Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Electrical and Electronics
Electrical Works
Eprocure
Opening Date26 Jun 2024
Closing Date23 Jul 2024
Tender Amount₹ 43,21,000 
Notes
Download

Costs

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
All as per Srl Item No. 3.00 here-in-before but of size 95 sqmm 3.5 core.

110

-

-

... More
All as per Srl Item No. 3.00 here-in-before but of size 70 sqmm 3.5 core.

540

-

-

... More
All as per Srl Item No. 3.00 here-in-before but of size 50 sqmm 3.5 core.

420

-

-

... More
All as per Srl Item No. 3.00 here-in-before but of size 35 sqmm 3.5 core.

130

-

-

... More
All as per Srl Item No. 3.00 here-in-before but of size 25 sqmm 4 core.

160

-

-

... More
All as per Srl Item No. 3.00 here-in-before but of size 16 sqmm 4 core.

1345

-

-

... More
All as per Srl Item No. 3.00 here-in-before but of size 16 sqmm 2 core.

250

-

-

... More
All as per Srl Item No. 3.00 here-in-before but of size 10 sqmm 2 core. Note for Srl item No 2.00 to 11.00 : Quoted rate include cost of any cutting required in wall, floor tiles for laying of pipe and cables, making good to disturbed surfaces to match with existing surfaces including any type of civil work

240

-

-

... More
Excavation in trenches in soft/loose soil not exceeding 1.50 mtr wide and not exceeding 1.50 mtr in depth for laying of cables and getting out complete all as specified and directed

618.19

-

-

... More
Returning, filling in, including spreading, levelling watering and well ramming in layers not exceeding 25cms thick each layer compete all as specified and directed

349.93

-

-

... More
Removal of surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed

313.26

-

-

... More
Material and labour for sand cushioning with a layer of sand 8cm thick before laying of cable and 15 cm thick after laying of cable in trenches complete all as specified. Note : Punned thickness of 18 cm should be considered for payment

222.55

-

-

... More
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length, adjacent/ abutting each other complete all as specified and directed

19.98

-

-

... More
Laying only cable cover/ brick, laid breadth wise along the length of cable laid in trenches complete all as specified and directed.  Note : Serviceable cable cover/ bricks obtained from Srl Item No. 1.00 here-in-before

2000

-

-

... More
Supply and fixing galvanised pipe light grade of 100mm bore for passing of cable fixed to poles/walls/laid under floor complete with and including fittings as required compete all as specified and directed.

12

-

-

... More
Supply and fixing galvanised pipe light grade of 80mm bore for passing of cable fixed to poles/walls/laid under floor complete with and including fittings as required compete all as specified and directed.

42

-

-

... More
Supply and fixing galvanised pipe light grade of 50mm bore for passing of cable fixed to poles/walls/laid under floor complete with and including fittings as required compete all as specified and directed.

40

-

-

... More
Supply and fixing galvanised pipe light grade of IS marked 40 mm bore for passing of cable fixed to poles/walls/laid under floor complete with and including fittings as required compete all as specified and directed.

40

-

-

... More
Material and labour for boring hole under the road / pavement / hard standing with the help of trenchless technology using ultra sound technique and necessary machine and including HDPE pipe 100 mm of size not less than one metre below ground level complete all as specified and directed.

25

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following all as specified :- (a) Bus bar made of copper suitable for capacity 1000 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 630 Amp, 415 V, 36 KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display, accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase -01 set OUTGOING:- (a) MCCB 400 Amp, 415 V, 36 KA, 4 pole with thermal magnetic release -01 No. (b) MCCB 200 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release -01 No. (c) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -02 Nos. (d) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (e) MCB 40 Amp TPN, 415 V,10KA - 2 Nos

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following all as specified:- (a) Bus bar made of copper suitable for capacity 300 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow , blue and black) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 200 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display , accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase -01 set OUTGOING:- (a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (b) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -02 Nos (c) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No.

