Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date5 Dec 2023
Closing DateCancelled
Tender Amount₹ 35,00,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for repair/maitenance of washing machine front loading 25 kgs capacity including taking out of internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule.

1

-

-

... More
M&L for repair/maitenance of washing machine front loading 50 kgs capacity including taking out of internal drum, soldering, refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule.

1

-

-

... More
M&L for repair/maitenance of washing machine front loading 100 kgs capacity including taking out of internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule.

1

-

-

... More
M&L for repair/maitenance of washing machine top loading 200 kgs capacity including taking out of internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup and studs of any type etc as per sample all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule.

1

-

-

... More
M&L for repair/maitenance of dry tumbler machine front loading 25 kgs capacity including taking out of internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup, studs and wire mesh in bottom of machine any type etc as per sample all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule.

1

-

-

... More
M&L for repair/maitenance of dry tumbler machine front loading 50 kgs capacitiy including taking out of internal drum, soldering , refix and balancing of internal drum and replacement of bearing, gland, gland cup, studs and wire mesh in bottom of machine any type etc as per sample all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule.

1

-

-

... More
M&L for repair/maitenance of flat bed press including replacement of u/s internal wiring, checking of hydraullic system and other spares required to make press serviceable complete all as specified and directed. Note: Extra spares required other than specified in job shall be measured and paid separately under items of this schedule.

2

-

-

... More
M&L for replacement of existing u/s limit switch 10 Amps, 1 NO + 1 NC, 500 volts as per sample complete all as specified and directed.

4

-

-

... More
M&L for replacement of existing u/s forward/ reverse mechanism of washing machine as per sample complete all as specified and directed.

2

-

-

... More
M&L for replacement of existing u/s ML contactor ML 1.5, 415 volts, 3 phase as per sample complete all as specified and directed.

3

-

-

... More
M&L for replacement of existing u/s ON/ OFF push button, AC 15: 415 V, 4 Amps, DC 13: 110 Volts, DC 0.5 Amps as per sample all as specified and directed.

6

-

-

... More
M&L for replacement of existing u/s Magnetic coil drain switch Type:- SLD, 415 volts, 50 Hz, Max. stroke:- 3.14 MM, Pull:- 6.75 Kg as per sample.

2

-

-

... More
M&L for replacement of existing u/s Electronic timer type ETR D2, 240 volts as per sample.

2

-

-

... More
M&L for replacement of existing u/s Indicators 2XVLIR, 130 Volts, 2.6 W as per sample.

12

-

-

... More
M&L for replacement of existing u/s ML 2 Contactor, 415 volts, 32 Amps as per sample all as specified and directed.

2

-

-

... More
M&L for replacement of existing u/s Electrde suitable for RXA-06 (2000).

2

-

-

... More
M&L for replacement of existing u/s Economiser suitable for RXA-06 (2000). Make Thermax

2

-

-

... More
M&L for replacement of existing u/s ignition tranformer 14 KVA, 440 volts/11 KV. Make Thermax

2

-

-

... More
M&L for replacement of existing u/s Photocell 8205. Make Thermax

2

-

-

... More
M&L for replacement of existing u/s sequence controller MA 810. Make Thermax

1

-

-

... More
M&L for replacement of existing u/s gland washer for triplex pump make as per sample

16

-

-

... More
M&L for replacement of existing u/s valve sheet assembly make as per sample

12

-

-

... More
M&L for replacement of existing u/s triplex pump piston (SP) make as per sample

1

-

-

... More
M&L for replacement of existing u/s sight glass size 50 mm dia and 4 mm thick fire proof make as per sample

2

-

-

... More
M&L for replacement of existing u/s Thermometer 0 to 150 degree centigrade make as per sample

4

-

-

... More
M&L for replacement of existing u/s pressure gauge 0 to 25 Kg/cm, 4 inch dia including back connection make as per sample

2

-

-

... More
M&L for replacement of existing u/s DTC (Digital temperatue controller) controller make as per sample

2

-

-

... More
M&L for replacement of existing u/s limit switch suitable for RXA-6 (2000) make as per sample

2

-

-

... More
M&L for replacement of existing u/s Nozzle 6.5 suitable for RXA-6 (2000) make as per sample

2

-

-

... More
M&L for replacement of existing u/s burner rod assy. Make: Thermax

2

-

-

... More
M&L for replacement of existing u/s steam blow down valve size 20 mm make as per sample

2

-

-

... More
M&L for replacement of existing u/s steam non return valve size 20 mm make as per sample

2

-

-

... More
M&L for replacement of existing u/s metallic brid hose pipe size 3/8 x 36 inch make as per sample

8

-

-

... More
M&L for replacement of existing u/s metallic brid hose pipe size 1/2 x 20 inch make as per sample

4

-

-

... More
M&L for replacement of existing u/s water level pressure switch make as per sample

2

-

-

... More
M&L for replacement of existing u/s steam pressure switch make as per sample

2

-

-

... More
M&L for replacement of existing u/s safety valve 25 mm make as per sample

2

-

-

... More
M&L for replacement of existing u/s electrode cap for burner make as per sample

2

-

-

... More
M&L for replacement of existing u/s RTD assy make as per sample.

2

-

-

... More
M&L for replacement of existing u/s super heater as per sample all as specified and directed.

4

-

-

... More
M&L for replacement of existing u/s asbestos teflon rope size 10 mm or required and directed.

4

-

-

... More
M&L for replacement of existing u/s asbestos teflon rope size 5 mm or required and directed.

2

-

-

... More
M&L for replacement of existing u/s cemented plaster with white cement complete all as specified and directed.

50

-

-

... More
M&L for replacement of existing u/s door gasket of washing machines of size and capacities 25/50/100/200 Kgs, drying tumbler 25/50 kgs as per sample all as specified and directed.

10

-

-

... More
M&L for replacement of existing u/s spring for hydraullic extractor 25 kgs capacity as per sample all as specified and directed.

2

-

-

... More
M&L for replacement of existing u/s spring for hydraullic extractor 50 kgs capacity as per sample all as specified and directed.

2

-

-

... More
M&L for replacement of existing u/s bronze steam valve 15 mm, ISI marked as per sample.

2

-

-

... More
M&L for replacement of existing u/s bronze steam valve 20 mm, ISI marked as per sample.

5

-

-

... More
M&L for replacement of existing u/s bronze steam valve 25 mm, ISI marked as per sample.

5

-

-

... More
M&L for replacement of existing u/s bronze steam valve 40 mm ISI marked as per sample.

4

-

-

... More
M&L for replacement of existing u/s bronze steam valve 50 mm ISI marked as per sample.

3

-

-

... More
M&L for ball valve 50 mm dia gun metal as per sample.complete all as specified and directed. Make :Minar

4

-

-

... More
M&L for multiport valve for water softening plant make as per sample

1

-

-

... More
M&L for replacement of existing u/s V- Belts size B-65 complete all as specified and directed.Make: Speed,Fenner,Dunlop,Nirlon.

10

-

-

... More
M&L for replacement of existing u/s V- Belts size B-101 complete all as specified and directed.Make: Speed,Fenner,Dunlop,Nirlon.

10

-

-

... More
M&L for replacement of existing u/s V- Belts size B-71 complete all as specified and directed.Make: Speed,Fenner,Dunlop,Nirlon.

10

-

-

... More
M&L for replacement of existing u/s V- Belts size B-108 complete all as specified and directed.Make: Speed,Fenner,Dunlop,Nirlon.

15

-

-

... More
M&L for replacement of existing u/s V- Belts size B-78 complete all as specified and directed. Make: Speed,Fenner,Dunlop,Nirlon.

10

-

-

... More
M&L for replacement of existing u/s V- Belts size B-124 complete all as specified & directed by Engr-in-charge.Make: Speed,Fenner,Dunlop,Nirlon.

10

-

-

... More
M&L for replacement of existing u/s V- Belts size B-120 complete all as specified and directed. Make: Speed,Fenner,Dunlop,Nirlon.

10

-

-

... More
M&L for replacement of existing u/s V- Belts size A-56 complete all as specified and directed. Make: Speed,Fenner,Dunlop,Nirlon.

6

-

-

... More
M&L for rewinding of existing unsv 3 Phase, 0.5 HP/ 0.37 KW , 50 Hz, 2800 RPM induction motor any make with super enameled copper winding wire of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threading and making all electric connections including taking out and refixing at site all as specified and directed.

2

-

-

... More
M&L for rewinding of existing unsv 3 Phase, 2 HP/ 1.5 KW , 50 Hz, 2820 RPM induction motor any make with super enameled copper winding wire of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threading and making all electric connections including taking out and refixing at site complete all as specified and directed.

1

-

-

... More
M&L for rewinding of existing unsv 3 Phase, 5 HP/ 3.75 KW , 50 Hz, 2800 RPM induction motor any make with super enameled copper winding wire of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threading and making all electric connections including taking out and refixing at site all as specified and directed.

1

-

-

... More
M&L for rewinding of existing unsv 3 Phase, 10 HP/ 7.46 KW , 50 Hz, 2800 RPM induction motor any make with super enameled copper winding wire of gauge as per existing including cutting and getting out old US winding, sleeve work, varnishing with E class insulation varnish , threading and making all electric connections including taking out and refixing at site all as specified and directed.

1

-

-

... More
M&L for replacement of existing un-serviceable/ perished metallic wheels with outer cover of cloth trollies including welding/ fabrication and testing on load complete all as specified and directed.

6

-

-

... More
M&L for welding / fabrication to the exsting u/s equipment of the machinery for re-strengthing to the existing assests including replacement of angle iron any size, channel, flat iron, MS sheet, nut, bolt and washers etc complete all as specified and directed.

