Military Engineer Services Tender

... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 May 2022
Closing Date20 Jul 2022
Tender Amount₹ 88,56,009 
This is an estimated amount, exact amount may vary.
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Lumpsum price worked out by the contractor for “ADDITION / ALTERATION OF BUILDING” as listed in Schedule ‘A’ Part III.

1

-

952149.91

... More
Lumpsum price worked out by the contractor for “INTERNAL ELECRIC SUPPLY WORKS” as listed in Schedule ‘A’ Part IV.

1

-

126114.4

... More
Lumpsum price worked out by the contractor for “FLAME PROOF LIGHT” as listed in Schedule ‘A’ Part - V.

1

-

270765.33

... More
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY WORKS” as listed in Schedule ‘A’ Part VI.

1

-

179630.58

... More
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIFICATION WORKS” as listed in Schedule ‘A’ Part VII.

1

-

373041.8

... More
Lumpsum price worked out by the contractor for “CHEMICAL EARTHING” as listed in Schedule ‘A’ Part VIII.

1

-

417424.3

... More
Lumpsum price worked out by the contractor for “LIGHTENING PROTECTION” as listed in Schedule ‘A’ Part IX.

1

-

406754.4

... More
SCHEDULE `A' PART - X (MISLANEOUS ITEMS) : is not prepriced by the MES and prescribed rates indicates 0.0 under column 6 signified with fact only.

-

-

-

... More
INTERNAL ELECRIC SUPPLY WORKS

-

-

-

... More
Supply and fixing of integral driver 30 Watt LED Bldg security light with a nominal system lumen output of 3000 lumens and a minimum system efficeny of 100 lumen/Watt. The luminaire shall have rated system lifetime of 50000 burnings hours at L70. The luminaire should have cool white colour temperature (CC5000K) and a CRI70. The luminaire shall meet IP66 rating with THD 20% & PF 0.9. The luminaire housing should be made of pressure die cast aluminium. The total power consumption should not exceed 25W (including driver). Make:- Haells or equivalent in Philips, GE.

3

-

-

... More
EXTERNAL WATER SUPPLY WORKS

-

-

-

... More
Labour for Disconnecting the existing 100/80 mm GI pipe ,suction and delivery end of any type from the existing pipe in under ground and supply and fixing with new pipes of various material and sizes of pipe given in schedule , all as specified and directed. Note The cost of included for fitting like , bends, Tee, Union, Socket, Mechanical Joint, Nipple etc of any size required to connect fro existing pipe to new proposed pipe. The cost of also included excavation required to cutting of pipe.

1

-

-

... More
Material and labour for construction of valve pit chambers of size 1.2m X 1.20mX 1.2mtr (internal dimensions) as under provided with 10 cm thick PCC 1:4:8 type D2 as in foundation over 15 cm thick hard core, 23 cm thick brick walls built in cement mortar 1:4, 15 mm thick internal plaster including top of floor, externally upto 150 mm below GL in CM 1:3 finish even and smooth without using extra cement, 4 mm thick MS sheet cover with 40 x 40 x 6 mm MS angle frame fixed in PCC 1:2:4 type B1 coping with 25 x 6 mm flat iron hold fasts, hinges, handles, locking arrangements and applying 2 coats of synthetic enamel paint over acoat of red oxide primer to all steel surfaces and 3 coats of white wash to internal surfaces of chamber including excavation and earth work in any type of soil and removing of surplus soil to a distance not exceeding 50 m complete all as specified and directed.

1

-

-

... More
S & F rotational moulded polyethylene water storage tanks ISI Mark of capacity 5000 Ltrs 3 layers (cylinderical vertical with closed top threaded type white colour ) hoisted and fixed in position including inlet and out let connection all as specified and directed by EIC. Make Plasto, Sintex, vectus)Stand by for Cooling tower. Note : - The cost shall be included for suitable foundation for water storage tank of size 2 m x 2m x 1.2m height.

1

-

-

... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.

