Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 1,300Document Cost
₹ 1,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_639649_4Tender No
CWEAFJ-32/2023-24Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Schedule 'A' Part-II Internal Water Supply Work) carried forward from pre-priced Schedule.
1
-
-
Schedule 'A' Part-III Internal Electrification Work) carried forward from pre-priced Schedule.
1
-
-
Schedule 'A' Part-IV Protective Work) carried forward from pre-priced Schedule.
1
-
-
Schedule 'A' Part-V (Covered Path Work) carried forward from pre-priced Schedule.
1
-
-
Schedule 'A' Part-VI (Sewage Disposal Work) carried forward from pre-priced Schedule.
1
-
-
Schedule 'A' Part-VII (Ligtening Protection works) carried forward from pre-priced Schedule.
1
-
-
Schedule 'A' Part-VIII (External Electrification Work) carried forward from pre-priced Schedule.
1
-
-
Schedule 'A' Part-VIII(A) (Plumbing Work) carried forward from pre-priced Schedule.
1
-
-
Schedule 'A' Part-IX (Miscellaneous Items for B/R & E/M Rate Schedule) This Schedule is not Pre-Priced by MES and the Pre-Priced rate indicated as "Rs. 0.00" under Col. 5 signifies this fact only.
-
-
-
S & L for 5 user LLDPE septic tank designed to carry sewage and sullage water ,excavation in any type of soil,PCC 1:4:8 below foundation,vent saft,connection etc complete all as specified and directed
1
-
-
Supply and Fabrication, installation and testing of Feeder Pillar KIOSK type floor mounted dust/vermin proof outdoor type , CPRI approved,IP54 protection of size 1.2x1.5x0.6 mtr mtr factory fabricated made out of MS sheet of thickness 3.15 mm mounted on angle iron legs made out of angle iron of size 40x40x6 mm with front & rear opening with locking arrangement, containing bus bar chamber to accommodate 3 phase & 1 neutral copper busbar of size 40x10 mm fixed on epoxy based insulators in horizontal position in upper part of panel separate chambers for 01 No. incomming MCCB and 03 Nos. outgoing MCCB connected to busbar by copper strip of size 20x5 mm duly drilled hole for cable connectioin and powder coated all as required at site or as directed by Engr-in-charge (including the PCC foudation of panel) complete including of following: -
(a) MCCB 320 Amp FP 35KA (thermal, adjustable type, O/L & S/C Protection) - 01 No (I/C). (b) MCCB 100 Amp 3P 25 KA -01 Nos (c) MCCB 63 Amp 3P 25 KA -01 Nos (d) MCCB 40 Amp 3P 25 KA -05 Nos (c) Digital Multi-function meter with CT's of required cap – 01 No. (d) LED type Indicator lamps (R, Y. B) – 01 Set. (e) On load Change over switch unit four pole 200 Amps - 01 No. All accessories pre wired with suitable size copper conductor cable including making necessary arrangements for fixing all as required at site or directed.
NOTE : (1) All connections to be done with proper size copper / Brass Thimbels. (2) Control circuit wiring to be done with S/C copper wire complete all as specified and directed.
1
-
-
Supply and Fabrication, installation and testing of Feeder Pillar KIOSK type floor mounted dust/vermin proof outdoor type , CPRI approved,IP54 protection of size 1.2x1.5x0.6 mtr mtr factory fabricated made out of MS sheet of thickness 3.15 mm mounted on angle iron legs made out of angle iron of size 40x40x6 mm with front & rear opening with locking arrangement, containing bus bar chamber to accommodate 3 phase & 1 neutral copper busbar of size 40x10 mm fixed on epoxy based insulators in horizontal position in upper part of panel separate chambers for 01 No. incomming MCCB and 03 Nos. outgoing MCCB connected to busbar by copper strip of size 20x5 mm duly drilled hole for cable connectioin and powder coated all as required at site or as directed by Engr-in-charge (including the PCC foudation of panel) complete including of following: -
(a) MCCB 100 Amps FP 25KA (thermal, adjustable type, O/L & S/C Protection) - 01 No (I/C). (b) MCCB 63 Amps 3P 25 KA -04 Nos (c) Digital Multi-function meter with CT's of required cap – 01 No. (d) LED type Indicator lamps (R, Y. B) – 01 Set. All accessories pre wired with suitable size copper conductor cable including making necessary arrangements for fixing all as required at site or directed. NOTE : 1) All connections to be done with proper size copper / Brass Thimbels. ( 2) Control circuit wiring to be done with S/C copper wire complete all as specified and directed.
