Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 58,680Document Cost
₹ 500Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_671606_1Tender No
GE FRD-55/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
BOQ Items
M&L for cleaning,removing and bailing out stagnated sewage or sludge and any light particle from walls/floor from two Nos MBBR reactor inner surface with the help of wire brushes ,steel patti and emery paper and taking out damaged and unbroken MBBR media without any damage and refilling unbroken media in the MBBR, cleaning of inner and outer surface of MS pipe placed in MBBR and removing sludge particles & depositing at a distance 100 mtr away from outer wall of STP complete all as specified and directed.
4
-
-
M&L for cleaning and removing of sludge from walls/floor of tube settler tank after taking out the tube settler media with the help of wire brushe/steel patti/emery paper and depositing where directed at a distance 100 mtr away from outer wall of STP including taking out old rusted wire mesh of size 25 x 25 mm from tube settler media and cleaning the tube settler after all cleaning, supply & fixing wire mesh of same size with the tube settler and fixed in original position in the tube settler tank including painting to steel surfaces by using black bitumen paint and white wash to walls complete all as specified and directed.
4
-
-
M&L for taking out solid dry sewage waste from sludge beds of size approx 4 m X 4 m and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant complete all as specified and directed.
10
-
-
M&L for taking out solid dry sewage waste from sludge drying beds of size approx 8 m X 8 m and removing to a distance not exc 50 mtr from outer edge of Sewage treatment plant complete all as specified and directed.
14
-
-
Site clearance and surface dressing not exc 15cm by cutting and removing of elephant/wild grass (sarkanda) from all around the periphery of STPs & IPS and removing from site to a distance not exc 50 m complete all as specified and directed
750
-
-
M&L for sludge removal and acid cleaning of Clear Water Tank (Filter feed tank) complete all as specified and directed .
3
-
-
S&F MS nuts, bolts, washers and MS blind plate 3mm thick complete all as specified and directed.
15
-
-
S&F in replacement of sluice valve of size 150mm,class PN-1.6 ( ISI marked) with brass spindle, flanged end including jointing with Neoprene rubber gasket, nuts, bolts and washers etc as per existing complete all as specified & directed .
1
-
-
S&F in replacement of sluice valve of size 100mm,class PN-1.6 ( ISI marked) with brass spindle, flanged end including jointing with Neoprene rubber gasket, nuts, bolts and washers etc as per existing complete all as specified & directed .
1
-
-
S&F Cast iron fitting for flanged pipe i.e bends, tappers, Tee pieces/single & double branch any type and angle / radius and straight connecting pieces all end flanged upto 150mm bore complete all as specified and directed.
250
-
-
Supply, laying, jointing, commissioning and testing ductile iron pipes of 100mm bore with spigot and socket ends ,centrifugally cast (spun), class K-7, conforming to IS-8329-2000, in any length with & including rubber push (tyton) joint, laid in trenches complete all as specified and directed .
18
-
-
Supply, laying, jointing, commissioning and testing ductile iron pipes of 150mm bore with spigot and socket ends ,centrifugally cast (spun), class K-7, conforming to IS-8329-2000, in any length with & including rubber push (tyton) joint, laid in trenches complete all as specified and directed .
18
-
-
S&F in replacement MS pipe of size 40mm dia, heavy duty grade, with all fittings, laid in floors or fixed to wall and ceiling etc complete all as specified and directed.
24
-
-
S&F in replacement MS pipe of size 65mm dia, heavy duty grade, with all fittings, laid in floors or fixed to wall and ceiling etc complete all as specified and directed.
24
-
-
S&F in replacement MS pipe of size 80mm dia, heavy duty grade, with all fittings, laid in floors or fixed to wall and ceiling etc complete all as specified and directed.
30
-
-
S&F in replacement MS pipe of size 100mm dia, heavy duty grade, with all fittings, laid in floors or fixed to wall and ceiling etc complete all as specified and directed.
36
-
-
S&F in replacement MS pipe of size 150mm dia, heavy duty grade, with all fittings, laid in floors or fixed to wall and ceiling etc complete all as specified and directed.
12
-
-
S&F in replacement rigid PVC pipe of size 150mm dia bore, working pressure rating 10 Kgf/cm²fixed in wall, ceiling or in floor complete all as specified and as directed.
12
-
-
S&F in replacement rigid PVC pipe of size 100mm dia bore, working pressure rating 10 Kgf/cm²fixed in wall, ceiling or in floor complete all as specified and as directed.
