Military Engineer Services Tender
If you want to inquire about any e-tender the Punjab government has posted, Bidassist gives a one-stop solution i.e. being a registered bidder you will find every eprocurement Punjab tender on BidAssist.There is no need to enter all the details on the website of etender.up.nic.in as BidAssist helps you find the specific Punjab etender you're looking for. Read further to learn how to search and bid for etender Punjab.
Costs
EMD
₹ 6,91,500Document Cost
₹ 3,000Tender Fee
Refer Documents
Description
Scription for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user this is tender description for unregistered user
Contact
Tender Id
2024_MES_677962_1Tender No
CEAFU-11/2024-25Tender Authority
Military Engineer Services ViewPurchaser Address
-Website
http://http://mes.gov.in/
GEM & Bid Advisory Services
Get portal registration, tender bidding, product/service listing or vendor/MSME certification services at a nominal cost
Documents
BOQ Items
Taking out Distribution boards, bus bar chambers including bus bar, MCB's of any type and size and connected accessories of any type and size complete all as specifed and directed.
22
-
-
Taking out underground LT cable of any type and size complete all as specified and directed.
600
-
-
Dismantling of gate/globe valve of any type and size complete all as specified and directed
6
-
-
Taking down old unsv solar water heating systed from Bldg and depositing in MES Storeyard complete all as specifed and directed.
2
-
-
Total amount of Schedule 'A' PART-II (Section-II) (Demoliation of buildings)
-
-
-
Total amount of Sch 'A' PART-III (SECTION-I) ( INTERNAL ELECTRIC SUPPLY WORKS)
1
-
3456948.68
Sch 'A' PART-III ( Section-II) ( INTERNAL ELECTRIC SUPPLY WORKS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
Supply and fixing Modular metal Flush box as per site requirement for 8 module complete all as specifed and directed.
40
-
-
Suply & Fixing LED Building security Light fitting 25 watt, for opearting voltage between 110V to 320V system efficiency not less than 120 lumen / watt, PF-0.95 minimum, IP66 protection, 5700CCT(K), CRI between 80-85, confirming to LM79 and LM 80 standards or as per IS-16104:2012 and IS-16106:2012, for estimated life span of minimum 50,000 hrs consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with LED street optics LENS for uniform light distribution, weather proof gasket for lamp & driver compartment, Heat resistance toughened UV stabilized glass fitted in cast aluminium housing with SS screws, complete all as specified and as directed by Engr-in-charge.
32
-
-
Supply & Fixing 12 watt Dexter rotatable reading bedside LED enegy efficient wall light having comfortable color temperature, made of brushed Gold,brushed black,electroplating or powder coating. fitting has light colour of 3 type i.e Warm White,Natural White and Cold White it has push button switch for on/off and diemsionof fitting is 16Lx18Wx9.5H cm, complete all as specified and directed.
60
-
-
Supply & Fixing Vertical triple phase & neutral Distribution box double door type ,as per IEC 61439-3 made of sheet metal enclosure dust proof vermin proof suitable for flush mounting and surface mounting with 250A Copper Busbar for each phase,415 volts with in built MCCB 63 Amps, 25KA, 2 Neutral bar,2 Earthbar IP 54 Protection and cable ties for cable management,fully insulated busbar & shrouded Neutral bars, reversible door for IP 43 & IP54 DB's, flush mounted to wall complete all as specified and directed. Note:- Rate are inclusive of Flush(concealed) Mounting of DB and MCCB 63Amps
4
-
-
Supply and fixing MCB Single Pole 2 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified.
112
-
-
Supply and fixing MCB Single Pole 6 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified.
192
-
-
Supply and fixing MCB Single Pole 16 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified.
40
-
-
Supply and fixing MCB Single Pole 40-63 Amps rating 240V, 10KA 'C' curve miniature circuit breaker complete with connection testing and commissioning complete all as specified.
16
-
-
Total amount of Sch 'A' PART-III (Section-II) (INTERNAL ELECTRIC SUPPLY WORK)
-
-
-
Total amount of Sch 'A' PART-IV (INTERNAL WATER SUPPLY WORKS)
1
-
373773.72
Total amount of Sch 'A' PART-V Sanitary Plumbing/Fittings
1
-
586380.12
Total amount of Sch 'A' PART-VI (SECTION-I) (Summer appliances)
1
-
554123.12
SCHEDULE `A' PART-VI(SECTION-II) (Summer appliances) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
Supply and fixing voltage stabilizer capacity 2 KVA with digital IC controlled circuit for automatic operation time delay relay modes to ensure the equipment safety, single phase naturally air cooled designed for input variation between 150V to 280 V and output voltage stabilized at 230V with accuracy of + 2.5% complete all as specified and as directed
8
-
-
Supply , installation and commissioning of evaporative air cooler (desert cooler) steel body electric driven operation on 230 volts + 10%, single phase AC supply, 50 Hz, 450mm sweep fan blades (Aluminium blades) with suitable capacity of motor, fitted with reputed brand ISI marked conforming to IS 11951: 1987 submersible pump set, paino type ON OFF switch and speed selection switch for three speed cooler fan motor, minimum air capacity of the evaporative air cooler based on the delivery of air at 'zero' static pressure shall be 4000 m3/hr (or nearest size)) complete with PVC pipe of suitable legnght and float vlave, provided three-core-cable conforming to IS 694 : 1990 or IS 9968 (Part-1) :1988 of 2.5 mtr length fitted with 3 pin moulded plg top of 5/6 amp rating. The desert cooler body shall be made of galvanised sheet steel 20 gauge (0.9mm) superior quality with following arrangements as under :-
88
-
-
(a) Grill -The front grill shall be made of non-corrosive material with an arrangement for adjusting horizontal and vertical directional flow of air.
(b) Water feeding arrangement : Suitable water feeding arrangement shall be provided from the back side as well as front side.
(c) Size of fan opening (Not Grill Opening) : This circular opening shall be more than fan sweep but shall be not exceeding more than 25mm.
(d) Filter Pads- Filter pads shall be made of wood wool or any other substitute placed in non-corrosive wire mesh and tightened at places with side panels to avoid sagging.
(e) Minimum sump tank capacity shall be 80 Ltrs cooler shall be provided with an accessible drain on left or right side. The drain cock and drain cook cap shall be or brass material.
(f) The noise level should not be more than 65 dBA at 1m distance from the desert cooler.
-
-
-
Total amount of Sch 'A' PART-VI (SECTION-II) (Summer appliances)
-
-
-
Total amount of Sch 'A' PART-VII (Section-I) (Hot water supply)
1
-
1640607.28
SCHEDULE `A' PART-VII (SECTION-II) (Hot water supply) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
Cutting existing GI pipe of any size for taking new connection incl all fittings, joints etc.complete all as specified and as directed.
8
-
-
Total amount of SCHEDULE `A' PART-VII (SECTION-II) (Hot water supply)
-
-
-
Total amount of Sch 'A' PART-VIII (Road/ path/ culvert)
1
-
3275966.11
Total amount of Sch 'A' PART-IX (Section-I) (External Electric supply)
1
-
463148.8
SCHEDULE `A' PART-IX(SECTION-II) (External Electric supply) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
supply and fixing LT Cable junction box outdoor shall be made out of Polycarbonate with glass fiber reinforced than 205mm x 255mm x 112 mm(the cable size upto 25 sqmm). The polycarbonate junction box shall be environmental friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66 in accordance with IEC 60529.Weatherproof, UV resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998. The Junction Box with 25Amp Connectors or Terminal Trip or Bus Bar. The Junction Box / Enclosure shall be tested as per IEC including one No. 4 pole connector and chromium plated clamps and nut bolts, cable glands with lock nuts of 2 Nos for each box complete all as per manufacturer’s Make:- Cat Part : KF2525 B of Hensel / Seimens / GE P{ower / Rittal/ Legrand
20
-
-
Supply, testing and commissioning of outdoor weather & dust vermin proof L.T. Panel board factory fabricated indoor cubicle type totally enclosed with outer sheel shall be made out of 3.15 mm thick sheet & MS angle section of suitable size for frame, factory fabricated, compartmentalized inner shell shall be made of out of 2.0 mm thick sheet .The Panels must be design and verified as per the IS/IEC 61439-01 & 2 with complete type test certificates for conformance to IS / IEC 61439 -1 and 2, with 65 KA 1 sec along with MCCB mounted in switch boards with aluminium bus bars as mandatory as conformed to IEC 61641 with internal arc containment fault level of 65 KA/03 Sec and shall be suiatbale for Seismeic Zone III/IV Zone including the type test conducted at ERDA/CPRI for seismic test.All MCCB/ ACB panel should be single Tier for easy cable termination.Cable termination space should be adequate to safely gland and terminate al/cu cables for the given current ratings with Form B seperation for Incoming MCCB / ACB feeders and For Outgoing MCCB feeders. The Switch board cubicles shall have steel frame work enclosed on all sides and top by CRCA sheet steel of Minimum 2.00 mm thickness.The panel shall have integral base frame of 100 MM ISMC base channel.removeable undrilled gland plates shall be fitted for bottom cable entry and making connections, earth work and PCC foundation complete comprising of the followings and specified herewith:-
1
-
-
(i) Rectangular alumimium bus bar fixed on insulated mounting arrangement 300 Amps current rating -04 Nos provided with heat shrinkable sleeve not less than one mm thick.