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following complete all as specified:- (a) Bus bar made of copper suitable for capacity 200 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow , blue and black) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display , accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB , 3 Phase -01 set OUTGOING:- (a) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -04 Nos. (b) MCB 63 Amp SPN , 220 V, 10 KA -02 Nos

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following complete all as specified:- (a) Bus bar made of copper suitable for capacity 300 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow , blue and black ) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 200 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display , accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB , 3 Phase -01 set OUTGOING:- (a) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No (b) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (c) MCB 63 Amp SPN, 220 V, 10 KA, -01 No

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following complete all as specified:- (a) Bus bar made of copper suitable for capacity 600 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 400 Amp, 415 V, 36 KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display , accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase -01 set OUTGOING:- (a) MCCB 200 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release -02 Nos. (b) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (c) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (d) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -02 No. (e) ON LOAD changeover switch - 400 Amp 4 pole 415 V - 01 No

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following complete all as specified:- (a) Bus bar made of copper suitable for capacity 300 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 200 Amp, 415 V, 25KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display , accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase -01 set OUTGOING:- (a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (b) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -02 Nos. (c) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No.

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following complete all as specified:- (a) Bus bar made of copper suitable for capacity 300 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 200 Amp, 415 V, 25KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display , accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase -01 set OUTGOING:- (a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (b) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (c) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -02 Nos. (d) MCB 63 Amp SPN , 220 V, 10 KA, -03 Nos

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following complete all as specified:- (a) Bus bar made of copper suitable for capacity 600 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 400 Amp, 415 V, 36 KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display, accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase -01 set OUTGOING:- (a) MCCB 200 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release -02 Nos. (b)MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No (c) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -03 Nos

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following complete all as specified:- (a) Bus bar made of copper suitable for capacity 300 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 200 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display, accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase -01 set OUTGOING:- (a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -02 Nos. (b) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -02 Nos

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following complete all as specified:- (a) Bus bar made of copper suitable for capacity 300 Amps coloured with plastic coated insulated and sleaves in four colours (Red, Yellow, blue and black ) fixed on porcelain insulators with necessary nuts and bolts and washers etc INCOMING : - (a) MCCB 200 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display , accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase -01 set OUTGOING:- (a) MCCB 160 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release -01 No. (b) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (c) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (d) ON LOAD changeover switch - 200 Amp 4 pole 415 V - 01 No

-

-

-

... More
Supply, install, testing and commissioning of Feeder pillar, outdoor type weather and vermin proof totally enclosed made out of 3.15 mm thick CRCA sheet machine pressed of suitable size having min depth 500mm, to operate on 3 phase 4 wire system, 415 volts, 50 Hz double door with front and rear openable with locking arrangement, three hinges min for each leaf heavy sliding bolts on front and rear side, including inner shutters for mounting switchgears etc, removable bottom gland plate of 3.15 mm thickness with sufficient numbers of circular cable entry holes. Lt panel shall have FRONT & REAR side marking on doors, DANGER sign board. All MCCBs, outgoing feeders shall be provided with extension links/ spreader links on both sides. The connection from main bus bar to MCCB incomer side should be through bus bar only. LT panel shall be prewired complete duly powder coated with 7 tank process with angle iron frame of size 40 x 40 x 5mm of min height 80cm fixed in PCC 1:2:4 completely comprising with following complete all as specified:- (a) Bus bar made of copper suitable for capacity 250 Amps with coloured heat shrinkable sleeves in four colours (Red, Yellow, blue and black) fixed on porcelain insulators with necessary nuts, bolts and washers etc INCOMING : - (a) MCCB 160 Amp, 415 V, 25 KA, 4 pole with thermal magnetic release -01 No.

1

-

-

... More
(b) Multifunction meter with LCD display , accuracy class 1.0, having parameters KW, KVA, KVAh & PF duly prewired with suitable size of copper insulated FRLS wire with universal code including suitable CTs complete - 01 No. (c) Indicator with neon lamps for RYB, 3 Phase -01 set OUTGOING:- (a) MCCB 100 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -01 No. (c) MCB 63 Amp SPN, 220 V, 10 KA, -03 Nos (b) MCCB 40 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release -02 Nos. (c) MCB 63 Amp SPN, 220 V, 10 KA, -03 Nos Notes for Srl Item No. 23.00 to 33.00 : (i) LT panel shall have apron on three sides for LT panel fixing stand. (ii) All MCCB shall have Breaking cap Ics=100% Icu. (iii) The current carrying cap of Bus bar shall be designed based on 1.5 Amp/ Sqmm.

-

-

-

... More
Taking out old serviceable LT panel/ feeder pillar with MS angle iron structure complete without any damage to LT panel and switchgear for safe custody fix at other location within Jalandhar Cantt along with any type of civil work complete all as specified and directed

4

-

-

... More
Taking out old unserviceable LT panel complete for taking credit as per Sch of credit including any type of civil work involved complete all as specified and directed. Note for Srl Item No 34.00 & 35.00 : (i) The decision of Engineer in charge/GE regarding decision of serviceability condition of panel will be final. Unserviceable panel shall be property of contractor after deduction Sch of credit only. (ii) No claim of contractor will be entertained on this account.