12
-
-
Excavation in trenches n.exc 1.5 m wide & exc.1.5 m but not exc. 3 m in depth for foundation/pipe lines etc and getting out in soft/loose soil complete all as specified and directed .
48.6
-
-
Returning, filling in including spreading, leveling, watering & and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed .
42.96
-
-
Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed .
5.64
-
-
S&F in replacement C.I. butterfly valve of size 100 mm dia complete all as specified and directed.
4
-
-
Supply and fix in replacement of cast iron butterfly valve of size 80 mm dia complete all as specified and directed.
4
-
-
Supply and fix in replacement of cast iron butterfly valve of size 65 mm dia complete all as specified and directed.
4
-
-
S&F in replacement pressure gauge of size 4 '', O-10 Kg/cm², dial type complete all as specified and directed.
3
-
-
S&F in replacement Cast Iron Non return valve conforming to ISI-5312 suitable for 150 mm bore pipe, heavy duty ,both end flanged with by pass charged of pressure rating PN 1.6 and jointing with rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers complete all as specified.
2
-
-
S&F in replacement Cast Iron Non return valve conforming to ISI-5312 suitable for 100 mm bore pipe, heavy duty ,both end flanged with by pass charged of pressure rating PN 1.6 and jointing with rubber or fibre board gasket complete with and including required nos size of nuts, bolts and washers complete all as specified.
1
-
-
M&L for prepration of old metallic , treated irregular and curved surfaces of pipes including fittings , valves, steel railing , ladders DMF & ACF filters including removing existing treatment by scrapping, burning and painting with two coats of synthetic enamel paint complete all as specified and directed
200
-
-
M&L for cleaning of blocked sludge pipe of any size by excavation, opening /Cutting of pipe, cleaning by any mechanical means, taking out blocked sludge and charge it at a distance of approx 50 m from STP, rejoining the pipe with necessary accessories including reshaping the interlocking tiles (if disturbed), refilling the soil and leveling complete all as specified and directed .
8
-
-
Supply only Sodium hypochloride solution IS-11673 Grade-II for disinfection of treated water complete all as specified and directed.
Notes : (i) RV shall be prepared for supply & consumption duly verified by audit authority. (ii) Hypochloride solution shall be conforming to IS-11673-1992 and shall be supplied in packed containers. The contractor shall produce test certificates of the hypochloride solution issued by factory/ District Govt Food Inspection lab to ascertain the presence of the chlorine percentage in the consignment. In addition, independent testing for the material shall be got done by the Engineer-in-Charge to verify and check the quality .
8500
-
-
M&L for detection of leakage in water main on walls, floors or in trenches by necessary excavation in any type of soil including bailing out leakage water by suitable measures, repair to DI/CI/MS pipes of sizes from 80 mm to 150 mm bore by cutting, welding, addition & alternation and insertion of fittings/accessories required complete all as specified and directed. Note:- (i) Quoted rate shall deemed to be inclusive of necessary excavation/ filling, making good the existing surfaces & T&P as required to complete the job .
11
-
-
M&L for detection of leakage in water main on walls, floors or in trenches by necessary excavation in any type of soil including bailing out leakage water by suitable measures, repair to DI/CI/MS pipes of sizes from 40 mm to 65 mm bore by cutting, welding, addition & alternation and insertion of fittings/accessories required complete all as specified and directed. Note:- (i) Quoted rate shall deemed to be inclusive of necessary excavation/ filling, making good the existing surfaces & T&P as required to complete the job .
10
-
-
M&L for Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6.00mm thick, buried directly in ground vertically (depth of pit not less than 2.25m below normal ground level), with top edge of the plate not less than 1.5m below normal ground level, earth plate surrounded by 15cm thick and packed alternate layers of charcoal dust and common salt, connected with and including GI strip 32x6mm by means of bolts, nuts, check nuts and washers of galvanized iron or thimbles and other end of the earth wire connected to electrical equipment/GOD/LA and protected by galvanized iron pipe light grade 40mm dia bore including watering pipe 20mm dia bore GI medium grade (ISI marked) with funnel and wire mesh, including all necessary excavation and earth work, PCC chamber in plain cement concrete (1:3:6) type C-1 and pit cover of precast RCC with MS frame etc and all as shown in electrical plate No 3 of MES Schedule Part-I (2009), complete all as specified and directed. Note(s):- (i) RCC pit cover shall be pre-cast of RCC (1:2:4) type B-1, 80mm thick reinforced with TMT bar 8mm dia both ways @100c/c. (ii) PCC chamber shall be constructed 500 mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 3Ohm. In case the test results are not found below 3Ohm, complete earthing will be redone without any extra cost to Govt. (v) Quoted lump sum / rate shall be inclusive of above all provisions
5
-
-
S&F HDPE pipes of dia 110mm ,conforming to IS- 4984/95, PE-100 and maximum permissible working pressure 1.00 Mpa or 10 Kgf/cm2 complete all as specified and directed.