4

-

-

... More
M&L for replacement of radiator of dry tumbler machine front loading 50 kgs capacity including soldering, brazing etc complete all as specified and directed.

1

-

-

... More
M&L for replacement of radiator of dry tumbler machine front loading 25 kgs capacity including soldering, brazing etc complete all as specified and directed.

1

-

-

... More
Taking out the old unserviceable radiator from the dry tumbler machine front loading 50 kgs capacity and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc complete all as directed.

1

-

-

... More
Taking out the old unserviceable radiator from the dry tumbler machine front loading 25 kgs capacity and taking it to work shop for overhauling & cleaning descaling with restore plus solution, removal of leakage, welding brazing & refixing it duly repaired etc complete all as directed.

1

-

-

... More
M&L for replacement of old u/s MCB four pole with RCCB four pole 40 amps, with 100 mA sensitivity, 415 volts complete all as specified and directed.

2

-

-

... More
M&L for replacement of old u/s MCB four pole with RCCB four pole 63 amps, with 100 mA sensitivity, 415 volts complete all as specified and directed.

2

-

-

... More
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 40 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.

50

-

-

... More
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 50 mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.

30

-

-

... More
Supply and laying of HDPE DWC (Double wall corrugated) pipe of 77mm bore outer dia laid for protection of cables in trenches, floors complete all as specified and directed.

50

-

-

... More
M&L in replacement of Sub main wiring in two single run FRLS PVC insulated cable 4 Sqmm (Nominal dia) copper conductor (multistrand) and drawing in and including new PVC concealed non metallic conduit pipe ISI marked including one run 4 Sqmm multistranded copper conductor FRLS PVC green colour insulated unsheathed cable for earth continuity complete all as spd and directed.

30

-

-

... More
M&L in replacement of Sub main wiring in two single run FRLS PVC insulated cable 6 Sqmm (Nominal dia) copper conductor (multistrand) and drawing in and including new PVC concealed non metallic conduit pipe ISI marked including one run 6 Sqmm multistranded copper conductor FRLS PVC green colour insulated unsheathed cable for earth continuity complete all as spd and directed.

30

-

-

... More
M&L for replacement of Existing u/s GI water tubing medium grade 15 mm dia including all fittings required at site complete all as specified and directed.

10

-

-

... More
M&L for replacement of Existing u/s GI water tubing medium grade 20 mm dia including all fittings required at site complete all as specified and directed.

20

-

-

... More
M&L for replacement of Existing u/s GI water tubing medium grade 25 mm dia including all fittings required at site complete all as specified and directed.

20

-

-

... More
M&L for replacement of Existing u/s GI water tubing medium grade 40 mm dia including all fittings required at site complete all as specified and directed.

20

-

-

... More
M&L for replacement of Existing u/s GI water tubing medium grade 50 mm dia including all fittings required at site complete all as specified and directed.

20

-

-

... More
M&L for replacement of Existing u/s GI water tubing medium grade 80 mm dia including all fittings required at site complete all as specified and directed.

20

-

-

... More
M&L, pouring for replacement of Gear oil of laundary machinary as per sample complete all as specified and directed.

10

-

-

... More
M&L in replacement of old u/s sheet metal enclosure MCB distribution board with thermoplastic polycarbonated MCB enclosure which is shock, rust, dust, impact and water proof , halogen and silicon free, UV resistant with internally embedded gasket high grade made of polyurethene. The thermoplastic enclosure suitable size with degree of protection IP-65 DBs double door type for MCBs 05 Modules including PE+N trminals link all as spd. Make:- Hensal / ABB/ Legrand.

4

-

-

... More
M& L for sparay painting to the outer surface of existing complete machienry of laundary plant and its connected accessories with acrylic synthetic enamell paint of approved colour including. preperation/ rediness of the surface for the painting purpose by means of rubbing / scraping the old and rusted surfaces of the equipment and the machinery all as specified and directed.

1

-

-

... More
M&L for replacement of existing unsv earthing with steel earth plate electrode of size 60x60cmx6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron strip of size 32x6mm as earthing lead by means of nuts, bolts and washers of steel after welding of GI strip to earth electrode to the full lenght of earth plate,40mm dia GI tubing light grade protection pipe upto test point, 20mm dia GI watering pipe with funnel and wire mesh, PCC pit 1:3:6 with pit cover of size 30X30cm made of RCC 1:3:6 with suitable handle,angle iron frame made of angle iron of size 40x40x4mm, adequate qty of charcoal dust and salt layers all around the earth plate, removal of surplus soil and returning filling in all as required at site including test point made out of steel plate of size 75x75x6mm fixed to wall all as specified in plate No 3 of SSR Part-I and directed.

5

-

-

... More
Testing of dielectric strength of transformer oil for indoor type Stabilizer of capacity 30 kva to 500 kva,433 V, filteration of transformer oil by passing through filtration plant to remove moisture, impurities and improving di-electic strength to above 40 KV for 1 minute including new transformer oil for toping up & testing after filtration complete as specified. (Note: Transformer oil will be measured & paid seperately.)

