Indian Oil Corporation Limited Tender
If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.
Costs
EMD
₹ 9,900Document Cost
Refer DocumentsTender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_WRCHK_179191_1Bid Award Id
ViewTender No
CHTS242530Tender Authority
Indian Oil Corporation Limited ViewPurchaser Address
-Website
http://https://www.iocl.com/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Notice Inviting Tender for the work of Replacement, Relocation and Standardization of Test Lead Points in VC section under WRPL Chaksu Base
Special_Instructions_to_the_Bidders_20230207_version_1a
BOQ Items
... More
Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricate Type c (With Ingress Protection IP:55) Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-03 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge. Broadly, following material is required in this types of TLPs which is to be supplied by contractor: C type TLP: Test Lead Point as per drawing, 50-70 mtrs single core 6 sqmm armoured Cu cable, corrosion coupon along with magnetic reed switch & shunt & 6 sqmm unarmoured Cu cable, thermite - epoxy material etc.
1
27630
23415.67
... More
Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricate Type D (With Ingress Protection IP:55) Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-03 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge. Broadly, following material is required in this types of TLPs which is to be supplied by contractor: D type TLP: Test Lead Point as per drawing, 50-60 mtrs single core 6 sqmm armoured Cu cable, corrosion coupon along with magnetic reed switch & shunt & 6 sqmm unarmoured Cu cable, thermite - epoxy material etc.
1
21329
18076.18
... More
Test Lead Point : Supply, installation, testing & commissioning of Test Lead Point (TLP) fabricated MS Sheet with hinged front door, Heavy Guage MS pipe 100 mm nominal diameter, Phenolic laminated terminal plate, brass terminal bolts, neoprene gasket for front door, vandal proof concealed lock, etc as per latest revision of Standard AFC drawing (9200-99900-404-603-03 : STD-483). The work includes providing requisite concrete foundation of 600 mm x 600 mm x 800 mm at site, including MS hard pipe for cable entry through foundation, erection of the TLP over concrete foundation, termination of cables to the brass terminal bolts inside TLP box, jointing the cables to pipe (using cad welding/ pin brazing technique), repairing the damage to coat & wrap (with coating repair etc.), back filling the trenches, cleaning the site, applying epoxy paint / powder coating etc. The work also includes supply, installation, laying & termination of all XLPE, Cu cables of required length (as per site conditions) and size, lugs etc. The work includes supply and fixing of a non-corrosive name plate containing the details like KM location, identification, TLP No., direction of flow, connection scheme, type etc., on the side of the TLP box, etc. The name plate shall also include the details of corrosion coupon wherever installed, all as per the direction and specification detailed in the document complete with tools, tackles & other necessary requirement. The work complete in all respects including all materials, tools, tackles, labour as per tender specifications, AFC drawings & directions of the Site Engineer/Engineer-In-Charge. Broadly, following material is required in this types of TLPs which is to be supplied by contractor: DAC type TLP: Test Lead Point as per drawing, 20-30 mtrs single core 6 sqmm armoured Cu cable, 10-20 mtrs single core 25 sqmm armoured Cu cable, corrosion coupon along with magnetic reed switch & shunt & 6 sqmm unarmoured Cu cable, thermite - epoxy material etc.
1
35320
29932.88
... More
Application of Powercrete R-95: Flood coating by R-95 Powercrete Liquid epoxy paint (Consisting Part A & Part B mixed in ratio as per manufacture recommendation over mainline pipe/ leak clamp/ sleeve etc. including surface preparation as per tender specification & application of liquid epoxy paint (Powercrete R-95) over finished surface. The cost includes all materials( liquid epoxy R-95) consumables, labour etc. The thickness of flood coating shall be 900-1000 micron. On the Coating defect locations where new TLPs will not be installed.
9
78145
7358.32
... More
Excavation: Earth work in excavation in all kinds of soil, both wet & dry condition (except hard rock requiring blasting, chiselling / pneumatic drilling) for foundation, substructures, trenches, sumps, pits etc. to the following depths including shoring, strutting, trimming of sides of the trenches, dressing, ramming and levelling the bottom of the trenches correct to level, grade etc. including bailing out of water (if any), stacking selected excavated earth for backfilling, filling available excavated earth in trenches, foundation, plinth etc. and/or disposing the excess earth outside IOCL premises to an unobjectionable area with all leads & lifts, etc. complete in all respects inclusive of cost of all labour, materials, tools, tackles etc. as per drawings, specifications and direction of the Site Engineer/EIC. All kind of soil except hard rock (Measured from original ground level)- Excavation and backfilling items will be executed for the locations where old TLPs will be removed and new TLPs will not be installed.
28
9944
300.97
... More
Backfilling: Backfilling of Excavated Pit / Trecnch:Backfilling of the excavated pit/trench by Hydraulic means (JCB)/Manual Means, soil (excluding rock) removed during excavation of trench (stored within 50 m radius of the excavated trench). Excavation and backfilling items will be executed for the locations where old TLPs will be removed and new TLPs will not be installed.