Northern Railway Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 1,94,100Document Cost
Refer DocumentsTender Fee
Refer Documents
Summary
Electrical Work In C/w Upgradation / Improvement Of Jandiala, Butari, Patti & Bhagtanwala Goods Shed
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
251-Elect-T-35-2024-25-FEROZPUR DIVISION-ELECTRICAL/NORTHERN RLYTender No
251-Elect-T-35-2024-25Tender Authority
Northern Railway ViewPurchaser Address
-Website
http://ireps.gov.in
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Wiring for 5 pin 5 Amps plug points 5 Amps capacity with 2x1.5 sq.mm FRLS PVC insulated 04 unsheathed multistranded copper conductor s/core cable in recessed PVC conduit pipe 25 mm dia including provision of 3 pin 5 Amps socket outlet with 5 Amps piano type switches and earthing of 3rd pin and MS box with 14 SWG GI wire as required at site.
40
94
3792.4
Wiring for 3 pin 15 Amps plug points 15 Amps capacity with 2x2.5 sq.mm FRLS PVC insulated 05 unsheathed multistranded copper conductor s/core cable in recessed PVC conduit pipe 25 mm dia including provision of 3 pin 15 Amps socket outlet with 15 Amps piano type switches and earthing of 3rd pin and MS box with 14 SWG GI wire as required at site.
35
179
6286.7
Supply of Piano Type switch 5A (1-way) as per IS 4949 -1968(latest version) /Bell push as per IS 4794 ( Part 2 ) -1986(latest version)/flush type socket outlet as per IS 1293 -1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per Tech. Specifications.
470
16
7881.9
Wiring for light points with supply and laying of FRLS PVC insulated multistranded copper conductor cable 1100 Volt 1.5 Sq.mm multi stranded confirming to IS-694 latest in the existing PVC pipe.
18200
14
255164
Supply, laying, fixing,testing and commissioning of 2.5sq mm FRLS, PVC insulated multistranded 08 copper conductor single core cable 1100 Voltsconfirming to IS-694(latest version),make Finolex,Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as perTech Spec-I attached, IS & IErules.
9000
18
169740
Supply, laying, fixing,testing and commissioning of 4 sq mm FRLS, PVC insulated multistranded 09 copper conductor single core cable 1100 Voltsconfirming to IS-694(latest version),make Finolex,Havells, Polycab, KEI or equivalent in the existing PVC conduit for wiring of point wiring/circuit wiring/sub main/main as perTech Spec-I attached, IS & IErules.
5500
27
152240
Supply and recessing/fixing of 25mm (Medium) PVC conduit pipe conforming to IS 9537/Pt.III/1983 or Latest Version with accessories,junction box, etc including making chase, plastering/clamping etc as per technical specifications.
4000
39
156400
"Supply, fixing, testing and commissioning of LED light luminaries, having system wattage 1x > 18w 11 (Max.), LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be of make Phillips, Bajaj,Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121- Elect/PS/2018 (Rev- '3'), & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') or latest"
1100
557
613250
Supply, fixing,testing and commissioning of 3-pin ceiling rose 5 Amp capacity on existing MS/PVC conduit junction boxes/casing caping Anchor, Cona, Kinjal, SSK or equivalent as per IS, IE rules and site requirement.
1100
12
13959
Supply, fixing, testing and commissioning of energy efficient 230V, 50Hz a c ceiling fan size of 13 1200mm sweep having wattage of 28W, range of voltage operation at various speed - 120 to 260V AC with 5 step speed control electronic regulator, copper winding complete as per IS : 374 - 1979 or laterst, IE rule & site requirement. Make Bajaj, Usha, Havells, Crompton, Orient or equivalent.
30
3088
92669.1
Supply, fixing,testing and commissioning of 380mm sweep, 1400 rpm (approx) propeller type exhaust fan complete as per IS, IE rule & site requirement.Make Usha, Orient,Bajaj or equivalent
16
3091
49460.48
Supply, erection, testing and commissioning of the following Double door wall mounted Pre- fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCCB 4Pole 63 A 35 KA B/C - 1 No. (ii). Outgoing MCB 6 to 32 A. SP 10 KA B/C (4 Nos. On each Phase) - 12 Nos.
4
14383
57534.56
Supply, erection, testing and commissioning of the following Double door wall mounted Pre- fabricated L.T. Distribution Boards of approved make, as per explanatory note & comprising; (i) Incoming MCB 40 A DP 10 KA B/C - 1 No. (ii) Outgoing MCB 6 to 32 A. SP 10 KA B/C - 4 Nos.
4
1465
5861.48
Supply & erection of 103 mm Inner dia Double Walled Corrugated pipe in ground under Railway track/road as required and as per explanatory note.
1800
327
590076
S.I.T.C of Self contained drinking water cooler capacity 150 LTR with Non CFC refrigerant ) energy efficient compressor cooling capacity LTR/HR 150, storage type , confirming to IS-1475-1 PART 1, of 2001 or latest make blue star, voltas or similar.
