Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 47,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2019_MES_302784_2Bid Award Id
ViewTender No
8149/GE/E/FZR/19-20Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
M & L for sand cushioning with a layer of fine sand(sand for plastering) 8 cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified and directed Note:intrenches over the cable protection
92.3
-
-
... More
Supply and laying well burnt old size sub class 'B' bricks laid flat with width equal to length of brick perpendicular to the direction of cable , adjacent/abutting each other complete all as specified and directed
8.22
-
-
... More
Supplying ,erecting and fixing Pre-stressed concrete poles 9 mtr long of cross section 102mmx172mm at top and 102mmx279mm at bottom Class 10 compluing with requirement of IS-1678-1978 including painting of poles with two coats of synthetic enamel paint in black and white strips each 30 cm wide each up to 1.5mtr high from coping over a coat of primer including numbering of poles complete all as specified and directed
39
-
-
... More
M&L for PCC(1:4:8) type D-2 using 40mm graded stone aggregate as in foundation of electric poles, complete all as specified and directed
2.11
-
-
... More
M&L for PCC(1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of assembly,bed concrete including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specifieds, including necessary form work complete all as specified
18.3
-
-
... More
M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of poles and similar work including necessary form work and fair finish to exposed surfaces without using extra cement complete all as specified and directed
3.9
-
-
... More
Supply and lay XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 sq mm 3.5 core. complete all as specified and directed
1144
-
-
... More
S&F danger notice plate for LT poles of size 20cmx15 cm of 1.6mm thick mild steel sheet vitreous enamelled white with letters,figure and conventional skull and bones "DANGER" in Punjabi,Hindi & English etc. in signal red colour and fixed with MS clamps made out of 25mmx3mm MS flat iron bolts,nuts complete including one coat of red oxide primer complete all as specified and directed
39
-
-
... More
Supply and fixing GI pipe bracket for street light fittings made out of 32mm-50mm dia GI pipe medium grade 1.2 mtr long bent to required angle/shape with and 2xpair of MS clamps made out 40mmx5mm MS flat iron bolts,nuts complete including two coat of synthetic enamel paint (first grade) over a coat of red oxide complete all as specified and directed
39
-
-
... More
Supply & fixing of LED Street light 100 Watt made up of pressure die cast housing with toughned glass Aesthetically designed roadway luminiare with excellent thermal management IP 66 protection Make- Havells cat part No ENDURACITYLINERNEOSL 100WLED757SASYBOTG or equivalent make of CROMPTON /Bajaj as approved by GE.
39
-
-
... More
Supply and fixing automatic street light switch for automatic swithcing of street light/high mast light (timer switch) Integrated VMS Model for Three Phase Load light. The sensor alongwith suitable power contractor as per IEC - 60947-4-4 , MCB and support terminal and enclosed in pole/wall mounted factory made PVC enclosure made out of rust , shock, termite proof and FR grade confirming to IP 55 of capacity 5 KW, Three phase of Make- Kaktiya Energy system (model - swadeep 02EC3 KW1P or other quivalent make of bajaj/Havells as approved by GE)
2
-
-
... More
Supply & fixing street light pole mounted cable junction box IP-65 of Size 200x160x98 with four terminal for 3 phase /4 core made out of thermal plastic material suitable for 16/25 UG sqmm cable including clamps Made out of MS flat 40x5mm including bolts, nuts duly painted etc complete all as specified & directed Including taking out Old unserviceable Junction box and connected item/material Make : Hensel CAT part No k 9255 or equivalent of sintex
39
-
-
... More
Supply & fixing 3core 1.5 sqmm PVC insulated and FR PVC round sheathed copper conductor flexible 1100 volts for connection from OH Line to street light fittings. Make :Polycab/ Havells or other equivalent makes as approved by GE.
293
-
-
... More
M&L for Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick, buried directly in ground vertically to a depth not less than 3 mtr below ground level with top edge of the earth plate at a depth not less than 2.25mtr below ground level,earth plate surrounded from all sides by 15cm thick packed layer of charcol dust and common salt filling in alternate layers,all around,top and bottom and electrode connection by using galvanised iron earth lead wire 4mm dia by means of bolts,nuts,check nut,and washers made of galvanised iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanised iron pipe 15mm bore protection pipe light grade for protection strip upto 3m above ground level fixed with two clamps of size 25mmx3mm flat iron and connected to running earth wire at top of poles for for protection of GI wire.PCC chambeer in cement concrete(1:3:6) type C-2 and RCC pit cover in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate complete all as shown in electric plate No-3 of the MES standard schedule of rates (Part-I) of 2009 (a) The quoted unit rate shall include for protection pipe, GI water pipe, funnel,wire mesh excavation,RCC pit cover,test point,4 mm dia galvanised iron wire from top of earth plate upto 5mtr above GL anf if GI protection is less than 5m,no price adjustment shall be made
(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings,junction,elbow etc shall be deemed to be included in the quoted unit rate
(c) If the testing result of earth Wk is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be admissible on this account only.
(d) Earthing work will becarried out in presence of MES representative.
4
-
-
... More
M&L Earth continuity condutor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified and directed
1144
-
-
... More
Supply and fixing GI pipe from junction box to street light fittings of dia 40 mm light grade 6 mtr long with 2xpair of MS clamps made out 40mmx5mm MS flat iron bolts,nuts complete including two coat of synthetic enamel paint (first grade) over a coat of red oxide complete all as specified and directed
39
-
-
... More
Supply and fixing GI pipe from bottom of PCC coping to Junction Box of dia 40 mm Light grade 1.5 mtr long with and a pair of MS clamps made out 40mmx5mm MS flat iron bolts,nuts complete including two coat of synthetic enamel paint (first grade) over a coat of red oxide primer complete all as specified and directed
39
-
-
... More
Supply , installation, commissioning of Water cooler fully stainless steel, electric driven single phase having aprrox storage and nominal cooling capcity 60/120ltrs with all Accessories alongwith PVC connection pipe 15 mm bore of suitable length as required at site, complete all as specified and directedmake Voltas/Sidhwal/ Bluestar.as approved by GE
4
-
-
... More
Supply , installation, commissioning of Water cooler fully stainless steel, electric driven single phase having aprrox storage and nomonal cooling capcity 40/80ltrs with all Accessories and PVC connection PPC of 15 mm bore of suitable length as required at site, complete all as specified and directed. Make Voltas/ Blue star.
4
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 v to 250 v with output voltage stabilized at 230 volt with accuracy of + -2.5% and of capacity 2 KVA complete all as specified and directed Make- Bluebird 2 KVA , model-bw213 bluebird. or equivelent in V-guard or other equivalant make as approved by GE.
6
-
-
... More
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & desined for input variation between 170 v to 250 v with output voltage stabilized at 230 volt with accuracy of +-2.5% and of capacity 1 KVA complete all as specified and directed.
2
-
-
... More
Supply and draw sub main wiring of two run 4.0 sqmm single core PVC insulated, unsheathed multistarnded copper conductor cabel (FRLS) 1100 Volt grade, draw through and including PVC conduit heavy duty and accessories of 25 mm size and fixed with PVC saddles and cadmium plated steel screws to the surfaces of the wall/ceiling including one run of 2.5 sqmm single core PVC insultated unsheathed copper earth continuty conductor complete all as specified and directed (Note : Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length)
115
-
-
... More
Supply and fix Single pole and neutral encosure with a two pin and earth plug socket complete with one single pole MCB of 20 Amp capacity 'C' series complete all as specified and directed. Make- Indo Asian/Standered/HPL as approved by GE
8
-
-
... More
Supply and fix Galvanised iron steel tubing medium grade of size 15mm bore complete with all fittings such as bend, tee, reducer, elbow and union of require size complete all as specified and directed.Make :- Jindal/ Prakash Surya/Jindal star as approved by GE
52
-
-
... More
Supply and fix gun metal or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15 mm dia ISI marked,complete all as specified and directed.
8
-
-
... More
Providing cement concrete of type B1 1:2:4 with 20 mm graded aggregate in foundation, including rafts footing, foundation beams, plinth beams, basement for water coolers complete all as specified and directed.
3
-
-
... More
Supply and fix Desert cooler electric driven single phase having nominal air flow capacity of 4000 cum/hr, with working voltage240 v 50 hz, made of 20 guage sheet of ISI marked, size not less than 90x70x70 cm surface area from top and bottom , 68x54 cm from front grill size including Tullu pump with 4 nos piano type 5 Amp switch on front side including one coat primer and two coat of synthetic enamel paint, inner tank coated with rust proof paint (steel body) with minimum volume of inner water tank is 80 Ltrs complete and thickness of tank is not less than 18 guage , fitted with coppper winding electric motor of Compton / Khaitan/ Bajaj as approved by GE
34
-
-
... More
Supply & fix Air termination,Single pointed aluminium rod 12 mm dia and 300 mm long mounted on GI pipe light grade 32 mm dia 1.5 Mtr long with MS clamp fabricated out of 40x3 mm thick flat iron including bolts, nuts duly painted and necessary PCC foundation 1:4:8 of size .20X.20X.30 complete all as specified and directed.
30
-
-
... More
Supply & fix aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc for roof conductor above ground complete all as specified and directed
110
-
-
... More
Supply & fix Earth continuity conductor or main earthing lead of size 32x6mm galvanized flat iron strip fixed to wall on pattern or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required complete all as specified and directed.
32
-
-
... More
M & L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 no.s 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
10
-
-
... More
Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick, buried directly in ground level with top edge of the earth plate at a depth not less than 2.25mtr below ground level,earth plate surrounded from all sides by 15cm thick packed layer of charcol dust and common salt filling in alternate layers,all around,top and bottom and electrode connection by using galvanised iron earth lead strip of size 32x6mm flat iron by means of bolts,nuts,check nut,and washers made of galvanised iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanised iron pipe40mm bore protection pipe light grade for protection strip upto 3m above ground level (Up th the body of equipments) PCC chambeer in cement concrete(1:3:6) type C-2 and RCC pit cover in M-25 (design mix) complete all as shown in electric plate No-3 of the MES standard schedule of rates (Part-I) of 2009 complete all as specified and testing on completion:-
(a) The unit rate shall include for protection pipe, GI water pipe, funnel,wire mesh excavation,RCC pit cover,test point,32x6mm galvanised strip from top of earth plate upto 5mtr above GL anf if GI protection is less than 5m,no price adjustment shall be made
(b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings,junction,elbow etc shall be deemed to be included in the unit rate
(c) If the testing result of earth Wk is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be permissible on the account
(d) Earthing work will becarried out in presence of MES representative.