Ajmer Vidyut Vitran Nigam Limited Tender

If you're looking for Rajasthan tenders online and are tired of typing tender ID over and again or going through the cumbersome government websites for it, you are in luck. We have collated every Eproc Rajasthan tender on BidAssist. And for any queries related to an e-tender Rajasthan, like bidding process, registration process, etc., are explained below. Read on.

Ajmer Vidyut Vitran Nigam Limited - AVVNL Tender

Works
Eprocure
Opening Date10 Jul 2018
Closing Date26 Jul 2018
Tender Amount₹ 37,61,039 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Levelling of ground

-

-

-

... More
1.3.1 Levelling of ground up to 30 cm.depth. with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder.(Including all lead & lifting)

1500

2505

1.67

... More
1.4 Trimming of tree branches/plants manually/ by machine and preparing route approchases for proposed line/line maintenance work of existing HT/LT lines.

75

2492

33.23

... More
CHAPTER NO. 2 - EARTH WORKS INCLUDING FOUNDATION ACTIVITIES

-

-

-

... More
Excavation of pit in ordinary rock which does not require blasting/murrad to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.

-

-

-

... More
(B) Lattice Tower /Size of pit

-

-

-

... More
2.3.4 11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep

47

68260

1452.36

... More
2.3.5 12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep

13

22564

1735.76

... More
(C)Stay set/Depth of pit

-

-

-

... More
2.3.6 8'x 3/4" -0.75x0.5x1.6 m

4

1030

257.63

... More
Excavation of pit in Hard rock ( Where blasting is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.

-

-

-

... More
(B) Lattice Tower /Size of pit

-

-

-

... More
2.4.4 11.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep

49

143972

2938.22

... More
12.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep

30

96519

3217.32

... More
(C)Stay set/Depth of pit

-

-

-

... More
2.4.6 8'x 3/4" -0.75x0.5x1.6 m

17

12508

735.8

... More
CHAPTER NO.3 : TRANSPORTATION OF MATERIAL

-

-

-

... More
Safe carriage of steel( fabricated and unfabricated) I.e.M.S. Rails, R.S.Joists, M.S.Channels, M.S.Angles, M.S.Flat, G.I.Stay Sets, G.I. Stay Wire, G.I.Wire Nut & Bolts etc. and ACSR Conductor including loading and unloading and stacking in Nigam store /at work site

-

-

-

... More
3.2.1 Within 10 Kms.

23

8300

360.89

... More
Safe Carriage of insulator, hardware, cable etc.including loading/unloading and stacking in Nigam.stores etc.

-

-

-

... More
Within 10 Kms.

42

18166

432.53

... More
Safe carriage of fabricated lattice towers structures and sub-station structures type AB, AB beams, isolators structures etc. including loading/unloading and stacking in the Nigam. Stores / at work site.

-

-

-

... More
Within 10 Kms.

51

26830

526.09

... More
Safe carriage of 11/.4 KV 3 Phase distribution transformer including loading/unloading.from store to site (These charges will be 1.5 times for both sides )

-

-

-

... More
a) 10 & 16 KVA

-

-

-

... More
3.5.1 Within 10 Kms.

1

217

217.77

... More
Safe Carriage of 33/11 KV Power Transformer

-

-

-

... More
c) 5.0 MVA

-

-

-

... More
3.9.1 Within 10 Kms

1

5631

5631.83

... More
CHAPTER NO.4 : LOADING AND UNLOADING OF MATERIAL

-

-

-

... More
Safe loading of power/ distribution transformer.

-

-

-

... More
(A) 33/11 KV power transformer.

-

-

-

... More
4.2.3 5 MVA

1

5580

5580.74

... More
Safe unloading of power/distribution transformers

-

-

-

... More
a) 33/11 KV power transformer.

-

-

-

... More
4.4.3 Above 3.15 MVA

1

4727

4727.63

... More
CHAPTER NO.5 : ERECTION OF SUPPORTS & STAYS

-

-

-

... More
Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The nuts & bolts will be provided by the contractor as per Nigam's specification for which payment will be made at the prevailing store issue rates. The cost muffing and grouting will be paid extra.

