Military Engineer Services Tender
... More
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 90,000Document Cost
₹ 500Tender Fee
Refer Documents
Summary
Repair/ Maintenance Of Lt Panels, Ug Cables, Distribution Network,spv Works And Certain E/m Repairs For Mh Units, Institutes, Messes Under Aor Of Ge (east) Jalandhar Cantt
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2025_MES_700335_2Tender No
GE/JULL/ET-76/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
(9) Earthing Strip Check Visual Check-Monthly
(10) DC and AC termination checks and retightening as required in Inverters -Visual Check-Half Yearly
(11)Cleaning of Filters in Suction Side of Inverters -Monthly
MANDATORY SPARES:-
-
-
-
... More
Material and labour in replacement for testing and commissioning of 11KV outdoor type CT PT Combo metering unit having BIL 28KV at 1minute power frequency with 75KV impulse withstand voltage with short time thermal current rating 18 KA at 3 sec min. having CT ratio 100/5A , burden 10VA , accuracy class 0.2 , having 3 Nos of PT's with ratio 11000V/110V, burden per phase 50 VA ,Accuracy class 0.2,voltage factor 1.2cont. & 1.5 for 30 seconds completely.
1
-
-
... More
Returing, filling in,soft/loose soil, including spreading, leveling watering and well ramming in layers not exceeding 25 cms thick each layer compete all as specified and directed by Engineer-in-Charge.
11.52
-
-
... More
Material and labour for RS-485 cable having overall double screen, PVC sheathed complete 2 pair, 0.5 Sqmm min complete all as specified and as directed.
100
-
-
... More
Supply and fix GI pipe 80 mm bore light grade in replacement for protection of cable including provn of PVC heavy duty bends complete for fixing along GI pipe along wall/ pole/laid under the road/ floor complete all as specified and directred by Engr-in-Charge.
20
-
-
... More
(a) Manpower
(i) Minimum one Engineer (Degree in electrical Engineering with 02 years of experience in working in O&M of Solar PV Plants or a relevant Diploma in Engineering with at least 3 years of experience of working in O&M of solar PV plants will responsible for plant operation and maintenance. (ii) 01 Nos of skilled electrician in a shift of 08 hours (Min 1 shift per day) having 10+2 with min 3 year experience in relevant field. (iii) 03 Nos of unskilled Labour in day shift of 08 hours (iv) 01 No unskilled labour in a shift of 8 hours (Min 2 shifts per day i.e. Evening, Night)
(iv) The contractor shall employ only such personel who are adequately qualified and experienced in Solar PV Project. The contractor shall submit adhar linked t bank statement for monthly payment made to employed personnel, ESI as applicable within one week after acceptence of work . In case of absenteeism, a recovery of Rs 700 per Helper and Rs 1000 per electrician and Rs 1300 per Engineer will be levied. THe quoted rate include cost of reliver reqd for weekly off for employed manpower for electrician and helper.
(b) Tools/Plants/Testing Equipments As per site and OEM recommendations within quoted rates.
-
-
-
... More
Removal of surplus soft/loose soil soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by Engr-in-charge.
10.08
-
-
... More
Major Eqpt Details:-
i) Module - 3176 Nos - 330 Wp, system voltage 1500VDC, Make Waaree ii) No. of modules / strings - 40 Nos approx (DC 1000V 400A)
iii) Inverter - 02 Nos - 500 Kw, Model No PVS 800, Make ABB
iv) Data logger - 1
v) WMS - Pyranometer (irradiation meter - 4 Nos Make - Kipp & Zonen - Wind speed meter -1 Nos Make - Trinity - Module Temp sensor & Ambient temperature sensor - 1 Nos, IMT Technology Make - Trinity
vi) ESE type Lighting Arrester- 2 Nos Make- JMV LPS
vii) 11KV VCB 800Amp-01 Nos, viii) HT Cable of size 185sqmm 3 core-290 Mtrs approx
ix) ,DC Cable- 1176 Mtrs, x) LT 1.1 KV annealed plain copper armoured XLPE insulated cable of size 95 Sqmm 2 core - 900 mtr approx. SCB to inverter & inverter to Transformer LT 1.1 KV annealed plain copper armoured, XLPE insulated cable of size 150 sqmm 1 core - 300 Mtr approx
xi) String combiner Box - 04 Nos
-
-
-
... More
M & L for sinewave invertor of min 2KVA capacity (Make: Microtek, Luminous) with inverter battery 12V 180Ah -02 Nos(Make: Exide,Luminous) with all connection accessories complete and all as specified.