3
52822
158468.04
Supply, Installation,Testing & Commissioning of single phase RCBO of 32 Amps capacity,30mA sensitivity with Metal enclosure.
3
2552
7656.12
Transportation, Laying, underground/road/Railway track, recessing in platform /wall along with Rly. 20 Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured, aluminium conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of Upto 25 sq.mm
1000
61
61410
Transportation, Laying, underground/road/Railway track, recessing in platform /wall along with Rly. 21 Track/in laid RCC/GI pipe as required 1.1 KV grade LT XLPE insulated armoured, aluminium conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks, provision of cable route marker as per Tech. Specification including end terminations with Aluminium Clamping socket/lugs, testing and commissioning of Above 25 sq.mm
8800
58
513128
Laying of cable under ground through 160mm dia HDPE pipe by MicroTunneling cable laying method including supply and jointing of HDPE pipe.
135
1775
239665.5
Design, manufacturing of floor mounted MS feeder post made of MS sheet 16 SWG Die pressed of size 550mm x 450mm x 275mm deep complete with Aluminium bus bars four Nos. having cable glands 2 Nos. duly grouted with cement concrete ratio 1:2:4 duly earthed with earthing terminals.
44
3639
160123.48
Earthing arrangement by providing earth electrode of GI pipe 50 mm dia (B class) 4.5 meter long 24 with flange including 6 SWG GI earth wire from earth pipe to connecting point on switch board to distribution board/pole etc. as per site requirement including masonry enclosure as per Tech specification at annexure 'A' relevant ISS & IE rules and site requirements. A suitable CI/MS/RCC cover as approved by Rly . Representative, cover with locking arrangement shall be provided.
61
2439
148820.48
Supply & recessing/fixing on surface 6 SWG GI wire for loop earthing as required as mentioned in explanatory note.
222
9
2017.98
Supply, laying and connection with GI Strip GI 25x5 mm (galvanized) conforming to relevant IS and as per IS 3043/1987(or Latest Version) 300mm deep in ground/recessing in flooras required.
237
70
16642.14
Supply, testing, commissioning of 16 meter high mast system suitable for 9Nos. LED flood light luminaries (Min.150 Watt) with the help of suitable equipment including accessories control panel for high mast system. Each high mast shall also have one twin dome aviation obstruction light with 2 nos. LED lamp equivalent to BJAOL -2. Make BAJAJ, Osram, PHILIPS, GE. B10Note-Accessories includes 3 point suspension head frame, steel wire rope of suitable dia, double drum winch, galvanized lantern carriage & other arrangement for each high 27 mast shall have one Fedder Pillar box as per specification. Control panel includes the control circuit for lowering/raising operation of mast integral detachable power tool with motor including torque limiter time switch and lighting final including lines required for switching.Design / casting of shallow foundation of mast /panel shall be with M-20 concrete. Considering safe soil bearing capacity at site as 10 T/sq mtrs at 2 mt. depths.Foundation both,nuts, washes, anchor plates, templates should be made of Spl. Steel. Any alteration/modification shall be done as per site/tech. specification requirement to the satisfaction of Rly.Representative at the cost of firm. The tower shall be as per Tech. Specification at Annexure , IS, IE rules and site requirement.
16
240998
3855970.88
Supply, installation,testing and commissioning of 150 Watt LED based flood light fitting, operating 28 voltage single phase 230V AC, 50Hz complete with led lamp & all mounting arrangement, accessories & flexible copper wire for connetion as per ISS/IR rules & as per CEE/NR Specification No. CEE/NR/121-Elect/PS/2018 (Rev.03) dated 28.06.2018 & CEE/NR/121-Elect/PS /2019 (Rev.4) dated 04.11.2019 respectively or latest
144
13345
1921802.4
Supply, fixing, testing & commissioning of astronomical timer based control panel for High Mast tower lighting suitable for 25A 4 P. contactor as per model No. Alpha Rex3 D21, 1 channel Cat Part 412654 of Legrand or equivalent.
16
8033
128535.04
Providing SH rail post 1.5/ 2.5 mtrs. Long for safety of high mast. Work includes cutting of 50 or60 30 or 75 or 90 lbs capacity rails in pieces of desired length (1.5/2.5 mtrs.),digging of pit and erection of rail pole (Rails will be supplied by railway and is to be collected by contractor from concerned SSE). The rail pole shall be erected over a cement concrete bed (1:3:6) of 15cm thickness and back filling of pit with excavated earth soil. The depth ofthe pit shall be 0.5 mtrs.or as directed by Site Engineer. These rail poles should be grouted properly.
64
1053
67402.24
Excavation of cable trench by cutting/breaking station platform concrete/pucca floor digging 400 mm deep and then refilling after laying of cable as per IS 1255:1983 and technical specification enclosed on a cushion of sand 100mm below and providing protective bricks as per drawing and soil and ramming, leveling and repairing and finishing the said portion of platform with 1:2:4 cement concrete mixture100 mm deep from top. I)Trench width 300mm wide for laying up to 3 cables with 9 protective bricks per meter.
300
390
117165
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements