Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 30,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_681012_1Tender No
84244/C/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
M&L for dismantling the cylinder heads from diesel engine and sent to foundry work (work shop) for calibration and repairs by replacing the spares such as Valves, Valve Guides, Valves seats and repairs kit and re-assembling to its original position with necessary Engine cylinder head gasket and O rings for DG Set of capacity 20 KVA to 30 KVA including testing complete all as specified and directed by engineer-in-charge.
1
-
-
All as pet Item No. 04.00 above but for DG Set of capacity 63 KVA complete all as specified and directed by engineer-in-charge.
1
-
-
All as pet Item No. 04.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
1
-
-
M&L for disconnecting all electrical connections from the unserviceable self starter of any type /make /model, opening and dismantling of self starter suitable for the DG set of capacity 20 KVA to 30 KVA for carrying out repair, complete overhauling of the system including replacing the unserviceable parts such as bearing, carbon brushes, clutch plates etc assembling and refixing the self starter in its original position and connecting all connections and testing complete all as specified and directed by engineer-in-charge.
Note:- Armature coil and D coil field shall be measured seperatly under relevent items of BOQ.
2
-
-
All as pet Item No. 07.00 above but for DG Set of capacity 63 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 07.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
Taking down old unserviceable armature coil from self starter for the DG set of capacity 20 KVA to 30 KVA, 12 volts and S&F armature coil suitable for any make/type of DG set of capacity 20 KVA to 30 KVA, 12 volts including testing complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 10.00 above but for DG Set of capacity 63 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 10.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
M&L for removing the defective charging dynamo of capacity 24 volts DC of any type / model / make of any capacity and opening it by removing all nuts and bolts, cleaning with necessary cleaning agent and overhauling and lubricating of the same replacing the armature and field coils reconnecting the same and refixing all items in original position testing and commissioning complete all as specified and directed by engineer-in-charge.
2
-
-
All as per Item No. 13.00 above but for 12 volts DC Charging dynamo complete all as specified and directed by engineer-in-charge.
2
-
-
M&L for disconnecting and dismantling of fuel pump assembly from its original position by opening of nuts and bolts, renewing of pump repair kit and fuel pipe refixing the same after overhauling including calibration and testing complete for the DG sets of capacity 20 KVA to 30 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 15.00 above but for DG Set of capacity 63 KVA ccomplete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 15.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
M&L for calibration of water pump complete, overhauling, replacing of gaskets, nuts, washers etc and reassembling the same and refixing the pump to the engine and testing including taking down the old unservicable water pump of any capacity of DG set from the engine and taking it to out side workshop, for the DG set of capacity 20 KVA to 30 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 18.00 above but for DG Set of capacity 63 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 18.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
M&L disconnecting the unservicable DC wiring from DG set of any type and rewiring the same with suitable new wire of existing guage by providing flexible pipe and testing complete for any type of DG set/make/size etc complete all as specified and directed by engineer-in-charge.
4
-
-
M&L disconnecting the oil cooler of any DG set of capacity 20 KVA to 30 KVA any make and model from the existing location duly removing of all the mechanical and electrical connections and including taking down the same for complete servicing, opening the connected parts and cleaning thoroughly by using with suitable material and acid complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 22.00 above but for DG Set of capacity 63 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 22.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
S&F in repair defective Turbo Charger Assembly duly disconnecting the mechanical and electrical connections from DG Set of capacity 100 KVA to 160 KVA, opening and thoroughly checking to carry out repairs complete to the Turbo Charger Kit and spares as required at site including any mechanical and reassembling and refixing the turbo charger assembly to its original position and reconnecting the same and including testing complete all as specified and directed by engineer-in-charge.
1
-
-
Draining out fuel from fuel tank of DG set of capacity 20 KVA to 30 KVA any type and keeping it in separate container safely, disconnecting all the fuel lines and other electrical and mechanical connections and taking out the fuel tank for cleaning of tank both internally and externally for removing all the accumulated dusts or sediments, leak testing the tank, welding and brazing including one coat of synthetic enamel paint and refixing the tank to its original position, replacing the drain plug and PVC pipe protecting with flexible pipe, calibrating the fuel tank, refilling the drained out fuel back in to the tank and marking of litres in guage and provision of locking arrangement complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 26.00 above but for DG Set of capacity 63 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 26.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
Supply only filling engine oil of grade 20W/40 for DG sets complete all as specified and directed by engineer-in-charge.
150
-
-
Supply and topping up of Acid Mixture suitable for Lead Acid Batteries of capacity 12V / 24V complete all as specified and directed by engineer-in-charge.
50
-
-
Supply and topping up of distilled water suitable for Lead Acid Batteries of capacity 12V / 24V complete all as specified and directed by engineer-in-charge.
100
-
-
S&F Automatic Voltage Regulator (AVR) suitable to DG set of capacity 20 KVA to 30 KVA including disconnecting of all electrical connections of existing unserviceable automatic voltage regulator of any size/make complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 32.00 above but for DG Set of capacity 63 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 32.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
Attending only complaints for any type of DG set of emergency basis to clear/rectify both electrical and mechanical faults of DG set installed at various locations under AGE (I) Pokaran complete all as specified and directed by engineer-in-charge.
20
-
-
S&F in replacement of Line Voltage Monitors (LVMS) of existing make to DG set of 100 KVA to 160 KVA capacity with all listed parameters including testing complete all as specified and directed by engineer-in-charge.
2
-
-
S&F in replacement of Rectifiers of existing Make to DG Set of 100 KVA to 160 KVA capacity with all listed parameters including testing complete all as specified and directed by engineer-in-charge.
