Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date9 Feb 2024
Closing Date10 Jun 2024
Tender Amount₹ 11,34,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----% For detail refer to Annexure-III, BLOCK-3 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----%. For detail refer to Annexure-IV, BLOCK-4 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----%. For detail refer to Annexure-V, BLOCK-5 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----% For detail refer to Annexure-VI, BLOCK-6 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----%. For detail refer to Annexure-VII, BLOCK-7 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----%. For detail refer to Annexure-VIII, BLOCK-8 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----%. For detail refer to Annexure-IX, BLOCK-9 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----% For detail refer to Annexure-X, BLOCK-10 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----%. For detail refer to annexure-XI, BLOCK 11 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----% For detail refer to Annexure-XII, BLOCK-12 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 06 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----%. For detail refer to Annexure-XIII to XV, BLOCK-13 to 15 (containing in Vol-II)

3

-

-

... More
Completion of balance work and rectification of defects, if any for construction of SMQ block of 05 Qtrs (G+2 story) complete all as specified and shown on drawing. Present work done in percentage completed by defaulting contractor is -----%. For detail refer to Annexure-XVI, BLOCK-16 (containing in Vol-II)

1

-

-

... More
Completion of balance work and rectification of defects, if any for construction of Garbage Bin (Covered) and sign Board complete all as specified and shown on drawing.Present work done in percentage completed by defaulting contractor is 0.00%.

4

-

-

... More
NOTE: Schedule ‘A’ Part II to XII under Ser No. 2.01 to 2.11 are Prepriced by MES.

-

-

-

... More
Lump sum price worked out by the Contractor for “EXCAVATION AND EARTH WORK” as listed in Schedule ‘A’ Part II

1

-

2888996.93

... More
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION"” as listed in Schedule ‘A’ Part III

1

-

5579603.91

... More
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY"” as listed in Schedule ‘A’ Part IV

1

-

818662.42

... More
Lump sum price worked out by the Contractor for "SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part V

1

-

1349992.41

... More
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part VI

1

-

3128275.2

... More
Lump sum price worked out by the Contractor for “ROAD AND PATH” as listed in Schedule ‘A’ Part VII

1

-

8433353.01

... More
Lump sum price worked out by the Contractor for “FENCING AND GATE” as listed in Schedule ‘A’ Part VIII

1

-

231568.45

... More
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY ” as listed in Schedule ‘A’ Part IX

1

-

726994.99

... More
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION ” as listed in Schedule ‘A’ Part X

1

-

3415493.61

... More
Lump sum price worked out by the Contractor for “DEMOLISHION AND DISMANTALING” as listed in Schedule ‘A’ Part XI

1

-

185154.63

... More
Lump sum price worked out by the Contractor for “SOLAR WATER HEATER” as listed in Schedule ‘A’ Part XII

1

-

978052.61

... More
SCHEDULE `A' PART - XIII MISC ITEMS is not prepriced by MES and prepriced rates indicates 0.0 under column 6 signified this fact only.

-

-

-

... More
INTERNAL ELECTRIFICATION

-

-

-

... More
S & F modular flush Box for mounting of modular cover plate 8 modules complete all as specified and directed.

285

-

-

... More
S&F of lamp holder insulated body with back plate for batten fitting with LED lamp 09 watt complete all as specified and directed.

855

-

-

... More
S&F energy saving decorative box type batten light fitting surface mounted complete with high efficiency PMMA diffuser soft glare free light LED lamp 20 watt suitable for 120 volts to 270 volts of system efficacy not less then 100 lumen/watt, with all accessories, pre-wired, including lamp and providing flexible copper wire, twin core cable complete all as specified and directed.

492

-

-

... More
S&F LED sleek mirror light fitting 05 watt provided with high output diffuser 2 ft long, suitable for 120 volts to 270 volts of system efficacy not less then 100 lumen/watt, complete with all accessories, pre-wired including lamp and providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.