10

-

-

... More
EXTERNAL ELECTRIFICATION WORKS

-

-

-

... More
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure. All as specified and as directed By Engr-In-Charge.

10

-

-

... More
Supply fix and test Cable tray perforated of 150 mm width, 50 mm height and of 14 Gauge powder coated including coupler plate, bends, angle iron 40x 40x 5 mm size at suitable distance for support with wall etc , complete all as specified and directed.

90

-

-

... More
Supply and installation LT Electric control panel, cubical type, for out door use floor mounted made out of CRCA outer sheet of 3.15 mm thick and inner sheet of 2 mm thick and angle iron legs of size 40mmx40mmx5mm having front and rear open hinged doors with front openable shutters for each MCCB with spreader & extended rotary handle having hinges on one side and locating arrangements with screws type on other sides completely, 415 volts, 50 C/S 4 wire system, with cable entry provision, with suitable lugs gland, voltmeter , Ammeter,CTs and phase indicator complete, duly painted with two coats of stove enameled powder coated paint over a coat of red oxide primer and 3 mm thick FRP Coating complete and nut,bolt,washers for connection of cable, including necessary PCC work of height 45 cm from ground level and white washing to the platform all as specified and equipped with the following items :- Make of MCCB : Legrand, Siemens, Schneider. INCOMER (I) MCCB, 4pole, 200 Amps , rupturing capacity 35 KA magnetic thermal release - 01 Nos.C&S OUTGOING MCCB 63 Amp 4 -03 Nos (II) Volt meter, digital type 0-500 volts with selector switch - 01No. (III) Amp meter digital type 0-250 amps, CT operated with CTs and selector - 01 set Note: The cost shall be included PCC 1:3:6 required to installation of Panel

1

-

-

... More
AIR CONDITIONING WORKS

-

-

-

... More
Supply , install , commissioning and testing of Water Cooled Scroll Chillers, with single / multi compressors, comprising of Hermetic/Semi - Hermetic Compressors,with Shell and Tube Condenser DX Evaporator Chiller,suitable for operation on R-134A/ R - 407 C/R 410A refrigerants ,and of nominal capacity of minimum 10 TR at chilled water inlet/ outlet temperature of 53.6 deg.F / 44.6 deg.F with chilled water circulation rate of 110 LPM(29 GPM) (nominal) and condenser water inlet /outlet temperature of 90deg.F/ 97.5deg.F with circulation rate of 133LPM(35 GPM)(nominal) The unit is complete with safety switch control for compressor insulation for chiller all mounted on a steel frame and suitable for 400v/50Hz /3 pole supply. The scope of work shall also include Lifting, shifting & positioning of chiller at location shown on drawing or as specified by Engineer-in-charge. . (2 working and 1 stand by) Refrigerant - R-134A/ R - 407 C/R 410A Evaporator fouling factor -0.0001 (British Units) Condenser fouling factor-0.00025 (British Units) COP-4.2 Note: Next higher capacity of water cooled scroll chillers to be provided if exact capacity is not available with in the cost quoted.

3

-

-

... More
Supply, installation,commissioning andtesting of induced draft top discharge counterflow type FRP Cooling Tower(Rectangular/Roundbottle shape) with FRP body and base, the cooling tower is with water spray headers, cooling tower fills with adequate quantity of cellulose PVC fibres in plastic form as per OEM recommendation, fan with motor, supporting baseframes, FRP basin with integral louvers and drift eliminators complete with hot water basin either fitted with spray nozzles or having self rotating sprinklers, 1 no axial flow type fan-direct driven or driven through reduction gear box with TEFC induction motor withgood efficiency , suction screen, make-up quick fill arrangement, overflow and drain connections and suitable inspection ladder to access arrangement for cooling tower interior, Range: 4.5 Deg. C/ 7.5 Deg. F Condenser water inlet/outlet temp-90-97 Deg F Wet Bulb Approach: 2.78 Deg. C/ 5 Deg. F Capacity of cooling tower-30TR