2
-
-
Fabrication, installation and testing of LT feeder pillar box floor mounted dust/vermin proof outdoor type, powder coated of size 0.60x0.85x0.50 mtr factory fabricated, made out of MS sheet of thickness 3mm mounted on angle iron legs made out of angle iron of size 40x40x6mm withn front & rear opening with locking arrangement, containing bus bar chamber to accommodate 3 phase & 1 neutral copper busbar of size 20 x 10mm drilled with suitable holes for fixing of cables and mounted on epoxy based insulators in horizontal position (stepped manner) in feeder pillar including necessary excavation and PCC work 1:2:4 complete all as specified and directed by Engr-in-charge.
2
-
-
S&F MCCB 4 Pole 415 Volts in sheet steel enclosure adjustable type with rupturing capacity 35/36 KA 250 Amps adjustable type thermal Magnetic release with overload and short circuit protection complete. Note : The quoted rates by the bidder for MCCB should be inclusive of sheet steel enclosure.
1
-
-
Supply , installation , testing and commissioning of Diesel engine driven generating set silent complete with acoustic enclosure in accordance to ASCE7-10 and control system complete with panel for automatic starting on mains failure, Output of 128 KW/160 KVA and working temperature range (-) 20 degree centigrade to (+) 70 degree centigrade & alternator of suitable capacity and RPM, coupled with each other and capable of taking 10% overload for one hour on every 12 hours with flexible coupling mounted on common base plate and antivibration pads on foundation as recommended by the manufacturer. The DG set shall comprise of electric starter motor with batteries of 24 Volts, 160 AH including suitable lead for charging with copper /brass terminals. The DG set shall have turbo charger after cooled type and electronic governing. AVR with all standard fittings, fixtures & all piping etc as furnished below and specified.(a) Voltmeter : Voltmeter with 0-500 Volts, flush mounted 96mm square digital type with selector switch suitable to connect voltmeter to stand by or mains supply. (b) Ammeter : Ammeter with 0-300 Amps CT's operated flush mounted 96 mm square digital with selector switch and CT's of appropriate ratio.
(c) Digital Frequency meter : Digital frequency meter with 440 Volts , 5 Amps with built in transducer flush mounted 96 mm square size
1
-
-
(d) Indicator lamp - Indicator lamp LED type 230 volts Gen Set/Mains supply ON/OFF indication and recommendation by manufacturer.
(e) Bakelite fuse- Backlite fuse base carrier with HRC fuses 300 Amps, 415 Volts suitable for and including knife type HBC fuse link of make : Standard conforming to Cat part No: BSC- 030630 and HSCD- 02200-135 or equivalent of make : Havells- 08 Nos.
(f) Accessories and prewiring - All accessories should be prewired with PVC insulated copper conductor cable of appropriate size including connection from DG set all as requried at site including foundation as per manufacturer's instructions.
(g) Foundation - PCC foundation for as per manufacturer's instructions, recommendation or as required at site or as directed by Engr-in- charge . Cost of the same shall deemed to be included in the lump sum cost of DG set quoted by the contractor.
Note : The engine shall be affixed with label mentioning the following :-
(i) Name and address of the engine manufacturer.
(ii)Type approval certificate Number. (iii) Date of manufacture of engine.
(iv) The complete generating set inclusive of control panel base frame coupling etc shall be from the OEM & shall be assembled & tested at engine manufacturer's workshop and test certificate shall be provided by the contractor.
-
-
-
(v) Environment-
(i) Engine conforming to environment (protection) Rule 1986. (ii) Humidity up to 95% , (non condensing) (iii) Operating temp range (-) 20 degree centigrade to (+) 70 degree centigrade .
(iv) Height above mean sea level (MSL) - 2744 Mtr.
(a) Time permitted to build up rated voltage 5 sec.
(b) short circuit with stand time 10 sec.
(c) Short circuit ratio 0.4
(d) Overload withstand capacity minimum 150% for 15 sec.
(e) Type of cooling system alternator - Air cooled system.
(f) Temp rise of armature winding - 125 Degree Centigrade
(g) Temp rise of field winding - 125 Degree Centigrade. (h) Flow of alternator -6 m3/min (approx)
(h) Flow of alternator -6 m3/min (approx)
(k) Efficiency of alternator- (i) at 100% MCR & rated PF -94.0% (ii) at 75% MCR & rated PF -94.1% (iii) at 50% MCR & rated PF - 93.6%
Diesel Engine : Diesel Engine water cooled and electric start suitable to drive above alternator independently , coupled directly through flexible coupling , multi cylinder four stroke, cold starting 1500 RPM industrial type as per
-
-
-
BS-649 or IS-1601 with Mechanical governor integral with fuel system , to regulate speed of DG set from no load to full load complete with fule tank of capacity as per manfacturer's recommendation , including lowest weight to power ratio of 2.18 for Engine Silencer, Exhaust manifold duly insulated with asbestos rope and all fitting accessories such as bends, flanges, reducers and support structure from ceiling and silencer muffler etc for continous operation and standard accessories, extended to a suitable distance outside the DG Set Room as directed by Engr-in-charge , sump preheater etc all as specified and directed as follows:- (Note : Nine free service checks during warranty period
(a) Aspiration - Turbocharged & after cooled. (b) Starting system - 24 Volts , Electric (c) Exhaust silencer type - Residential/ Hospital grade.
(d) Exhaust noise level (with silencer)@ 1M - 75dB (A)
(e) Recovery time in goveror system - 8 Sec
(f) Max time to start from cold & attain rated speed & ready to start-5 sec.
(g) Overload capacity - 10% for 1 hour in 12 hours of operation.
2
-
-
Control Panel - The standard control panel consisting of control cubical fabricated sheet steel construction indoor type suitable for mounting accessories as compries below: Operator Interface Threshold warning Indications
(a) Manual start/stop (a) Low oil pressure
(b) Auto /remote start (b) Low Engine coolant Temperture
(c) Auto LED (c) High Engine coolant Temperture
(d) Not in Auto LED (d) Low Coolant level
(e) Manual LED (e) Low Battery Voltage
(f) Common shutdown LED (f) High Battery Voltage
(g) Common Warning LED (g) Battery Alt Charge Fault
(h) Exercise LED (h) Over Current
(J) Alphanumeric screen (J) Overload
(K) Emergency stop (Local and remote)
(I) Remote start input active (LED)
(m) Fault reset
-
-
-
Measurement & Instrumentation- (Engine Side)
(a) Oil Pressure (b) Oil temperature (c) Water Temperature (d) Engine speed (e) Hours Run
(f) Number of starts
(g) Battery Voltage (h) Exhaust Temperature
Measurement & Instrumentation- (Alternator Side) - 3 Phase L-L & L-N Voltage & Frequency (a) 3 Phase Current (b) KWH
(c) Total KVA
(d) Total KW & KVAr
(e) PF
(f) Per Phase , KVAr, KW
(g) Per Phase KVA
Shutdown protection & Indication Shutdown protection & Indication (Engine Side) (Alternator side)
(a) Low fuel level (a) Under & over voltage
(b) High fuel level (b) Under & over Frequency
(c) Low oil pressure (c) Over current (d) High engine coolant temperature (d) Earth leakage
(e) Failure to Crank Shutdown (e) Reverse Power
(f) Over crank (Failure to start) (f) Reverse Var
(g) Over Speed
-
-
-
Power Transfer Function :
(a) Open Transition Transfer
(b) Hard Closed Transition (c) Soft Closed Transition ( ramping)
(d) Transfer & Base Load (Utility) (e) Gen / Mains Breaker Control
(f) Gen/ Mains Breaker Status protection
Electric Starter Equipment :-
The Equipment will comprise the following:-
(a) Maint free battery duly initally charged and battery lead with copper / brass terminals with 160 AH capacity or as suggested by the OEM with fixing and locking arrangement complete.
(b) Starter Motor (c) Starter Gear (d) Start/stop push button (e) Invertor cum battery charger 500 VA capacity suitable to work on 230 volts, 50 Hz AC Supply system for charging the DG set batteries externally when DG set is in off Position. (f) Alternator / dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut out all as per manufacturer's recommendation.
-
-
-
AMF Panel :-
Auto mains failure panel (OEM manufactured) 415 Volts. 50 Hz suitable for 160 KVA/128 KW DG Set made out of 16 guage mild steel sheet factory made with CRCA sheet cubical type floor mounted front and rear door openable with locking arrangement duly powder coated suitable for including the following:-
(a) Microprocessor based auto transfer switch 4 pole 200 Amps, 415 Volts MCCB 02 Nos electronic control box for automatic switching on and off of DG Set and transfer of load as assembled and ready to use complete in all respect equipped as below :-
(b) On load change over switch 4 pole 415 volts 50 Hz 200/250 Amps in open execution for manual change over of supply in case of AMF panel failure.
(c) All accessories prewired with suitable size PVC insulated copper conductor cable of appropriate size including connections from DG set all as required at site including foundation as per manufacturer recommedations.
Note : The AMF panel shall be integrated & synchronised with respective LT distribution panel and all electrical connection completed using copper bus bars PVC sleeved or appropriate rating but not less than as of LT panel and testing of DG Set to be carried out as specified in PS clause and policy in vogue and results to be submitted to Accepting Officer. The Contractor shall ensure for factory visit of rep detailed by AO before despatch of DG Set.
-
-
-
Sub Total i.e. Total of Schedule 'A' Part-IX i.e. Serial Item No 10.01 to 10.13
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%