Northern Railway Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 1,06,700Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Telecom Work In C/w Crossing Of Various Gas Pipeline Under Railway Track Over Firozpur Division.
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
433-Sig-T-47-24-25-FEROZPUR DIVISION-S AND T/NORTHERN RLYTender No
433-Sig-T-47-24-25Tender Authority
Northern Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Supply of PLB-HDPE duct outer diameter 40 mm & inner diameter 33 mm as per 04 RDSO/SPN/TC/45/2013, Rev. 2.0, Amendment 1-3, or latest with all accessories as described in RDSO specifications. Material shall be procured from RDSO approved vendor or OEM supporting certificate shall be provided that the material has been manufactured as per specification attached. Inspection By Consignee
2.5
51875
129688.72
... More
Supply of 25mm. dia PVC Conduit Pipe(MMS) ISI marked as per:IS 9537 part-3 with all 05 required accessories (metal clamping ,Bends etc shall be provided by contractor). Inspection by Consignee. OEM supporting certificate shall be provided that the material has been manufactured as per specification attached. 06
2100
30
63483
... More
Supply of 1 KVA UPS . Make - APC, Microtek or similar. Inspection by Consignee.
10
6731
67319.8
... More
Supply of Optical Fiber jumper (Patch cord ) (10 m long) with LC to FC/PC connector at both ends as per RDSO/SPN/TC/69/2007 with latest amendments as per site requirement. Inspection by Consignee
30
589
17693.1
... More
Supply of optical fibre jumper cable (patch cord) ( 10 metre long) with FC-PC or SC/APC or suitable connector ) at both ends as per RDSO/SPN/TC/69/2007, Rev 0, or latest.The connector should be compatible with STM as per site requirement. Inspection by Consignee 09
25
451
11282
... More
Supply of RJ-45 Connector with cap.Make- D-Link or better.Inspection by consignee.
90
9
819
... More
Supply of Single mode 1G SFP module as per site requirement . Inspection by Consignee.
30
3496
104901.6
... More
Supply of 2 MB Modem as per RDSO Specification no. RDSO/SPN/TC/80/2013or latest. 011 Material should be procured from RDSO approved vendor or OEM supporting certificate shall be provided that the material has been manufactured as per RDSO specification attached. Inspection by Consignee.
5
16042
80213.6
... More
Supply of Intel Core i3 All in One PC with 23.8 Inch Display/ Windows 11 with 512GB SSD, 8GB RAM or better, make hp or similar for fault finding. Inspection by Consignee.
5
54756
273780
... More
Supply of 2MB programmable primary digital drop insert multiplexer with conference facility as per technical specification No.IRS/TC/68/2012, Rev. 0, or latest without maintenance portable terminal, fully wired for 30 channels with redundant power supply unit, remote control supervisory facility and all other accessories, installation material,technical manuals etc. The MUX 013 shall be supplied with full capacity of cards i.e. 1 card for 64 kbps(G.703), 1 card for 2W Hot line circuits, 2 card for 2W Subscriber interface circuits, 2 card for 2W exchange loop, 1 card for V.24 low speed data interface for SCADA, E1 branching Interface and rest cards for 4W E&M VF circuits Each card should preferably be of minimum 4 circuits except SCADA card of minimum 2 channels. This includes supply of Male/Female Jacks and accessories as required as per the Design of MUX. Inspection by RDSO.
5
150576
752883
... More
Supply of SMPS based battery charger for telecom use of 230VAC(90 VAC to 300 VAC)/48V DC, 25Amp capacity. This shall consist of modules of 25 Amp modules in 1+1 configuration 014 or 12.5A modules in 2+1 configuration with automatic switching between the modules as per RDSO specification no. RDSO/SPN/TC/23/99 (ver. 4),Amendment-1 or latest. This includes 10 Sq. MM copper wire in Red and Black colour for interconnecting charger to VRLA battery & equipment.Material should be procured from RDSO approved vendor or OEM supporting certificate shall be provided that the material has been manufactured as per RDSO specification attached. Inspection by Consignee.
2
90496
180993.26
... More
Supply of SDH Add/Drop MUX(STM1) for main stream at stations in cable hut/OFC equipment rooms per TEC GR No. TEC/GR/TX/SDH-004/04/Jan-11 or latest with L1.1 Optical 015 Aggregate Interface and as per technical requirements for OFC system, equipped with 21 E1s (including engineering order wire),expandable up to 63 E1s capacity simply by addition of E1 cards, fully wired, having cross connect granularity at VC-12, VC-3 & VC-4levels, power unit, sub-racks, 4port 10/100 Mbps Base-T Ethernet, installation materials with all other accessories and technical manuals etc. Inspection by RDSO.
2
169126
338252.22
... More
Supply, Transportation and connection of VRLA secondary Battery 48V/200AH with all 016 accessories with two no. manual of instructions with each set as per RDSO Specification no. S-93- 96,Amendment 1, or latest.Material should be procured from RDSO approved vendor or OEM supporting certificate shall be provided that the material has been manufactured as per RDSO specification attached. Inspection by Consignee.
3
94492
283477.47
... More
Supply, installation & commissioning of Power supply unit with 12V/7AH MF Battery 017 Backup & charging system for Way station equipment as per RDSO specification No. IRS/TC 72/97 or latest. Material should be procured from RDSO approved vendor or OEM supporting certificate shall be provided that the material has been manufactured as per RDSO specification attached. Inspection by Consignee.