1
-
-
... More
(c) Spares: The Contractor shall maintain required Spare Plant Equipment., Spare Parts, Tools and Plants, Consumables required for comprehensive operation and maintenance of the plant faciltiy. The Contractor shall make arrangement to procure required spare parts, or equipments as required, overhauling of parts, tools and equipment, required to operate and maintain the Plant in accordance with the recommendations of individual Original Equipment Manufacturer (OEM) at his/ her own cost. Minimum spares required to be maintained by the succesful bidder. Notes:-
(a) The scope also include washing/cleaning of Solar PV Modules fortnightly basis as per pre-planned schedule as got approved from deptt by contractor and cost of T&P (wiper long handle, grass cutting machine, ladder etc), Labour required at site is deemed to be included in quoted rates. The contractor shall have to purchase LEVEL- I AMC plan for Inverter - 2 Nos from ABB within overall quoted rates.
(b) Checking electrical parameter of the installed power plant .Any job other than above indicated jobs would be covered under warranty of Solar Plant installed.
(c) Keeping the area neat and clean and free from vegetation growth all over ground in solar plant(Note: Recovery to be deducted at the rate of Rs 1000/day if not found clean during visit)
-
-
-
... More
Supply and fixing replacement MC4 connector 2 in 1 ( Y connector) in replacement for, IP-68, 1000V DC, rated current 30 Amp min to connect 6 Sqmm solar cable complete all as specified and directed. Make ELCOM or equivalent
60
-
-
... More
(d) Pyranometer (Irradiation Horizontal) - Data is not showing in SCADA system. (e) Module Temperature Data - Not showing in SCADA system.
(f) PV modules not working.
(g) String not working due to DC cable fault. (h) Module surface temperature not shown. (j) Ambient temperature not shown in scada.
-
-
-
... More
Material & labour in replacement for Polycrystalline Solar Photovoltaic PV modules not less than 330Wp, 72 cells approx, system voltage 1500 VDC, MNRE approved suitable for existing solar plant. Note: Old unsv PV modules will be deposited in MES store yard.
10
-
-
... More
M&L for Factory made, machine pressed pre-cast concrete, interlocking paver block with grey cement & no pigment set and jointed over and including 25 mm thick dry sand bedding as in floors cushioning layer below interlocking paver blocks including watering and consolidation complete and pavings of selected shape and size as approved by GE conforming to (IS:15658-2006) of 60 mm thick, M-30 grade, complete all as specified and directed by Engineer-in-Charge.
80
-
-
... More
Supply & laying in replacement of un-reinforced precast concrete cable cover, class LV, type I, flat, size 250mm x 150mm x 40mm laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/abutting each other complete all as specified and directed by Engineer-in-charge.
960
-
-
... More
(ix) The Operators shall perform the services in relation to the Plant in accordance with the safety manageement plans.SOPs and procedures as applicable and/or in accordance with accepted industry practise.The operators shall adhere to the health and safety standard. In this respect the Department shall not be liable for any accidents or untoward events.
(x) The Contractor,for any major equipment fail such as Inverters/Solar Module/ACDB shall repair/replaced the equipment on free of cost basis. The Old Inverter and Solar PV Module shall not be a property of Contractor and has to be deposited by him in the MES Store.
Preventive Maintenance Schedule & Checklist
(1) PV Module cleaning after 15 Days min.
(2) Module Interconnects Tightness -Visual Check Monthly.
(3) Integrity of Cable Terminations in Junction Box in Visual Check-Monthly
(4) Visual Inspection of Cracked ,Chipped and Broken Modules-Monthly
(5) Visual Inspection of Rodent Attacks on Cable Conduits -Monthly
(6)Visual Inspection of Junction Box & Combiner Box enclosures -Monthly
(7) Hardware on Structures - Monthly
(8) Vertical Post Structures Rigidity -Visual Check Quarterly
-
-
-
... More
Material and labour in replacement for Air Filter, AIR-TEXT, 518 x 540, AIR-TEX G-150 model, component/ part No 64666533 suitable for PVS 800 inveters complete all as specified and as directed.
4
-
-
... More
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches, punned down to thickness of 18cm complete all as specified.
Note: punned down thickness of 18cm shall be measured for payment.