3

-

-

... More
Material and labour in replacement earthing complete with GI or steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground vertically in a pit not less than 2.25 meter below ground level with top edge of earth plate at a depth not less than 1.5 meter below level covered on all sides with alternative layers of charcol dust and common salt 15 cm thick connected to galvanised earth lead Galvanised Iron strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of Galvanised Iron or steel with protection pipe earth wire protected by galvanized steel pipe medium grade 40 mm bore from top of the earth plate electrode upto test point and watering pipe 20mm bore, GI light grade with funnel and wire mesh all as shown in electrical plate No 3 of SSR Part-1 and connected to earthing test point all as specified or indicated and testing on completion, including PCC earth pit (1:3:6) type C-2 RCC covered with CI cover hinged with frame including excavation and earth work complete all as specified and directed. Notes : (i) If result is not satisfactory then contractor will do 2nd earthing on his own cost. (ii) Earth pit should be properly marked for body earth, neutral earth and for particular electrical equipment earth

13

-

-

... More
Supply, installing, testing and commissioning busbar box with factory fabricated prewired bus bar, cubical type of size 750mm x 750mm x 400 mm out door dust vermin proof, made out of 50x50x6mm angle iron frame/legs and 3.15mm thick CRCA sheet with openable shutters on both sides (front & rear), powder coated externally and internally, having locking arrangement mounted on four MS Iron leg frame 80cm high made of angle iron frame 40 x 40 x 5mm, embedded in accommodate the following accessories :- (i) MCCB 63 Amp, 415 V, 16 KA, 4 pole with thermal magnetic release Ics=100% Icu with spreader links (ii) Copper bus bar 200 A for three phase and neutral (length min 550mm) duly insulated with sleeves of different colour RYB (iii) Volt meter-01 No (iv) Ampere meter-01 No with set of CTs (v) Indicator R,Y,B - 01 Set

3

-

-

... More
Taking down ACSR of any type and any size by opening binding wires, removing outgoing electric connections by opening cable connections, removing spacers complete all as specified and directed

0.5

-

-

... More
Material and labour for fixing cable tray hot dip galvanizes steel straight/ bend perforated type having thickness of 18 SWG and of size having width 50mm height 25mm or next higher size available including coupler plate and fixing on wall through suitable size of screw, nut and washer so that tray should be proper in line without sagging after laying of cable over there completed all as specified and directed

50

-

-

... More
Taking down carefully existing point wiring of any type (i.e. on wooden batten, surface conduit, casing capping or concealed conduit) complete for light, fan socket or power point with fittings and fixtures such as ceiling rose, electric fittings, holders, switches, sockets, wooden batten, conduit etc including accessories such as wooden gutties/ rawal plug, screw etc including removing materials from site and making good to disturbed surface of walls, floors etc. complete all as specified and directed

40

-

-

... More
Taking down main switch/ DB complete all as specified and directed

65

-

-

... More
Taking down unserviceable submain/ cable of any size complete all as specified and directed

959

-

-

... More
Material and labour for point wiring with 2.5 Sqmm (nominal area) FRLS copper conductor unsheathed cable for one 3 Pin 15 Amp socket on independent board, IS-694 marked, drawn through existing non metallic rigid PVC concealed conduit of any dia and in and including modular metal flush mounting box with white cover plate with frame of suitable module, screws and washers including one 2.5 Sqmm copper conductor multi stranded green colour PVC insulated unsheathed FRLS cable 1100 volts grade as earth wire connected to common earth and earth dolly with all accessories complete all as specified and directed.

40

-

-

... More
Supply and fixing piano switch 1 way 16A complete all as specified and directed

40

-

-

... More
Supply and fixing flush type socket 5 pin 16 Amp complete all as specified and directed

40

-

-

... More
Supply, installation & commissioning load distribution board VTPN 4 way double door, for mounting MCCB as incoming MCB outgoing as MCB, factory made, conforming to IS, fabricated out of CRCA sheet, fitted with DIN channel, neutral link and suitable rated bus bar, DBs shall be semi glossy finished with epoxy polyester based powder paint sprayed and backed at high temperature, between powder paint process the sheet steel having to go through the anti-rust conditioning in not less than seven tank process to ensure smooth finish and protection against corrosion atmosphere The DBs shall be double door type with hinged door with locking arrangement. The MCCB and SP/ TP MCB shall be of same make as DB. DB shall also be provided with label marking indicating the incoming and outgoing circuits on all way as specified . The DBs shall be of IP-43 IK-09 with metal door complete all as specified and directed at site.

