Military Engineer Services Tender

If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.

Military Engineer Services - MES Tender

Works
Civil And Construction
Civil Works Others
Eprocure
Opening Date25 Jan 2025
Closing Date15 Feb 2025
Tender Amount₹ 40,70,000 
Notes
Download

Costs

Summary

Special Repair Of Shed No-13 (a And B Veh Store), And Provn Of Temp Storage Accomodation

Description

Unlock the Tender details for free
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user

Contact

Unlock the Tender details for free
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
Notice Inviting Tender (NIT)
Tender Documents containing BoQ Schedule A
Tender documents containing General conditions special conditions and particular specifications
Report Missing Document

BOQ Items

... More
DO_NOT_SHOW

-

-

-

View all details for FREE
... More
M&L for Machine cut mirror polish, kota stone slab, 18mm (+ 2mm) thick as in risers of step, skirting, dado etc and including 10 mm thick rendering in cement mortar 1:4 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.

40

-

-

... More
Demolition of brick work or stone/boulder masonary built in cement mortor including all quoins,arches,pillars etc complete all as specified.

7

-

-

... More
M&L Brick work with Fly ash bricks minimum class designation 100 straight or curved on plan exceeding 6m mean raidus bulit in C:M 1:6 complete all as specified and directed.

147

-

-

... More
Taking down cement plaster of any description, any thickness from external/internal surfaces of walls/soffits/ceilings etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed.

395

-

-

... More
M&L for Removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in lime or mud mortar; not previously plastered; and scrubbing down with water etc. to receive plaster all as specified and directed

420

-

-

... More
M&L for Cement plastering 15mm thick in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturer's instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and fair without using extra cement complete all as specified and directed.

985

-

-

... More
M&L for 10mm thick cement plastering in cement mortar 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as specified and directed.

960

-

-

... More
Complete removal of existing treatment of any type/description from walls/RCC surfaces/ceiling/chajjas/roof projections etc with mechanical means/grinder or manually (if directed) complete all as specified.

100

-

-

... More
Preparation of surfaces and Applying two coats of oil bound distamper white or tinted, over and including a coat of primer including preparation of newly plastered Surfaces of wall complete all as specified and directed.

1010

-

-

... More
M&L for preparation of surfaces of external walls/RCC surfaces/soffits of chajjas/roof projections/cantilevers/balcony etc and applying two coat of cement base paint with highlighter of any approved shade @ 5 sq.m/kg/1 coat over using brush or roller complete all as specified & as directed.

1035

-

-

... More
Dismantling plain or corrugated roof sheeting/ wall claddings, any gauge, thickness/material, including nainital or similar pattern as on roof coverings all as specified.

1115

-

-

... More
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated/semi corrugated steel sheet of 0.50mm thickness, minimum Tensile Strength 550 MPa, Alu-Zn coating 70 gsm, minimum weight 4.08 Kg/sq.m, of colour as approved as in roof covering/ wall claddings/ chajjas, fixed with fasteners/self tapping screws as recommended by manufacturer complete all as specified and directed. Note : 1. Fixing of sheets will be done strictly according as per manufacurer's instructions. 2. The rates for laps shall be deemed to be included in the quoted rate shall not be measured & paid separately.

870

-

-

... More
S&F 2mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc, of colour as approved as in ridge/gutter, fixed with fasteners/self tapping screws as recommended by manufacturer complete all as specified and directed. Note : 1. Fixing of sheets will be done strictly according as per manufacurer's instructions. 2. The rates for laps shall be deemed to be included in the quoted rate shall not be measured & paid separately.

60

-

-

... More
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet of min 0.45mm thickness, Min. Tensile Strength 550 MPa, of colour as approved as in ridge/gutter, fixed with fasteners/self tapping screws as recommended by manufacturer complete all as specified. Note : 1. Fixing of sheets will be done strictly according as per manufacurer's instructions. 2. The rates for laps shall be deemed to be included in the quoted rate shall not be measured & paid separately. Make : Tata Bluescope/JSW

50

-

-

... More
Dismantling plain or corrugated roof sheeting/ wall claddings, any gauge, thickness/material, including nainital or similar pattern as on roof coverings/ wall claddings and re-fixing the same in same/ other position with self tapping screws all as specified and directed .

30

-

-

... More
S&F MS hollow rectangular/square/circular tubes/pipes of YST 310 Grade as in frame work for roofs/rafters/purlins/chajjas/trusses/ columns/ struts etc and like similar items etc. complete all as specified.

200

-

-

... More
M&L for preparation of steel and iron surfaces of any description/ section/ trusses/ purlins, not otherwise described n.exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coats of red oxide complete all as specified.

161

-

-

... More
M&L for preparing steel and iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified.

20

-

-

... More
M&L for preparing old painted primed steel and iron surfaces of any description, not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by Engr-in-Charge.

5

-

-

... More
M&L for hardcore of broken stone boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.

