Northern Railway Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Northern Railway - NR Tender

Works
Electronics Equipment
Electrical and Electronics
Ireps
Opening Date6 Feb 2025
Closing Date3 Mar 2025
Tender Amount₹ 3,38,37,171.42 
Notes
Download

AI Insights

Bid Capacity
... View More
The bid capacity required to bid is a minimum average annual contractual turnover of 3.383717142 crores or more, calculated using the formula: Minimum average annual contractual turnover = V/N or 'V' whichever is less, where V = Advertised value of the tender in crores of Rupees and N = Number of years prescribed for completion of work for which bids have been invited.
Technical Capacity
... View More
The bidder should have experience in works similar to the tendered work, specifically in signaling installation. They must have successfully completed or substantially completed any one of the following categories of work(s) during the last 07 years: (i) Three similar works each costing not less than 30% of the advertised value of the tender, (ii) Two similar works each costing not less than 40% of the advertised value of the tender, (iii) One similar work costing not less than 60% of the advertised value of the tender. In case of tender for composite works, the tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during the last 07 years: (i) Three similar works each costing not less than 30% of the advertised value of each component of the tender, (ii) Two similar works each costing not less than 40% of the advertised value of each component of the tender, (iii) One similar work each costing not less than 60% of the advertised value of each component of the tender. For substantially completed work, payment equal to or more than 90% of the present contract value has been made to the contractor. The bidder should submit certificates and testimonials regarding contracting experience for the type of job for which the tender is invited, along with a list of works carried out in the past. No specific percentage of similar works completed is mentioned for general requirements, but specific values and percentages are mentioned for the categories of work(s) mentioned above.

Costs

Summary

Replacement Of Worn Out Mechanical Lifting Barriers With Electrically Operated Lifting Barriers In D Route Over Firozpur Division.

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Supply of 3 Aspect colour light signal unit complete without holders, lamps, lenses and signal transformer as per RDSO Drg. No. SA-23002 A/M (Adv.) or latest and specification no. IRS:S- 26/64 Rev. 1 or latest. (Inspection: RITES)

20

19089

381798

... More
Supply of Key lock relay, type TMA 24V DC with 2F/2B contacts configuration with different wards combination as per RDSO spn. No. IRS:S-46, S-34 & S-23 and RDSO/SPN/219/2016 ver 1.0 with Amendment-1 or latest. Details of ward combination will be provided during execution of work. (Inspection: For bare relay -RDSO, for key lock housing- consignee)

-

-

5

... More
Supply of Relay plug in type, style AC LED, all aspect AC lamp proving relay unit with in built current transformer type slow to release neutral line relay 4F/4B contacts, front & back 6 contacts metal to carbon, shall be suitable for working in series with the 100 V AC, LED signal lamp rated at 15 W confirming to RDSO spec STS/E/ Relays/AC Lit LED signal/09-2002 Amdt 1, BRS:941A, IRS-S-34 & IRS-S-23/88 or latest with latest amendments as applicable. The interlocking code for this unit shall be ABDHK type. (Inspection: RDSO)

40

5294

211796

... More
Supply of apparatus case Large with 'E' type locks and key ward no. 42 and handle as per RDSO Drg. no. RDSO/S-11500. (Inspection: RITES)

72

18726

1348279.92

... More
Supply of ARA terminal blocks 25 mm center small M-6 terminal made of PBT as per RDSO drg. no. SA-23741-A (alt-4) & spec. no. IRS-S-75/2006 & RDSO/SPN/189/2004 Ver. 3.0 (Rev:2) or latest as applicable. (Inspection: RDSO)

7200

56

403200

... More
Supply of railway signalling cable copper conductor and wires with PVC insulated sheathed for indoor railway signalling of size 16/0.20 mm as per RDSO Spcn. no. IRS : S 76-89 amdt. 3 or latest purchased from RDSO approved vendors only. (Inspection: Consignee )

20

7008

140165.4

... More
Supply of 02 nos. electrical lifting barrier booms of 9.76 meters each as per DRG. RDSO/S-11600. The material will be as per RDSO Specn. No. RDSO/SPN /208/2012/Ver.2.0 and Amendment 1 or latest. (Inspection: RDSO)

36

27917

1005027.48

... More
Supply of apparatus case steel Medium with E type lock and key ward no. 42 and handle as per RDSO Drg.no. RDSO/S-11507 or latest. (Inspection: Consignee)

10

14614

146143.9

... More
Supply of AC/DC Clamp meter make Koico-3540 or similar with following electrical specifications: Resolution of 1mA on AC/DC A ranges, AC/DC A ranges 5000mA/50/100A, AC/DC 12 ranges V 50/300V, 500 ohm/5/50/500k ohm etc. The meter comprises of minimum additional facility of AC/DC voltage measurement, Resistance measurement, frequency measurement & continuity measurement, Continuity beeper, with One year warranty and backlight display facility. (Inspection: Visual inspection by RITES based on Guarantee certificate & Test certificate/ GC & TC).