30

-

-

... More
Supply and fixing MCCB 4 pole, 415V, adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and directed

5

-

-

... More
Supply and fixing 4 pole MCB TPN type 100 Amp, 50 Hz, 415V with rupturing capacity 36 KA complete all as specified and directed

25

-

-

... More
Material and labour for earthing complete with & including galvanised earth plate of size 600 x 600 x 6mm thick, buried vertically in ground to a depth not less than 2.25 metre below ground level, with top edge of earth plate not less than 1.5 below ground level connected to galvanised earth wire 4mm dia connected soldered and riveted to earth plate by means of nuts, bolts , check nuts & washers, of galvanised iron or steel all as Shown in electrical plate No. 3 of MES SSR Part- I (2009) and connected to panel board, all as specified and testing on completion including provn of earth wire protected by 15mm dia light grade GI pipe upto 7.5 meter from electrode to earth terminal point Feeder Pillar box including provn of the earth plate surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of not less than 15cm in alternate layers of charcoal and salt on all sides of earth plate, GI light grade watering pipe of 20mm dia with funnel with wire mesh including all necessary excavation & earth work in any type of soil, returning filling in, removal of surplus soil to a distance 50 metre, PCC 1:3:6 type C-1 as in earth chamber, 50mm thick RCC cover using cement concrete 1:2:4 type B-0 reinforced with & including 8mm dia mild steel TMT bar @ 100 mm c/c Both way with suitable handle for lifting arrangement & including form work complete all as specified & shown on drawings and testing & directed. Note : On testing, after completion of job, if desired earth resistance is not obtained, the earthing shall be redone at without any extra cost by contractor.

1

-

-

... More
Supply and fixing in repair/ replacement sheet metal enclosure for DB when MCBs to be used, SPN 8 ways 240V, with copper bus bar, double door, epoxy/ powder coated inside and outside complete all as specified and directed

35

-

-

... More
Supply and fixing Amp rating 240V, 10 KA ‘C’ miniature circuit breaker (MCB) SPN 65 Amp of following pole sand current carrying capacity in the MCB DB complete with connection testing and commissioning, SPN 40 to 63 Amp complete all as specified and directed

35

-

-

... More
Supply and fixing MCB SP 6-32 Amps 240V complete all as specified and directed

400

-

-

... More
Material and labour in repair submain wiring with four run of single core FRLS, PVC insulated unsheathed multistranded copper conductor cable of size 6 Sqmm drawn through in existing PVC rigid non metallic concealed conduit including two run of earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable of size 6 Sqmm with green insulation including taking down old submain wiring and making good disturbed surface of walls, floors etc. including taking down existing unserviceable/ burnt submain complete all as specified and directed

550

-

-

... More
Material and labour in repair submain wiring with two run of single core FRLS, PVC insulated unsheathed multistranded copper conductor cable of size 4 Sqmm drawn through in existing PVC rigid non metallic concealed conduit including two run of earth continuity FRLS PVC insulated unsheathed multistranded copper conductor cable of size 4 Sqmm with green insulation including taking down old submain wiring and making good disturbed surface of walls, floors etc. including taking down existing unserviceable/ burnt submain complete all as specified and directed

670

-

-

... More
Surface excavation n.exc 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed

300

-

-

... More
Material and labour for rolling and consolidating formation surfaces in cutting by hand roller 0.2 to 0.5 tonne complete all as specified and directed

30

-

-

... More
Material and labour for hardcore of broken stone or boulders of gauge n.exc. 63mm, deposited, spread and levelled in layers n.exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed

30

-

-

... More
Material and labour for 100mm thick cement concrete 1:3:6 type C-2 (using 20mm graded stone aggreage) as in sub base of flooring complete all as specified and directed

300

-

-

... More
Material and labour for 30mm sand cushion, filling under floors or in foundations including watering and consolidation complete all as specified and directed

9

-

-

... More
Material and labour for laying 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment, confirming to IS 15658-2006 of M-35 grade complete all as specified and directed Note : The sample shall be got approved from the GE before build procurement and lots shall be got tested independently by the GE

300

-

-

... More
Material and labour for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in sides of rounded or chamfered on edges of interlocking tiles complete all as specified and directed

6.75

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.