(ii) Cable alley for 01 I/C and 03 outging feeders.
(a) INCOMING
(i) MCCB 4P 160 Amps,4 Pole,415V,50 c/s 25KA Icu =50 KA with microprocessor release type - 01 No (I/C) . Ics = 100 % Icu and class II front face, Isolation with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc . (ii) Ammeter digital type 0 to 500 A - 1 Nos
(iii) Voltmeter digital type 0-500 V - 1 Nos
(iv) Three way selector switch for current - 1 Nos
(v) Three way selector switch for voltage - 1 Nos
(vi) Phase indicating RYB light LED type - 1 set.
(vii) Suitable CTs of cast resin type with necesaary CT shortlinking should be provieded . - 1 set.
OUTGOING: (a) MCCB Four pole 63 Amps Icu =16 KA at 415 volts, adjustable type with thermal magnetic release -04 No (O/G) ( 3 W + 1S) . They should be with adjustable over load setting Ir = (0.8 to 1.0) x In,Ics = 100 % Icu and with adjustable thermal setting. Class II front face with positive break indication with double break contacts, Standard extended rotary handle,Spreaders, Phase barrier etc (b) MCB DP capacity 16 amp, 'C' series-03 Nos (e) Timer switch along with 415 V three Phase contactors 25 Amp rating and MCB 4 Pole 415 V, 25 Amps as incoming and one MCB 4 Pole 415 V, 20 Amps as outgoing incl copper cable for connection and fixing complete all as specified and directed (f) All accessories prewired with suitable size copper wire with stand high temperature, housed in cubical panel made out of standard MS sheet factory made duly powder coated front and rear door open able with locking arrangement complete with foundation as required or recommended by manufacturer.
-
-
-
Note
(i) Main Aluminum busbars with 0.8Amps/sqmm current density & all internal wiring with copper FRLS wires and connections. All MCCB's are Microprocessor/Thermal Magnetic based (Icu = Ics = 100%) as given in sld, housed in separate compartments, enclosed on sides, with rotating handle. All MCB Icu=10kA where not given/mentioned.
(ii) Earthing all components, frame etc. to a common internal earth bar.
(iii) Painting all sheet metal works support structure etc.
(iv) All accessories & supporting structure (Hot Dip Galvanised).
(v) The panel shall be with Galvanized MS mounting base frame & the height shall not exceed more than 2100mm.
(vi) The panel shall be prewired, ready for External Cable termination.
(vii) All Gland Plate's shall be 3 mm thick removable type. (viii) All the CT's shall be cast resin type, with necessary CT shorting link.
(ix) The panel shall be in convenient sections suitable for transportation, erection & have sufficient space for Incoming & Outgoing cable terminations.
(x) The panel Incomers/Outgoings shall have Potential free Contact.
(xi) 3 mm thick acrylic sheet shall be provided on the top of all outgoing termination sections, for protection against live terminals. (xii) All the panel Incomers & Outgoings shall be tagged with aluminum anodized engraved name plates (Detailed tag of the feeders will be given during the final approval of panel drawings)
(xiii) Vendor shall arrange to configure / check / set all the meters once the panel is completely installed & in operation at site.