25
-
-
S&F HDPE pipes of dia 90mm ,conforming to IS- 4984/95, PE-100 and maximum permissible working pressure 1.00 Mpa or 10 Kgf/cm2 complete all as specified and directed.
25
-
-
S&F HDPE pipes of dia 50 mm , conforming to IS- 4984/95, PE-100, pressure rating 6 Kgf/cm2 , fixed to wall, ceiling or laid in floors etc complete all as specified and directed .
30
-
-
S&F HDPE pipes of dia 25 mm , conforming to IS- 4984/95, PE-100, pressure rating 6 Kgf/cm2 , fixed to wall, ceiling or laid in floors etc complete all as specified and directed .
25
-
-
S&F HDPE pipes of dia 20 mm , conforming to IS- 4984/95, PE-100, pressure rating 6 Kgf/cm2 , fixed to wall, ceiling or laid in floors etc complete all as specified and directed .
25
-
-
M&L for detection of leakage in HDPE pipe on walls, floors or in trenches by necessary excavation in any type of soil including bailing out leakage water by suitable measures, repair to HDPE pipes for the sizes from 90 mm to 110 mm bore by cutting, heating with proper instrument, addition & alternation and insertion of fittings/accessories all as required complete all as specified and directed.
Note:- (i) Quoted rate shall deemed to be inclusive of necessary excavation/ filling, making good the existing surfaces & T&P as required to complete the job .
10
-
-
M&L for detection of leakage in HDPE pipe on walls, floors or in trenches by necessary excavation in any type of soil including bailing out leakage water by suitable measures, repair to HDPE pipes for the sizes from 20 mm to 50 mm bore by cutting, heating with proper instrument, addition & alternation and insertion of fittings/accessories all as required complete all as specified and directed.
Note:- (i) Quoted rate shall deemed to be inclusive of necessary excavation/ filling, making good the existing surfaces & T&P as required to complete the job .
5
-
-
Material and labour in replacement for Tube Settler modules made of PVC and as per existing specification complete all as specified and directed.
18
-
-
M&L for repairing and servicing of leakages/blockage at flanges at various joints such as near pressure guage, motor, pipes within swimming pool plant premises by opening the joint and replacing flanges of size upto 25mm dia and length complete with teflon tape and other accessories to ensure no leakage all as specified and directed. Note: (i) Complete clearing of leakage at any leakage point shall be considered as one job. (ii) The rates of spares required i.e flanges/teflon tape/packings/gaskets etc shall be deemed to be included in the quoted rate of item
10
-
-
M&L for repairing and servicing of leakages/blockage at flanges at various joints such as near pressure guage, motor, pipes within swimming pool plant premises by opening the joint and replacing flanges of size 80mm dia and length complete with teflon tape and other accessories to ensure no leakage all as specified and directed. Note: (i) Complete clearing of leakage at any leakage point shall be considered as one job. (ii) The rates of spares required i.e flanges/teflon tape/packings/gaskets etc shall be deemed to be included in the quoted rate of item
8
-
-
S&F in repair PVC flexible suction hose pipe, medium duty, 50 mm dia, (ISI marked) complete all as specified and directed.
50
-
-
Supply & fix in repair Cast iron sluice valve, 80 mm dia, 1.6 PN, long body, confirming to IS- 14846 : 2000 complete all as specified and directed.
1
-
-
Supply & fix in repair Cast iron sluice valve, 100 mm dia, 1.6 PN, long body, confirming to IS- 14846 : 2000 complete all as specified and directed.
2
-
-
M&L for preparation/cleaning of old painted steel surfaces of any description such as suction line, delivery line, priming line, valves and Quartz sand filter complete by scraping out old painted surface and painting with two coats of synthetic enamel paint including marking flow direction complete all as specified and directed .
14
-
-
Supply and mixing TCCA-90 (TRICHLOROISOCYNAURIC ACID DRY TYPE) for chlorination of swimming Pool, (ISI marked) complete all as specified and directed.
700
-
-
S&F in repair star delta centrifugal pump starter, 10 HP, 415V, 3 Phase auto switch complete all as specified and directed.
1
-
-
S&F in repair Cast iron foot valve (ISI marked) of size 80 mm dia for under ground sump CI/GI suction line including nipple of suitable size, welding, connection and testing complete all as specified and as directed.
