour in replacement for 40 mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, complete all as specified including clamps, nut bolt and washers as all specified.

60

-

-

... More
Boring under road and foot path for inserting 40/80 mm bore GI tubing for drawing UG cable, complete all as per specified and directed.

15

-

-

... More
M & L earthing complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level, connected to galavanised iron earth lead by means of bolt, nut, check nut and washer of galavanised iron strip 32x6mm as earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 type C1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs, wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 all as directed by Engr-in-Charge

4

-

-

... More
Supply, Installation, testing and commissioning in replacement of high intensity 200 watt bi-pin lamp for runway lights complete all as specified.

20

-

-

... More
Supply, Installation, testing and commissioning in replacement of high intensity 200 watt bi-pin lamp holder for runway lights complete all as specified.

20

-

-

... More
Supply, Installation, Testing & Commissioning in replacement of Medium Intensity 45watt bi-pin lamp for runway taxiway lights. complete all as specified.

15

-

-

... More
M & L in finding and rectifying the fault in Runway/Taxiway lights by checking the circuit in series / light to light including excavation and Returning filling if required at site. complete all as specified Note:- Lamps, Lamp Holder, connectors, transformers, cables etc required in rectifying the fault will be measured and paid seperately under relevent items of Schedule.

20

-

-

... More
M & L in replacement for 5 KV grade plug and receptable of type - I class -B connector and suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core copper conductor cable as required and confirming to the specification as require.

30

-

-

... More
M&L in replacement for medium intensity 200 watt ,6/6.6 Amps,5KV,50Hz,0.95PF individual lamp series to series type isolating transformer encapsulated in polyester resin , finally moulded with neoprene type rubber compliant to FAA specification no. 150/5345-47C specification complete all as specified and directed by Engineer-in-charge.

12

-

-

... More
M&L in replacement for medium intensity 45 watt ,6/6.6 Amps,5KV,50Hz,0.95PF individual lamp series to series type isolating transformer encapsulated in polyester resin , finally moulded with neoprene type rubber compliant to FAA specification no. 150/5345-47C specification complete all as specified and directed by Engineer-in-charge.

10

-

-

... More
Supply and Laying in replacement 6 mm square 5 KV grade single core, stranded copper conductor PVC insulated & PVC sheathed, underground airport lighting cable generally.confirming to IS: 1554 Part-II 1981 with upto date amendment as required. complete all as specified.

500

-

-

... More
Supply and fix in replacement of transformer housing box made of FRP material suitble for receive a light base plate complete all as specified.

10

-

-

... More
Supply and in replacement flameproof ceiling fan regulator 230v 50Hz complete all as specified.

10

-

-

... More
Supply and fix in replacement flameproof switch socket and plug(2P+E) 16Amp 250V complete all as specified .

5

-

-

... More
Supply and fix in replacement flameproof switch socket and plug(3P+E) 16Amp 415V complete all as specified.

4

-

-

... More
Supply and fix in replacement flame proof spare Plug for 16 Amps 250V (2P+E) complete all as specified.

6

-

-

... More
Supply and fix in replacement flame proof spare Plug for 16 Amps 415V (3P+E)complete all as specified.

8

-

-

... More
Supply and fix in replacement LED light fiiting 2x16 watt flame proof ,CMRI certified recommended for gas/vapor group of IIA & IIIB Zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture driver,holder,connector etc,complete with all three core flexibble copper conductor cable with suitable size complete all as specified.

3

-

-

... More
Supply and fix in replacement Reflector for twin flameproof light fitting with LED rod complete all as specified.

12

-

-

... More
suply and fix in replacement flameproof rotary switch with cable terminal box in LM6 10 Amp single pole on-off complete all as specified .

10

-

-

... More
suply and fix in replacement flameproof rotary switch with cable terminal box in LM6 16 Amp single pole on-off complete all as specified.

10

-

-

... More
suply and fix in replacement flameproof Junction box 100 dia upto 4 way in LM6 complete all as specified.

2

-

-

... More
Supply and fix in replacement Flameproof Distribution board SPN 8 way Double door with 100 amps rated bus bar complete incoming MCB 2P 32Amp and outgoing single pope 6Amp- 08 nos complete all as specified.

2

-

-

... More
Supply and fix in replacement Flameproof Distribution board SPN 6 way single door with 100 amps rated bus bar incoming MCB 2P 32Amp and outgoing Single Pole 6Amp-04 Nos complete all as specified.