1

-

-

... More
Supply, installation, testing and commissioning of electrical Hot water Generator of vertical construction equipped with sufficient number of flanges and electric emersion heaters. The pressure vessel shall be constructed as per ASME standards and insulated on all sides with 50 mm thick fiberglass with 0.6mm Aluminium cladding as per specifications.The hot water generator shall be equipped with all automatic and safety controls such as manual reset, high temperature water cutout, step controller, on/off switch, pilot light,low water cut off and other controls as per manufacturers recommendations.All basic controls and terminals shall be located in an integral control cabinet factory wired and tested. The hot water generator shall be suitable for 415 volts, 50 Hz, 3phase power supply.The entire hot water generator shall be factory assembled and tested. 45 kW Hot Water Generator as described above Water ‘in’ temperature‐ 45 Deg C Water ‘out’ temperature‐ 50 Deg C

1

-

-

... More
Supplying, erection, testing and commissioning of chilled water centrifugal pump set capable of delivering 59GPM /223LPM of water against a head of 20mtr. Each pump shall comprise of following as required as per specifications. and as located shown on drawing.(1w+1s) End pump shall be monoblock type and top discharge complete with 5HP sq cage induction motor with mechanical seal bronze impeller suitable for 400/3ph/50hz supply.the motor pump shall be insulated with pipe line material.

2

-

-

... More
Supplying, erection, testing and commissioning of condenser water centrifugal pump set capable of delivering 88GPM of water against a head of 15mtr. Each pump shall comprise of following as required as per specifications. and as located shown on drawing.(1w+1s) End pump shall be monoblock type and top discharge complete with 3HP sq cage induction motor with mechanical seal bronze impeller suitable for 400/3ph/50hz supply.

2

-

-

... More
Supply installation, Testing & Commissioning of ultrasonic Humidifier, CAP 9 LPH complete with stainless steel tank with float valve, water makeup, overflow and drain connections. The transducer shall be interlocked with float switch, supplied with humidifier and humidistate with necessary supports by MS structural steel II required, hangers, clamp supports from walls, floors and ceiling with painting with one coat of primer and two coat of paint to supports of MS work,complete as required and as per specifications.

2

-

-

... More
Supply, install,commis-sioning and testing of Flame proof Double Skin suitable to install in open to air on ground or hanging in ceiling or installed in Iron channel . Mounted draw through type Air Handling Unit of 6000cfm capacity.the unit shall be fabricated with extruded aluminium sections and with panel with 0.8 mm thick pre plastisized /precoated galvanized steel sheet on outside and 0.8 mm thick plain galvanised sheet on inside with 25mm Pu insulation 36kg/cu.m.coil section with 4 row deep cooling coil and 2 row deep heating coil. blower section with forward curved blower v-belt drive with flame proof drive motor suitable for 400A/3phase/50Hz supply. filter section with pre filter 50mm thick having a filteration efficiency of 10 micron and fine filter for 5 micron efficiency ,drain pan of 18 G stainless steel sheet with insulation. VFD operated motor (flame-proof), and panel suitable for operation at 415 ± 10% volts, 50 Hz, 3 phase, A.C supply complete with drain connections, stainless steel (20G) drain pan, the engineer-in- charge including testing on completion, ement, flexible duct connector etc., complete as per following:- (a) Fine filter should be located after the fan in the direction of airflow. (b) The AHU should have space for humidifier. VFD panel with VFD (quantified separately), necessary control arrangement to switch off the fan in case of fire, indicating lamp & all safety precautions in a flame-proof powder coated Gl enclosure with necessary power and control cable as required. Note: Suitable arrangement of platform and connected accessories for ceiling mounting AHU as per OEM instructions. The fan outlet velocity shall be limited to 9.5 MPS maximum and face velocity across filter shall be limited to 152 MPM maximum. The capacity of AHU unit shall as per specification. Floor Mounted AHU:6000 CFM at 50 mm static pressure (16 Tr), 4 Row Deep Coil, Motor-3 HP 2 Row Deep hot Water coil for winter heating Capacity of hot water coil -42 kw Note-All controls in air stream are interlocked with blower fan outlet /with auxiliary contact proposed on fan motor , the thermo state are operable to maintain desire condition.