2500

-

-

... More
Repair/Replacement of servo stabilizer circuit card (PCB) suitable for three phase stabilizer 30 KVA to 50 KVA as per existing all as specified and directed

3

-

-

... More
Repair/Replacement of servo stabilizer circuit card (PCB) suitable for three phase stabilizer 100 KVA as per existing all as specified and directed

2

-

-

... More
Repair/Replacement of servo stabilizer circuit card (PCB) suitable for three phase stabilizer 500 KVA as per existing all as specified and directed

1

-

-

... More
Repair/Replacement of servo stabilizer multi fuctional meter suitable for three phase stabilizer 30 KVA to 50 KVA as per existing all as specified and directed

1

-

-

... More
Repair/Replacement of servo stabilizer multi fuctional meter suitable for three phase stabilizer 100 KVA as per existing all as specified and directed

1

-

-

... More
Repair/Replacement of servo stabilizer multi fuctional meter suitable for three phase stabilizer 500 KVA as per existing all as specified and directed

1

-

-

... More
Repair/Replacement of servo stabilizer motor upto 10 KG with RC suitable for three phase stabilizer 30 KVA to 100 KVA as per existing all as specified and directed

1

-

-

... More
Repair/Replacement of servo stabilizer motor upto 15 KG with RC suitable for three phase stabilizer 500 KVA as per existing all as specified and directed

1

-

-

... More
Repair/Replacement of servo stabilizer Dimmer as per existing for three phase stabilizer 30 KVA to 50 KVA as per existing all as specified and directed

1

-

-

... More
Repair/Replacement of servo stabilizer Dimmer as per existing for three phase stabilizer 100 KVA/500 KVA as per existing all as specified and directed

1

-

-

... More
Repair/Replacement of transformer for servo stabilizer as per existing upto 50 KVA as per existing complete all as specified and as directed.

1

-

-

... More
Repair/Replacement of transformer for servo stabilizer as per existing 100 KVA as per existing complete all as specified and as directed.

1

-

-

... More
Repair/Replacement of transformer for servo stabilizer as per existing 500 KVA as per existing complete all as specified and as directed.

1

-

-

... More
M&L for scrapping out old painted surfaces of 30 to 250 KVA servo stabilizer,APFC panel and making smooth exposed surfaces and applying two coat of synthetic enamel paint (smoke gray shade) over a coat of red oxide primer complete all as specified and directed.

15

-

-

... More
Supply and toping of transformer oil with 40KV di-electric strength Transformer and Servo voltage stabilizer .Oil shall conform to IS 335 of 1993. complete all as specified and directed.

300

-

-

... More
Supply and Repair/Replacement of MCB SP 6-32 Amps, 10 KA breaking capacity , 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.

20

-

-

... More
Supply and Repair/Replacement of MCB SPN 6-32 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.

20

-

-

... More
Supply and Repair/Replacement of MCB SPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.

5

-

-

... More
Supply and Repair/Replacement of MCB TPN 40 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge.

10

-

-

... More
Supply and Repair/Replacement of MCB TPN 63 Amps, 10 KA breaking capacity 230 V, 50 Hz AC Supply complete all as specified and directed by Engineer - in - Charge

5

-

-

... More
Taking down defective street light fitting of any size/ type/ capacity from height of pole/walls/high mast of any location exceeding 7.0 m height for repair work and re-fixing back after repair work including checking, inspecting, testing and commmissioning complete all as directed by Engr-in-Charge. Note:a) The M/L for Items like lamp, electronic drivers,surge protection devices etc shall be measured and paid separately under relevant items here in under this Schedule. b) Necessary tools like ladders & other T&P required etc shall be arranged by the Contractor. c) The rate quoted deemed to be inclusive for minor parts nut bolts, circle clips, clamps etc if any required at site.d) The M/L for repairs to LED panel is not included in the scope and shall be measured and paid separately.

150

-

-

... More
S&F in repair Electronic digital Timer (Astronomical) suitable for street light timer DB panels .

3

-

-

... More
Supply only the following spares suitable for LED street/Flood light fittings of

-

-

-

... More
Electronic driver potted type IP-65, suitable for 90 to 120 W LED light fitting

50

-

-

... More
Electronic driver potted type IP-65, suitable for 70 to 80 W LED light fitting

50

-

-

... More
Electronic driver potted type IP-65, suitable for 30 to 60 W LED light fitting

50

-

-

... More
Surge protection device of capacity 10 KV suitable for LED light fitting

100

-

-

... More
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 100 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

5

-

-

... More
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 60 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

5

-

-

... More
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 4500 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 45 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

5

-

-

... More
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 6000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 60 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

5

-

-

... More
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED “inverter type bldg security light fittings with inbuilt battery backup for min 3 to 4 hrs, comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) Min 72 watt roadway lumanarie type with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. . Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

5

-

-

... More
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 5000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 50 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

5

-

-

... More
Taking down old unserviceable security light fittings roadway lumanarie type from any height and Supply & fixing LED security light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 7200 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 72 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed. Note: The GI pipe bracket if required will be measured and paid separately under relevant schedule items

10

-

-

... More
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 12000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 150 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.