-

-

-

... More
5.1.3 Lattice Structure

46.5

251921

5417.67

... More
Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming.The work includes fixing of stay clamps.Stay insulator with stay wire at both ends with proper tension.Size of stay set/stay wire

-

-

-

... More
5.4.1 8"x3/4" with 7/8 SWG stay wire

21

6488

308.99

... More
Erection & fixing of steel struts in the excavated pit in position.The top end of the strut will be properly holed/welded with the main support muffed in cement concrete of ratio 1:3:6 as per item No.5.7.The nuts and bolts will be provided by the contractor as per Nigams specification for which payment will be made at the prevailing store issue rate.The cost of muffing and grouting will be paid extra.

-

-

-

... More
5.5.3 Lattice Structure

2

7558

3779.13

... More
Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement,river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21days in steel plates shuttering /farmer base.

420

1314411

3129.55

... More
Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station.

5

17510

3502.08

... More
CHAPTER NO.6 : ASSEMBLY & INSTALLATION OF VARIOUS ITEMS

-

-

-

... More
Fixing of guarding Bracket arms with clamp on erected support as per design. The nuts &bolts will be supplied by the contractor as per Nigams specification for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
6.4.1 33 KV line

12

657

54.8

... More
6.9 Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 nos .disc.& 1set of H/W) on terminal point including fixing of hardware and strips.

100

5204

52.04

... More
6.11 Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 2 nos.disc.& 1set of H/ W ) on terminal point including fixing of hardware and strips.

120

4472

37.27

... More
6.13 Fixing of 33kv pin insulator with pins.

212

3493

16.48

... More
Assembly. Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system. The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(B)G.O. switch . without earthing blade.

-

-

-

... More
6.16.3 33kv G.O.switch

12

14792

1232.69

... More
6.16.4 11kv G.O.switch

22

21092

958.74

... More
Assembly and installation of Horn Gap fuse set (set of 3nos)on erected structure as per design, complete in all respectwith post insulator including jumpering on both ends for connection with the system. The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
6.17.2 11kv Horn Gap fuse set.

1

493

493.12

... More
Installation of lightening arrestors on erected structure /support (1 nos) including connection with earth by wire /strip as required and jumpering etc. The nuts & boltswill be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
(A)sub-station type

-

-

-

... More
6.19.1 33 KV L.A.(each)

12

2273

189.45

... More
6.19.2 11 KV L.A. .(each)

18

2958

164.37

... More
Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of steel structure set for sub-station as per requirment jumpering on HV&LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect. The PG clamps nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,

-

-

-

... More
6.20.2 25 and 40 KVA

1

688

688.23

... More
6.22 installation of LT MCB (Distribution Box) on sub -station structure .The nuts & bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates,including connection on both ends with suitable lugs duly crimped (lugs & cable will be supplied by Nigam)

1

131

131.56

... More
6.28(c)Fixing of PG clamp of Panther Conductor

260

2277

8.76

... More
CHAPTER NO.7 : STRINGING OF CONDUCTOR/ EARTH WIRE

-

-

-

... More
Laying ,jointing , stringing, tensioning and clamping of conductor with proper sag as directed , using bolted type hardware including binding on pin insulators,jumpering on section points with binding wire / P.G.clamps.Aluminium jointing sleeves will be used for jointing the conductor.The line must stand at proper voltage on charging.The contractor will be provide P.G.clamps for which payment will be made as per prevailing Discom issue rate.

-

-

-

... More
(A) IN URBAN AREA

-

-

-

... More
7.1.1 ACSR PANTHAR

9.2

81497

8858.43

... More
Laying , jointing,stringing,tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc.including proper binding at each end.The nuts and bolts will be supplied by the contractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(A) IN URBEN AREA

-

-

-

... More
7.3.1 G.I.Earth wire 6 SWG

0.5

567

1134.11

... More
Drawing & stringing of G.I. 4 wire over the guarding bracket for guarding of road crossing /P&T crossing /Railway track crossing (for one span only)with cross G.I.wire laces at an interval of two meter each or required as per location using EYE bolt, nuts and bolts with washers etc.including binding .The EYE bolts and other nuts and bolts will be provided by thecontractor for which payment will be made as per prevailing Discom store issue rates.

-

-

-

... More
(A) For 4 wire stringing

-

-

-

... More
7.4.1 6 SWG with laces of 8 SWG

10

9365

936.59

... More
CHAPTER NO.8 : EARTHING OF LINE AND SUB-STATIONS

-

-

-

... More
Mesh earthing for 33/11 kv sub-station as per approved map &design usingMS flat 50X6mm/MS road 20mm dia includinglaying of flat/rod at the depth of 0.65 Mtrs.,welding & jointing at joints , structures & equipments etc.asunder:

-

-

-

... More
Excavation of trench of 0.65Mtrs.depth and 0.5Mtr.width

-

-

-

... More
8.3.1(c)Ordinary rock ( where blasting is not required.)

100

33147

331.47

... More
8.3.1(d)Hard rock ( where blasting is required.)

250

245737

982.95

... More
Laying of MS flat /MS rod in 0.65Mtr.deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.

500

14255

28.51

... More
8.3.3 Shaping of MS flat for connecting the equipments with earthmesh .The work includes the welding of MS flat with equipments/structure and also with earth mesh.The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.

250

10735

42.94

... More
Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr.length as per design and requirment to be driven in earth by mechanical means and Providing & .fastening of suitable clampswith the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:

-

-

-

... More
8.3.4(b)Where drilling is required

54

37284

690.45

... More
8.3.5 Filling of trench with available excavated muck in layers of 20cm (Max.)consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.

400

2272

5.68

... More
8.3.6 Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.

200

1580

7.9

... More
8.5 Earthing of new 33/11 KV S/S with bentonite compound (including material ) involving following activities.

10

62690

6269.05

... More
Digging of 10.5 ft. deep pit of 4 ' dia ( approx 132 cu.ft)

-

-

-

... More
Supply of 2" G.I pipe with cap(including fabrication of 30 holes in the periphery of pipe)

-

-

-

... More
Making chamber for water pouring including cast iron manhole cover

-

-

-

... More
Supply cost of 200 kg bentonite compound with making slurry

-

-

-

... More
Supplu of black cotton soil approx 80 cu.ft.

-

-

-

... More
Connecting electrode with Mesh Earthing

-

-

-

... More
CHAPTER NO.10 :ERECTION OF 33KV SUB-STATIONS & BUS BAR

-

-

-

... More
Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod ,33KV /11KV insulator strings,required hardware,P.G.clamps/T clamps etc.as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.

-

-

-

... More
10.3.1 ACSR PANTHER

1200

40428

33.69

... More
CHAPTER NO.11 :LAYING OF HT/LT CONTROL CABLE INSTALLATION OF C&R PANEL KIOSKS BREAKERS ETC.

-

-

-

... More
Laying of HT/LT control cable installation of C&R panel Kiosks Breakers etc.

-

-

-

... More
Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization,filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.

-

-

-

... More
11.1.2 33 KV VCB/SF-6 Breaker

4

22226

5556.68

... More
11.1.4 11 KV VCB (Outdoor )

6

33340

5556.68

... More
Installation of control panel including checking of wiring and conducting all pre-commissioning tests before energization, satisfactory operation of all equipment existing thereof. ( The relay will be tested by Discom ).

-

-

-

... More
11.2.1 33 KV Control Panel

4

5483

1370.76

... More
Installation of current/potential transformers on supporting structure including checking of wiring & conducting all pre-commissioning tests before energization & satisfactory operation in all respect (The CT/PT set will be tested by Discom).

-

-

-

... More
11.3.1 33 KV CT(1 set of 3 Nos. ) OR PT Set

5

6853

1370.76

... More
11.3.2 11 KV CT(1 set of 3 Nos.) OR PT Set

1

1370

1370.76

... More
Erection & commissioning of battery set and battery charger including all required connection/wiring from battery set to battery charger and A.C.mains complete in all respect.

-

-

-

... More
110 Volts D.C.

1

1370

1370.76

... More
Laying, testing termination of control cable 1100 volts PVC insulated including supply and installation of ferrules to designate various cores of control cables by terminal Nos. of identification including utilization of cable gland. The control cable should be clearly arranged in trenches avoiding crossings including clamping of control cable at regular interval and providing identify tags.

-

-

-

... More
11.5.1 2x2.5 Sq.mm.

200

2976

14.88

... More
11.5.3 4x2.5 Sq.mm.

700

13965

19.95

... More
11.5.6 12x2.5 Sq.mm.