1

-

-

... More
Supply installation, Testing & Commissioning of pan type Humidifier 4.5 KW capacity made from SS304 sheet Tubular heating elements made out of seamless copper tube duly chrome plated of required rating insulated with 25 mm thik fibre glass wool (density 32 kg per cubic metre) and cladded with 0.5mm GI sheet, water makeup, drain water overflow/quick fill connection and steam outlet nozzle, float valve, safety thermostate, control panel etc as required.

1

-

-

... More
Supply and lay MS Pipes heavy grade as per IS 3589(1981) thickness of pipe shall be 4.8 mm minimum with all fittings laid in floors or fixed to walls and ceilings (with necessary clamps, vibration isolators and fittings ) complete of following sizes :-

-

-

-

... More
50 mm dia

75

-

-

... More
65 mm dia

50

-

-

... More
Supply, laying and fixing of following nominal sizes of chiller / hot water piping insulation (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with 25mm thick closed cell class 'O' Nitrile Rubber elastomeric insulation of density 40-55 Kg per cubic metre, thermal conductivity of 0.037 W/mK at 20 degree celcius mean temp and minimum water diffusion resistance of 700 using manufacturer's recommended 'rubber-based adhesive in a blend of solvents. Nitrile rubber will be covered with the three layered aluminium cladding thickness of 1 mm and of metallic finish having aluminium as an intermediate layer and UV protection, as per manufacturer instructions, complete all as directed and specified.

-

-

-

... More
50 mm dia

75

-

-

... More
65 mm dia

50

-

-

... More
Condenser Water pipe Supply and lay MS Pipes heavy grade as per IS 3589(1981) thickness of pipe shall be 4.8 mm minimum with all fittings laid in floors or fixed to walls and ceilings (with necessary clamps, vibration isolators and fittings) complete of following sizes :-

-

-

-

... More
50 mm dia

10

-

-

... More
65 mm dia

30

-

-

... More
Supply, installation, testing and commissioning of following sizes PN-10 butterfly valves insulated in position complete with flanges,bolts, nuts gaskets etc. and conforming to specification complete of following sizes :-

-

-

-

... More
40 mm dia

3

-

-

... More
50 mm dia

21

-

-

... More
65 mm dia

4

-

-

... More
Supply, installation, testing and commissioning of following sizes ball valves insulated in position complete with flanges,bolts, nuts gaskets etc. and conforming to specification complete of following sizes :-

-

-

-

... More
25 mm dia

1

-

-

... More
32 mm dia

8

-

-

... More
Supply, Installation, testing and commissioning of motorised 3 way modulating insulated Control valves complete with electrical actuator, 50 mm dia, heavy duty PN 10 cast iron body with nylon coated S.G. iron disk, water sealant lining, stainless steel shaft, control lever with thermostat, control wiring, accessories if any like transformer etc.. Insulation shall be as per the connected chilled water piping.

1

-

-

... More
Supply, installation, testing and commissioning of following sizes PN-10 non return insulated valves in position complete with all requirement. and conforming to specification complete of following sizes :-

-

-

-

... More
32 mm dia

2

-

-

... More
50 mm dia

2

-

-

... More
65 mm dia

2

-

-

... More
Providing and fixing expansion bellows with control rods/ Spacer in pipe connections to equipment of the following sizes:

-

-

-

... More
32 mm dia

4

-

-

... More
50 mm dia

4

-

-

... More
65 mm dia

4

-

-

... More
Supply, installation, testing and commissioning of OEM recommendation sizes pressure gauges in the chilled water lines with gate valves conforming to technical specifications.

25

-

-

... More
S & F Industrial type mercury in glass industrial type thermometers with gun- metal/brass conduction isolating valve complete with all accessories as required.

12

-

-

... More
Supply, installation, testing and commissioning of flowswich in the chilled water lines conforming to specification.

6

-

-

... More
Supply installation testing and commissioning of one soft makeup water tank for purpose of cooling set makeup water pvc tank of 5000 ltrs. capacity ,associated Gi piping network with required quick fill valve ,overflow connection and valves .the price shall include staging of tank on a masonary /steel frame work of 2mx2mx1.2m(H) etc as per site requirement.

1

-

-

... More
Supply, Installing, Testing and commissioning of the following capacities PVC open Expansion tank with full XLPE foam insulated The tank shall be designed to absorb the expansion forces of heating/cooling system water while maintaining proper system pressurization under varying operating conditions. The system should include PRV , Airvent /isolation valve also. And complete as per technical specification.

-

-

-

... More
chilled water expansion tank Capacity 250 ltr

1

-

-

... More
Hot water expansion tank Capacity 50 ltr

1

-

-

... More
12 mm thick xlpe insulation on tank

10

-

-

... More
MS angle fram work /stand for chiller expansion tank including masonary /Rcc work such as cutting filling /finishing as per site requirement.

1

-

-

... More
MS angle fram work /stand for make up tank including masonary /Rcc work such as cutting filling /finishing as per site requirement.

1

-

-

... More
Civil masonary/RCC works such as foundation/ platform for equipment ,making opening for duct ,piping, cutting false ceiling for grills and frames etc as required as per site.

1

-

-

... More
Condensate Drain pipe Supply, Installation, Testing and Commissioning of PVC drain piping, complete High density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.with fittings, supports as per specifications and insulated with 6 mm thick closed cell polyethylene insulation as per specifications and drawings of following sizes :-

-

-

-

... More
40 mm dia

10

-

-

... More
32 mm dia

10

-

-

... More
Make up water GI pipe 25 mm dia for cooling tower ,humidification tank .Pipe laid on floor or fixed to wall as required.

20

-

-

... More
Air Distribution System ducting Supply, fabrication, installation and testing of GSS ducting complete with flanges including necessary supporting arrangement with flexible connection in accordance with the approved shop drawings and as per the specifications of following sizes :-

-

-

-

... More
24 G (0.63 mm)(0-750mm)

55

-

-

... More
22 G (0.8 mm) (751-1500mm)

66

-

-

... More
20 G (1.0 mm) (1501-2250mm)

12

-

-

... More
Grilles/Diffuser Supplying, installing & testing of Powder coated Extruded aluminum supply air grilles with volume control damper. All grilles shall be Single louvered complete as per specification & drawings.

1.2

-

-

... More
Supplying, installing & testing of Powder coated Extruded aluminum return/exhaust air grilles without volume control damper. All grilles shall be Single louvered complete as per specification & drawings.

0.8

-

-

... More
Acoustic Lining of Ducts Supplying, installing & testing of ducts acoustic liningas per the specifications.The Acoustic lining material Open Cell Engineered Nitrile rubber for Acoustics , of Class-1 , Density 140-180Kg / m3, UL94 approved(HBF, HF 1 & HF 2) in accordance to UL 94,1996.Thermal conductivity of 0.047 W / ( M*K), Air Erosion Resistance test Confirming to ASTM Standard C 1071-05 (section 12.7). For application use low voc Adhesive. thickness 15 mm thick as per specification. [ for duct linear=15mm thk]

30

-

-

... More
Thermal Insulation on Duct Supplying, installing of external thermal insulation on ducts with closed cell Nitrile Rubber Insulation 25 mm thick as per ASTM G797 standard Class “O” IMO A 653 (16), FM Global & UL 94 approved,density 40-55kg /m3. Temperature of -50 to 116 Deg C and Thermal conductivity of 0.036 W / m Deg K @ 0 deg C. water vapour permeability as per EN12086 (DIN 52615) , Moisture Resistance Factor = 7000. And coated with 2 coats of protective coating for exposed/external applications.For application use Low voc Adhesive K414 of 25 mm thick & complete as per specifications.