24.75

-

-

... More
M&L for Cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in plinth protection, 50 mm thick, surfaces finished even and fair without using extra cement as in plinth protection including provision of construction joints and filling the same with polyureathene complete all as specified and directed.

90

-

-

... More
Taking down chowkhats or frames (without taking off shutters from the frame) n. exc 1.5 Sqm incl cutting holes and making good to disturbed surfaces complete incl ventilators including reqd shape for hold fast block for new frame complete all as specified and directed.

3

-

-

... More
Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm incl cutting holes and making good reqd shape for hold fast block for new frame complete all as specified and directed.

3

-

-

... More
S&F steel windows 1.25 mm thick Box type (primer coated) ERW hollow ‘P’ section of size 60mmx25mm single rebated comprises of glazed and skeleton shutter EWR Sec 50mmx20mm and 1mm thick and two openable leaf consisting two Nos sash bar of ‘T’ section 20mm x 3mm complete welded to frame with one vertical mullion of EWR box ‘T’ section of size 60mmx25mm and 1.25mm thick including cuttings holes and making good dismantled portion in PCC (1:2:4) type B1 for four nos for each window including S&F following fittings welded to each window :- (a) Holdfasts 150mm long 12mm x 3mm made to shape – 04 Nos per window (b) Handle of Z Sec 20mmx25mm, 100mm long – 1 Nos of leaf, (c) MS tower bolt 150mm long - 02 Nos per leaf (d) ‘Z’ sec 20mm x 25mm, 100 long stopper – 01 Nos per leaf, (e) Cleat 55 mm long of hollow square 15mmx20mmx63mm welded to hinges – 01 Nos per leaf (f) MS pintal hinges of size 75mmx12mm – 02 Nos per leaf (g) Fabrication and fixing arrangement complete. (h) Clear Glass 4 mm thick (j) Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm (k) Grill of 8mm sq. bar of length equal to the width of window @ 100mm c/c with cut space to accomodate the handle where directed/applicable.

4

-

-

... More
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 125 x 60-65 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 720 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge.

18

-

-

... More
S&F of flush doors of HDHMR board 32mm thick with both side laminate (BSL), minimum density 850 kg/cu.m, borer resistance, highly water resistance, zero bubble finish complete all as specified.

10

-

-

... More
S&F stainless steel finished 202 Grade butt hinges 150mm long complete all as specified and directed.

24

-

-

... More
S&F Stainless Steel 202 Grade Finished curved Handles 150 mm long complete all as specified and directed.

6

-

-

... More
S&F Stainless Steel 202 Grade Finished Sliding Door Bolt/Aldrop 16 x 300mm with square nuckle complete all as specified and directed.

3

-

-

... More
M&L for Reinforced Cement Concrete (RCC) 1:1/5:3 using 20mm graded stone aggregates as in beams/ lintel bands/ roof bands/beams and the like structures complete all as specified and directed.

5

-

-

... More
M&L for Form work rough finished to sides and soffits of beams/ lintel bands/ roof bands/beams and the like structures complete all as specified and directed.

40

-

-

... More
M&L for TMT Bars 10mm dia & over cut to length, bent to shape required including cranking, bending spirally hoping for columns, hooking ends and binding with mild steel wire not less than 0.9 mm dia complete all as specified and directed.

1150

-

-

... More
M&L for TMT Bars 5mm to 10mm dia as in stirrups, spacers and binders cut to length, bent to shape required including cranking, bending spirally hoping for columns, hooking ends and binding with mild steel wire not less than 0.9 mm dia complete all as specified and directed.

298

-

-

... More
S&F PVC(HDPE) SWR , 200 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction, laid in trenches or floors complete all as specified.

16

-

-

... More
M&L for pre-polished Baroda Green marble, machine cut as in floorings/ shelves/ steps/ cills/ jambs/ skirting/ border only in tile flooring and the like works and flooring etc, 15-16 mm thick including bull-nose the exposed sides/lengths, set and jointed in cement slurry over & including screed of 15 mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab for fixing on concrete surfaces or with suitable adhesive for fixing on un-polished kota stone slabs including rubbing, cutting and mirror type granite polishing complete all as specified. Note : Single piece should be used in steps/cills/jambs/shelves.

3

-

-

... More
M&L for PCC 1:2:4 type B-0 (12.5mm graded stone agg.) as in roof kerbs or mud stops/ copings/ bencing etc including weathering, slightly rounded or chamfered complete all as specified and directed.

2

-

-

... More
Excavation in earth work for soft/loose soil in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, complete all as specified and directed.

45

-

-

... More
M&L for Cement concrete 1:3:6 type C2( 40mm graded aggregate ) in sub base of foundations, filling and mass concrete complete all as specified and directed.

5

-

-

... More
S&F Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.

31

-

-

... More
M&L for cement concrete nominal mix 1:1.5:3 (20mm graded aggregate) for foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc complete all as specified and directed.

6

-

-

... More
M&L for cement concrete nominal mix 1:1.5:3 (20MM graded aggregate ) for column etc complete all as specified and directed.