190

-

-

... More
S&F LED bulkhead luminaire 10 watt, wall/surface mounted complete with LED lamp 10 Watt, complete with all accessories, pre-wired including providing flexible copper wire, twin core cable complete all as specified and directed by Engineer-in-Charge.

64

-

-

... More
NOTE FOR ITEM N 3.02 TO 3.06 :- (i) For all types of LED fittings and luminaire should be same manufacturer. (ii) LM -79 certificate for all light fittings shall be submitted by the contractor before fixing at site or taking payment against material. (iii) System efficacy should be more than 100 lummens / watt (iv) CRI should be 80 (v) THD should be less than 20% (vi) PF should be more than 0.95

-

-

-

... More
Supply and fixing ceiling fan five star 1200mm sweep complete with out fan regulator 230 volts (single phase) and provisioning of flexible copper cord of size 23/0.0076 of required length from ceiling rose or connector to ceiling fan for giving connection complete all as specified and as directed.

285

-

-

... More
Supply and fixing fiber body exhaust fan with louvers of size 300 mm sweep, 900 RPM 230 volts single phase AC supply complete with, bolt, nuts and washers, suitably embedded in the wall/prefabricated sheet etc including making suitable opening and provisioning of flexible cord copper of size 23/0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and directed.

285

-

-

... More
Supply and fixing electronic two modular fan regulator step type 120 Watts complete all as specified and as directed.

285

-

-

... More
S&F MCB SP 6 to 32 Amps, B curve type 10 KA breaking capacity 240 Volts complete all as specified and directed.

570

-

-

... More
S&F MCB SPN 32 Amps, B curve type 10 KA breaking capacity 240 Volts complete all as specified and directed.

95

-

-

... More
SOLAR WATER HEATER

-

-

-

... More
Supply, Install, Testing and Commissioning of 'Solar Hot Water System' Flat plate collector based on indirect transfer of heat of capacity 100 Ltrs Per day including all standard accessories with electric backup complete all as specified and directed. Notes:- (a) System shall be installed by OEM or their authorised representative. (b) Cost of Hot water tank, staging, electrical backup ( As per recommendation of Manufacturer is included in overall cost quoted. (c) System shall be periodically checked by authorised representative of firm at interval of three months till completion of defects liability period. Any defects shall be made good without any extra cost to Govt. (d) Rate of solar water system includes the cost of backup stainless steel hot water tank insultated.

95

-

-

... More
S&F 15 mm bore GI pipe for Hot water piping with connections/fittings duly insulated with glass wool 25mm and aluminium cladding, complete all as specified and as directed.

1120

-

-

... More
S&F rigid metallic conduit 15mm dia including all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as coupler, lock nuts, saddles and pipe hooks etc. complete all as specified and directed.

760

-

-

... More
EXTERNAL WATER SUPPLY

-

-

-

... More
Supply, laying jointing and testing centrifugally cast (spun) ductile iron pressure pipe 150 mm bore with socket and spigot ends having ISI stamping marking with IS 8329/2000, class K9 in standard length of 0.50/6.0 m, suitable for and including push on joint (gasket D jointing) with cement morter lining complete all as specified and directed by Engr-in-Charge. Notes: (i) The quoted rates shall be deemed to include for supply, laying and jointing, rubber gasket 'D' jointing push of joints, required for laying the pipes/fittings and for taking the branch connections. (ii) Fittings, excavation and earth work shall be measured and paid for separately under respective item. (iii) The testing of he pipe will be carried out after laying and jointing all as per IS : 8329:2000 to the satisfication of the GE with out any extra cost. (iv) The measurement of the pipes shall be net as fixed between the fitting including short lengths without any allowance for cutting and waste and for portion entering the sockets of pipes and fittings. (v) No separate payment for cutting of pipes and no allowance for cuts necessitated during the work shall be made. (vi) Cost of all the above elements shall be deemed to include in the quoted rates of above items.