300

8196

27.32

... More
11.6 Supply andFixing of metallic junction box size 450x300x250 mm outdoor type floor mounting fabricated out of cold rolled steel sheet 16 SWG with required branching and support of M.S. Angle 45x45x5mm The box should be printed with the coat of Zinc Chromate primer and 2 coats of light grey paint. Removal of gland plate of 3 mm.

10

28192

2819.23

... More
Laying, connecting, testing and commissioning of 1100 Volt PVC cable at 33/11 KV Sub-Station including connections of leads cutting stripping of cable insulation providing compression type terminals fixing of cable glands crimping of lugs clamping of cable cores etc. complete in all respect as per requirement of Engineer Incharge. PVC cable size.

-

-

-

... More
11.7.1 4 Core 6 Sq.mm. to 25 Sq.mm.

100

1750

17.5

... More
Supply,transportation and laying of sand layer of 75 mm below the power cable and 75 mm above the same alongwith using 200x100x75 mm size Class-II bricks in channel shape comprising of following sizes as under the back filling in the layer of compacted 100 mm thick earth,. Cable will be laid as per the methods of IS:1255 and details in 11.13

-

-

-

... More
11.8.2 For Double Power cable, the trench width will be 470 mm using 35 Nos of bricks of above specification.

75

11360

151.47

... More
Providing and fixing of G.I. Pipe B-Class (IS:1239 marks) at the starting and finishing point of 33 & 11 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.

-

-

-

... More
11.11.2 Providing and fixing of G.I. Pipe of 150 mm diameter. B-Class (IS:1239 mark),at the starting and finishing point of 33 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.

120

207400

1728.34

... More
CHAPTER NO.12 :PAINTING WORKS

-

-

-

... More
Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper.(including cost of red oxide)

-

-

-

... More
12.1.1 On new surface

2350

84576

35.99

... More
Painting with aluminium paint of approved brand and manufacturer to give an even surface.(including cost aluminium paint)

-

-

-

... More
12.2.1 On new works with two coats.

2350

126853

53.98

... More
CHAPTER NO.14 :FABRICATION

-

-

-

... More
Fabrication of steel structures of M.S angle ,M.S.channel & M.S.Flat including cutting ,drilling and continunous welding joint as per design and drawing.

-

-

-

... More
14.2.7 Other steel items

37.5

184023

4907.28

... More
Drilling of holes in MS Channel / Angle /Flat

-

-

-

... More
14.4.2 13/16" dia holes(20.63 mm dia.)

1000

4750

4.75

... More
14.4.3 11/16" dia holes(17.46 mm dia.)

1250

5937

4.75

... More
CHAPTER NO.20 :ERECTION & COMMISSIONING OF CABLE

-

-

-

... More
Laying of two (D/C) 11 KV, XLPE, Cable (Al. conductor) underground cable w/o overlapping as per relevant IS/JVVNL standards including excavation of 50 cm width x120 cm deep trench in Kaccha land, 25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.

-

-

-

... More
20.2 a) 3x35 Sq mm to 3x185 Sq mm

250

46357

185.43

... More
Installation of cable termination / straight through joints on 11KV Aluminium conductor XLPE Cable with outdoor/ indoor termination end and /or straight through joint including required excavation / remoral/ fixing / refixing/ testing etc. as required

-

-

-

... More
20.3 A) (I) Outdoor end terminal 3x35 Sq mm to 3x185 Sq mm

4

4579

1144.75

... More
Laying of two ( D/C) 33KV, XLPE (Aluminium conductor) underground cables w/o overlapping as per relevant IS/ JVVNL standard including excavation of 50 cm width x 120 cm deep trench in Kaccha land.25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.

-

-

-

... More
20.5 B) 3x 240 Sq mm to 3x400 Sq mm

1100

279851

254.41

... More
Note:- per meter shall be paid extra for excavation in Pakka Road.

40

3962

99.06

... More
Intallation of 33 KV Cable (XLPE) termination / straight through joints ( Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required.(Including crimping of lugs)

-

-

-

... More
20.6 (ii) 3x240 Sq mm to 3x400 Sq mm

12

20985

1748.79

... More
20.6(ii)Straight through joint 3x240 Sq mm to 3x400 Sq mm

8

29846

3730.78

... More
CHAPTER-25 (A) : SUPPLY OF MATERIAL OF HT METERING ON DISTRIBUTION TRANSFORMER

-

-

-

... More
25.3 Supply of MS nuts & bolts

80

7310

91.38



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.