2
-
-
M&L for servicing of Splash maxim motor pump of capacity 5.0 HP/ 3 Phase, Flow : 75 Cum/Hr @ 10 M head, Pump body and support in heat resistance plastic, SS motor shaft, impeller, 2850 RPM, including replacement of filter (as per existing), filter cover,gland , greasing of bearing of pump and motor, tightening the nut & bolt and making proper aligment of motor and pump complete all as specified and directed.
4
-
-
M&L for preparation of old painted steel surfaces of pump & motor set of any capacity and painting with one coat of synthetic enamel paint complete all as specified and directed .
6
-
-
S&F in repair of electric dosing pump for chlorination, Capacity : 5.76Lph, Pressure : 10Kg/cm2, Electronic Moc of head:PP, Mounting : Topmounted, Power supply : 240V AC, Single phase including replacement of tube (as per existing) complete all as per specified and directed.
3
-
-
M&L for servicing of suction sweeper including replacement of 600mm wide suction head with four numbers rubber tired wheel spring loaded brush with towing nylon rope (as per existing) complete all as per specified and directed
1
-
-
Supply only alum in crystal pieces form for filtration of water of swimming Pool , confirming to the relevent IS (ISI marked) complete all as specified and directed.
900
-
-
Supply only copper sulphate for pool water,confirming to the relevent IS (ISI marked) complete all as specified and directed.
100
-
-
Supply only hydro chloric acid, LR type suitable for swimming pool water complete all as specified and directed.
100
-
-
S&F in repair UPVC pipe of dia 110 mm bore ,SCH 40 complete all as specified and directed.
12
-
-
S&F in repair UPVC pipe of dia 50 mm bore ,SCH 40 complete all as specified and directed.
6
-
-
S&F in repair butterfly valve 110 mm bore, made out of UPVC material of SCH40 standard quality complete all as specified and directed.
4
-
-
S&F in repair butterfly valve 50mm bore, made out of UPVC material of SCH40 standard quality complete all as specified and directed.
2
-
-
S&F in repair UPVC flange of dia 110mm complete all as specified and directed.
4
-
-
S&F in repair UPVC flange of dia 50 mm complete all as specified and directed.
2
-
-
Supply only Orthodoline solution 500ml (in bottle) with chlorine testing colour chart complete all as specified and directed.
1
-
-
Cleaning of RCC Under ground sump of capacity 50000 Ltr by scrapping the bottom surface & side walls by brooming with hard wire brush, removal of sludge/mud/silt and other foreign materials with the help of buckets etc , dewatering the entire sump and finally washing with concentrated bleaching powder solution (10 :1) of water and bleaching powder respectively and disposal of collected sludge/mud material to a distance exc. 50 m but not exceeding 100 m from the site including applying a coat of cement base primer . Date of cleaning shall be written with white paint on the black strip approx size 30" x24" complete all as specified and directed.
1
-
-
Supply only aluminium swimming pool vacuum cleaner 17.5 inch,heavy duty,vacuum head roller on wheels with handle brush, all type of pool cleaning sunction sewwper complete all as specified and directed.
1
-
-
Excavation in trenches, not exc. 1.5 metre wide and depth exc. 1.5 metre but n.exc 3.0 metre, for foundation/pipe lines etc and getting out in soft/loose soil complete all as specified and directed .
20
-
-
Returning, filling in including spreading, leveling, watering & and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and directed
19.4
-
-
Removing excavated material to a distance n.exc 50 m & depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and directed .
0.6
-
-
M&L for construction of Valve pit of size 1050mmX1050mmX1050mm (internal dimensions) (Type-B) with brick masonry construction including necessary excavation and earth work in soft/loose soil, brick work in cement mortar 1:4, 15mm thick plastering in cement mortar 1:4, three coats of white wash, PCC coping in 1:2:4 Type B-1, MS frame made out of angle iron of size 40mmx40mmx6 mm, MS sheet cover of 1.6 mm thick fixed to angle iron frame by means of hinges, welded to frame and painting with 2 coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces and grouting the frame in PCC 1:2:4 type B-1 including handle and locking arrangement with one number 50 mm dia brass pad lock , complete all as specified and directed.
.
2
-
-
S&F in replacement LED bollard 10 Watt, IP 65 rated with all fittings laid in ground with PCC 1:2:4 type B-1 block of size 60cmx60cmx60cm including making connection with wire of requisite size, 01meter long complete all as specified and directed.
