Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 50,000Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_666372_1Tender No
GE/JAL(W)-30/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
... More
Surface excavation exc. 30 cm deep and averaging 25cm deep and getting out soft/loose soil as in sattled soil/waste materials from drain and thrown away as directed by Engr in Charge.
100
-
-
... More
Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation etc for shafts, wells, cesspits , manholes pier holes, etc n exc 10 sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
600
-
-
... More
Ditto as per description of item No 5 above but for depth exc 1.5m and not exc 3m beyond the first 1.5m depth
100
-
-
... More
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cms in soft /loose soil.
500
-
-
... More
Removing excavated material n exc 50 m depositing where directed at a level n exc 1.5m above the starting point complete all as spd.
200
-
-
... More
Demolition and breaking up drain pipes 150mm bore (salt glazed ware, AC or Reinforced) set in cement mortar all as spd and directed
700
-
-
... More
Demolition and breaking up drain pipes 200 mm bore (salt glazed ware, AC or Reinforced) set in cement mortar all as spd and directed
400
-
-
... More
M &L for 150mm bore SGSW drain pipe (Grade-A) laid in trenches and jointed in CM 1:1 over and including concrete bed in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under,haunching against the sides of pipes after they are laid and tested complete all as spd and directed
700
-
-
... More
M &L for 200mm bore SGSW drain pipe (Grade-A) laid in trenches and jointed in CM 1:1 over and including concrete bed in PCC 1:4:8 type D-2 (using 40 mm graded stone aggregate) to drain pipes including packing under,haunching against the sides of pipes after they are laid and tested complete all as spd and directed
400
-
-
... More
Dismantling up to 100 dia cast iron/PVC pipe or reinforced concrete drain pipes, jointed in cement motar and taking out of trenches , if required.
200
-
-
... More
S&F PVC (SWR) pipes single socketed in any length with rubber joints fixed in trenches 110 mm bore fixing in repair
10
-
-
... More
S&F PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall 110 mm bore fixing in repair
100
-
-
... More
S&F in replacement PVC (SWR) bend/shoe of any radius for 110mm bore pipes complete all as specified.
20
-
-
... More
S&F in replacement PVC (SWR)PVC (SWR) vent cowl for 110mm bore pipes complete all as specified.
10
-
-
... More
S&F PVC (SWR) pipes single socketed in any length with rubber joints fixed to wall 75 mm bore fixing in repair
90
-
-
... More
S&F in replacement PVC (SWR) bend/shoe of any radius for 75mm bore pipes complete all as specified.
10
-
-
... More
Demolition of brick work built in cement mortar including all quoins, arches, pillar etc, but excluding ashlar facings complete all as specified and directed by Engr-in-Charge.
113.45
-
-
... More
Material and labour for brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6m mean radius with old size bricks built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge
95
-
-
... More
M&L brickwork with subclass `B' bricks straight or curved on plan exc 6 m mean radius built in CM 1:6 but except bricks
15
-
-
... More
M&L for brick work in half brick thick walls built in cement mortar (1:4) using sub class ‘B’ old size bricks, straight or curved on plan to any radius complete all as specified.
30
-
-
... More
Taking down cement or cement lime plaster any description on brick walls etc. including racking out joints hacking for keys scrubbing down with water.
1000
-
-
... More
M&L rendering 15 mm thick in CM 1:4 on brick work including finishing the surface fair and even without using extra cement.
1500
-
-
... More
Demolition of cement concrete (unreinforced) in concrete of any description and in any position not otherwise specifically provided for all as specified and directed
18
-
-
... More
M&L for PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate ) as in foundation filling, mass concrete etc complete all as specified.
6
-
-
... More
M&l for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in surface channels and drains complete all as specified and directed by the Engineer in Charge.
12
-
-
... More
M&L for Plain Cement Concrete Type B0 1:2:4 using 12.5 mm graded aggregate as in Channels , drains, Coping, benching, water troughs etc including weathering slightly rounded or chamfered angles and throuting , including necessary form work etc all as specified.
3
-
-
... More
Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc
200
-
-
... More
Cutting into existing manholes for connecting new drains(internal dia of pipe 150mm to 225mm making good to open and rendering, cutting out existing benching for and forming branch channel 1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1,smooth finished and reforming benching.
10
-
-
... More
Demolition of re-inforced Concrete of any description and in any position not otherwise specifically provided for.
10
-
-
... More
M&L RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in precast RCC manhole / septic tanks ,drain,covers including all form work and setting in CM 1:4 all as specified and shown on drgs.
10
-
-
... More
M&L mild steel TMT bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips
1000
-
-
... More
Supply and fixing steel fibre RCC manholes covers & frames medium duty circular (as per IS-12592) medium duty for clear opening 450/500mm complete all as specified and as directed by the Engineer-in-Charge.
30
-
-