10

-

-

... More
Taking down old unserviceable street light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 15000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 90 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.

10

-

-

... More
Taking down old unserviceable flood light fittings from any height and Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame,(with total lumen output not less than 20000 lumens and suitable wattage for efficiency not less than 100 lumens/Watt) min wattage 200 watt, with ingress protection IP 65/66 and SPD of capacity 10 KV etc incl necessary clamps etc complete and testing on completion all as specified and as directed.

5

-

-

... More
Dismantling old un-serviceable flood light fittings from any position exceeding 7.5 m height, Supply & fixing LED flood light fittings comprising of epoxy powder coated housing, enclosed with glass cover in frame LED type (with total lumen output not less than 10000 lumens and suitable wattage for efficiency not less than 100 lumens/ Watt) min wattage 100 watt, with ingress protection IP 65 and surge protection device of 10 KV capacity etc incl necessary, angle iron supports , clamps etc complete and testing on completion all as specified and as directed

5

-

-

... More
S&F replacement decorative path way light lighting LED decorative post top lantern for 360 degree 40 watts 230 volts, 50 HZ, maple shaped in sothing opal/ prismatic finish made up of polycarbonate, including all accessories prewired complete.Note :- (i) Minimum 2 years gaurntee period of LED fittings (ii) Driver shall be IP 66 degree of protection potted seal type. (iii) Power factor more than 0.9

10

-

-

... More
Supply and erect steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.0 metres long) all as directed incl dismantling old one.Make: Utkarsh Bansal/ National tubing Co/Jindal/Electrosteel. NOTE :- Earth work, Cement concrete in foundation, coping etc will be measured and paid separately under relevant item.

5

-

-

... More
S&F in repair PVC insulated 3 core 2.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.

50

-

-

... More
S&F in repair PVC insulated 3 core 1.5 Sq mm stranded Aluminium conductor cable for connecting OH line/junction box to street light fitting testing and commissioning all as directed.

50

-

-

... More
M&L for PCC 1:4:8 type D2 with 40 mm graded aggregate as in foundation complete.

2.25

-

-

... More
M&L for PCC 1:3:6 type C1 with 20 mm graded aggregate for coping of poles and stay including form work.

2.25

-

-

... More
S&F timelite distribution boards (street light DBs) 40 A 3 pole with 230 V Astronomical time switch complete all as directed including dismantling old one .

2

-

-

... More
S&F loop-in/loop-out box of outer size size 250x210x115 mm made out of FRP(Hot moulded type) with weather proof canopy and locking screws along with with 5/6 Amps MCB - 01 No, 50 Amps rated 3 pole connector- 01 Nos, neutral link mounted and Din rail suitable size for mounting MCB/Connector etc complete in the box, duly fixed to to steel tubular/rail/PCC/RCC pole using 25 x 3mm FI clamp, including suitable gland and lugs for connecting cable complete all as directed including dismantling old one.

70

-

-

... More
Excavation in trenches in any type of soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.

121

-

-

... More
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.

55

-

-

... More
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.

66

-

-

... More
M&L for good quality dry sand cushioning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule part-I (2009) Note : Sand shall be fined sand as specifed and punned thickness shall be measured and paid.

48

-

-

... More
Supply and laying sub class 'B' bricks of old size (230x115x75 mm) or of size locally available, laid along alignment of cable as protection to cable in trenches complete all as specified and directed.

4800

-

-

... More
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 25 Sqmm 3.5/4 core to 300 Sqmm 3.5 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule

200

-

-

... More
Removing existing 1100 volts grade, XLPE/PVC, armoured, electric power cables (heavy duty) with aluminium conductor of sizes 6 Sqmm 4 core to 16 Sqmm 4 core from trench/ duct/ pipe carefully for identifying the defects and relaying the same after rectification of defects complete all as directed. Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule

200

-

-

... More
Supply and lay cable XLPE insulated armoured heavy duty electric cable with aluminium counductor, 1100 volts grade of crosssectional area 16 Sq mm 4 core.Note: Earth work ( Excavation, Returning & refilling and removal), sand cushining , cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Schedule