40

18762

750480

... More
Supply of Relay AC immune, plug in type, style QNA1, DC neutral line 24V DC, 8F/8B 13 contacts, Front and back contacts metal to carbon with plug board, retaining clip and connectors conforming to BRS-931A, IRS S 60/78, IRS S 34/68 and IRS-S-23/88 or latest (as applicable). The interlocking code for this unit shall be ABDGH. (Inspection: RDSO)

180

3084

555148.8

... More
Fabrication & supply of domino type operating cum indication panel for way side station of exchangeable units of size 54X34 mm (Siemens panel size) and cover plates with tag blocks/terminals, wires, angle irons etc. depicting the yard layout with signals, points, track circuits, operating/emergency push buttons, counters, SMs key housed in steel metal cabinet as per approved 14 panel diagram and RDSO spec.no. RDSO/SPN/186/2004 Rev. 2.0 or latest if any. This also includes supply and fixing of acrylic sheet on panel. LEDs (24 VDC) to be provided as per direction of engineer. Panel shall be supplied with complete soldering. Size of panel should be such, so as to accommodate on additional line on either side. This includes 20% of extra panel indication LEDs of each color, 5% push buttons of each color, 5 extra dominos & 2 extra counters to be supplied by the contractor. (Inspection: RITES)

3312

613

2033369.28

... More
Supply of copper Power wire 1X16 sqmm. (Red/Black/Green in color as per requirement at site) conforming to IS 694/2010 or latest. (Inspection: Consignee)

2

170206

340413.4

... More
Boring & trenchless, cabling along with supply and insertion of Double walled corrugated HDPE ducts as per RDSO spec. no. RDSO/SPN/SPN/204/2011 ver.1.1 and amendment 1 or latest with 90mm outside dia. and 67mm minimum inside dia. in the bore for laying of signaling/telecom/power cables under the track/road. The following required coupling arrangement should also be supplied: 1. Suitable snap fit couplers with rubber O ring 2. Spacers 3. Tees 4. Bend 5. End cap etc. to be supplied along with the pipe. Work at site shall be inspected by Site engineer & DWC HDPE pipe and associated material to be inspected by RITES.

-

-

1

... More
Supply and installation of earth electrodes pipe of 3 mtrs length and 50 mm dia. pointed on lower end by tapering for a length of 150 mm and connecting with lightening arrester or signaling gears as per std. Practice. The item includes digging of pit in earth, 3 Mtrs. Deep and fixing earth electrode pipe in it. Earth pipe shall be buried in the ground to the length of 2.7 mtrs. after welding 6 SWG wire at lower end and fixing through nut and bolt at top. Casting of cement of Cement concrete enclosures as per drg. No. NR/S&T/CON/6.4/97 or latest if any. The soil treatment shall be 2 done as per std. practice. The item includes provision of earth lead wires/mild steel flat and soldering of lead wires. The other end of the earth wire/mild steel flat to be connected to block instrument mild steel flat, cable sheath of power equipment, apparatus case, relay racks, other equipments as per the instruction of Engineer at site & IRSEM. Complete materials such as earth electrodes as per drg. No. NR/S&T/CON/6.3/97, cement, wiring material, soldering material, mild steel flat, soldering of lead wires etc. to be supplied by the contractor. The earthing lead shall be mild steel flat of size 35mmX6mm. In case conductor is buried underground, it shall be protected from corrosion by application of suitable anti-corrosive paint. (Material inspection: RITES)

200

2680

536162

... More
Supply and laying of 2nd class bricks in the trench and laying as per drg. No. NR/S&T/CON/1.1/97-A and as per instructions of the site Engineer. (Bricks to be inspected by Consignee).

158400

5

814176

... More
Installation, testing & Commissioning of LC gates includes excavation & casting of foundation of 1:3:6 for pedestal and boom rest with contractor's own material including cement, 1 anchor bolts, erection of lifting barriers assembly right hand/left hand boom complete on the pedestal, fixing of boom support for lifting barrier boom, installation of boom locking devices & control panel, flasher, warning bell with associated warning, fixing and wiring of Key chain interlocking along with electric lever locks. This includes power supply connections, wiring and other outdoor Works etc. All materials required for installation & wiring shall be supplied by the contractor. (Inspection: Consignee)

36

82123

2956440.24

... More
Fixing of CLS surface base, bolting on the foundation. Erection of CLS post with signal unit on the top or on an off-set bracket and fitting ladder and guard to the post at the top. Concreting ladder base and embedded into the ground with supporting bracket in the middle, blanking of the ladder for a distance of 1 feet between the height 6' 9" and 7' 9" from the rail level by MS angle and MS sheet 6mm thick wherever required. This includes provision of wooden (SAL) cross arm 1 mtr x 1 mtr for CLS unit prior to the commissioning, fixing of LED aspect, current regulator and hoods of CLS 2 unit, terminating cables, wiring the CLS unit and focusing the signal. Elevation & distance of foundation from track shall be in accordance with schedule of dimension for Indian Railways and as per NR practice. All items for the above Works except Signal unit, LED signal, Signal post, Base and Ladder shall be supplied by the contractor including but not limited to the following: i) "U" bolt for offset brackets, ii) Wooden cross arm 1 mtr. x 1 mtr., iii) MS angle and MS sheet for blanking of ladder, iv) Supply and fixing of signal number plate (retro reflective) with complete fittings as per standard Railway practice. v) Wire mesh guard, lock for unit if required, nuts, bolts etc. for the following: (a) Installation, erection, wiring of 2/3 aspect color light signal. N Inspection: Site Engineer.

20

2526

50535.6

... More
Casting, concreting and curing of foundation for main signal as per Drg. no. 3 NR/S&T/CON/2.1/97 or latest. All material such as anchor bolts, cement & aggregate to be supplied by contractor. All concrete work must be ratio of cement, coarse sand and aggregate 1:3:6.(Inspection: Site Engineer)

20

10116

202320.8

... More
Casting, concreting and curing of foundation and erection of App. Cases large as per 4 drg. No. NR/S&T/CON/2.7/97 or latest. All materials such as cement, sand, aggregate and anchor bolts shall be supplied by the contractor. App. Case single will be supplied by railways. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination. (Inspection: Site Engineer)

72

4285

308552.4

... More
Preparation & fixing of Bakelite hylum sheet 910 x 800 x 6mm and teak wooden shelf 900mm x 450mm x 25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mm x 25mm x 3mm. Angle iron frame will be fixed in location boxes secured by nuts & bolts. Fixing of fuses, ARA terminal shelf type 'Q' series relays and other type relays on square bars fixing and jamming of cables with 2 inch thick salwood 5 plank provided at the bottom. This will include opening, pasting and jamming armour of each cable in the hole drilled separately for each cable through the salwood plank & all cable entry points on location boxes, location huts, JB's relay room/battery room to be closed with suitable masonry works covered with sand and plastering. Description for terminal drawing of circuits, inside app. Case. Painting from out side as well inside with red oxide and aluminum paint is covered separately. Size of lettering will be 100mm or as per instructions of Engineer at site. All materials including hard wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS specn., non deteriorating type HRC fuses, bases, nuts and bolts and other items shall be supplied by the contractor. Relays, ARA terminals only shall be supplied by the railways. Preparation of Apparatus Case single involving wiring of relays. (Inspection: Site Engineer)

72

5372

386825.04

... More
Wiring of relays in relay room/relay huts as per approved wiring diagrams. All material required including indoor cables and wires of 1x1, 1x0.6, 3/0.29, 16/0.2, 40x0.6, 40x1, 60x0.6, 60x1 dia. of copper conductor as per NR practice conforming to IRS specifications, resistance and 6 condensers are to be supplied by the contractor. This also includes wiring from CT rack to tag block, tag block to relays & wiring of fuse etc. required in connection with relay room /relay hut wiring and soldering, dressing, bunching, lacing, fixing of relay bases etc. and provision of LED indication of vital relays in relay room and provision of potential free contacts for relays on tag block for data logger as per instruction of site Engineer. This also includes dressing, bunching, lacing and fixing of relay bases. Indoor cable/wires should be pre-inspected by Consignee. (Inspection: Site Engineer)

400

383

153240

... More
Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No. NR/S&T/CON/1.1/97-A or latest so as not to form a drain 0.3 Mtrs. Wide & 1 Mtr. 7 Deep on both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable plan. It also includes clearance of routes of trees & bushes. Lesser depth due to site conditions shall be paid proportionately after obtaining prior approval from not below than JAG officer.(Inspection: Site Engineer)

19800

54

1070190

... More
Laying of signaling/telecom/power cables by unwinding cables from drums of different 8 sizes as per drg. no. NR/S&T/CON/1.1/97 and as per cable route plan approved by the railways. Meggering of cable before and after its laying of all types of cables. Meggering to be done for each drum separately. Meggering sheets to be supplied and filled up by contractor and submitted to Railways. (Inspection: Site engineer)

54000

6

325620

... More
Installation of KLCR & its box in location boxes/gate lodges, supply & installation heavy 9 duty push button, LED indicator on MS sheet of 4.5 mm thick inside location box/gate lodges for crank handle locking. The work includes fixing & wiring of magneto telephones, wiring of relays, push buttons and termination of tail cable as per instruction of site engineer. All material except KLCR & its box and magneto telephone is to be supplied by the contractor. (Inspection: Site Engineer)

36

8571

308579.76

... More
Earth work around location boxes, signals and other signaling structures etc. wherever necessary including 50 m lead and 1.5 m lift by excavation. The lead be measured from the center of 10 gravity of excavation to the center of filling and the lift, from means ground level. The earth shall be rammed including breaking of clods, levelling and dressing. The earth work around the location/junction boxes shall be up to the plaster level and for width sufficient for the maintainer to attend the box both from front & back side. (Inspection: Site Engineer)

20

117

2344.6

... More
Concreting unscheduled items in concrete of 1:3:6 ratio in cement, coarse sand and aggregate 25mm at different places in the yard and plastering top in fine plaster of 1:4 cement, sand 11 ratio. It also includes excavation of earth as required at site and as per instruction of site engineer. The volume in cubic meters shall include the volume occupied by any CI foundation, trestle, MS angle or flat or GI pipe required to be embedded in the casting. cement, coarse sand and aggregate 25mm are to be supplied by the contractor. (Inspection: Site Engineer)

18

2397

43148.16

... More
Bricks work with well burnt bricks in foundation and plinths with cement and sand mixture of 1:4 ratio. All material is to be supplied by the contractor. (Inspection: Site Engineer)

18

3019

54357.84

... More
Casting, concreting and curing of foundation and erection of App. Cases (Single) as per 13 drg. No. NR/S&T/CON/2.7/97. All materials such as cement, sand, aggregate and anchor bolts shall besupplied by the contractor. App. Case single will be supplied by railways. Contractor is required to execute all type of repair works of foundations if required during inserting the cable for termination. (Inspection: Site Engineer)

10

4066

40666.9

... More
Preparation of App. Case half not involving wiring of relays which includes following- (i)Preparation and fixing of Bakelite hylum sheet 450x800x6mm and teak wooden shelf 450x450x25mm duly fixed by angle iron piece of different size inside all the app. Cases. Hylum board shall be fixed on an angle iron frame of 25mm/25mm/3mm. Angle iron frame will be fixed in location box secured by nuts & bolts. (ii)Fixing of fuse ARA terminal, shelf type Q series relays and other type of relays on square bars, fixing and jamming of cable with 2 inch thick salwood plank provided at the 14 bottom. This will include opening, twisting and jamming armor of each cable in the hole drilled separately for each cable through the salwood plank and of cable entry points on location boxes, location nuts JB's relays room battery/room to be closed with suitable masonry work covered with sand & plastering. (iii)Wiring description for terminal, drawing of circuits inside app. Case. Painting from outside as well inside with RED oxide aluminum paint is covered separately. Size of lettering as per instructions of Engr. at site. (iv)All material including teak wood shelf, hylum board, salwood plank, angle iron square bar, wire and wiring material as per the IRS spec. Non deteriorating type HRC fuses and bases nuts and bolts and other items shall be supply by the contractor. Relays, ARA terminals only shall be supplied by the railways. (Inspection: Site Engineer)

10

3368

33681.5



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.