Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Military Engineer Services - MES Tender
Civil And Construction
Pipe Line Project
Eprocure
Opening Date7 Nov 2024
Closing Soon28 Nov 2024
Tender AmountRefer Documents
Costs
EMD
₹ 60,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_682758_1Tender No
8184/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Cont... Note
(iii) : For each complaint in location, a docket slip shall be prepared by the contractor/ his representative and handed over to related tradesman, etc. for attending the complaint and after satisfactorily completion of complaint, docket slip shall be submitted to concerned executive on day of register of complaint, which shall be got signed from the occupant and shall be produced at the time of payment made to the contractor.
(iv) : Format of docket slip and complaint register which shall be kept in complaint cell will be provided by department .Stationery i.e. log sheets, docket slips, job cards, complaint registers, handing taking registers, etc. shall be provided by the contractor without any exta cost to the department and cost thereof shall deemed to be included in quoted rates by the contractor against respective item of schedule 'A'. The complaint slip shall be prepared by the contractor or his authorised rep and handed over to the tradesmen and necessary entry shall be made in the complaint register and will be handed over to to concerned JE / the Engr-in-Charge next day. Contractor shall maint seprate register for lodging the complaints and the same shall be produced to concerned JE / Engr-in-Charge on next day.
-
-
-
S&F gun metal gate valves of 15mm bore with iron wheel head screwed both ends for GI pipe including taking down old unserviceable, complete all as specified and directed by Engr-in-Charge.
4
-
-
S&F gun metal gate valves of 20mm bore with iron wheel head screwed both ends for GI pipe including taking down old unserviceable, complete all as specified and directed by Engr-in-Charge.
45
-
-
S&F gun metal gate valves of 25mm bore with iron wheel head screwed both ends for GI pipe including taking down old unserviceable, complete all as specified and directed by Engr-in-Charge.
30
-
-
S&F gun metal gate valves of 40mm bore with iron wheel head screwed both ends for GI pipe including taking down old unserviceable, complete all as specified and directed by Engr-in-Charge.
20
-
-
S&F gun metal gate valves of 50mm bore with iron wheel head screwed both ends for GI pipe including taking down old unserviceable, complete all as specified and directed by Engr-in-Charge.
20
-
-
Taking up or down steel tubing GI pipelines/ connection from trenches including connected fittings/accessories of 80mm bore, complete all as specified and directed.
150
-
-
All as per ser item No. 8.00 here-in-before but of 50mm bore, complete all as specified and directed.
450
-
-
All as per ser item No. 8.00 here-in-before but of 40mm bore, complete all as specified and directed.
450
-
-
All as per ser item No. 8.00 here-in-before but of 25mm bore, complete all as specified and directed.
880
-
-
All as per ser item No. 8.00 here-in-before but of 20mm bore, complete all as specified and directed.
980
-
-
All as per ser item No. 8.00 here-in-before but of 15mm bore, complete all as specified and directed.
100
-
-
Supply & laying Galvanised tubing 80mm bore, 'Medium grade', ISI marked as per IS 1239 part-I with all fittings ISI marked including cutting, threading etc as per site requirement and drilling holes/fixing clamp set for taking branch connection from main pipe line in trenches/road/ nallah & fixed along walls/polls including mild steel clamps, screws etc, complete all as specified and directed by Engineer-in-Charge. Note:- Earthwork shall be measured and paid seperately.
150
-
-
All as per ser item No. 14.00 here-in-before but 50mm bore, complete all as specified and directed by Engineer-in-Charge.
450
-
-
All as per ser item No. 14.00 here-in-before but 40mm bore, complete all as specified and directed by Engineer-in-Charge.
450
-
-
All as per ser item No. 14.00 here-in-before but 25mm bore, complete all as specified and directed by Engineer-in-Charge.
880
-
-
All as per ser item No. 14.00 here-in-before but 20mm bore, complete all as specified and directed by Engineer-in-Charge.
980
-
-
All as per ser item No. 14.00 here-in-before but 15mm bore, complete all as specified and directed by Engineer-in-Charge.
100
-
-
Taking up CI/DI/GI water mains 80mm dia from trenches (including all fittings), with spigot and socket ends and lead/tyton/Flanged joints including burning out joints and recovering lead, complete all as specified and directed.