150

-

-

... More
All as per Item No. 146 above but of size 10 Sqmm 4 core

100

-

-

... More
All as per Item No. 146 above but of size 25 Sqmm 4 core

100

-

-

... More
All as per Item No. 146 above but of size 35 Sqmm 3.5 core

150

-

-

... More
All as per Item No. 146 above but of size 50 Sqmm 3.5 core

100

-

-

... More
All as per Item No. 146 above but of size 70 Sqmm 3.5 core

100

-

-

... More
All as per Item No. 146 above but of size 95 Sqmm 3.5 core

100

-

-

... More
All as per Item No. 146 above but of size 120 Sqmm 3.5 core

100

-

-

... More
All as per Item No. 146 above but of size 240 Sqmm 3.5 core

80

-

-

... More
S&F PVC insulated copper conductor cable 10 Sq mm x 3 core for main Panel to main switch/starter,MCCB etc complete with thimbales of suitable size as required on site all including making connection all as specifed and directed by Engr-in-Charge

30

-

-

... More
S&F PVC insulated copper conductor cable 16 Sq mm x 3 core for main Panel to main switch/starter,MCCB etc complete with thimbales of suitable size as required on site all including making connection all as specifed and directed by Engr-in-Charge

30

-

-

... More
S&F PVC insulated submersible copper conductor cable 10 Sq mm x 3 core for main Panel to main switch/starter/pump,MCCB etc complete with thimbales of suitable size as required on site all including making connection all as specifed and directed by Engr-in-Charge

30

-

-

... More
Supply and Repair/Replacement of laying/jointing GI Pipe light grade 40mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.

30

-

-

... More
Supply and Repair/Replacement of laying/jointing GI Pipe light grade 80mm dia with all fittings laid/fixed on wall/pole or under road/PCC crossing and all as specified and directed.

20

-

-

... More
M&L for Horizontal Boring/Cutting of Road/Foot Path for using through 40/80mm bore pipe for cable protection and finishing PCC after Boring/Cutting of road/Foot path, complete all as specified and as directed.

20

-

-

... More
Supply and Repair/Replcement for weather proof flat twin core 6 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
Supply and Repair/Replacement for weather proof flat twin core 10 sqmm multistrand aluminium conductor cable complete all as specified and directed by Engineer-in-Charge.

100

-

-

... More
M&L for fault finding on LT cables of any size and any length with fault detective machine by thumbing method/other suitable find out method with suitable high voltage and all as and directed by Engineer-in-charge.

10

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 sqmm to 50 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 10 sqmm to 16 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for Stright through joint heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to150 sqmm complete all as specified and directed Engr-in-Charge.

5

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 70 sqmm to150 sqmm complete all as specified and directed Engr-in-Charge.

30

-

-

... More
S&F of Cable jointing kit for 1100 V (Earthed) grade cable for INDOOR / OUTDOOR END TERMINATIONS heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete all as specified and directed Engr-in-Charge.

20

-

-

... More
Supply and Repair/Replacement fixing Lug aluminium suitable cable size of 16 to 95 sqmm complete all as specified and directed Engineer-in-Charge.

200

-

-

... More
Supply and Repair/Replacement fixing Lug aluminium suitable cable size of 120 to 400 sqmm complete all as specified and directed Engineer-in-Charge.

150

-

-

... More
Supply and Repair/Replacement of industrial change over switch gear 200 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
Supply and Repair/Replacement of industrial change over switch gear 100 Amp 415 V Four Pole Off Load Side Handle Operated In Sheet enclosure, Powder Coated, Weather proof conforming to IS: 13947 by connecting the electrical connection and fixing on wall or panel with clamp nut, bolt etc complete all as specified and as directed by Engr-in-Charge.

2

-

-

... More
Supply and Repair/Replacement for 800 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement for 400 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repair/Replacement for 250 AMP MCCB, 4 pole 415 volt, AC 50 Hz, 4 pole, 36 KA with adjustable thermal and magnetic tripping system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

2

-

-

... More
Supply and Repair/Replacement for 63 AMP MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

2

-

-

... More
Supply and Repair/Replacement for 100 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

2

-

-

... More
Supply and Repair/Replacement for 125 AMP, MCCB 4 pole 415 volt, AC 50 Hz, 4 pole, 10 KA with adjustable thermal and fixed magnetic setting system against over load and short circuit conditions incl neutral adjustment suitable of Existing panel board for replace of unserviseble MCCB complete all as specified and directed.

1

-

-

... More
Supply and Repeir/Replacement of panel mounted volt meter digital type 3 phase as per existing complete all as specied and directed

5

-

-

... More
Repeir/Replacement of panel mounted Ammeter digital type 3 phase as per existing complete all as specied and directed

5

-

-

... More
Taking out any damage of the already installed LT panel board doors/shutter and repair the broken doors by putting necessary nut,bolts,hinges,screw,welding etc and fix it again on the same panel board with two coats of synthetic enamel paint of existing colour complete upto 5 sqm complete all as specified and directed.

10

-

-

... More
Taking out any damage of the already installed LT panel board doors/shutter and repair the broken doors by putting necessary nut,bolts,hinges, welding etc and fix it again on the same panel board with two coats of synthetic enamel paint of existing colour complete exc 5 sqm n exec 10 sqm complete all as specified and directed.