1.5

-

-

... More
M&L for soft/loose soil Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. complete all as specified and directed.

26

-

-

... More
M&L 100 mm thick PCC 1:4:8 type D-2(using 20 mm graded agg.) as in sub base unde floors complete all as specified and directed.

210

-

-

... More
S&F Plates (plain or chequered ) channels,square cut or notched (ordinary and counter sunk ) and forming holes with riveted, bolted or welded attachment complete all as specified and directed.

80

-

-

... More
M&L Steel work in tubular trusses, post, purlins & rafters including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 GRADE ST -240 complete all as specified and directed.

1015

-

-

... More
M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed.

1512

-

-

... More
M&L Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.

28

-

-

... More
S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 22.5 and not exceed 30 cm and dia 16 to 20mm complete all as specified and directed.

68

-

-

... More
M&L for 75mm thick PCC (1:3:6) type C-2 using 40mm graded mechanically crushed stone agg as in plinth protection, flooring finished even & smooth without using extra cement including forming and filing of construction joints complete all as specified and directed.

28.5

-

-

... More
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and complete all as specified and directed.

68

-

-

... More
M&L for point wiring with 1.50 sqmm in copper conductor cable ( multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit ( ISI Marked) of heavy duly with all accessories ie PVC gutties including sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ complete all as specified and directed. in ceiling Portion surface conduit wiring to be done. . Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.iii) Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost.

40

-

-

... More
All as per item No 54 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and complete all as specified and directed.

10

-

-

... More
All as per item No 54 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and directed.

12

-

-

... More
All as per serial item No 54 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 1.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and directed.

6

-

-

... More
M&L for Modular Socket 6A/16A - 2/3 pin 2 module type all as specified and directed.

6

-

-

... More
M&L for Modular Socket, 6A - 5 pin 2 module type all as specified and directed.

22

-

-

... More
M&L for Modular switch 1 way 6A, 1module all as specified and directed.

62

-

-

... More
M&L for Modular switch 1 way 16A, 1module type all as specified and directed.

6

-

-

... More
M&L for fan step regulator 120 W - 2 module complete all as specified and directed.

8

-

-

... More
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all as specified and directed.

30

-

-

... More
Supply and fixing for sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC concealed conduit with 4 Sqmm PVC copper conductor cable as in earth wire system including taking out old wiring complete all as specified and directed. Note: Neccessary cutting chasing wherever required and making good the disturbed surface shall be part of job at no extra cost.

30

-

-

... More
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 8 way double door type with 200 amp rated bus bar with degree of protection IP-54. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.

2

-

-

... More
Supply and fix in replacement of MCB SP up to 6-20 Amp all as specified and directed. Make: Havells Cat part No : DHMGBSPF006-032 or equivalent MAKE mentioned hereinafter.

12

-

-

... More
Supply and fix in replacement of MCB SPN 20-40 Amp complete all as specified and directed. Make: Havells Cat part No DHMGCSNF006-032 or equivalent MAKE mentioned hereinafter.

2

-

-

... More
Supply & fix in replacement of existing unserviceable batten fitting with LED batten fitting of 20W, 4 feet long of extruded thermoplastic body with PC diffuser, isolated body environmental friendly energy efficient including neccesary fitting on wall and making electric connection from ceiling rose to connector with suitable size of electric cable and making good the disturbed surface.

20

-

-

... More
Material and labour for angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 7 to 18 watts for batten fitting, complete all as specified and directed.

8

-

-

... More
Supply and fix LED Lamp 9W B22 inverter type all as per Havells or equivalent in complete all as specified and directed.

8

-

-

... More
M&L for Supply and fixing ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.

8

-

-

... More
Supply & lay in replacement of existing unserviceable XLPE insulated, armoured heavy dutyelectric cable with aluminium conductor, 1100 volt grade of crosssectional area 25 Sqmm 3 & 1/2 Core complete all as specified and directed.

50

-

-

... More
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed.

9

-

-

... More
M&L for Sand cushioning for cables 8 cm below the cable and 15 cm above the cable complete all as specified and directed.

3

-

-

... More
Material and labour for old size brick well burnt, laid flat, for cable protection complete all as specified and directed.

250

-

-

... More
Material and labour for replacement of GI tubing light grade 40 mm bore for passing through cables under the floor ,along the wall or along the pole complete all as specified and directed.

6

-

-

... More
M&L for earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I

1

-

-

... More
Supply and fixing LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, all as specified and directed.

4

-

-



Evaluation Notes How It Works ?

Potential Partner

Select Your Requirements

Past Bidders
This list is curated from the bidders of the similar tenders in the past

Unlock the Tender details for free
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
  • Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
  • Awarded Ratexx%
Disclaimer: BidAssist has made every reasonable effort to ensure that the information is accurate and authentic however it cannot be held liable for any third-party claims or losses of any damages. BidAssist makes no warranty, expressed or implied, as to the results obtained from the use of the information. If you think you may have noticed any error or omission, please let us know by contacting contact@bidassist.com.