2

-

-

... More
Taking down carefully aluminium/copper point wiring of any type/size for Light, fan, socket or power complete including making good the disturbed surfaces finishing of wall / floor etc, complete all as specified.

33

-

-

... More
Taking down existing sub main wiring of any type/size complete from wall and making good the disturbed surface complete all as specified.

110

-

-

... More
M&L Point wiring with 1.5 Sq. mm PVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including In Stove enamelled steel Conduit (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screw etc complete all as specified for the following:-

-

-

-

... More
(a) One light point controlled by one switch.

10

-

-

... More
(b) One fan/ exhaust fan point controlled by one switch.

5

-

-

... More
(d) One switch socket out let point 5 Amps on independent board

5

-

-

... More
(e) One switch socket out let point 5 Amps on same board

3

-

-

... More
Material and labour for surface point wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of same size/specification for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of In stove enamelled Steel conduit with all fittings and accessories fixed properly on wall or ceiling including PVC terminal boxes for mounting switches socket for 3 pin 15 amp independent board all as specified and as directed by Engr-in-Charge.

10

-

-

... More
Material and labour for sub main wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 2.5 Sqmm and one run of size 2.5 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of Steel conduit with all fittings and accessories fixed with clamp properly on wall or ceiling as per specified as directed by Engr-in-charge

40

-

-

... More
Material and labour for sub main wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 6 Sqmm and one run of size 6 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of Steel conduit with all fittings and accessories fixed with clamp properly on wall or ceiling as per specified as directed by Engr-in-charge

30

-

-

... More
Material and labour for sub main wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 10 Sqmm and one run of size 10 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of steel conduit with all fittings and accessories fixed with clamp properly on wall or ceiling as per specified as directed by Engr-in-charge

40

-

-

... More
S&F in repair/replacement Metal Clad Plug and socket with box 20 Amp with MCB complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm complete all as specified.

10

-

-

... More
Supply,fixing and testing in replacement of LED 45W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire complete all as specified.

10

-

-

... More
Supply,fixing and testing in replacement of LED 75W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire complete all as specified.

14

-

-

... More
Supply,fixing and testing in replacement of LED 100W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire complete all as specified.

16

-

-

... More
Supply,fixing and testing in replacement of LED 150W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire complete all as specified.

10

-

-

... More
Supply and fixing in replacement of LED PCB board for 45/60KW light fitting board thickness 1.6mm for Flood/street/highbay light fittingcomplete with connection complete all as specified.

8

-

-

... More
Supply and fixing in replacement of LED PCB board for 90/100KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete with connection complete all as specified.

10

-

-

... More
Supply and fixing replacement of LED PCB board for 150 KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete with connection complete all as specified.

7

-

-

... More
S&F in repairs Galvanised iron wire 4mm dia with clips connecting upto runway light to light as series complete all as specified.

500

-

-

... More
Supply and fix relay PCB board high capacity flux protection NO contact form rated coil voltage 110 Volts AC to 12 volts AC supply single pole 10 Amps suitable up to 5 Ton crane complete all as specified.

2

-

-

... More
M&L for Overhauling of LT & CT Gear box and repalcement of unserviceable parts like input shaft, bearing and output shaft of the EOT Crane upto 5 Ton complete all as specified.

2

-

-

... More
Supply and fixing in repair Control Cable of 1 Sqmm of 24 Core PVC flexible copper Cable , operating temp 5 degree centigrade to 70 degree centigrade, Flame resistance including cable gland, terminations & testing etc.complete all as specified.

100

-

-

... More
Supply and fixing in repair of Control Cable of 2.5 Sqmm of 3 Core PVC flexible copper Cable , operating temp 5 degree centigrade to 70 degree centigrade, Flame resistance including cable gland, terminations & testing etc.complete all as specified.

75

-

-

... More
Supply and fixing in repair push button of complete set of EOT Flame proof crane upto 5 Ton as that of existing make as directed by Engineer-in-Charge.

1

-

-

... More
Supply and fixing in repairs 15 way flame proof pendent type control panel with push button of complete set of EOT crane upto 5 Ton as that of existing make as directed by Engineer-in-Charge.