150
-
-
All as per ser item No. 20.00 here-in-before but size100mm bore, complete all as specified and directed.
180
-
-
All as per ser item No. 20.00 here-in-before but size150mm bore, complete all as specified and directed.
33
-
-
All as per ser item No. 20.00 here-in-before but size 200mm bore, complete all as specified and directed.
22
-
-
Supply & laying ductile Iron pipes of 80mm bore with spigot and socketed or Flanged ends, Class “K-7”, as per IS 8329-2000 including fixing of tyton rings or fixing of MS flange, complete all as specified and directed.
150
-
-
All as per ser item No. 24.00 here-in-before but size100mm bore, complete all as specified and directed.
180
-
-
All as per ser item No. 24.00 here-in-before but size150mm bore, complete all as specified and directed.
33
-
-
All as per ser item No. 24.00 here-in-before but size 200mm bore, complete all as specified and directed.
Note for ser item no 24.00 to 27.00 :- (i) Earthwork and excavation required shall be measured and paid seperately.
(ii) Rate of tyton rings/flanges are included in the quoted rate.
22
-
-
M&L in replacement including jointing and testing of cast iron sluice valves of size 80 mm bore class PN-1.6, conforming to IS : 14846 flanged ends drilled having Stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washer etc, complete all as specified and directed by Engineer In charge.
2
-
-
All as per ser item No. 28.00 here-in-before but 100mm (4'') dia, complete all as specified and directed by Engineer In charge.
4
-
-
All as per ser item No. 28.00 here-in-before but 150mm (6'') dia, complete all as specified and directed by Engineer In charge.
4
-
-
All as per ser item No. 28.00 here-in-before but 200mm (8'') dia, complete all as specified and directed by Engineer In charge.
3
-
-
All as per ser item No. 28.00 here-in-before but 250mm (10'') dia, complete all as specified and directed by Engineer In charge.
2
-
-
S&F in replacement CI non return valve of size 80mm bore without by pass arrangement type conforming to IS:5312 with flanged ends, swing type including nuts, bolts, washer and rubber gaskets, complete all as specified and directed by Engr-in-charge.
2
-
-
All as per ser item No, 33.00 here-in-before but 100mm(4'') dia, complete all as specified and directed by Engr-in-charge.
4
-
-
All as per ser item No, 33.00 here-in-before but 150mm(6'') dia, complete all as specified and directed by Engr-in-charge.
6
-
-
All as per ser item No, 33.00 here-in-before but 200mm(8'') dia, complete all as specified and directed by Engr-in-charge.
4
-
-
All as per ser item No, 33.00 here-in-before but 250mm (10'') dia, complete all as specified and directed by Engr-in-charge.
2
-
-
Taking up old unserviceable Air valves, and M&L for air release valve with two air out lets confirming to IS 14845 of size 50mm dia bore and fixing in DI/GI/CI water supply mains of size 50mm to 150mm dia with all fittings, complete all as specified and directed by Engr-in-charge.
6
-
-
M&L for CI/DI specials such as tees, bends of any size and radius, tapers, collars, tail pieces, caps and plugs etc, complete all as specified and directed by Engr-in-charge.
250
-
-
Taking up existing DI pipe line of size 80mm and removing old unserviceable tyton joint (push-on-joint) and supply , fixing and testing of tyton joint (push-on-joint) or D joint as per site requirement and relaying the pipe line, complete all as specified and directed by Engr-in-charge.
6
-
-
All as per ser item No. 40.00 here-in-before but 100mm(4'') dia, complete all as specified and directed by Engr-in-charge.
18
-
-
All as per ser item No. 40.00 here-in-before but 150mm(6'') dia, complete all as specified and directed by Engr-in-charge.
12
-
-
All as per ser item No. 40.00 here-in-before but 200mm(8'') dia, complete all as specified and directed by Engr-in-charge.
Note for ser item No 40 to 43:-(i) Excavation and eathwork shall be paid separately.
(ii) Incase existing DI pipe line damaged during taking up the same shall be replaced with new DI pipe of existing size, rate shall be included in quoted rate.
6
-
-
S&F in repair PVC float valve 20mm dia high pressure with polythene float and fly nuts complete screwed for GI pipe and fixed, complete all as specified and directed.
10
-
-
Excavation in trenches not exc 1.50 metre wide and not exc 1.50 metre deep in soft/ loose soil for laying of pipe line and getting out, complete all as specified and directed.
500
-
-
Returning filling in, including spreading leveling, watering and well ramming in layers not exc 25cm, complete all as specified and directed.
450
-
-
Removal of excavated soil surplus to the requirement to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
50
-
-
Taking out sluice valves refacing, regrinding and refixing including replacing spindle and check nut and make serviceable of size 100mm to 350mm bore size complete all as specified and directed by the Engr-in-Charge.
8
-
-
M&L for repairing to existing CI/DI/MS pipe line, leakage by caulking of lead joint or any other means like fixing a clamp with rubber sheet at the place of leaking joints in running water pipe line or D joint including necessary material, complete all as specified and directed by Engr-In- Charge.
Note:- 200mm/150mm/100mm/80mm bore CI/DI pipe and fitting such as clamps or any other fittings if required whill be provided by the contractor and its cost is included in the quoted item rate.
15
-
-
M&L for scraping old existing paint from pipes of different sizes or any other surfaces including making smooth surface and primer and applying two coat of synthetic enamel paint of existing/ approved colour, complete all as specified and directed by Engr-in-charge.
150
-
-
Complete removal of the wild grass/ vegetation from surrounding area of OHTs, Tubeswells/ Boosters and installations area and making the surface clear and plain and spraying roundup chemical on the same clean area as directed after removing and depositing the same at a distance not less than 50 mtr away from the site, complete all as specified and directed.
Note- All necessary T&P will be provided by the contractor and no extra amount will be paid for that seperately.
1800
-
-
Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) un- reinforced, complete all as specified and direcetd.
10
-
-
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundation , filling and mass concrete, complete all as specified and direcetd.
10
-
-
Demolition of old valve pit M&L for construction of brick masonry valve pit of size 120cmx120cmx120cm (Type 'B') (internal dimensions) of chamber, depth of chamber to be reckoned from the top of PCC in foundation to top of MS cover and including MS sheet cover fabricated from 3.15mm thick MS sheet and frame of angle iron 50mmx50mmx6mm with fixing arrangement, hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide on MS cover and frame including necessary excavation earth work in any type of soil returning, filling in, disposal of surplus soil, PCC (1:2:4) work, complete all as specified and direcetd.
4
-
-
Demolition of old valve pit M&Lfor construction of brick masonry valve pit of size 90cmx90cmx90cm (Type 'B') (internal dimensions) of chamber, depth of chamber to be reckoned from the top of PCC in foundation to top of MS cover and including MS sheet cover fabricated from 3.15mm thick MS sheet and frame of angle iron 50mmx50mmx6mm with fixing arrangement, hinges and locking arrangement and painting two coats of synthetic enamel paint over a coat of red oxide on MS cover and frame including necessary excavation earth work in any type of soil returning, filling in, disposal of surplus soil, PCC (1:2:4) work, complete all as specified and direcetd.
6
-
-
S&F for flex board of minimum size 4feet x 3 feet, complete all as specified and directed by Engr-in-Charge.
Note:- Detail of printing material for flex will be provided by department.
12
-
-
M&L for rubber moulded machine pressed precast concrete interlocking paver with grey cement confirming to IS -15658-2000 of 60mm thickness , M-35 grade as in path , hard standing etc laid over and including 25mm compacted sand cushioning , including 75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate including surface excavation over area not exc. 30cm deep and averaging 15cm deep and getting out in soft/loose soil and removing excavated soil exc 50 mtr but not exc 250 mtr , at any site as per requirement including demolition of existing complete all as specified and directed by Engr-in-charge
66
-
-
Note:- Since this work pertains to water supply of station so timely action is the utmost essential criterion, so action shall be initiated within 8 hours after receiving order ( through Phonecall, Text message, site Order or any other means) from Engineer in charge/JE E/M, if due to any unavoidable circumstance contractor is not able to perform the work within 8 hours then work shall be initiated by next morning/Day with proper justification about unavoidable circumstance to Engineer In charge, else Rs 500/- per delay day penalty shall be imposed over the contractor, Decision of Engineer In charge/ Accepting officer shall be final in this regard.
-
-
-
Contract Amount shall be derived after affecting the amount of Schedule of Credit in General Summary on serial page No 17 of tender documents.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%