-
-
-
Supply and fix PVC insulated multistrand FRLS copper cable of size 1.5 Sqmm in and including PVC non metalic rigid conduit 15mm dia with necessary fittings such as elbows sockets Tee, bends etc for connection to light fittinmgs from junction box complete all as specified
200
-
-
Supply, installation, connecting electrically & commissioning LT feeder box , outdoor type of size 0.90x0.60x0.40 Mtr size factory fabricated made out of MS sheet of thickness 3.15 mm front and back door openable with locking arrangement mounted on angle iron legs made out of angle iron of size 40x40x6 mm , 1.0 mtr long , 0.7 mtr above ground level and 0.30 mtr embedded in PCC blocks of size 0.30x0.30x0.30 mtr -04 Nos duly painted with two coats of synthetic enamel paint over a coat of red oxide complete with 150 Amps rated aluminium bus bar suitable for 3 phase 4 wire supply dully drilled holes for cable connection mounted on epoxy based post insulators and MCCB 63 AMP,16 KA, 4 Pole 415 V make Legrand, all as specified and direc ted by Engr-in-Charge.
1
-
-
S & F cable route indicator at the distance of 50 mtrs each made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLE suitably incribed on CI circular plate 8 mm thick 100 dia including painting with two coats of synthetic enammel p[aint overa coat of red oxide primer including necessary PCC 1:3:6, type C2 ( using 40 mm graded aggregate ) block of suitable size and neccessary earth work and excavation all as specified and directed.
50
-
-
Total amount of Sch 'A' PART-IX(SECTION-II) (External Electric supply)
-
-
-
Total amount of Sch 'A' PART-X ( Section I) (External water supply)
1
-
201693.04
Sch 'A' PART-X ( (Section-II) (External water supply) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
Material and labour for construction of valve chamber of size 900x900x900mm deep dimesions (Over all internal dimension) for control valve etc with PCC foundation, PCC block masonry walls, plastering, PCC coping white washing, mild steel chamber cover, painting to chamber cover including excavation and earth work in any type of soil complete all as specified below:-
Valve chamber shall be provided with the following specifications :-
(i) Cement concrete for foundation (1:4:8) type D2 using 40mm graded stone aggregate 150mm thick extended upto 150mm beyond the outer face of block masonry.
(ii) Walls of vlaver chamber 200mm thick with precast cement concrete (1:5:8) (using 20mm graded stone aggregate) solid building block settingin CM 1:6 complete
(iii) Internal and exposed surfaces of valve chamberboth concrete and block masonry surface shall be plastered with CM (1:4), 15mm thick finished even and smooth.
(iv) 50mm thick coping in PCC 1:3:6 type C1 over block masonry wall .
(v) Entire plastered surfaces shall be treated with 3 coat of white wash.
(vi) Chamber cover shall be of 3mm thick MS sheet with 40x40x6 mm size angle iron frame with hold fast and locking arrangement including handle. Steel surface shall be painted with two coats of synthetic paint of first quality over one coat of red oxide primer
3
-
-
Total amount of Sch 'A' PART-X(SECTION-II) (External water supply)
-
-
-
Total amount of Sch 'A' PART-XI (Area Drainage)
1
-
775513.45
Total amount of Sch 'A' PART-XII (Section- I) (Sewage disposal works)
1
-
269590.14
Sch 'A' PART-XII (SECTION-II) (Sewage disposal works) Note: This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
-
-
-
Supply & Fixing HDPE DWC (Double wall corrugated) pipes confirming to IS-16098 of 152mm & 180mm internal & external dia respectively. Pressure rating SN-8 fixed with rubber seal and copler required with and incl. suitable bends 90/60/45 degree etc single Y junction complete as required fixed as per manufacture instruction laid in trenches for sewage line all as specified and directed . Note- rates included for pipes , bends any size, types Y junction copler/adopter etc required and net total length of pipe with fittings shall be measured for payment purpose.
250
-
-
Total amount of Sch 'A' PART-XII (SECTION-II) (SEWAGE DISPOSAL WORK)
-
-
-
Total amount of Sch 'A' PART-XIII (Site clearance, excavation & earth works)
1
-
640404.95
NOTE: Amount against schedule of credit of Rs. 5,55,457.50 for retrieved materials mentioned under relevant part XIV of Sch of Credit of tender document in PDF form will be deducted offline/manually from overall amount quoted by the lowest bonafide bidder during acceptance of tender.
-
-
-
Evaluation Notes How It Works ?
Potential Partner
Select Your Requirements
Past BiddersThis list is curated from the bidders of the similar tenders in the past
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%
- Bidder NameThis Information is for unsubscribed user This Information is for unsubscribed user
- Awarded Ratexx%