320

-

-

... More
Supply, laying jointing and testing centrifugally cast (spun) ductile iron pressure pipe 100 mm bore with socket and spigot ends having ISI stamping marking with IS 8329/2000, class K9 in standard length of 0.50/6.0 m, suitable for and including push on joint (gasket D jointing) with cement morter lining complete all as specified and directed by Engr-in-Charge. Notes: (i) The quoted rates shall be deemed to include for supply, laying and jointing, rubber gasket 'D' jointing push of joints, required for laying the pipes/fittings and for taking the branch connections. (ii) Fittings, excavation and earth work shall be measured and paid for separately under respective item. (iii) The testing of he pipe will be carried out after laying and jointing all as per IS : 8329:2000 to the satisfication of the GE with out any extra cost. (iv) The measurement of the pipes shall be net as fixed between the fitting including short lengths without any allowance for cutting and waste and for portion entering the sockets of pipes and fittings. (v) No separate payment for cutting of pipes and no allowance for cuts necessitated during the work shall be made. (vi) Cost of all the above elements shall be deemed to include in the quoted rates of above items.

200

-

-

... More
Supply & fixing Ductile iron fitting such as bend, increasing, decreasing or double socket, Tee pieces single branch, 'Y' junction, double branch, cross (all sockets or socket and spigot) collars, tail pieces with one end flanged (Integrally Cast) and one end socket Spigot caps and plugs, upto 100 to 150 mm bore ductile iron pressure pipes, of K-9 classification and puch on flexble rubber gasket joints complete all as specified and directed by Engineer-in-Charge.

350

-

-

... More
M&L for construction of brick masonary valve pit of size 90x90x90cm internal dimensions (230mm wall thickness) including mild steel sheet cover 3mm thick over and including angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer with locking & fixing arrangement and brick work and all inner sides/bottom of pit shall be plastered with cement mortar (1:4) 15mm and including foundation concrete (1:4:8) type D-2 using stone aggregate 150mm thick, including excavation in soft/loose soil, returning filling, disposal of surplus soil within 50 metre and cement concrete(1:2:4) type B-0 as in coping etc., complete all as directed.

2

-

-

... More
M&L for construction of brick masonary valve pit of size 60x60x60cm internal dimensions (230mm wall thickness) including mild steel sheet cover 3mm thick over and including angle iron frame of size 40x40x6mm duly painted with 2 coats of synthetic enamel paint over a coat of red oxide primer with locking & fixing arrangement and brick work and all inner sides/bottom of pit shall be plastered with cement mortar (1:4) 15mm and including foundation concrete (1:4:8) type D-2 using stone aggregate 150mm thick, including excavation in soft/loose soil, returning filling, disposal of surplus soil within 50 metre and cement concrete(1:2:4) type B-0 as in coping etc., complete all as directed.

32

-

-

... More
EXTERNAL ELECTRIC SUPPLY

-

-

-

... More
Supply, installation, testing and commissioning of 11 KV 630 Amps outdoor type 20 kA outdoor extensible SF6 gas insulated 4 way floor mounted compact switchgear with copper bus bar consisting of 01 Nos incoming load break switch and 03 Nos outgoing VCBs. The coupling should be at the top of RMU through bolted connection & sleeved busbars covered with insulating boots. All live parts, bus bars, VCB will beenclosed in robotically welded 2.5 mm, thick non ferrite nonmagnetic stainless steel tank filled with SF6 with IP class IP-67, leak rate not less than 0.1% and tested for internal arc 20kA/1 Sec as per latest IEC 62271-200. The unit shall include the following with all necessary standard fittings:- a) Incomer load break switch - 01 No consisting of following:- (i) Manual operated 630 amps load break switch having two position spring assisted. (ii) Integrated line earthing switch with making capacity. (iii) Live cable LED indicators thru capacitor voltage dividers mounted on the bushings. (iv) Resin cast ring core metering CTs. (vii) Digital multi function meter to measure Amps, volts, frequency, PF, KWH, KVAR etc. (viii) Mechnical ON/OFF/Earth/spring charge indication. Note : Cable boxes should be Arc proof with hinged doors interlocked with respective earthing switches. (b) Outgoing VCB - 02 Nos consisting of following:- (i) Manual operated 630 amps Vacuum circuit breaker having two position double spring mechanisum. (ii) Three position disconnector/earthing switch down stream vacuum circuit breaker (iii) Three position single spring mechanism for disconnector/earthing switch. (iv) live cable LED indicators thru capacitor voltage dividers mounted on the bushings. (v) green (ON) / Red (OFF) push buttons to operate load break switch locally. (vi) 3 O/C + 1 E/F self powered numerical protection relay with low and high set for over current and Earth Fault. relay should have facility to display the maximum loaded phase current also. (vii) Resin cast ring core metering CTs. (viii) Resin cast ring core protection CTs. (ix) Digital ammeter to measure Amps. (x) Mechanical ON/OFF/Earth/Spring charge indication. Note:- Cable boxes should be Arc proof with hinged doors interlocked with respective earthing switches. Note:- The testing of RMU after installation to be carried out by SEI.

