Military Engineer Services Tender

... More
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date4 Feb 2025
Closing Soon24 Feb 2025
Tender Amount₹ 20,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
S&F in replacement of unserviceable Drier Core as per existing site complete all as specified and as per directed. Note:- Labour shall be included in item No 1. Make:- Danfoss.

2

-

-

... More
S&F in replacement of unserviceable Filter Drier all as per existing site complete all as specified and as per directed. Note:- Labour shall be included in item No 1. Make:- Danfoss.

2

-

-

... More
S&F in replacement for charging of Refrigerant R-134A in the system to its rating capacity to the extent to full fill required temperature conditions and service leak testing and complete all as specified and as per directed. Note:- Labour shall be included in item No 1.

220

-

-

... More
S&F in replacement of old temperature sensors in the incoming/outgoing water pipeline of the chiller unit all as per existing site complete all as specified and as per directed. Note:- Labour shall be included in item No 1.

2

-

-

... More
S&F in replacement of old pressure transducers on the chiller unit all as per existing site and specifications complete all as specified and as per directed. Note:- Labour shall be included in item No 1. Make: MCS Control/Danfoss or suitable equivalent.

2

-

-

... More
S&F in replacement of old driver for Expansion valve all as per existing site and specifications complete all as specified and as per directed. Note:- Labour shall be included in item No 1. Make: MCS Control/Danfoss or suitable equivalent

2

-

-

... More
S&F in replacement of old unserviseable Expansion valve all as per existing site and specifications complete all as specified and as per directed. Note:- Labour shall be included in item No 1. Make: MCS Control/Danfoss or suitable equivalent

1

-

-

... More
S&F in replacement of Switching Fuse Unit (SFU) in chiller unit panel of Cap-160-200 Amps complete all as specified and as per directed. Note:- Labour shall be included in item No 1. Make : Siemens/L&T or equivalent in C&S/CG

1

-

-

... More
S&F in replacement of HRC Fuse in chiller unit panel of Cap-160 Amps complete all as specified and as per directed. Note:- Labour shall be included in item No 1. Make : Siemens/L&T or equivalent in C&S/CG

3

-

-

... More
S&F in replacement of old unserviceable oil level switch on the chiller unit all as per existing site and specifications complete to the entire satisfaction of Engr-in-Charge Note :- Labour shall be included in item No. 1 Make : MCS Control/Danfoss or suitable equivalent.

1

-

-

... More
M&L for descealing of condenser alongwith connected pipe line system of c apacity 100 TR as per existing make and model including opening of condenser cover of both sides including disconnecting of water pipe line for inlet and outlet of the condenser of each plant. Removing scake / sludge precipitated in the copper tube by push and pull method with iron rod connected with steel wire brush of suitable size as per condenser copper tube size at the entire length of condenser that scraping down the sludge precipitated in side the tube. Closing both side of condenser and circulating the descaling soulation in all tube of plant through the circulating pump and allows holding it for 30 minutes for chemical reaction. Opening the condenser both sides and clean with iron road connected with nylon brush of suitable size as per condenser copper tube size at the entire length of condenser ensure that descaling process has been complete then closing the condenser at the both end and circulating clean waer in all the tube of condeneser and drian out the process will be continue till the satisfaction of Engr-in-Charge then fixing new gasket for both ends compressor unit-1 tighten with new nut end bolt for 100 TR capacity. complete all as specified and as per directed.

3

-

-

... More
Dehydration work of chiller Machine as per existing site complete to the entire satisfaction c

1

-

-

... More
M& L for removal of complete set of defective evaporator copper tubes hadrauilically and replacemeny with new finner copper tubes of dimension 19.05 x 1.12 x 3175mm for existing chiller model at site followed by nitrogen pressure testing complete all as specified and as per directed.

20

-

-

... More
M&L for complete servicing of condenser/chiller centrifugal pumpset of 20LPS and 12.5HP motor by engaging sufficient man power and suiatble T&P to ensure safety of pump-motor as well as working persons including disconnection suction and discharge water lines and removing of electric connection, dismantling the pumpset from MS Foundation including Greasing, Bearing replacement, Alignment of pump and refit the same complete all as specified and directed for the following capacities:- Note :-(i) The rate considered is inclusive of tools and plants required for carrying out the repairs. (ii) The rate considered is inclusive of cost towards miscellaneous items such as cotton waste, grease and other consumables.