10

-

-

... More
Dismantling the defective LT UT cable 3.5/ 4 core from panel/DB/junction boxes, dismentling the cable gland if any, removing the pitted/burnt aluminium lugs and suplly and fixing of aluminium paim type lugs or lugs as per existing, crimping with suitable size crymping tool bit, refixing/ replacing cable gland, refixing the cable with suitable nut bolts & washers etc complete for the following size cable:- (Note:(i) one set of triple pole and neutral lugs will be measured as one job. (ii) The rate quoted deemed to be inclusive of insulation tape, nut bolts & washers etc complete. (iii)cable gland will be measured and paid separately.(iv) The rate quoted deemed to be inclusive the necessary earth work for removing loop of cable if any required complete all as directed

-

-

-

... More
All as per Item No. 184 above but of size 25/35 sqmm

15

-

-

... More
All as per Item No. 184 above but of size 50/70 sqmm

10

-

-

... More
All as per Item No. 184 above but of size 70/95 sqmm

10

-

-

... More
All as per Item No. 184 above but of size 120/150 sqmm

10

-

-

... More
All as per Item No. 184 above but of size 240/300 sqmm

5

-

-

... More
M&L for painting to steel tubular pole 9.00/11.0 metre long with one coat of red oxide on pole and two coats of synthetic enamel paint up to 1.20 metre height from ground level in 30 cm alternative black and yellow strips and remaining portion with two coats of aluminium paint complete all as specified and directed by Engineer-in-Charge

150

-

-

... More
M&L for numbering of pole no. Using stensils with two coats of Black round and fonts with white in colour complete all as specified and directed by Engineer-in-Charge.

250

-

-

... More
S&F in replacement on pole street light bracket fabricated out of GI Tubing light grade 40 mm bore Bend to the shape as directed and of length 1.5 mtr complete with mounting MS clamp of flat iron of suitable size 02 Nos incl nut bolts Etc of suitable size all as specified and directed by Engr In charge

15

-

-

... More
Supply and Repair/Replacement of decorative gate light moon (opal) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and fixing on existing 40/50 mm pole dia with 7 watt LED lamp complete all as specified and direcred by Engineer-in-Charge

10

-

-

... More
Supply and Repair/Replacement of decorative gate light MUSHROOM (PRISMATIC) type made up of high grade unbreakeble polycarbonate material suitable for retrofit B22 base and fixing on existing 40/50 mm pole dia with 7 watt LED lamp complete all as specified and direcred by Engineer-in-Charge

10

-

-

... More
Supply and Repair/Replacement of decorative gate light Lexo (Prismatic) made up of high grade unbreakeble polycorbonate material suitable B22 Base and upto 60 mm pole dia with 10 watt LED lamp coplete all as specified and directed by Engineer-in-Charge

10

-

-

... More
Supply and Repair/Replacement of new generation post top energy saving environmental friendly,long life aesthetically designed with symmetrical light distribution,spun aluminium landscape luminaire with high power LED as light sourse Coral (opal) - IP65 suitable for pole dia 76 mm with 25 watt LED lamp complete all as specified and directed.

20

-

-

... More
Supply and Repair/Replacement of Building street light fitting Endura pearl 25W LED lamp new genaration energy saving & environmental friendly long life made up of pressure die-cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP65 protection and impect resistance of IK07,with suitable of GI pipe (light grade) bracket and clamps,nut bolts are fixed on wall/post and all as required and directed

10

-

-

... More
Cleaning/desludging of raw sewage in under ground collection sump well up to the depth 7 mtr installation by closing main incoming manhole and pumping out raw sewage to neat drain by using portabale non clog pump set, cleaning of raw sewage sump by manually or mechanically using (spl T&P such as movable sewage cleaning tanker) scrapping inside wall and bottom by steel wire bush to remove raw material and transport it to outside cantonment area for disposal at low lying area up to the distance of 10 Kms at his own arrangment where the sanitary hazard do not take place and as per guidelines of civil authority all as directed for disposal. Thereafter cleaning/washing of interior surface of UG sump using high grade bleaching powder and lime mixed water incl painting with two coat of cement based paint.

2

-

-

... More
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 32 to 40 Amps complete including control wiring thimbles etc complete all as directed.

2

-

-

... More
S & F in repair 3 pole power contactor with coil voltage 230 volt AC of current carring capacity 40 to 100 Amps complete including control wiring thimbles etc complete all as directed.

2

-

-

... More
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 320 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 250 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.

1

-

-

... More
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 200 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 160 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.

1

-

-

... More
Dismentling old feeder pillar & Supply, installing, testing and commissioning of LT feeder pillar box factory made cubicle outdoor type, fabricated out of 3.00 mm thick CRCA sheet floor mounted with angle iron base frame made of 40 x 40 x 6mm , 50 cm height, floor mounted duly bolts and nuts grouted, dust and vermine proof, suitable for voltage 415 V 3 Phase 4 wire ,Square copper bus bar Chamber 160 Amp Capacity weather proof, with IP-54 protection, with separate hinge door for each compartment for incoming and outgoing MCCB etc with locking arrangement, with back door openable (Screwed), legs grouted in PCC complete including painting with two coats of epoxy powder paint over a coat of primer complete including supply fixing and making provision of the following :- (a) MCCB 4 pole 415 volts 3 phase 100 Amp 25 KA -01 No (f) LED Indicator RYB -01 Set ( Set of three). Note: The panel shall be as per CPRI certificate. Note : PCC will be measured and paid separately.

2

-

-

... More
Dismantling unserviceable valves and Supply, fixing,testing and commissioning of butterfly valves incl cutting, welding etc complete all as directed.

-

-

-

... More
All as per Item No. 204 above but of size 50 mm bore

1

-

-

... More
All as per Item No. 204 above but of size 80 mm bore

1

-

-

... More
M&L for dismantling the defective induction motor of any make & capacity 3 HP to 5 HP , any duty or any class of insulation from the bed, duly coupled with pump/ motor transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts complete all as directed: Notes: (i) Motor removed for re-winding shall be overhauled completely and quoted rate is inclusive for the same.

4

-

-

... More
M&L for dismantling the defective induction motor of any make & capacity 7.5 HP to 10 HP , any duty or any class of insulation from the bed, duly coupled with pump/ motor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts complete all as directed: Notes: (i) Motor removed for re-winding shall be overhauled completely and quoted rate is inclusive for the same.

1

-

-

... More
M&L for dismantling the defective sewage non clog submersible motor of any make & capacity 15 HP from sewage well/sump, any duty or any class of insulation from the bed, duly coupled with pump/ compressor, transporting to workshop, removing burnt out winding from stator/ rotor, rewinding with suitable gauge of super enamelled copper wire of approved make and replacing drive end and non drive end bearings, insulation materials, varnishing, heating, re-assembling, testing and commissioning of the following capacities including replacing base frame bolts & nuts and refixing the same as sewage sump complete all as directed: Notes: (i) Motor removed for re-winding shall be overhauled,dismandling and refixing completely and quoted rate is inclusive for the same.

2

-

-

... More
Repair/Replacement of Fe 410-W (Gde E- 250) for Room/Power Room Duct Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy racket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc

200

-

-

... More
S&F of 2.5 Sqmm 10 core copper cable for syncronosing at panel to Dg/panel complete all as specified and as directed.

30

-

-

... More
M & L Repair/Replacement of Aluminium bus bar suitable amp capacity for existing panel complete all as specified and as directed.

50

-

-

... More
M&L for carrying out servicing & maintenance of UPS of capacity upto 20 KVA of Make : M/s SUKAM/Delta by strip opening of UPS, inspection/ servicing of all spare parts such as Drive cards, relay cards, Ac capacitors, inverter cooling fan, ceramic fuses, batteries and including replacing the defective spares if any complete, ressembling, calibration of UPS complete and testing & commissioning complete all as directed. Note : Major Spares such as Inverter Card/ Rectifier Card, AC/DC capacitors, replacement of Batteries required will be measured & paid separately under relevant Schedule. All other spares required for rectifier & inverter section such as other connecting cards, Input fuses, SCR, Inverter cooling fan etc for keeping the UPS in operational state are deemed to be included in the quoted rate.

3

-

-

... More
Supply only the following spares for carrying out repairs to UPS of capacity upto 20 KVA of under item No.213 above. Note : (from 215 to 219 as below)

-

-

-

... More
Inverter card

2

-

-

... More
Rectifier Card

2

-

-

... More
AC capacitor

2

-

-

... More
DC capacitor

2

-

-

... More
12 V 42 AH SMF batteries Make: Amaron /Exide /Panasonic/SF/TATA GREEN

20

-

-

... More
Dismatling, repairing & refixing of of the following damaged/burnt components with new components of 48V DC 150 Amps SMPS power plant including testing complete all as specifed and directed by Engr-in-Charge. Note : (from 221 to 224 as below)

-

-

-

... More
SMPS controller with its daughter cards

1

-

-

... More
48V SMPS modules

3

-

-

... More
Control supply

2

-

-

... More
Surge protection cartridge

4

-

-

... More
Supply and Repair/Repacement of 12 Volt 42 ah battary for UPS as per existing complete all as specified and as directed.

12

-

-

... More
Supply only (Calcium based granular disinfectant for water treatment, more stable than Chlorine Gas, and stronger than bleachingpowder, and sodium Hypochlorite) with chlorine content 65 to 70 % , packing in 45 kg drum complete all as specified and directed by Engr-in-Charge.

120

-

-

... More
Supply only stable bleaching power (SBP)(Calcium hypochloride)Grade I,availabilty Chlorine 34 % min,Stability 1/15 Max,moisture 0.3% max etc all as per IS.

10

-

-

... More
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof/fall ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.

25

-

-

... More
Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account.

-

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.