1

-

-

... More
Supply, installation, testing and commissioning of 11 KV 630 Amps outdoor type 20 kA outdoor extensible SF6 gas insulated 4 way floor mounted compact switchgear with copper bus bar consisting of 01 Nos incoming load break switch and 03 Nos outgoing VCBs. The coupling should be at the top of RMU through bolted connection & sleeved busbars covered with insulating boots. All live parts, bus bars, VCB will beenclosed in robotically welded 2.5 mm, thick non ferrite nonmagnetic stainless steel tank filled with SF6 with IP class IP-67, leak rate not less than 0.1% and tested for internal arc 20kA/1 Sec as per latest IEC 62271-200. The unit shall include the following with all necessary standard fittings:- a) Incomer load break switch - 01 No consisting of following:- (i) Manual operated 630 amps load break switch having two position spring assisted. (ii) Integrated line earthing switch with making capacity. (iii) Live cable LED indicators thru capacitor voltage dividers mounted on the bushings. (iv) Resin cast ring core metering CTs. (vii) Digital multi function meter to measure Amps, volts, frequency, PF, KWH, KVAR etc. (viii) Mechnical ON/OFF/Earth/spring charge indication. Note : Cable boxes should be Arc proof with hinged doors interlocked with respective earthing switches. (b) Outgoing VCB - 02 Nos consisting of following:- (i) Manual operated 630 amps Vacuum circuit breaker having two position double spring mechanisum. (ii) Three position disconnector/earthing switch down stream vacuum circuit breaker (iii) Three position single spring mechanism for disconnector/earthing switch. (iv) live cable LED indicators thru capacitor voltage dividers mounted on the bushings. (v) green (ON) / Red (OFF) push buttons to operate load break switch locally. (vi) 3 O/C + 1 E/F self powered numerical protection relay with low and high set for over current and Earth Fault. relay should have facility to display the maximum loaded phase current also. (vii) Resin cast ring core metering CTs. (viii) Resin cast ring core protection CTs. (ix) Digital ammeter to measure Amps. (x) Mechanical ON/OFF/Earth/Spring charge indication. Note:- Cable boxes should be Arc proof with hinged doors interlocked with respective earthing switches. Note:- The testing of RMU after installation to be carried out by SEI.