25
735
18375
... More
Supply of rack mountable 24 port manageable Layer -2 switch with 4 nos 1000 Base X 018 SM SFP port and 24 nos GE port with all accessories as per RDSO spec. No: RDSO/SPN/TC/65/2021 or latest. Material should be procured from RDSO approved vendor or OEM supporting certificate should be provided that the material has been manufactured as per RDSO specification attached. Inspection by Consignee.
2
31509
63019.18
... More
Supply of 24 port layer 3 switch as per RDSO specification no. RDSO/SPN/TC/65/2016 019 Rev. 4.0 or latest. Material should be procured from RDSO approved vendor or OEM supporting certificate should be provided that the material has been manufactured as per RDSO specification attached. Inspection by Consignee.
2
167969
335938.32
... More
Supply, installation and testing of LAN extender as per RDSO spec no. 01 RDSO/SPN/TC/82/2013 rev 1.0 or latest. Material shall be procured from RDSO approved vendor or OEM supporting certificate shall be provided that the material has been manufactured as per specification attached. Inspection By Consignee.
5
11748
58740
... More
Supply & Installation of 8port 10/100/1000 Base TPOE with 2 or more 1000Base X port 02 layer 2 switch with required fiber module as per RDSO specification no.RDSO/SPN/TC/65/2016Rev. 4.0 or latest.Material shall be procured from RDSO approved vendor or OEM supporting certificate shall be provided that the material has been manufactured as per specification attached. Inspection By Consignee
5
26571
132859.65
... More
Supply and installation of Rack mounted Fiber Management System 19", with all installation material splicing termination and testing of 2X4 fiber of cable with all connectors and any other material required as per the instruction of site engineer. Inspection by Consignee.
10
28259
282597.7
... More
Supply and installation of Optical fibre cable joint enclosure as per RDSO/SPN/TC/ 68/2014, Rev.1.0,Amendment 1, or latest along with4 Nos. of Splice trays, accessories& Jointing 04 materials as mentioned in the Specifications and splicing of Optical Fibre cables (24 fibres) and testing. This includes provision of prefabricated/ RCC Joint pit as per RDSO/TCDO/COP-21. Material shall be procured from RDSO approved vendor or OEM supporting certificate shall be provided that the material has been manufactured as per specification attached. Inspection By Consignee
5
34234
171174.6
... More
Supply and installation of 9U 19'' Rack of Make- Verlack or APW or HCL with all accessories as per site requirement. Inspection by Consignee.
5
7436
37184.85
... More
Supply, Installation,Testing and commissioning of Managed Media Converter 06 (Ethernet/E1to Optical) as per RDSO/SPN/TC/103/2013 Rev.2 or latest. Material should be procured from RDSO approved vendor or OEM supporting certificate should be provided that the material has been manufactured as per RDSO specification attached. Inspection by Consignee.
5
7260
36300.25
... More
Supply, Installation, testing & Commissioning of UPS (online) 5 KVA as per RDSO 07 Specification no. RDSO/PE/SPEC/PS/0023- 2001(Rev-0) Amendment no. 2 or latest with 120 minutes battery backup. Inspection by Consignee. Material shall be procured from RDSO approved vendor or OEM supporting certificate shall be provided that the material has been manufactured as per specification attached.
2
139486
278973.38
... More
Excavation and refilling of trench in normal soil to the level of ground with rammed 01 earth as per Drg. No. NR/S&T/CON/1.1/97-A so as not to form a drain 0.3 mtrs. Wide & 1.2 mtr. Deep on both side of the station alongside the track. It shall be conform to the safe distance as per signalling and cable route plan. it also includes clearance of roots of tress and bushes. Inspection by site engineer.
1
65381
65381.41
... More
Trenchless boring ( by using HDD or manual pushing method) for PLB HDPE pipe/GI 02 pipe at built up areas, platforms, culverts, track crossing, road crossing as per approved cable route plan. Depth of boring shall not be less than 1500mm from bottom of Rail flange/Road level.Inspection by Site engineer.
1.5
559741
839612.34
... More
"Laying/insertion of PLB-HDPE duct in the trenches/cutting/Trough and HDD/Manual Boring portion including supply & provision of pulling of Nylon rope through it at different places as per directions of engineer in charge with proper couplers / end plug arrangement". Inspection by Site engineer.
-
-
3
... More
"Blowing/Drawing of OFC through PLB-HDPE / GI pipe by mechanical system." Inspection by Site engineer.
2.5
8946
22365.13
... More
Fixing & laying of PVC Conduit Pipe /PVC Capping-n-casing (channel). As per instructions by Consignee.
2100
9
20034
... More
Laying of CAT-6/Power cable/OFC in PVC Conduit pipe of 25 mm Dia ISI mark ( PVC pipe with all accessories to be supplied by Contractor). Inspection by Site engineer.
2100
9
20097
... More
Installation and commissioning of 2MB programmable drop/insert MUX inside standard closed rack fully equipped with all types of interface cards. Inspection by Site engineer.
5
10644
53223.05
... More
Installation and commissioning of STM-1 along with additional cards as required inside 08 the standard closed rack with all 21 E1s of all installed E1 cards duly wired upto U-link panel and line side fibre patch cords duly terminated and working for the concerned section being commissioned , and for future add/drop simply by addition of more E1 cards. The item also includes supply of al, wires/cables as required for interfacing to U-link panel. Inspection by Site engineer.
2
17600
35201.96
... More
Installation, wiring and commissioning of SMPS battery charger including installation of batteries and charging.Inspection by Site engineer.
2
2680
5360.6
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%