8.64
-
-
... More
Supply and fixing in replacement for MC4 connector, IP-68, 1000V DC, rated current 30 Amp min to connect 6 Sqmm solar cable complete all as specified and directed. Make ELCOM or equivalent
60
-
-
... More
Material and labour for Boring hole under the road/ pavement/ hard standing and inserting HDPE pipe of 100mm at a depth not less than one metre below ground level complete all as specified & directed. Note: The quoted rate includes cost of HDPE pipe 100mm pipe min
20
-
-
... More
Name of the site-Jalandhar Cantt, Capacity-01 MW
(a) 2021-22(27 Jan 2021 -31 Mar 2022)- 10.71%
(b) 2022-23(01 Apr 2022 -31 Mar 2023)- 13%
(c) 2023-24(01 Apr 2023 -31 Mar 2024)- 11.87% (d) 2024-25(01 Apr 2024 -10 Dec 2024)- 13.90% Generation (KWH) Report of the plant in last five years
Name of the site- Jalandhar Cantt,Capacity- 01 MW
(a) 2021-22(27 Jan 2021 -31 Mar 2022)- 169883 KWH
(b) 2022-23(01 Apr 2022 -31 Mar 2023)- 1089784 KWH
(c) 2023-24(01 Apr 2023 -31 Mar 2024)- 1217604 KWH
(d) 2024-25(01 Apr 2024 -10 Dec 2024)- 888192 KWH Note:- 1. The succsesfull bidder shall rectify the defects within 45 days of acceptance of the work order in the both the solar power plants such that minimum capacity utlisation factor (CUF) of 13% for plants is maintained.
2. Reducinq plant downtime. The Contractor shall ensure the plant availability upto 99%. However, the plant availability due to grid outages will be considered only if the same are certified by the competent authority/ GE. Any other outages which are not attributable to the Contractor and are certified by Department may also be considered. 3. Linear degradation of the module output (i.e., 0.75% of DC capacity at Std temp Condition per year) shall be considered for the calculation of CUF every year.
-
-
-
... More
Manning, operation and comprehensive maintenance of complete 1 MW On Grid type Solar photo Voltaic Plant (SPV) Project at Jalandhar with SCADA system having Polycrystalline PV module 330Wp (system voltage 1500 volt) - 3176 Nos, Vacuum Circuit breaker 800 Amp - 01 No, String Combiner Box - 04 Nos, Power control unit with inverters 500 KW - 02 Nos (make ABB), Step Up Transformers 1250 KVA - 01 Nos Make Voltamp, SCADA System for solar plants with all sensors i.e. pyranometer, temp sensor, Weather monitoring sensor etc and metering equipment's installed.
Plant Description
Location - Jalandhar Cantt
Latitude - 31.2825822
Longitude - 75.6325972
DC Capacity - 1048 KWp AC cap - 1 MW
Design and drawing documents - Available
Commissioning date - 27 Jan 2021 Operational Acceptance - Yes
DISCOM - PSPCL
Connectivity voltage - 11kV Main Grid - 66 kV, solar connected with 11 kV at MH The defects to be recified by the sucessful Bidder:- (a) Ambient Temp sensor not working (b) Module temp sensor not working. (c) Pyranometer (Inrradiation tilt) - Data is not showing in SCADA system.
11
-
-
... More
Material & labour for Ambient Temperature sensor complete with housing, cable etc confirming to Model No Ta-ext-RS 485-MB of make IMT Technology complete all as specified and directed.
1
-
-
... More
Supply, laying, jointing, testing and commissioning in replacement of XLPE insulated amoured heavy duty electric cable single core with copper conductor of 95sqmm,1100 volts grade, SCMB to invertor and as per IS 7098:Part 1:1988 including necessary cable accessories.
200
-
-
... More
Supply and fixing DEFLAME CO2 based wheeled fire extinguisher 6.5 kgs sutable for fire rating class C completely and all as specified by engr-in-charge.
20
-
-
... More
Material and labour in replacement for Air Filter, CC-CM518 x 540, AIR-TEX G-150 model, component/ part No 64665324 of ABB suitable for PVS 800 inveters complete all as specified and as directed.
6
-
-
... More
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables complete all as specified and directed by Engineer-in-Charge.
21.6
-
-
... More
(B) Maintenace :-
(i) The Operators shall be responsible for ensuring smooth operations of all components.
(ii) To inspect and maintain periodically the plant equipment as per the preventive and curative maintenance schedule.
(iii) The operators shall carry out PV module cleaning Twice every month min or as required for effective generation as required.
(iv) Spares such as MCB,MCCBs,Fuses,DC Fuses,Al cards such as input/output Card ,power supply card ,processor card ,PV Modules, Glands,lugs,MC4 connectors,tie connectors,clamps,cable Ties and all other consumables/spares which are required for uninterrupted O&M of the Plant should be kept readily available at Site . The quoted rate include cost of the all such items reqd (except mentioned in Sr No 2 to 10) in rate quoted for Item No 1.