6

-

-

... More
Supply only spares for Centrifugal Pumpset 20 LPS, Capacity 12.5 HP Make of Pumps-KIRLOSKAR

-

-

-

... More
Bearing Cast Iron Drive end / Non Drive end

3

-

-

... More
Bearing Housing

3

-

-

... More
Shaft sleeve Cast Iron drive end

2

-

-

... More
Round lock nut

3

-

-

... More
Seal Set (Make : Leak-Proof)

2

-

-

... More
Set of keys

1

-

-

... More
Pump Coupling set suitable for 12.5 HP condenser/chiller pump (cast iron made min 150mm dia with 04 Nos of nut, bolts and washer)

4

-

-

... More
NBR solid spider type jaw coupling L-150

12

-

-

... More
M&L for dismantling and Taking out defective monoblock pump of pipe size (80mm x 65mm) and head 18 to 40m and discharge upto 550 LPM , Make - Kirloskar from foundation and shifting it to workshop for replacement of Impellers, Bearings , seals etc complete. Refitting on foundation after repair testing and commissioning complete all as specified and as per directed.

1

-

-

... More
M&L for rewinding of Unserviceable motor of Cap-12.5 HP, type and make as per site including disconnecting unserviceable burn out winding completely, insulating materials and rewinding of the complete stator with super enameled copper wire of existing size applying proper insulation ‘F’ class varnish drying in oven, assembling, testing and commissioning complete all as specified and as per directed.

2

-

-

... More
All as per Sr item No 8 here-in-above but for the motor of Capacity 5 HP

1

-

-

... More
M&L for complete servicing to FRP based Cooling Tower of Capacity 100 TR by dismanteling PVC Honeycomb Fills, Coupling cooling Fan, sprinkellers, draining out of water, removing Algae, silt, cleaning complete cooling tower body by removing scale, dust, dirt, cleaning existing external surface and servicing of mechanical componenets and welding to cross members and frame bracing components incl repair of Bottom Tray (FRP Plate) of cooling tower with suitable water chemical (FRP resin), including replacement of gear box bearings, greasing and overhauling of the complete transmission system of cooling tower and re-assembling all the dismantled componenets to its original position, testing complete all as specified and as per directed. Note:- Spare parts shall be measured and paid for separately under respective item.

2

-

-

... More
S&F in repair/replacement of PVC Honeycomb fills for 100TR cooling tower incl dismantling/removing of old PVC fills as per site requirement (600mmx300mmx150mm) complete all as specified and as per directed.

280

-

-

... More
S&F in repair/replacement of Cooling Tower sprinkler system alongwith PVC connection pipes 40mm for cooling tower of capacity 100 TR, complete all as specified and as per directed.

2

-

-

... More
M&L for complete servicing to AHUs of Capacity 8000CFM complete with various accessories i.e. blower with casing, Chiller water coil, Hot water coil, pre filter & fine filter frame, drive motor, humidification kit, motorised control valves, control panel including descaling of chilled/hot water coils, Greasing, Lubricating of moving parts and Repair/Replacement of bush, thrust plate, gland packing, driver pully, driver shaft and re-assembling all the dismantled componenets to its original position, testing complete all as specified and as per directed. Note :- (i) AHU chilled/hot water coils using chemical with brass brush in-order to remove all type of sledge/dust precipitatated on the coil without any damage to the copper coil then wash the cooling with fresh water and air blower upto the satisfactory of Engr-in-Charge. (ii) Iron body of the AHU inside and outside shall be scrap down and rub out with sand paper then apply one coat primer over a coat of synthetic enameld paint including part of duct portion in the AHU shall be completed upto the satisfactory of Engr-in-Charge

8

-

-

... More
S&F in repair/replacement of AHU Pre Filter of Box Type for one AHU unit, Efficiency 90% down to 20 Microns of Size 610 x 610 x 50mm Depth and CFM - 8000 as per site requirement complete all as specified and as per directed. Make : Thermadyne, Camfil, Puromatic, Primide, Dyna

4

-

-

... More
S&F in repair/replacement of AHU Fine Filter of Bag Type For one AHU unit , Efficiency (95% to 98%) down to 10 Microns of Size 610 x 610 x 305mm Depth and CFM - 8000 as per site requirement. Make : Thermadyne, Camfil, Puromatic, Primide, Dyna

2

-

-

... More
S&F in repair of AHU motor suitable for AC plants/Dehumidifier unit/Air washer of motor capacity 7.5HP by dismantling it from weather making unit of AHU, replacement of Bushes, bearings by opening nuts bolts and removing electrical connections of the motor, replacement of V type Belt with new belt, replacement of stator and rotor assembly, winding of motor with Copper enameled wire of required thickness as existing, replacement and alignment of shaft, complete all as specified and as per directed.