6

-

-

... More
Supply, installation, testing and commissioning out door type LT panel board, AC 415 Volt, 3 phase, 4 wire, CPRI approved factory made, floor mounted, cubical type, outdoor, dust proof, fabicated of 3 mm thick CRCA sheet with powder coated rust proof paint and with front and rear opening complete with locking arrangements with keys conforming to IS-8623 and including of bus bar chamber, danger notice board, internal wiring with PVC insulated fire retardant single core cables of copper conductor of suitable size, MS angle iron frame of size 40x40x6mm, grouted in ground/floor with necessary excavation and foundation in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, connecting incoming and out going cable connections with suitable size lugs, nuts, bolts, washers and cable glands etc complete as specified and shall consisting of the following:- ( at Sub Station) (a) 04 strips of aluminium bus bar with insulation colour sleeves of capacity 800 Amp fixed on PVC heat shrinkable insulator heavy duty. (b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No. (c) Amp meter 0-600 Amps, digital type panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size of CTs-01 No. (d) Indicator lamp LED type on all phases (R,Y,B) - 03 Nos. (e) MCCB 630 Amps, 3 phase, 415 Volt, 4 pole, breaking capacity 50 kA rating with adjustable thermal and adjustable magnetic type - 01 No (incoming). (f) MCCB 315 Amps, 3 phase, 415 volt, 4 pole, breaking capacity 35 kA rating with adjustable thermal-magnetic type -02 Nos (outgoing). (g) MCB 63 Amps, TPN, 415 Volt, 'C' series, breaking capacity 10 kA rating -01 Nos with Digital Timer with complete accessories such as three phase, 63 Amps AC 1 duty power contactor with auxiliary contacts, incoming/outgoing cable connectors, fuze unit, Automatic/manual switch, ON/OF push buttons etc. for controlling of street lights for dusk to dawn operation -01 set

1

-

-

... More
Supply, installation, testing and commissioning out door type LT panel board, AC 415 Volt, 3 phase, 4 wire, CPRI approved factory made, floor mounted, cubical type, outdoor, dust proof, fabicated of 3 mm thick CRCA sheet with powder coated rust proof paint and with front and rear opening complete with locking arrangements with keys conforming to IS-8623 and including of bus bar chamber, danger notice board, internal wiring with PVC insulated fire retardant single core cables of copper conductor of suitable size, MS angle iron frame of size 40x40x6mm, grouted in ground/floor with necessary excavation and foundation in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, connecting incoming and out going cable connections with suitable size lugs, nuts, bolts, washers and cable glands etc complete as specified and shall consisting of the following:- ( at Sub panels) (a) 04 strips of aluminium bus bar with insulation colour sleeves of capacity 600 Amp fixed on PVC heat shrinkable insulator heavy duty. (b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No. (c) Amp meter 0-600 Amps, digital type panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size of CTs-01 No (d) Indicator lamp LED type on all phases (R,Y,B) - 03 Nos. (e) MCCB 315 Amps, 3 phase, 415 Volt, 4 pole, breaking capacity 35 kA rating with adjustable thermal and adjustable magnetic type - 01 No (incoming). (f) MCCB 160 Amps, 3 phase, 415 volt, 4 pole, breaking capacity 35 kA rating with adjustable thermal and fixed magnetic type -02 Nos (outgoing). (g) MCCB 63Amps, 4 pole, breaking capacity 25 kA with adjustable thermal and fixed magnetic typ -01 Nos (outgoing).

2

-

-

... More
Supply, installation, testing and commissioning out door type LT panel board, AC 415 Volt, 3 phase, 4 wire, CPRI approved factory made, floor mounted, cubical type, outdoor, dust proof, fabicated of 3 mm thick CRCA sheet with powder coated rust proof paint and with front and rear opening complete with locking arrangements with keys conforming to IS-8623 and including of bus bar chamber, danger notice board, internal wiring with PVC insulated fire retardant single core cables of copper conductor of suitable size, MS angle iron frame of size 40x40x6mm, grouted in ground/floor with necessary excavation and foundation in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, connecting incoming and out going cable connections with suitable size lugs, nuts, bolts, washers and cable glands etc complete as specified and shall consisting of the following:- (LTP to Bldgs) (a) 04 strips of aluminium bus bar with insulation colour sleeves of capacity 400 Amp fixed on PVC heat shrinkable insulator heavy duty. (b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No. (c) Amp meter 0-600 Amps, digital type panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size of CTs-01 No. (d) Indicator lamp LED type on all phases (R,Y,B) - 03 Nos. (e) MCCB 160 Amps, 3 phase, 415 Volt, 4 pole, breaking capacity 25 kA rating with adjustable thermal and fixed magnetic type - 01 No (incoming). (f) MCCB 63 Amps, 3 phase, 415 volt, 4 pole, breaking capacity 25 kA rating with adjustable thermal and fixed magnetic type -04 Nos (outgoing). (g) MCCB 63Amps, 4 pole, breaking capacity 25 kA with adjustable thermal and fixed magnetic typ -01 Nos (outgoing).