1

-

-

... More
M&L for overhauling of main hoist helical Gear box of the EOT flame proof Crane upto 5 Ton and including replacement of the unserviceable parts like bearing, input shaft and outpur shaft as directed by Engineer-in-Charge.

1

-

-

... More
Disconnecting and taking down electromagnetic thruster / Hydraulic Brake unit from the EOT crane of any make and capacity up to 10 Ton, shifting to work shop, dismantling all parts, replacement of unserviceable parts like bearings, Brake coil, thruster oil, assembling, shifting to existing location and fixing in a same position, complete testing the system as per manufacturers instructions, and as directed by Engineer-in charge.Note : Supply only main hydraulic brake thruste unit, bearings & gear oil shall be measured and paid separtely under respective items of this schedule. Cost of all other minor spares required for replacement shall be included in the unit rate quoted.

1

-

-

... More
Supply only main hoist hydraulic brake thruster unit suitable for capacity upto 5 ton capacity of EOT crane complete all as directed.

1

-

-

... More
Supply and fix Long liver type 2 way limit switches suitable for CT & LT operation fo EOT Cranes of 5 Ton capacity complete all as specified and directed by Engineer-in charge.

2

-

-

... More
Supply and topup Gear oil Servo 120 Kinematic Viscosity cst @ 40 degree Centtigrade, 220- 250 Flash point (COC) 250 complete all as specified and directed by Engineer-in charge.

40

-

-

... More
Supply and fixing in repair Steel wire rope 12 mm dia complete all as specified and directed by Engineer-in charge.

100

-

-

... More
Supply only wheel bearing as per existing size for LT or CT side motor/gear box for upto 5 Ton capacity EOT Cranes complete all as specified and directed by Engineer-in charge.

1

-

-

... More
M&L for taking out of 2/3 HP induction motor and rewinding the motor with super enamelled copper wire as per specified/existing gauge/ size, complete all as specified.

2

-

-

... More
S&F in repair/replacement of ball bearing suitable for 3/5 HP motor complete all as specified.

5

-

-

... More
S&F in repair cable carrier arrangement from panel to motor including hanging arrangement of cable complete One side of door including all nut,bolt,washer etc all as specified & directed by EIC.

4

-

-

... More
S&F in repair PVC flexible copper conductor FRLS cable of size 1.5 Sqmm 2 core. Complete all as specified .

80

-

-

... More
S&F in repair PVC flexible copper conductor cable FRLS of size 1.5 Sqmm 3 core. Complete all as specified.

60

-

-

... More
S&F in repair PVC flexible copper conductor cable FRLS of size 2.5 Sqmm 4 core. Complete all as specified.

60

-

-

... More
S&F in repair PVC flexible copper conductor cable FRLS of size 1.5 Sqmm 6 core. Complete all as specified .

60

-

-

... More
M & L in repair and replacement of gear wheel of 30 cm dia having teeth 30 Nos of EOT crane with alignment as required on site complete all as specified.

2

-

-

... More
M & L in repair and replacement of MS Coupling of motor gear box of motorised door system with alignment as required on site complete all as specified .

2

-

-

... More
M & L for servicing of existing motor, gear box, wheels, chain, wheel track including cleaning, greecing, oiling, spare parts as required on site and alignment complete all as specified.

14

-

-

... More
Supply and fixing replacement of limit switches for auto power cut at suitable fixed destinations of master leaf both in opening and closing situations all as specified .

2

-

-

... More
M&L for rectify the alignment of bottom track rail till parking bay (end point) to make easy to electric traction for smooth operation of motorised hanger door and applying gresse on the track rail after removing the dust from track rail. The bottom track should be straight till parking bay at both extremities also arrange the iron brush for automatically cleaning bottom side of track till last ending of each side of parking leaf complete as per directed by EIC. Note:- One Hangar comprises four movable leaf which will be one Each job.

3

-

-

... More
M & L for PCC type B ratio 1:2:4 (using 20 mm graded stone aggregate) as in platform, base etc. complete with quick setting cement complete all as specified including demolition of existing PCC.

2

-

-

... More
M & L for PCC type B0 in the ratio of 1:2:4 (using 12.5 mm graded stone aggregated) as in platform, base etc. complete including finishing the surface with quick setting cement including whitewashing and painting with synthetic enamel paint of all metal parts complete all as specified including demolition of existing PCC.

1

-

-

... More
Material and labour in replacement of Splicing of fibre cable with connector complete as specification.

1

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.