2

-

-

... More
Supply and fix of CI Butterfly Valve of 65mm dia, ISI Marked PN-1.6, having Nitrile/EPDM rubber lining, SS stem, CS/SS Disc, Lever operated, including all jointing material i.e. Nut, Bolt, washer, Packing material etc duly insualted with checking, Testing and commissioning complete all as specified and as per directed.

1

-

-

... More
Supply and fix of CI Butterfly Valve of 100 mm dia, ISI Marked PN-1.6, having Nitrile/EPDM rubber lining, SS stem, CS/SS Disc, Lever operated, including all jointing material i.e. Nut, Bolt, washer, Packing material etc duly insualted with checking, Testing and commissioning complete all as specified and as per directed.

2

-

-

... More
Supply and fix of CI Butterfly Valve of 125mm dia, ISI Marked PN-1.6, having Nitrile/EPDM rubber lining, SS stem, CS/SS Disc, Lever operated, including all jointing material i.e. Nut, Bolt, washer, Packing material etc duly insualted with checking, Testing and commissioning complete all as specified and as per directed.

1

-

-

... More
M&L for replacement of power contactor 3 pole, type MNX-A1 with 2 NO + 2 NC Aux contracts, all as per existing site and specifications complete all as specified and as per directed. Make- L&T, C&S/AE.

5

-

-

... More
M&L for preventive maintenance of Water softening plant of Capacity 50m3/day comprising of the water softener, Non chemical type scale preventor of 150mm dia, for designed hardness 600PPM, product hardness 5 PPM Make: Indian Ion exchange complete alongwith periodic replacement of filters and softners and resin chemicals carried out in each month complete all as specified and as per directed. Note:- Material shall be measured and paid for separately under respective item.

4

-

-

... More
Strong Acid Cation Exchange Resin -Softener - 220 - Na+

40

-

-

... More
Strong Acid Cation Exchange Resin -Softener - 225 - Na+

40

-

-

... More
Supply and fixing in replacement of display unit of microcomputer of 100 TR water cooled screw chiller AC plant control panel with control card and motherboard as per OEM including preprogrammed software to control all parameter of Compressure and chiller unit complete all as specified and as per directed.

1

-

-

... More
S & F LT cable of control cable of 1100 v,1.5 sqmm, 6 core copper condutor PVC insulated PVC Sheathed , round wire strip armoured for AHU's LT panel complete all as specified and directed.

210

-

-

... More
S&F LT XLPE aluminium armoured power cable 4 core of size 25 sqmm 1100 volts grade heavy duty including all accessories for connection from panel board to MSD Shed unit incl testing and commissioning complete all as specified and directed.

250

-

-

... More
S&F LT XLPE aluminium armoured power cable 4 core of size 16 sqmm 1100 volts grade heavy duty including all accessories for connection from panel board to MSD Shed unit incl testing and commissioning complete all as specified and directed.

250

-

-

... More
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft / loose soil getting out and levelling of bottom surface to required level complete all as specified and as per directed.

227

-

-

... More
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 Cm thick soft / loose soil complete all as specified and as per directed.

130

-

-

... More
Removing excavated material (Soils) from site to a distance not exc 50 M away and depositing where directed at a level not exc 1.5mtr above the starting point complete all as specified and as per directed.

97

-

-

... More
Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches complete all as specified and as per directed. Note :- Punning thickness shall be measured.

65

-

-

... More
M&L for brick protection with sub Class`B` bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as specified and as per directed.

6.7

-

-

... More
S & F for laying galvanized steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 50mm bore complete all as specified and as per directed.

55

-

-

... More
Boring of holes under road, pavement, hard standing by trenchless technology using suitable tools and machinery for laying of pipe upto 150mm bore complete all as specified and as directed . Note :- GI pipe shall be measured and paid in concern Item

50

-

-

... More
M&L for Cleaning of 5000 ltr Tank complete all as specified and as per directed.

2

-

-

... More
S&F in replacement of M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 65 mm as per sample existing icluding bending and welding work and testing complete this job complete all as specified and directed.

18

-

-

... More
S&F in replacement of M S Pipes heavy grade with all fittings laid in floors or fixed to walls and ceilings etc of sizes 125mm as per sample existing icluding bending and welding work and testing complete this job complete all as specified and directed.

6

-

-

... More
Supply and fixing in replacement of dgital Hygrometer complete all as specified and as per directed.

1

-

-

... More
S&F in repair/replacement of MCB TPN 32 Amps 415 volt, Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified and as per directed.

17

-

-

... More
S&F in repair/replacement of MCB TPN 63 Amps 415 volt, Category- C curve, 10kA rapturing capacity ( ISI marked IS-8828) complete all as specified and as per directed.