12
-
-
Supply only twisted Nylon rope ( ISI marked) 15 mm dia & 30 m long, industrial grade, multipurpose, line rot alkali chemical weather resistant complete all as specified and directed.
2
-
-
S&F GI tubing, 20 mm bore, ISI marked, medium grade with all fittings , fixed to wall/ceiling and laid in trenches/under road complete all as specified and directed
100
-
-
S&F GI tubing, 25 mm bore, ISI marked, medium grade with all fittings , fixed to wall/ceiling and laid in trenches/under road complete all as specified and directed
300
-
-
S&F GI tubing, 50 mm bore, ISI marked, medium grade with all fittings , fixed to wall/ceiling and laid in trenches/under road complete all as specified and directed
200
-
-
Supply only net with frame and handle structure complete for picking up floating leaves and small insects all as specified and directed by Engr-In-Charge.
2
-
-
M&L for cleaning of water whenever as required at site by means of chlorine, PH booster, alum to maintain the PH of water at desired level and whatever is required to maintain/clean transparent the pool water upto the approval of user and MES requirement of quality of water all as specified and directed.
2
-
-
M &L for rewinding of Monoblock/Centrifugal pump (Motor) 10 Hp 3 phase 415 volt with supper emamelled copper rewinding wire of suitable size/gauge and providing insulation including taking out the existing winding, varnishing, heating, testing complete all as specified and directed.
1
-
-
M &L for rewinding of Monoblock/Centrifugal pump (Motor) 5 Hp 3 phase 415 volt with supper emamelled copper rewinding wire of suitable size/gauge and providing insulation including taking out the existing winding, varnishing, heating, testing complete all as specified and directed.
2
-
-
S&F in repair motor cooling fan for existing centrifugal pump set of capacity 12.5/7.5 HP, electric driven, 3 phase, 415 volt complete all as specified and directed
2
-
-
S&F in repair pump motor MS coupling for existing centrifugal pump set of capacity 12.5/7.5 HP, electric driven, 3 phase, 415 volt complete all as specified and directed
2
-
-
S&F in repair pump bearing for existing centrifugal pump set of capacity 12.5/7.5 HP, electric driven, 3 phase, 415 volt complete all as specified and directed
4
-
-
S&F in repair motor bearing for existing centrifugal pump set of capacity 12.5/7.5 HP, electric driven, 3 phase, 415 volt complete all as specified and directed
4
-
-
S&F in repair CI impeller suitable for existing centrifugal pump set of capacity 12.5/7.5 HP, electric driven, 3 phase, 415 volt complete all as specified and directed
2
-
-
S&F in repair Gland seal suitable for existing centrifugal pump set of capacity 12.5/7.5 HP, electric driven, 3 phase, 415 volt complete all as specified and directed
4
-
-
S&F in repair SS sleeve (Gland Sleeve) suitable for existing centrifugal pump set of capacity 12.5/7.5 HP, electric driven, 3 phase, 415 volt complete all as specified and directed
2
-
-
S&F in repair Pump motor shaft with stud and nuts suitable for existing centrifugal pump set of capacity 12.5/7.5 HP, electric driven, 3 phase, 415 volt complete all as specified and directed
2
-
-
M&L for opening of sluice valve of any size with repalcement of new spindle, disc with check nut and flange gaskit complete all as specified and directed.
5
-
-
M&L for cleaning of swimming pool of size 25 x 13.5 mtr of depth from 1m to 7m of capacity 2 lakh gallon after complete de-watering by pumps or any other means and cleaning scrapping the tiles with steel brushes/hessin cloths of the sump walls from inside including floor with cleaning of drains of the sump and refill the water through filtration plant and treat the swimming pool water at desired level by using plant and chemicals by hiring the authorised expert team complete all as directed by Engineer-in-Charge. Note: If work is not done upto satisfaction level of concerned JE/AGE (E/M) , the work will be redone upto the required level without any extra cost. Necessary pump,tools,pipe and safety measures to be arranged by contractor.
1
-
-
S&F in replacement DOL starter, push button type, suitable for 7.5HP, 3 phase 415 V,AC electric motor complete all as specified and directed.
2
-
-
S&F in replacement PVC insulated flat copper conductor cable ,4 Sqmm, 3 core ,1100 volts grade including PVC conduit including connection and testing of motor at site etc complete all as specified and directed.
Note :- A Sum of Rs. 25185.00 will be deducted on account of credit for dismantling/ demolished/ taking down material. Please refer detail on srl page No. 24 (Schedule of credit) of Tender Documents.
30
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements