Military Engineer Services Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_689878_1Tender No
8453/24-25/E8Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick soil complete all as specified & directed by Engineer-in-charge.
102
-
-
... More
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soft/ disintegrated rock complete all as specified & directed by Engineer-in-charge.
11.01
-
-
... More
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge.
11
-
-
... More
Removing excavated soft/ disintegrated rock to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed by Engineer-in-charge.
29.81
-
-
... More
M&L for plain cement concrete (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified & directed by Engineer-in-charge.
4.54
-
-
... More
S&F rolled mild steel roof trusses (framed), trussed, purlins, crane, gantries, rails and fastening and heavy bracket framing (Beams, tee, angle, channel or flat sections) including distance pieces, cleat etc conforming to Fe-410-W Gde E-250 quality-A complete all as specified & directed by Engineer-in-charge.
6195.51
-
-
... More
S&F plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment. Fe 410-W (Gde-E-250) quality -A complete all as specified & directed by Engineer-in-charge.
995.38
-
-
... More
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5cm and dia of neck 16 to 20mm complete all as specified & directed by Engineer-in-charge.
118.78
-
-
... More
Use and waste of formwork to sides of concrete foundation, footing, base of column, raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to batter to rough finish surface of concrete flat complete all as specified & directed by Engineer-in-charge.
30.72
-
-
... More
M&L, reinforced cement concrete (design mix) M-25 grade (20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified & directed by Engineer-in-charge.
3.46
-
-
... More
M&L for mild steel TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-charge.
296.16
-
-
... More
M&L for mild steel TMT bars 5mm to 10mm dia as in stirrups, spacers & binders, cut to length, bend to shape required and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-charge.
329.14
-
-
... More
Use and waste of formwork to soffits of floor or roof beams, beam haunching ,grider, bressumber, lintels,cantilever ,sleves including supports ,over hang etc also splay between floor and beams to rough finish surface of concrete flat complete all as specified & directed by Engineer-in-charge.
48
-
-
... More
M&L, reinforced cement concrete (design mix) M-25 grade (20mm graded stone aggregate) as in beams, cantilevers, bressummers, lintels over 1.5m span etc complete all as specified & directed directed by Engineer-in-charge.
5.28
-
-
... More
S&F Pre-painted galvalume aluminium zine coating GI based corrugated steel sheeting 0.50mm thick any colour having tensile strenght 550Mpa in roof coverings fixed with self tapping screws complete all as specified & directed by Engineer-in-charge. Note :- (i) The fixing of Galvalume roof sheet as in sun-shades & in walls at certain places to be fixed by making of grooves cutting 75mm minimum with making good surface are inlcuded in the cost of item itself. No extra cost shall be paid for the same. (ii) The pattern and design of sunshades to be fixed as per directions of Engr-in-charge.
243.1
-
-
... More
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed by Engineer-in-charge.
170
-
-
... More
M&L for precast cement concrete (1:3:6) type C1 (using 20 mm graded stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar (1:6) complete all as specified & directed by Engineer-in-charge.
40
-
-
... More
S&F chicken mesh wire netting 25 gauge supplied and fixed on wall ceiling with nails complete all as specified & directed by Engineer-in-charge. Note : Rate of scaffolding upto 4 stories buidling include in this rate
40
-
-
... More
M & L for rendering 10mm thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in CM 1:6 to be finished even and smooth (without using extra cement complete all as specified & directed by Engineer-in-charge.
166.54
-
-
... More
M & L for rendering 15mm thick on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in CM 1:4 to be finished even and smooth (without using extra cement complete all as specified & directed by Engineer-in-charge.
189
-
-
... More
M & L for prepariation of new plastered surfaces complete all as specified & directed by Engineer-in-charge.
355.54
-
-
... More
M & L for providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified & directed by Engineer-in-charge.
355.54
-
-
... More
M & L for plastic emulsion paint complete all as specified & directed by Engineer-in-charge.
166.54
-
-
... More
M & L for Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed by Engineer-in-charge.
189
-
-
... More
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified & directed by Engineer-in-charge.
18.75
-
-
... More
M&L for hardcore of gauge not exceeding 63 mm of broken bricks/ stone or boulders, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified & directed by Engineer-in-charge.