133

-

-

... More
Fresh Air Louvers Supplying, installing and testing of Fresh Air inlet louvers with volume control damper & bird screen in accordance with approved shop drawings and specifications.Aluminium extruded fresh air louver with VCD & Bird screen and filter

0.5

-

-

... More
Canvas connection Supplying, fabricating, installing and testing of double canvas flexible connection for constructed of standard material as per the drawings/ specifications.

2

-

-

... More
Fire Damper Supplying, Fixing,testing and commissioning of fire dampers where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications.

-

-

-

... More
Fire damper

1

-

-

... More
Actuator

3

-

-

... More
Electric Works Design, fabrication, supply, installation, testing and commissioning of LT Panel/Sub-distribution panels fabricated out of 2mm thick for structural members (Load bearing members) and 1.6mm thick for door and covers (Non load bearing members) CRCA sheet in cubicle compartmentalize free standing floor mounted, dust and vermin proof with reinforcement of suitable size angle iron, channel 'T' irons and / or flats wherever necessary. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of zinc chromate primer and final approved shade of enamelled paint. 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415V, 3-phase, 4-wire, 50Hz supply system and lifting hooks shall also be provided in case of large panels. Degree of ingress protection of IP-55. (Main Panel plant Room) Incomer (1 No.): 125A, 4 pole MCCB adjustable Thermal & Magnetic Setting (25 KA) Metering: 0-500 Volts, digital Voltmeter and shall be protected by 2Amps MCBs. 0-150 Amps digital Ammeter (4"x4") and 150/5A, 10VA, CL-1 CTs and selector switch. Phase indicating lamps and shall be protected by 2Amps MCBs. Bus Bars: 250 Amps FP Aluminium busbars, colour coded with heat shrinkable insulation sleeves Outgoing: Nos. 4 pole 63A MCCB (25 KA) ON/OFF/trip (chiller)(2w+1s) = 3 Nos . 4 pole 100A MCCB (25 KA) ON/OFF/trip (HWG)=(1) Nos . 4 pole MPCB with DOL starter suitable for 2.2 kw motor with contactor O/L relay with single phase preventor suitable for motor with ON/OFF indication lamps and push buttons, Digital ammeter with CTs and selector switch, potential free contacts for remote operation in each feeder and Auto Manual Selector Switch as required including auxiliary relay with contacts chilled/Hot water pump = 4Nos (2) Nos. 4 pole MPCB with DOL starter suitable for 1.5 kw motor with contactor O/L relay with single phase preventor suitable for motor with ON/OFF indication lamps and push buttons, Digital ammeter with CTs and selector switch, potential free contacts for remote operation in each feeder and Auto Manual Selector Switch as required including auxiliary relay .for condenser pump (1) Nos. 4 pole MPCB with DOL starter suitable for 1.5 kw motor with contactor O/L relay with single phase preventor suitable for motor with ON/OFF indication lamps and push buttons, Digital ammeter with CTs and selector switch, potential free contacts for remote operation in each feeder and Auto Manual Selector Switch as required including auxiliary relay .for CT (1) Nos. 25A 4 pole MCB (15 KA) ON/OFF/trip for AHU panel

1

-

-

... More
All as item no 57 above but incoming & outgoing as following (Stater Panel for AHU) :- (1) Nos. 4 pole MPCB (25 KA) DOL starter for 2.2 kw AHU ON/OFF indication lamps and push buttons, Digital ammeter with CTs and selector switch, potential free contacts for remote operation in each feeder and Auto Manual Selector Switch as required including auxiliary contacts for smoke signal. (AHU) MCCB 32A 4 pole-1NO for humidification Contactor 32A 4 pole-1NO for humidification 16A MCB spare

1

-

-

... More
XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volts grade, of following cross-sectional area :-