4

-

-

... More
Supply, installation, testing and commissioning LT panel board, AC 415 Volt, 3 phase, 4 wire, CPRI approved factory made, floor mounted, cubical type, outdoor, dust proof, fabicated of 3 mm thick CRCA sheet with powder coated rust proof paint and with front and rear opening complete with locking arrangements with keys conforming to IS-8623 and including of bus bar chamber, danger notice board, internal wiring with PVC insulated fire retardant single core cables of copper conductor of suitable size, MS angle iron frame of size 40x40x6mm, grouted in ground/floor with necessary excavation and foundation in PCC 1:2:4 type B-1 using 20mm graded stone aggregate, connecting incoming and out going cable connections with suitable size lugs, nuts, bolts, washers and cable glands etc complete as specified and shall consisting of the following:- (LTP to Bldgs)(a) 04 strips of aluminium bus bar with insulation colour sleeves of capacity 400 Amp fixed on PVC heat shrinkable insulator heavy duty. (b) Volt meter 0-500 volts, digital type, panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch - 01 No. (c) Amp meter 0-200 Amps, digital type panel mounted, flush type, three phase of size 96x96mm complete with built in selector switch with suitable size of CTs-01 No. (d) Indicator lamp LED type on all phases (R,Y,B) - 03 Nos. (e) MCCB 63 Amps, 3 phase, 415 Volt, 4 pole, breaking capacity 25 kA rating with adjustable thermal and fixed magnetic type - 01 No (incoming). (f) MCB 40 Amps, SPN, breaking capacity 10 kA rating, 'C' series - 07 Nos (outgoing). and including providing electronic temper proof energy meter SP, 230 Volts, 40 Amps - 06 Nos with locking arrangement, glass arrangement for taking reading etc

16

-

-

... More
Supply, laying & testing of PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 3 Core, 2.5 Sqmm 1100 volts grade, complete all as directed

160

-

-

... More
S&F Junction box on existing pole of minimum size 300mm x 200mmx150mm made out of 1.6mm thick MS sheet duly painted with 2 coat of synthetic enameled paint over one coat of red oxide, outdoor type, lockable complete with fixing arrangement with 100 Amps capacity aluminium bus bar 4 Nos and One Nos 10 Amps MCB SPN. Including clamps made out of flat iron 25x3mm and nuts, bolts, washer and thimbles etc complete all as directed

20

-

-

... More
Supply and fixing LED endura pluse street light luminaires, 70 watt, 5700k, having assymetric optics, new generation energy saving & environmental friendly long life versatile pressure die-cast aluminium housing IP 66 roadway luminaire with high power LED as light source and electronic driver complete as specified and directed.

20

-

-

... More
DEMOLISHION AND DISMANTALING

-

-

-

... More
Taking down low level Flushing cistern of any type and capacity complete all as dircected.

105

-

-

... More
Taking up or down worn out/damage/unserviceable PVC insulated underground cable armoured, heavy duty with aluminium conductors of any size, 1100V grade from trench/duct/pole/ wall/ pipe/rooftops etc. complete all as specified and directed. Note:-Excavation and earth work shall be measured and paid sparetely under Part-II

650

-

-

... More
Taking down old main switch / MCB DB with MCBs of any type and any size complete all as directed.

101

-

-

... More
Taking down old sub main wiring of any description and size complete all as specified and directed.

460

-

-

... More
Taking down old Tube light fittings/mirror light any typecomplete all as specified and as directed.

200

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.