22.5
-
-
... More
M&L for 75 mm thick cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub base of flooring/ hard standing path & finishing the surface even & fair without using extra cement complete all as specified & directed by Engineer-in-charge.
150
-
-
... More
M&L 25 mm thick plain cement concrete (1:2:4) type type B-0 (using 12.5 mm graded stone aggregate) as in floor for receiving screed bed complete all as specified & directed by Engineer-in-charge.
150
-
-
... More
M&L virified Ceramic tiles 10 mm thick dark shade / double charged (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over and including 15mm thick screed bed in CM 1:6 provided with 3mm thick joints accomplished by providing PVC spacers and joints filled with epoxy filling complete all as specified & directed by Engineer-in-charge.
150
-
-
... More
M&L 75mm PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection and hard standing including providing contraction joints with wooden spacers complete all as specified & directed by Engineer-in-charge.
24.3
-
-
... More
S&F PVC insulation panels with EPS stuck to but 1mm printed PVC sheet suitably placed in false ceiling grid made of Aluminium / G.I./M.S. complete all as specified & directed by Engineer-in-charge. Note :- Thickness of PVC insulation panel 10mm.
150
-
-
... More
S & F anodised aluminium snap grid frame work for false ceiling including all accessories hangers etc complete all as specified & directed by Engineer-in-charge.
150
-
-
... More
M & L for Granite of black / green / imperial red (colour .) of any type machine cut as in shelves /steps /counter tops, 20 mm thick, set and jointed in cement slurry over & including screed of 15 mm thick / rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab or with suitable adhesive including rubbing, cutting and mirror type polishing and bull nose on exposed sides complete all as specified & directed by Engineer-in-charge.
10
-
-
... More
S&F for Powder coated 50 microns extruded aluminium glazing/ doors including shutters made out of section 63.5x38.10 x 1.20mm for chowkats or frame & shutters made of size 44.45x44.45 x 1.29mm for side rails and middle rail, 114.3X44.45 X 1.29mm for top rails and bottom rails and including 12mm thick High Density Fibre Board pre-laminated on both sides (water proof) below middle/lock rail and 5mm thick tinted glass above middle/lock rail and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beads 20mm size with and incl mortice lock with duplicate keys etc complete all as specified and directed including supply and fixing the following items:
(a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm - 3 nos per leaf. (b) Powder Coated Aluminium Tower Bolt 200mm long - 2 nos per leaf (c) Powder Coated Aluminium Handles 150 mm - 2 nos per leaf
25.2
-
-
... More
Providing and fixing powder coated 50 microns extruded aluminium in 3 Tier Track Sliding Windows/glazing, with frame of section 100x44-45x1.30mm, track of size 100x38.10x1.30 & shutters made of size 32x18x1.3mm, with and including 4mm thick tinted sheet glass selected quality fixed in 2 shutters and stainless steel wire gauge 0.36mm nominal dia of wire and average width of aperture 1.40mm in one shutter and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size and also including powder coated 150mm handle with built in locking system for each leaf complete all as specified & directed by Engineer-in-charge.
6.75
-
-
... More
S&F PVC (SWR) pipes, single socketed, in any length , with rubber rings, bends etc 110mm dia complete all as specified & directed by Engineer-in-charge.
40
-
-
... More
M&L for providing Sikacrete®-145 IN is factory designed pourable, shrinkage compensated, free flowing and self-compacting superior performance microconcrete with selected cement, aggregate and other chemicals. Recommended water and coarse aggregate maximum 15% of bag to be added at site as per manufacturer instruction. Product should strictly meet the requirement of Compressive strength @28 days ~50 N/mm2 (ASTM C109)/ Flexural strength @28 days ~7 N/mm2 and Tensile adhesion strength @≥ 2 N/mm2 (28 days, +30 °C) (EN 1542) or as per manufacturer instructions and mixing concrete with mechanically electrically operated mixer machine etc complete all as specified and directed by Engineer-in-charge.
10
-
-
... More
M&L for providing aliphatic acrylate based anti carbonation protective coating system for concrete/ masonry surfaces comprising of the following : - (a) Preparation of surfaces including dusting to receive new treatment. (b) Applying one coat of Silane/Silaxone blend primer @ 0.125 ltr/Sqm or covering 8.0 Sqm/Ltr using portable spray equipment of the knapsack type. (c) Applying polymer under coat over completely dired primer surface using brush or roller to achieve a uniform coating with wet film thickness of not less than 250 microns (coverage not more than 2.5 Sqm/ltr). (d) Applying aliphatic acrylate pigmented top coat (Shade as approved by GE) to a uniform wet film thickness of not less than 125 microns (coverage not more than 8.00 Sqm/ltr).
310
-
-
... More
Note for item No. 40 & 41 :- (i) Rate of item are inclusive of material, labour, tools and tackle, scaffolding etc complete. (ii) The structural rehabilitation treatment shall be applied by the company’s authorized applicator only. (iii) Contractor have to get prior approval of applicator or authorized agency by submitting its authorization letter to this office for approval prior to commencement of work. (iv) Submission of 10 year warranty certificate for waterproofing treatment work over roof is mandatory after completion of work. (v) The cost of Scaffolding work required at certain places is including in the respective items catered for repairs itself. No extra shall be paid for the same.
-
-
-
... More
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 including water proofing compound and finished even & smooth without using extra cement with taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed by Engineer-in-charge
Note : (i) WPC to be paid separately under item Ser No 3 as supply only. (ii) The cost of scaffolding or any other type of wooden/iron fabricaction required to execute the work is included in the cost of item itself. No extra shall be paid for the same.
300
-
-
... More
Supply only liquid integral waterproofing compound @ 100ml/per 50kg cement used complete all as specified & directed by Engineer-in-charge .
11
-
-
... More
M&L Point wiring used approved colour coding as per IS (Red, Black and Green) for single phase circuits), with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. in and including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 Sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-
Note : Modular switch and socket shall be measured and paid separately
-
-
-
... More
a) One light point controlled by one switch
22
-
-
... More
b) One fan point controlled by one switch
4
-
-
... More
(c) One 2/3 Pin socket outlet 6 amp controlled by one switch on the same board with other switches.
2
-
-
... More
All as per item No 45 here on before but with copper conductor cable of nominal class area 2.50 sq mm for phase ,neutral & earth for One 2/3 pin socket outlet 5 Amps on independent board.
8
-
-
... More
All as per item No 45 here on before but with copper conductor cable of nominal class area 4.0 sq mm for phase, neutral & earth for power socket point 15 A .
4
-
-
... More
S&F modular switch one way 6A, 1 module complete all as specified & directed by Engineer-in-charge.
36
-
-
... More
S&F modular socket 6A-2/3 pin combined 2 module complete all as specified & directed by Engineer-in-charge.
10
-
-
... More
S&F modular switch socket combined 6A/16A , 6 pin, 3 module complete all as specified & directed by Engineer-in-charge.
4
-
-
... More
S&F step type modular fan regulator 120W -2 module ISI Marked with valid CML No complete all as specified & directed by Engineer-in-charge.
4
-
-
... More
S&F ceiling rose, 3 phase/PVC/ polycarbonate, isolated body complete all as specified and directed by Engineer-in-charge.
12
-
-
... More
S&F vertical DBs TPN 4 way 415 V double door powder coated, CRCA steel sheet constructed as per IS : 8623, degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 250 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces as required, suitable for TP/FP MCCB as incomer including MCCB 100A 16 KA, 415 V complete all as specified & directed by Engineer-in-charge.
1
-
-
... More
Supply and fixing MCB's single pole 6 Amps to 32 Amps, 240 Volts, 10 KA rapturing capacity 'C' curve complete all as specified & directed by Engineer-in-charge.
12
-
-
... More
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) concealed conduit circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00 Sqmm (FRLS) in conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified & directed by Engineer-in-charge. Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable as earth wire and one run of PVC conduit shall be measured and paid as one unit length.
20
-
-
... More
S&F surface and wall mounted LED tube light along with fixture, 4 ft, 20W, extruded aluminium housing provided for efficient heat disspation with polycarbonate, operating voltage 240 V, 50HZ, AC supply and operating tempureture 0 to 50 C, power factor 0.9, lumen output 2000 and provision of new 3 core multistanded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe omplete all as specified & directed by Engineer-in-charge.
10
-
-
... More
S&F of recessed/ ceiling mounted down lighter with CRCA housing with high bright LED, idealy suited for low ceiling areas Brilliance 36 Watt LED, size 2ft x 2ft The product features color tuning from 3000 K to 6500 K, necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified & directed by Engineer-in-charge.
10
-
-
... More
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified & directed by Engineer-in-charge.
2
-
-
... More
S&F galvanised iron bracket of 'medium grade' pipe 40 mm bore, length 1.20m, bend to required shape with 2 Set clamps made of 40x6mm FI and suitable size of bolts, nuts & washers, etc duly painted with two coats of aluminium paint over a coat of red oxide primer complete for fixing street light fittings complete all as specified and directed by Engineer-in-charge.
2
-
-
... More
S&F ceiling fans complete with three blade, down rod, accessories 230 V, 1200 mm sweep necessary connecting cable recommended / provided by manufacturer complete all as specified & directed by Engineer-in-charge.
4
-
-
... More
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron wire 4 mm dia as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion complete all as specified & directed by Engineer-in-charge.
1
-
-
... More
NOTE FOR ITEM No. 61.00
[i]. Excavation & earth work in any type of soil including removing of surplus material upto 100M
[ii]. PCC (1:3:6) type C1 using 20mm graded stone aggregate in pit & 40mm thick precast RCC (1:2:4) type B1 cover 50x50 cm with 8mm round bar @ 15 cm C/C both ways.
[iii]. Main earthing wire from earth electrode to test point upto 7.5 mtr.
[iv]. Funnel with watering pipe [GI pipe] 20mm bore [ISI marked] medium grade & copper lugs and charcoal & salt as reqd.
[v]. GI protection pipe of size 40 mm bore light grade 7.5m.
-
-
-
... More
Supply, laying, testing and commissioning of cable LT XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 volt grade with stranded aluminium conductor of size of cross sectional aera 50 Sqmm 3½ core with cable lugs, gland, cable termination box etc complete all as specified & directed by Engineer-in-Charge.
Note : - Earthwork excavation sand cushioning, Jodhpur Stone patti, GI protection pipe shall be measured and paid separately in their respective items
170
-
-
... More
M&L for sand cushioning to under ground cable using tibba sand and gently punning to cushioning to cable complete all as directed by Engineer-in-Charge.
(Note :- Punned thickness of sand cushioning shall only measured for the purpose of payment).
10
-
-
... More
Supply & laying 40 to 50mm thick roughly hammer dressed Jodhpur stone patti cable cover 25cm to 30cm wide and n. exc 60cm long each laid dry abutting with each other with maximum gap between adjacent slabs n. exc 10mm complete all as specified & directed by Engineer-in-charge.
21
-
-
... More
Material and labour for cutting the existing bituminous road / hard standing to size not exceeding 45cm wide and depth not less than 45cm for passing of UG cable through GI pipe and making good the disturbed surface filled with excavated material and top 200mm depth with plain cement concrete (1:3:6) type C1 (using 20mm graded stone aggregate) complete all as specified & directed by Engineer-in-Charge.
12
-
-
... More
S&F steel water tubing 50 mm bore, 'light grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors in trench on pole for protection of cable etc complete all as specified & directed by Engineer-in-charge.
12
-
-
... More
Supply, installation, commissioning & testing of hi wall split type air conditioner of capacity 1.5 TR, indoor/outdoor complete with cordless remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity system omplete all as specified & directed by Engineer-in-charge.
2
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA complete all as specified & directed by Engineer-in-charge.
2
-
-
... More
Supply and fixing AC plug & play 25 Amps all-in-one device complete all as specified & directed by Engineer-in-Charge. Make :- Havells DBOXX SRCD Cat Part No.- DHDDCDP025202503 or equivalent in Appx 'C' list of makes.
2
-
-
... More
S&F circuit/submain wiring alongwith earth wire with 2x4.0 sq. mm + 1x4.0 sqmm earth wire of FRLS PVC insulated copper conductor, single core cable with and including PVC conduit medium gade of size 25mm recessed including making good the distrubed surface as per existing surfaces complete all as specified and directed by Engineer-in-charge.
(Note :- Two runs of 4.00 Sqmm wire & one run of 4.00 Sqmm earth wire and one run of PVC conduit shall be measured and paid as one unit length)
120
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%