-

-

-

... More
3.5 core 50 Sq mm Al

20

-

-

... More
4core 10 Sq mm Al

20

-

-

... More
4 core 6 Sq mm Al

60

-

-

... More
Supply, installation, testing and commisioning of control cum transmission copper cable/wire of following sizes :-

-

-

-

... More
2 core 1.5 sqmm control cable

50

-

-

... More
3 core 1.5 sqmm control cable

40

-

-

... More
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required

-

-

-

... More
25 mm x 4 mm GI strip

50

-

-

... More
8 SWG GI WIRE

50

-

-

... More
Flexible Connection Supply, Installation, Testing and Commissioning of 65 mm dia flexible connector for following dia. pipe having PN 1.6 working pressure with anti-vacuum rings complete with flanges, nuts, bolts, seal etc.to be installed at chiller suction and discharge.

4

-

-

... More
Flexible Connection Supply, Installation, Testing and Commissioning of 50 mm dia flexible connector for following dia. pipe having PN 1.6 working pressure with anti-vacuum rings complete with flanges, nuts, bolts, seal etc.to be installed at chiller suction and discharge.

8

-

-

... More
S & F 50 MM dia BALANCING VALVE with BUILT-IN MEASURING FACILITY of Gun metal construction up to 50 mm dia. & cast steel/ ductile iron body up to 50 mm dia. as required having flanged construction with SS disc having long pitch with protruded out pipe insulation & suitable for PN 1.6 working pressure for condenser water circulation as required. The Ductile iron body shall be painted with one coat of Inorganic ethyl self-curing zinc silicate primer at 75 microns & a coat of Super High build epoxy MIO Coating cured with polyamide hardener at 150 microns & finally two coats of High Build Gloss Aliphatic Acrylic Polyurethane at 50 micron dry film thickness.

-

-

-

... More
50 mm dia.

3

-

-

... More
Supply, Installation, Testing and Commissioning of On-line, Non Chemical water treatment scale preventer system (suitable for 65mm dia. pipe) having flow rate 38 USGPM

1

-

-

... More
Supply and fix chemical dehumidifier continuous operating complete, with heaters, ducting, electrical connection for 180 Cfm capacity

1

-

-

... More
DG SETS WORKS

-

-

-

... More
Supply and install , testing and commissioning of diesel engine driven generating set with AMF PANEL Panel 62.5 KVA with water cooled engine for 50 KW power generation @ RPM 1500, brushless frame with silencer and Canopy for sound less mode (sound level not exceeding level specified by central pollution control board) and all engine accessories such as self starter, alternator/dynamo and 62.5 KVA electric alternator, 415 volts, 3 phase, 4 wire,50 Hz, Voltage Regulation± 15, Insulation class H coupled to engine with suitable coupling and base frame on foundation as recommended by the manufacturer and consisting of other electrical l components, fuel tank of capacity of not less than for 12 hour run with level indicator installed on suitable steel frame with PCC foundation as per manufacturers instructions, Power Command genset Controller, fuel pipes, Dual spin on fuel filter, Dry type Air cleaner, Shutt off coil with safeties for LLOP/HWT , fuel pipes , bar metre, hour meter , oil temperature gauges, ammeter , ignition switch, radiator with cooling fan, maintenance free battery (12V) 160 AH including suitable size of copper cable leads with terminals, all mountings, accessories and necessary foundation and AVM pads complete as per specified and directed.