5

-

-

... More
S&F in repair/replacement of MCCB 415V AC with thermal adjustable magnetic setting four pole 250 Amps complete all as specified and as directed. Make: Havells/Legrand/L&T

1

-

-

... More
S&F in repair/replacement of volt meter (0-500A) digital squire flush type of size 96x96 mm, three phase, with inbuilt selector including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder including taking out of unserviceable one complete all as specified and as per directed. Make: L&T/AE/C&S

5

-

-

... More
S&F in repair/replacement of Ammeter (0 - 200 A) digital squire flush type of size 96x96 mm, three phase CT operated CIR 5 amp, with inbuilt selector including necessary addition/ alternation of panel including cutting/welding of front side of panel board /feeder to match the existing panel board/feeder taking out of unserviceable one complete all as specified and as per directed. Make: L&T/AE/C&S

3

-

-

... More
Taking out of defective /unserviceable /obsolete model indicator lamp from LT panel AC plant, supply and fix indicator lamp LED type of different colour of existing, 60 mm dia 30 volts complete all as specified and as per directed. Make - Siemens/L&T//CG.

20

-

-

... More
M&L for single phase preventer model VSP 2, suitable to be fixed with FASD starter of any capacity for operation of the submerSI-ble pump motor, including taking out old U/S one complete all as specified and as per directed. Make :- Minilec (VSP 2) /L&T/ Legrand

4

-

-

... More
S&F in repair/replacement of relay ML 1.5 415 volt VAC, 50 Hz, current rating:-10-16 Amp to be fixed with FASD starter for operation of the submerSI-ble pump motor, including taking out old U/S one complete all as specified and directed by Engr-in-charge. Make :-L&T/ Legrand/ schinder

5

-

-

... More
S&F in repair/replacement of Ammeter Selector Switch with OFF for CT, 10 A including taking out old U/S one, complete all as specified and as per directed. Make:- Legrand / schnieder/ L&T

4

-

-

... More
S&F in repair/replacement of Voltmeter Selector Switch with OFF for 10 A -01 No including taking out old U/S one, complete all as specified and as per directed. Make :- Legrand / schnieder/ L&T

3

-

-

... More
M&L for cutting and dismantling the existing winding of exhaust fan 450mm sweep with super enamelled copper winding wire of suitable gauge including varnishing lubricating, greasing oiling testing complete all as specified and as per directed.

3

-

-

... More
S&F in repair/replacement of damaged insulation of chilled/hot water pipeline upto 150 mm thickness of thermo cole insulation 50 mm of density 16 Kg/Cum and insulated with thick resin bonded fiber glass and plaster by sand cement (1:3) complete suitable for above ground with all mounting arrangements like clamps with nut bolt etc, complete all as specified and as per directed.

95

-

-

... More
S&F in repair/replacement of water Pressure indicating Gauge fitted in water circulation circuit Range-0 to 100/150 lbs/Sq in and 0 to 7/10.6 Kg/Sq Cm complete all as specified and as per directed. Make- IEBIG/H-Guru/Gluck

7

-

-

... More
Detecting the fault of 3 x 100TR capacity of AC Plants and any location by providing skilled Refrigerent Mechanic/Skelled Elect & helper with necessary safety and working equipment such as ,multimeter ,speedometer and other reqd tools and plants and rectified the defects on top priority basis/as and when reqd including testing, complete all as specified and as per directed.

12

-

-

... More
Material and labour for chemical earthing complete with copper earth plate electrode of size 600mm x 600mm x 3 mm thick buried directly in ground(earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m deep below normal ground connected to and including copper earth strip 25 x 3 mm by means of copper bolts nuts check nuts and washer, returning & filling the pit with excavated soil mixing with charcoal 250 KG , Crystal salt 200KG , magnesium sulphate of 100 KG and vegetable soil all around the plate up to 350mm above from top edge of plate and balance portion filing with excavated soil in layers not exceeding 25mm thick, 25mm bore galvanised iron medium grade watering pipe up to top of plate, 50mm bore galvanisd iron light grade pipe for earth strip protection, including all excavation earth work in any type of soil, PCC 1:3:6 type C1 for chamber of internal size 300mm x300 x 300mm with 120mm thick wall and 700 mm x 700mm x 150mm thick, bed concrete, RCC 1:2:4, type B1 for precast chamber cover 50mm thick, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 Kg/sqm), funnel, with wire mesh, complete all as specified and directed. Note:- (i) Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length

4

-

-

... More
Taking out of old unsv GI strip and supply & fix copper strip of size 25 x 3 mm complete with insulator/saddle and fixing with screw/accessories for roof and down conductor complete all as specified and as directed

62

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.