4
-
-
S&F 12 V, 180 AH maintenance free battery suitable for DG set complete all as specified and directed by engineer-in-charge. Make :- AMARON/ EXIDE/ EXPRESS/CANON
2
-
-
S&F heavy duty battery cable lead of copper conductor with copper lugs terminal for the 12 V, 180 AH maintenance free battery suitable for DG set complete all as specified and directed by engineer-in-charge.
10
-
-
S&F battery brass terminal and jelly complete all as specified and directed by engineer-in-charge.
10
-
-
S&F in repair radiator assembly of DG Set of capacity 20 KVA to 30 KVA by unscrewing all mechanical and electrical connections from the existing mounting and disconnecting all the incoming and outgoing rubber hoses and draining out the water from the choked radiator assembly, transporting the same to civil workshop for carrying out servicing, opening the top and bottom covers of the radiator and cleaning throughly the chocked pipes of the radiator by using detergent like castic soda, cotton watse etc and refixing the same to its original position with suitable size of nuts and bolts, washers etc complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 41.00 above but for DG Set of capacity 63 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 41.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
S&F in replacement of microprocessor based control unit suitable to DG set of 100 KVA to 160 KVA capacity with all listed parameters including testing complete all as specified and directed by engineer-in-charge.
1
-
-
S&F in replacement of 'V' Belts for any capacity/make of DG Set complete all as specified and directed by engineer-in-charge.
5
-
-
S&F in replacement of Fan Belts for any capacity/make of DG Set complete all as specified and directed by engineer-in-charge.
5
-
-
S&F in replacement of Dinamo Belts for any capacity/make of DG Set complete all as specified and directed by engineer-in-charge.
5
-
-
Supply only coolant (DFC 50%) for DG sets complete all as specified and directed by engineer-in-charge.
50
-
-
S&F in repairs air cleaning element inner and outer with necessary 'O' ring for the DG set of capacity 20 KVA to 30 KVA as that of existing make and model complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 49.00 above but for DG Set of capacity 63 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
All as pet Item No. 49.00 above but for DG Set of capacity 100 KVA To 160 KVA complete all as specified and directed by engineer-in-charge.
2
-
-
S&F and testing run the Fly wheel Ring of existing model size suitable for DG set of any capacity including taking down old unserviceable fly wheel ring complete all as specified and directed by engineer-in-charge.
2
-
-
S&F 12 V, 80 AH maintenance free battery suitable for DG set complete all as specified and directed by engineer-in-charge. Make :- AMARON/ EXIDE/ EXPRESS/CANON
2
-
-
S&F 4 sqmm 2 core, 240 volts aluminium solid conductor cable heavy duty PVC insulated ISI marked complete all as specified and directed by engineer-in-charge.
450
-
-
S&F in repair LED street light fitting 35/45 Watt including replacement of unserviceable items like driver, module, controller any size of watt, and taking down LED street light, nut bolt, clamp and refixing after reapir on same pole etc complete all as specified and directed by engineer-in-charge.
30
-
-
S&F in repair LED street light fitting 60/90 Watt including replacement of unserviceable items like driver, module, controller any size of watt, and taking down LED street light, nut bolt, clamp and refixing after reapir on same pole etc complete all as specified and directed by engineer-in-charge.
27
-
-
S&F in repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by engineer-in-charge.
120
-
-
S&F in repair LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by engineer-in-charge.
30
-
-
S&F in repair LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed by engineer-in-charge.
25
-
-
M&L for cleaning down complete body including fitting and fixture of desert cooler of air flowing capacity 4000/5000 Cum/per hour of any make with wire including removal of all sludges, loose paints, dust, dirt etc and prepared the surface clean for painting and applying two coats of rubber based paint inside the water tank complete, including rewriting of MES No. complete all as specified and directed by engineer-in-charge.
100
-
-
S&F fan motor of single phase 230 Volt, 1400 RPM 3 speed 1/8 HP 20 Inch sweep for desert cooler including cast iron rings for motor with clamps nuts & bolts complete all as specified and directed by engineer-in-charge.
68
-
-
All as per Item No 61.00 above but fan motor 24 Inch sweep 900 RPM complete all as specified and directed by engineer-in-charge.
30
-
-
S&F PVC flexible pipe of 16 mm outer dia complete with PVC elbow, tee as required complete all as specified and directed by engineer-in-charge.
50
-
-
S&F desert cooler selector switches three way 230 Volts single phase of standared quality fixed in desert cooler complete all as specified and directed by engineer-in-charge.
30
-
-
S&F repair wood wool pad (set of three) minimum weight 0.8 Kg, proper fixed in 3 side of panels of desert cooler complete all as specified and directed by engineer-in-charge.
100
-
-
S&F in repair, plug top 3 pin 5 Amp with cable upto 2mtr, 230 Volt (ISI marked) complete all as specified and directed by engineer-in-charge.
30
-
-
S&F in repair, PVC insulated and PVC sheathed round flexible three core copper conductor cable of size 40/0.0076 Sqmm including making necessary connections for desert coolers complete all as specified and directed by engineer-in-charge.
50
-
-
S&F in repair capacitor 4 Mfd for fan motor of desert cooler complete all as specified and directed by engineer-in-charge.
40
-
-
Supply and replace water spray pump 1/30 HP for desert cooler complete all as specified and directed by engineer-in-charge.
80
-
-
S&F PVC fan blade for fan motor of desert cooler of 20 Inch sweep complete all as specified and directed by engineer-in-charge.
20
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%