1

-

-

... More
Supply , install, testing and commissioning of Eco friendly 62.5 KVA capacity diesel Engine driven generating set with acoustic enclosure made out of CRCA sheet powder coated specially sesigned lifting arrangement / hooks ,meet the latest CPCB , norms of 75 DBA @ 1 mtr distance and as per the testing guide line of CPCB , DG set shall be conforming to IS:10001/10002 and altenator as per IS 13364, water (Coolent) cooled type , self starting system with 12 volt DC supply 3 phase 4 wire AC 415 volt + 5% at 1500 RPM 50 HZ 0.8 PF self excited , self regulated . Automatic voltage regulation , class 'H' insulation type alternator , with AMF (Automastic mains failure) panel for automatic starting at mains failure installled with the following accessories. (A) PRIME MOVER:- Suitable for driving 50 KW/62.5 KVA (89.5) BHP alternator water cooled battery start diesel Engine of suitable capacity confirming of ISO 3046 / BS 5514 BSS 649 and fuel tank suitable for 12 hrs running capacity mounted on MS frame pedestal supported with anti-vibration mounting rated for continuous running capable of taking 10% over load for one hr in any 12 hrs operation complete with (B) ALTERNATOR : 50 KW/62.5 KVA at 0.8 PF Brushless self excited, self regulated 3 phase 50 Hz 415 V 1500 RPM 4 wire screen protected drip proof free from simulation problems continuous rating confirming to BS 5000 complete with automatic voltage regulator 0/P voltage regulated between +/- 1% or set voltage (C) AUTOMATIC MAINS FAILURE PANEL: AMF panel for 64 KW/100 KVA DG Set fabricated out of sheet steel factory made suitable for floor mounting hinged from panel for easy accessibility with suitable rated bus bar internal wiring and with provision for connecting incoming/outgoing leads with the following accessories :- (a) Both in coming and Out going MCCB of rated 150 Amp capacity 4 pole - (03 Nos-) for incoming/Out going

-

-

-

... More
(b) Auxiliary contractors of rated capacity - 02 Nos (c) Voltmeter digital with selector switch - 01 No (d) Ammeter digital with selector switch - 01 No (e) Frequency meter digital with selector switch - 01 no (f) Power factor meter digital type - 01No (g) KWH meter electronic digital type - 01 No h) Two set of indicator lamps 6 Nos LED Type for main and DG indication (i) Master switch for auto/manual/test/off k) One set of lamps for indicating "load on set" "load on mains" set fails to start" low oil pressure" high cylinder tamp" " battery low" (I) Alarm/Hooter m) By charger connected to main supply side to charge bty comprising the following :- n) DC ammeter & voltmeter digital type o) Charge rate selection for tricle or high charge (p) Indicator lamp for bty (q)) Set for easily accessible control fuses (r) Set for relays to auto-start the engine on main failure and low voltage . (s) Emergency trip Note: (i) any fittings/fixtures which are necessary for proper functioning of the DG set shall also be deemed include in the unit rate quoted and shall be provided by the contractor without any extra cost to the Deptt. ii) Necessary foundation for installation of DG set shall be provided as per manufacturers recommendations and cost deemed to be inclusive in the rate quoted for this item. iii) All testing equipments are to be arranged by the contractor and testing shall be carried out by the contractor in presence of Engr-in-Charge and testing result duly signed by the Engr-in-charge and the contractor shall be kept in Record. iv) Rate quoted by the contractor including the rate of first filling of lubricating oil, Coolent and duct with wooden cover from DG set to AMF Panel. AMF panel must be inside of the canopy or as per recommendation of OEM. (v) Drawings/cataloged for DG Set and AMF panel got approved by the GE before ordering to the manufacturer

-

-

-

... More
LIGHTENING PROTECTION WORKS

-

-

-

... More
Supply & fix on roof of building height 05 mtr height of building single pointed air termination copper rod 12mm dia, 300 mm dong all as specified and directed by Engr-in-charge.

15

-

-

... More
Taking down existing Alumunium strip 20 x 3.15mm on wall/floor with saddle and spacersl as specifed and as directed ny Engr-inCharge.

80

-

-

... More
Material an labour for fabrication for temporary shader of flate plate and fix framed work such as grills, gratings etc, with ends of bars shoulderd and / or riveted or forged into spikes, framed guard bars, barred iron doors, ladders , framed balusters, walk ways, railing, framework of water tanks , Bar protection of bolard light and similar work conforming to FE ,290. GDE E-165

1500

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.