(v) The Contractor shall provide an inventory report items consumed to the departmment on a monthly basis.
(vi) The Contractor has to use the mandatory spares(s) available at site for replacing defective part(s) of equipment for minimizing system outage temporarily and top up the quantity of spares so that the required quantity of spares shall be made available at site at all times and shall be handed over to the department at the end of O&M Period .The cost of spares is deemed to be incl in the quoted cost.
-
-
-
... More
Supply, laying, testing, jointing in replacement for annealed tinned copper conductor cable 1.8 KV DC EBXL Halogen free XLPO/ XLPO 120 degree centigrade, UV resistant ZH-FRLS single core 6 sqmm solar sheathed industrial solar cable complete all as specified and as directed.
500
-
-
... More
M & L for Construction of the fire point size 2.0 mtr length,1.5 mtr breadth and 1.5 mtr height fabricated with MS angle iron of size 60x60x6mm and CGI sheet of thickness 0.63 mm having coating of 120 gm/sqm with two comgated side laps (grade B comgated side laps) as in roof fixed with 'L' or 'J ' type cranked hosk ,bolts and painting with two coats synthatic enamel paint (red colour)over a coat of red oxide primer, word 'FIRE POINT' written in white enamel paint over sheet with each letter of width and height of size 15cm x 15cm .The fire point shall comprise of sand pit and inside dimension 1.4x1.1x0.6 m deep constructed out of PCC block masanory with 4 hooks to hang buckets and necessary support to hold fire hook,fire brush etc all as speciifed and directed.Note : (i)Cost of fire bucket-2 Nos of capacity 10 ltr made of MS sheet with word FIRE written with synthatic enamel paint should be included in quoted rates. (ii) Drawing of fire point will be approved by Engr in charge note: Before incorportion of work drawing will be approved by GE.
6
-
-
... More
Material & labour for Solar PV module Temperature sensor complete with housing, cable etc with RS 485 port suitable for existing Solar plant, SCADA system of make IMT Technology complete all as specified and as directed.
1
-
-
... More
Supply, laying, testing, jointing in replacement of annealed tinned copper conductor cable 1.8 KV DC EBXL Halogen free XLPO/ XLPO 120 degree centigrade, UV resistant ZH-FRLS single core 4 sqmm solar sheathed industrial solar cable complete all as specified and as directed
100
-
-
... More
(vii) The Contractor is bound to provide mentioned manpower. However, the above mentioned manpower is minimum. If highe number of manpower is required to ensure smooth functioning of plant. the cost of same will be deemed to included in quoted rates. Contractor shall get duty roster and shift timing approved from deptt well in advance required for smooth maintenance. The rate quoted include cost of items reqd for maintenance inclusive of daily,weekly,quarterly ,half yearly maintenance including all consumable material and chemicals as required and other spares required.
(viii) Earthing Register has to be maintained by the Contractor.The earthing values of all Earting mentioned in Appx'A' of LA and Solar Earthing is mandatory and any earthing material required to recharge of the earth pit shall be borne by the Contractor. The cost of New Earthing alongwith connected accessories like earthing strip,excavation etc if required to executed at site is deemed to be incl in the quoted rates.
Note: if the Earthing Value comes to be more than 3 Ohm .The Contractor has to recharge and make good the earthing value.If required he has to execute new earth pit at no extra cost to the department .In case of Non compliance a penalty of Rs 500 Per day per earthing shall be levied .And the same shall be recovered from his Payment.
-
-
-
... More
(d) Material and Labour for replacement of defective power condition units(PCU)/Inverters /String invertor with maximum power point tracker/Tracking (MPPT) feature,cable and other electrical works shall be included in the O&M Quoted Cost.
(e) Cost of equipment and spare parts shall be included in the O&M quoted Cost.
(f)The Operator shall operate and maintain the Plant in accordance with the provisions of this O&M Plan/O&M Procedures and Good Industry Practices.
(g) Operator shall observe and strictly comply with the Applicable Laws for the operation and maintenance of the Plant in accordance with the provisions of this O&M.
(A) Operations:-
(h) Measurement & monitoring of the electricity production through appropraite monitoring systems for the period of the Term of the contract.
(j) The following will be monitored:-
(i) Measurement and calculations of the Plant current and nominal performance.
(ii) Any unusual conditions found during operations/ inspections.
(iii) Any system disturbances/outages.
(iv) Monthly report of the solar plant generation is to be provided by Contractor.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%